Victaulic Company

AGS - Style W741 - Vic-Flange Adapte Brochure

Style 741Style 741 Vic-Flange® adapter is designed for directly incorporating flanged components with ANSI CL. 125 or CL. 150/PN10 and PN16 or Australian Standard Table “E” bolt hole patterns into a grooved pipe system. Sizes 2 – 12"/50 – 300 mm are hinged for easy handling with integral end tabs which facilitate assembly. Sizes 14 – 24"/350 – 600 mm are cast in four (4) identical segments which are interconnected as assembly is completed.The design incorporates small teeth inside the key shoulder I.D. to prevent rotation (excluding 159 mm size). These teeth should be removed when Vic-Flange adapter is utilized with a Victaulic Series 700 grooved end butterfly valve, Schedule 5 pipe or plastic pipe.Vic-Flange adapter Style 741 is not recommended for use with Victaulic Series 709 butterfly valves (contact Victaulic for recommendations). They may only be used on one side of Victaulic Series 700 butterfly valve, sizes 2 – 4"/50 – 100 mm fitted with standard or lever-lock handles. Vic-Flange adapter must be assembled so it does not interfere with handle operation.Style 743Vic-Flange Style 743 flange-to-groove adapter permits direct connection of ANSI Class 300 flanged components into a grooved system. The two-piece, hinged housing engages into the pipe groove and bolts directly to any standard flanged component. The conventional bolt hole pattern allows for easy, fast assembly. Style 743 rotates 360° for proper alignment of bolt holes before tightening. Vic-Flange gaskets utilize the Victaulic pressure-responsive design, sealing on the pipe end and directly to the opposing flange face. No standard flange gasket is required.Style 743 is designed to mate with raised-face flanges, but can be used with flat-face flanges by removing the raised projections on the outside face of the flange.Note: Performance data presented in this document is based on use with standard wall, carbon steel pipe. For use with stainless steel pipe, please reference document 17.09 for pressure ratings and end loads. When used on light wall stainless steel pipe, the Victaulic RX roll set must be used to roll groove the pipe. For further information regarding roll grooving stainless steel, refer to document 17.01.Vic-Flange noteS Because of the outside flange dimension, Vic-Flange should not be used within 90° of one another on a standard fitting. When wafer or lug-type valves are used adjoining a Victaulic fitting, check disc dimensions to assure proper clearance.Vic-Flange adapters should not be used as anchor points for tie-rods across non-restrained joints. Mating rubber faced flanges, valves, etc., requires the use of a Vic-Flange washer.Vic-Flange gaskets must always be assembled with the color coded lip on the pipe and the other lip facing the mating flange.06.06_1Vic-Flange® adaptersStyleS 741 and 74306.06carbon Steel pipe – grooVed couplingSjob/owner contractor engineerSystem No. __________________________ Submitted By ________________________ Spec Sect ____________ Para __________Location ____________________________ Date ________________________________ Approved ___________________________Date ________________________________www.victaulic.comVICTAuLIC IS A REgISTERED TRADEMARk oF VICTAuLIC CoMPANy. © 2013 VICTAuLIC CoMPANy. ALL RIghTS RESERVED.reV_oSEE VICTAULIC PUBLICATION 10.01 FOR DETAILSStyle 7412 – 12" SizeS/50-300 MMStyle 74114 – 24" SizeS/350-600 MMStyle 743Exaggerated for clarityVic-FlangeProper Gasket PositioningMatingFlangeAMax.BMin.Exaggerated for ClarityExaggerated for ClarityExaggerated for clarityHousing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request.Housing coating: Black enamel. • Optional: hot dipped galvanized and others.coupling gasket: (specify choice‡) • Grade “E” EPDMEPDM (green color code). Temperature range –30°F to +230°F/–34°C to +110°C. Recommended for hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. uL classified in accordance with ANSI/NSF 61 for cold +86°F/+30°C and hot +180°F/+82°C potable water service. NoT RECoMMENDED FoR PETRoLEuM SERVICES. • Grade “T” nitrileNitrile (orange color code). Temperature range –20°F to +180°F/–29°C to +82°C. Recommended for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range; except hot, dry air over +140°F/+60°C and water over +150°F +66°C. NoT RECoMMENDED FoR hoT WATER SERVICES.‡ Services listed are general Service Recommendations only. It should be noted that there are services for which these gaskets are not recommended. Reference should always be made to the latest Victaulic gasket Selection guide for specific gasket service recommendations and for a listing of services which are not recommended.NoTE: Additional gasket styles are available. Contact Victaulic for details.draw bolts: 14 – 24"/350 – 600 mm only: heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183.Material SpeciFicationS06.06_2Vic-Flange® adaptersStyleS 741 and 74306.06carbon Steel pipe – grooVed couplingSwww.victaulic.comVICTAuLIC IS A REgISTERED TRADEMARk oF VICTAuLIC CoMPANy. © 2013 VICTAuLIC CoMPANy. ALL RIghTS RESERVED. reV_odiMenSionSWYZXStyle 741Sizes 2 – 12"/50 – 300 mm ANSI Class 125 and 150 FlangesSizeMax. work pressure *Max. end load * no. bolts † bolt Size †Sealing Surfaceinches/mm dimensions – inches/mmapprox. wgt. eachnominal Size inchesmmactual outside diameter inchesmmpsi kpalbs.n required inches“A”Maximum“B”Minimum w X y zlbs. kg2 2.375 300 1,330 4 5/8 x 2 3/4 2.38 3.41 6.75 6.00 4.75 0.75 3.150 60.3 2065 5920 60 87 172 152 121 19 1.42 1/2 2.875 300 1,950 4 5/8 x 3 2.88 3.91 7.87 7.00 5.50 0.88 4.865 73.0 2065 8680 73 99 200 178 140 22 2.13 3.500 300 2,885 4 5/8 x 3 3.50 4.53 8.29 7.50 6.00 0.94 5.380 88.9 2065 12840 89 115 211 191 152 24 2.44 4.500 300 4,770 8 5/8 x 3 4.50 5.53 9.87 9.00 7.50 0.94 7.4100 114.3 2065 21225 114 141 251 229 191 24 3.45 5.563 300 7,290 8 3/4 x 3 1/2 5.56 6.71 10.90 10.00 8.50 1.00 8.6125 141.3 2065 32440 141 171 277 254 216 25 3.96 6.625 300 10,350 8 3/4 x 3 1/2 6.63 7.78 11.90 11.00 9.50 1.00 9.9150 168.3 2065 46060 168 198 302 279 241 25 4.5165.1 mm 6.500 300 9,960 8 3/4 x 3 1/2 6.50 7.66 11.92 11.00 9.45 1.00 10.0165.1 2065 44320 165 195 303 279 240 25 4.58 8.625 300 17,500 8 3/4 x 3 1/2 8.63 9.94 14.50 13.50 11.75 1.13 16.6200 219.1 2065 77875 219 252 368 343 298 29 7.510 10.750 300 27,215 12 7/8 x 4 10.75 12.31 17.24 16.00 14.25 1.19 24.2250 273.0 2065 121110 273 313 438 406 362 30 11.012 12.750 300 38,285 12 7/8 x 4 12.75 14.31 20.25 19.00 17.00 1.25 46.8300 323.9 2065 170270 324 364 514 483 432 32 21.2* Working Pressure and End Load are total, from all internal and external loads, based on standard weight steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe.WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown.† Total bolts required to be supplied by installer, may be ordered from Victaulic.IMPORTANT NOTES: Style 741 Vic-Flange adapters provide rigid joints when used on pipe with standard cut or roll groove dimensions and consequently allow no linear or angular movement at the joint. When used with Victaulic Series 700 butterfly valves, plastic pipe or light wall metallic pipe, small teeth in I.D. of key section should be removed and may be used on one side of the valve. Contact Victaulic for information on ISO 2084 (PN10); DIN 2532 (PN10) and JIS B-2210 (10K) flanges.Vic-FlangeProper Gasket PositioningMatingFlangeAMax.BMin.Exaggerated for ClarityExaggerated for ClarityShaded area of mating face must be free from gouges, undulations or deformities of any type for effective sealing.06.06_3Vic-Flange® adaptersStyleS 741 and 74306.06carbon Steel pipe – grooVed couplingSwww.victaulic.comVICTAuLIC IS A REgISTERED TRADEMARk oF VICTAuLIC CoMPANy. © 2013 VICTAuLIC CoMPANy. ALL RIghTS RESERVED. reV_odiMenSionSStyle 741Sizes 50 – 300 mm/ 2 – 12"PN10 and PN16 FlangesSize pn10 Flanges pn16 FlangesSealing Surfaceinches/mm dimensions – mm/inchesapprox. wgt. eachnominal Size mminchesactual outside diameter mminchesMax. work pressure *Max. end load * bolts †Max. work pressure *Max. end load * bolts †“A”Maximum“B”Minimum w X y zkg lbs.bars *p`sinlbs.no.req’d.Sizemmbars *psinlbs.no.req’d.Sizemm50 60.3 10 2850 4 16 16 4561 4 16 60 87 177 165 125 20 1.42 2.375 145 640 230 1025 2.38 3.41 6.97 6.50 4.92 0.79 3.176.1 mm 76.1 10 4540 4 16 16 7275 4 16 76 103 208 185 145 20 2.13.000 145 1020 230 1635 3.00 4.05 8.19 7.28 5.71 0.79 4.780 88.9 10 6210 8 16 16 9925 8 16 89 115 218 200 160 22 2.43 3.500 145 1395 230 2230 3.50 4.53 8.58 7.87 6.30 0.87 5.4100 114.3 10 10260 8 16 16 16420 8 16 114 141 251 229 180 24 3.54 4.500 145 2305 230 3690 4.50 5.55 9.88 9.00 7.09 0.94 7.7139.7 mm 139.7 10 15330 8 16 16 24520 8 16 141 171 274 250 210 24 4.25.500 145 3446 230 5512 5.55 6.73 10.79 9.84 8.27 0.94 9.3159.0 mm 159.0 10 19800 8 20 16 31400 8 20 159 187 307 285 240 26 4.56.250 145 4450 230 7056 6.25 7.36 12.09 11.0 9.45 1.02 10.0165.1 mm 165.1 10 21400 8 20 16 34236 8 20 165 195 303 280 240 25 4.56.500 145 4811 230 7632 6.50 7.68 11.93 11.00 9.45 1.00 10.0150 168.3 10 222508 2016 356008 20168 198 302 279 240 25 4.56 6.625 145 5000 230 8000 6.63 7.78 11.89 10.98 9.45 1.00 10.0200 219.1 10 37690 8 20 16 60320 12 20 219 252 368 # 342 # 295 # 29 # 7.58 8.625 145 8470 230 13555 8.63 9.94 14.49 13.46 11.65 1.14 16.6250 273.0 10 58560 12 20 16 93695 12 24 273 313 437 § 395 § 350 § 27 § 11.010 10.750 145 13160 230 21055 10.75 12.31 17.20 15.55 13.78 1.06 24.2300 323.9 10 82370 12 20 16 131810 12 24 324 365 478 ‡ 460 ‡ 400 ‡ 32 ‡ 17.412 12.750 145 18510 230 29620 12.75 14.31 18.82 18.11 15.75 1.26 38.4* Working Pressure and End Load are total, from all internal and external loads, based on standard weight steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe.WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown.# PN16 dimensions (mm/inches): W = 360/14.17; X = 340/13.39; Y = 295/11.61; Z = 30/1.18.§ PN16 dimensions (mm/inches): W = 438/17.24; X = 406/15.98; Y = 355/14.00; Z = 30/1.18.‡ PN 16 dimensions (mm/inches): W = 478/18.82; X = 444/18.11; Y = 410/16.14; Z = 32/1.26.† Total bolts required, to be supplied by installer. Bolt sizes for conventional flange-to-flange connection.Longer bolts required when flange utilized with wafer-type valves.IMPORTANT NOTES: Style 741 Vic-Flange adapters provide rigid joints when used on pipe with standard cut or roll groove dimensions and consequently allow no linear or angular movement at the joint. When used with Victaulic Series 700 butterfly valves, plastic pipe or light wall metallic pipe, small teeth in I.D. of key section should be removed and may only be used on one side of the valve. Contact Victaulic for information on AS2129 - Table E; ISO 2084 (PN10); DIN 2532 (PN10) and JIS B-2210 (10k) flanges.Vic-FlangeProper Gasket PositioningMatingFlangeAMax.BMin.Exaggerated for ClarityExaggerated for ClarityWYZXShaded area of mating face must be free from gouges, undulations or deformities of any type for effective sealing.06.06_4Vic-Flange® adaptersStyleS 741 and 74306.06carbon Steel pipe – grooVed couplingSwww.victaulic.comVICTAuLIC IS A REgISTERED TRADEMARk oF VICTAuLIC CoMPANy. © 2013 VICTAuLIC CoMPANy. ALL RIghTS RESERVED. reV_odiMenSionSWYZXStyle 741Sizes 2 – 8"/50 – 200 mm Australian Standard Table “E” FlangesSizeMax. work pressure *Max. end load * no. bolts † bolt Size †Sealing Surfacemm/inches dimensions – mm/inchesapprox. wgt. eachnominal Size mminchesactual outside diameter mm incheskpa psin lbs. required inches“A”Maximum“B”Minimum w X y zkg lbs.50 60.3 1400 4005 4 5/8 x 2 3/4 60 84 165 152 114 19 1.92 2.375 203 900 2.38 3.31 6.50 6.00 4.50 0.75 4.180 88.9 1400 8700 4 5/8 x 3 89 113 200 191 146 24 2.43 3.500 203 1955 3.50 4.44 7.87 7.50 5.75 0.94 5.4100 114.3 1400 14374 8 5/8 x 3 114 131 251 229 178 24 3.34 4.500 203 3230 4.50 5.16 9.87 9.00 7.00 0.94 7.2165.1mm 165.1 1400 14374 8 3/4 x 3 1/2 165 192 303 279 235 25 5.06.500 203 6735 6.50 7.56 11.92 11.00 9.25 1.00 11.0150 168.3 1400 31150 8 3/4 x 3 1/2 168 192 286 279 235 25 4.56 6.625 203 7000 6.63 7.56 11.25 11.00 9.25 1.00 9.9200 219.1 1400 52777 8 3/4 x 3 1/2 219 247 368 343 292 29 5.78 8.625 203 11860 8.63 9.72 14.50 13.50 11.50 1.12 12.5* Working Pressure and End Load are total, from all internal and external loads, based on standard weight steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe.WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown.† Total bolts required to be supplied by installer, may be ordered from Victaulic.IMPORTANT NOTES: Style 741 Vic-Flange adapters provide rigid joints when used on pipe with standard cut or roll groove dimensions and consequently allow no linear or angular movement at the joint. When used with Victaulic Series 700 butterfly valves, plastic pipe or light wall metallic pipe, small teeth in I.D. of key section should be removed and may be used on one side of the valve. Contact Victaulic for information on ISO 2084 (PN10); DIN 2532 (PN10) and JIS B-2210 (10K) flanges.Vic-FlangeProper Gasket PositioningMatingFlangeAMax.BMin.Exaggerated for ClarityExaggerated for ClarityShaded area of mating face must be free from gouges, undulations or deformities of any type for effective sealing.06.06_5Vic-Flange® adaptersStyleS 741 and 74306.06carbon Steel pipe – grooVed couplingSwww.victaulic.comVICTAuLIC IS A REgISTERED TRADEMARk oF VICTAuLIC CoMPANy. © 2013 VICTAuLIC CoMPANy. ALL RIghTS RESERVED. reV_odiMenSionSTZVYBAXWVic-FlangeProper Gasket PositioningMatingFlangeAMax.BMin.Exaggerated for ClarityExaggerated for ClarityStyle 741Sizes 14 – 24"/350 – 600 mm#ANSI Class 125 and 150 FlangesSizeMax. work pressure *Max. end load * assembly bolts †draw bolts §Sealing Surfaceinches/mm dimensions – inches/mmapprox. wgt. eachnominal Size inchesmmactual outside diameter inchesmmpsi kpalbs.nno. req. †Size inchesno. req.Size inches“A”Max.“B”Min. t V w X y zlbs. kg14 14.000 300 46,180 12 1 x 4 1/2 4 5/8 x 3 1/2 14.00 16.39 19.38 0.94 24.50 21.00 18.75 2.50 62.0350 355.6 2065 205500 356 416 492 24 622 533 476 64 28.116 16.000 300 60,300 16 1 x 4 1/2 4 5/8 x 3 1/2 16.00 18.39 21.50 0.94 27.12 23.50 21.25 2.50 79.0400 406.4 2065 268335 406 467 546 24 689 597 540 64 35.818 18.000 300 76,340 16 1 1/8 x 4 3/4 4 3/4 x 4 1/4 18.00 20.00 22.25 1.00 29.00 25.00 22.75 2.75 82.3450 457.0 2065 339700 457 508 565 25 737 637 578 70 37.320 20.000 300 94,250 20 1 1/8 x 5 1/4 4 3/4 x 4 1/4 20.00 22.50 25.00 1.00 31.50 27.50 25.00 2.75 103.3500 508.0 2065 419400 508 572 635 25 800 699 635 70 46.924 24.000 300 135,700 20 1 1/4 x 5 3/4 4 3/4 x 4 1/4 24.00 27.75 29.00 1.00 36.00 32.00 29.50 3.00 142.0600 610.0 2065 603865 610 705 737 25 914 813 749 76 64.4* Working Pressure and End Load are total, from all internal and external loads, based on standard weight steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe.WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown.† Total bolts required to be supplied by installer, may be ordered from Victaulic. Bolt sizes for conventional flange-to-flange connection. Longer bolts required when Vic-Flange utilized with wafer-type valves.§ Draw bolts supplied with 14 – 24”/350 – 600 mm Vic-Flange adapters.# For cut groove systems only. For 14 – 24”/350 – 600 mm roll groove systems, AGS (Advanced Groove System) products are used. Style 741 is not compatible with the AGS system.Shaded area of mating face must be free from gouges, undulations or deformities of any type for effective sealing.06.06_6Vic-Flange® adaptersStyleS 741 and 74306.06carbon Steel pipe – grooVed couplingSwww.victaulic.comVICTAuLIC IS A REgISTERED TRADEMARk oF VICTAuLIC CoMPANy. © 2013 VICTAuLIC CoMPANy. ALL RIghTS RESERVED. reV_odiMenSionSXZY WRemove to mate to ?at-faced ?anges.Vic-FlangeProper Gasket PositioningMatingFlangeAMax.BMin.Exaggerated for ClarityExaggerated for ClarityStyle 743grooved pipe adapter to ANSI Class 300 flangesSizeMax. work pressure *Max. end load * no. bolts † bolt/nut Size †Sealing Surfaceinches/mm dimensions – inches/mmapprox. wgt. eachnominal Size inchesmmactual outside diameter inchesmmpsi kpalbs.n required inches“A”Maximum“B”Minimum w X y zlbs. kg2 2.375 720 3,190 8 5/8 x 3 2.38 3.41 7.70 6.50 5.00 0.93 4.850 60.3 4960 14200 60 87 196 165 127 24 2.22 1/2 2.875 720 4,670 8 3/4 x 3 1/4 2.88 3.91 8.61 7.50 5.88 1.06 7.465 73.0 4960 20780 73 99 219 191 149 27 3.43 3.500 720 6,925 8 3/4 x 3 1/2 3.50 4.53 9.48 8.25 6.63 1.18 9.180 88.9 4960 30815 89 115 241 210 168 30 4.14 4.500 720 11,445 8 3/4 x 3 3/4 4.50 5.53 11.35 10.00 7.87 1.31 15.3100 114.3 4960 50930 114 141 288 254 200 33 6.95 5.563 720 17,500 8 3/4 x 4 5.56 6.72 12.31 11.00 9.25 1.43 17.7125 141.3 4960 77875 141 171 313 279 235 36 8.06 6.625 720 24,805 12 3/4 x 4 1/2 6.63 7.78 13.77 12.50 10.63 1.50 23.4150 168.3 4960 110380 168 198 350 318 270 38 10.68 8.625 720 42,045 12 7/8 x 4 3/4 8.63 9.94 16.68 15.00 13.00 1.68 34.3200 219.1 4960 187100 219 252 424 381 330 43 15.610 10.750 720 65,315 16 1 x 5 1/4 10.75 12.31 19.25 17.50 15.25 1.93 48.3250 273.0 4960 290650 273 313 489 445 387 49 21.912 12.750 720 91,880 16 1 1/8 x 5 3/4 12.75 14.31 22.25 20.50 17.75 2.06 70.5300 323.9 4960 408870 324 363 565 521 451 52 32.0* Working Pressure and End Load are total, from all internal and external loads, based on standard weight steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe.WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1 1/2 times the figures shown.Style 743 Vic-Flange must be ordered as a factory assembly when connected to a Victaulic fitting or valve. Contact Victaulic for details.† Total bolts required to be supplied by installer, may be ordered from Victaulic.Shaded area of mating face must be free from gouges, undulations or deformities of any type for effective sealing.06.06_7Vic-Flange® adaptersStyleS 741 and 74306.06carbon Steel pipe – grooVed couplingSwww.victaulic.comVICTAuLIC IS A REgISTERED TRADEMARk oF VICTAuLIC CoMPANy. © 2013 VICTAuLIC CoMPANy. ALL RIghTS RESERVED. reV_o1. The Style 741 (2 – 12"/50 – 300 mm) design incorporates small teeth inside the key shoulder I.D. to prevent rotation. These teeth should be removed when Vic-Flange adapter is utilized with a Victaulic Series 700 grooved end butterfly valve, Schedule 5 pipe or plastic pipe. Vic-Flange adapter Style 741 may only be used on one side of Victaulic Series 700 butterfly valve, sizes 2 – 4"/50 – 100 mm fitted with standard or latch-lock handles.2. Vic-Flange adapter must be assembled so it does not interfere with handle operation. Because of the outside flange dimension, Vic-Flange adapter should not be used within 90° of one another on a standard fitting. When wafer or lug-type valves are used adjoining a Victaulic fitting, check disc dimensions to assure proper clearance.3. Vic-Flange adapters should not be used as anchor points for tie-rods across nonrestrained joints. Mating rubber faced flanges, valves, etc. requires the use of a Vic-Flange washer.4. Area A-B noted in the above drawing must be free from gouges, undulations or deformities of any type for effective sealing.5. Vic-Flange adapter gaskets must always be assembled with the color coded lip on the pipe and the other lip facing the mating flange.6. Vic-Flange hinge points must be oriented approximately 90° to each other when mated.7. Flange Washers: Vic-Flange adapters require a smooth hard surface at the mating flange face for effective sealing. Some applications for which the Vic-Flange adapter is otherwise well suited do not provide an adequate mating surface. In such cases, it is recommended that a metal (Type F phenolic for Style 641 with copper systems) Flange Washer be inserted between the Vic-Flange adapter and the mating flange to provide the necessary sealing surface. Typical applications where a Flange Washer should be used are: a. When mating to a serrated flange: a flange gasket should be used adjacent to the serrated flange and then the Flange Washer is inserted between the Vic-Flange adapter and the flange gas-ket. b. When mating to a wafer valve: where typical valves are rubber lined and partially rubber faced (smooth or not), the Flange Washer is placed between the valve and the Vic-Flange adapter. c. When mating a rubber faced flange: the Flange Washer is placed between the Vic-flanges and the rubber faced flange. d. When mating AWWA cast flanges to IPS flanges: the Flange Washer or Transition Ring is placed between two Vic-Flange adapters with the hinge points oriented 90° to each other. If one flange is not a Vic-Flange adapter (e.g., flanged valve), then a flange gasket must be placed adjacent to that flange and the Flange Washer inserted between the flange gasket and the Vic-Flange adapter. Transition rings rather than Flange Washers must be used when mating Style 741 to Style 341 Flange Adapters in sizes 14 – 24"/350 – 600 mm. e. When mating to components (valves, strainers, etc.) where the component flange face has an insert: follow the same arrangement as in Application 1.When ordering Flange Washers, always specify product style (Style 741, 743, 341, 641, 994) and size to assure proper Flange Washer is supplied.Vic-Flange adapter noteS06.06_8Vic-Flange® adaptersStyleS 741 and 74306.06carbon Steel pipe – grooVed couplingSwww.victaulic.comVICTAuLIC IS A REgISTERED TRADEMARk oF VICTAuLIC CoMPANy. © 2013 VICTAuLIC CoMPANy. ALL RIghTS RESERVED. reV_owarranty Refer to the Warranty section of the current Price List or contact Victaulic for details.This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations.notegeneral noteS Style 741 and 743 Vic-Flange adapters provide rigid joints when used on pipe with standard roll or cut groove dimensions and consequently allow no linear or angular movement at the joint.Reference should always be made to the I-100 Victaulic Field Installation handbook for the product you are installing. handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com.inStallation06.06Vic-Flange® adaptersStyleS 741 and 743carbon Steel pipe – grooVed couplingSFor complete contact information, visit www.victaulic.com06.06 1534 reV o updated 01/2013VICTAuLIC IS A REgISTERED TRADEMARk oF VICTAuLIC CoMPANy. © 2013 VICTAuLIC CoMPANy. ALL RIghTS RESERVED. 06.06
Most popular related searches