Amcor
  1. Companies & Suppliers
  2. Amcor
  3. Downloads
  4. Amcor - D850E - Commercial Dehumidifier ...

Amcor - D850E - Commercial Dehumidifier Manual

DEHUMIDIFIERD850E D950EGB Instruction manual2GBFor safety reasons, read this information carefully before operating. Persons who are not familiar with this type of product must not use it. We strongly recommend keeping this information in a safe place for future reference.This appliance must be earthed and should only be connected to an earthed 220 – 240 V / 50 Hz mains. The installation must be in accordance with the regulations of the country where the unit is used.The unit is designated for indoor operation.• The dehumidifier is safe. However, as with other electrical appliance, use it with care.• Keep out of reach of children.• Do not clean the dehumidifier by spraying it or immersing it in water.• Do not insert any object into the opening of the dehumidifier.• Disconnect from the mains before cleaning the unit or any of its components.• Never connect to an electrical outlet using an extension cord. If an outlet is not available, one should be installed by a licenced electrician.• Any service other than regular cleaning or filter replacement should be performed by an authorized service representative. Failure to do so could result in a loss of warranty. SAFETYThank you for choosing this innovative Amcor dehumidifier. The instruction manual describes the many benefits and advanced features that this unique product has to offer. The Amcor dehumidifier is a large capacity unit designed to run highly efficiently in places such as: restaurants, bars, printing presses, indoor swimming pools, jacuzzis, garages, animal enclosures, cellars, stores, boat sheds, weekend cottages, archives, etc.For over 50 years, Amcor has specialised in complete indoor environment control, manufacturing: dehumidifiers, portable air conditioners, coolers, air purifiers/ionisers and aromatherapy products. These world class products incorporate the latest technological developments and are designed to create a quality environment.It is important that you read these instructions before using your new dehumidifier and we strongly recommend keeping them in a safe place for future reference.The first time that you use this dehumidifier please ensure that it has been standing for 24 hours in an upright position before it is switched on. THANK YOU3GBThis product is not made for DIY repairClose to a heat sourceIf the power cable wires are frayed or cutWhen small children may be left unattendedIf an extension cord is needed to reach an outletWhere the power cable may be damagedWhere it may be damaged by chemicalsWhere there is a risk of interference by foreign objectsIf there is a risk of liquid falling on the unitDo not use your dehumidifier under the following conditions:Your Amcor dehumidifier is supplied with an electrical cable and an earthed plug. Should it be necessary to replace this plug at any time, you must use an earthed electrical plug.Warning Never operate this appliance if it has a damaged cord or plug. If the supply cord is damaged, it must be replaced by an approved service representative or a similar qualified person in order to avoid any hazards.There should be direct access to the electrical plug after connecting the power HOW IT WORKSSee page 4, fig. 3Your Amcor dehumidifier controls the Relative Humidity by passing the air through the unit forcing the excess moisture to condensate over the cooling elements. This condensate water then flows safely into a fixed drain.The dried air then passes through a final heat exchanger where it is slightly warmed and re-enters the area at a slightly elevated temperature.The level of demoistering is set with the humidistat control.Reminder:Waste electrical products must not be disposed of with household waste.This product should be taken to your local recycling centre for safe treatment.4GB PARTSFilter??Fig. 2Dry airMoist airFanCompressorDrainage outletCooling elementsFig. 3Fig. 1Back coverWallFig. 51 234543Fig. 4126253345GBThere must be free space of at least 30 cm between any other object and the front and the top of the unit. Your Amcor dehumidifier can be installed in any area with a too high relative humidity, such as cellar, playing area, shed, archive or swimming pool.The dehumidifier will begin to protect from the harmful effects of excess moisture as soon as it is plugged in and switched on.When positioning your Amcor dehumidifier, ensure that it is placed on a level surface.Best results are obtained when windows and doors are closed, thus preventing the possible influx of fresh, too humid, air.When the unit is placed in a (swimming) pool, connect to the mains via a transformer or a breaking switch, conform the local regulations regarding electrical installations.When the dehumidifier is in operation, open outside doors and windows only when necessary. POSITIONING THE DEHUMDIFIERSee page 4, fig. 5The unit can stand on the floor or hung on a wall. All necessary items for wall mounting are supplied in the plastic bag. • Fix the supporting bracket with at least 5 screws horizontally to the wall, use the plugs for better fastening. • Hang the unit on the bracket, the two tongues fit into the slots on the unit’s rear panel. • Make sure the two rubber pads (3) on the tongues and the two rubber supports (4) on the lower part of the rear panel are properly placed. WALL MOUNTING6GBSee page 4, fig. 4ON/OFF (1)The unit is switched on and off by pressing the ON/OFF button (1). When the unit is on, the fan runs in the set speed.Humidity (2)Press the HUMIDITY button (2) repeatedly to choose the desired level of relative humidity in the area. The corresponding control lights (2) will indicate the selected percentage. The yellow CNT control light (5) indicates that the unit is running continuously, disregarding the relative humidity level in the area.Ventilator speed (3)Press the SPEED button (3) to select low or high speed. The corresponding control light (3) will indicate this, Lo=low or Hi=high.Digital display (4)The digital display (4) will show the measured relative humidity in the area.Compressor (6)The COMP control light (6) will be on when the compressor is running. An automatic time delay of five minutes before the compressor can (re-)start working is a safegarde against damage.IMPORTANT: This dehumidifier should not be used in temperatures below 7 °C or above 35 °C.Defrost ControlThe dehumidifier is equipped with an automatic de-icing mode to defrost the refrigeration coil during low temperature operation. The compressor is switched off whilst the ventilator continues to run. CONTROLS7GB DRAINAGE CLEANINGDisconnect from the mains before cleaning the unit or any of its components.See page 4, fig. 2Cleaning the air filterAir circulation is impeded and the efficiency of the dehumidifying and air purifying functions decreases when the filter is dirty. It is therefore good practice to clean the filter at regular intervals. The precise intervals depend on the room in which the appliance operates and on how frequently it is used. • Remove the filter (4) by sliding it out. • Clean the filter or wash in tap water. • Dry the filter before inserting it back.HousingWipe regularly clean with a moist cloth and mild household detergent.ServicingHave your dehumidifier once a year serviced by a qualified engineer.There are four optional outlets for the drainage tube. To change the outlet of the drainage tube the rear panel should be dismounted.When remounting the rear panel care should be taken to return all the screws and washers to their original location.Connecting the permanent outlet • Connect the pipe to an outlet tube with the correct diameter. • Push the other end of the tube into a drain, making sure that the tubing cannot be twisted or folded. • The entire length of the tube must be slightly inclined. • Ensure that the outlet of the drainage pipe is not under the water level in the drain.NOTE: In very cold weather conditions precautions should be taken to prevent the drainage pipe from freezing.8GBFor reference purposes only MOISTURE REMOVAL WIRING DIAGRAM9GB TECHNICAL DATAModel D850E D950EMains 230 V / 50 HzPower consumption W 850 1200Current (operation) A 4.5 6Current (at start) A 18 24Water extraction at 32 °C, 90 % RH L/24h 45 60Refrigerating agent R407CAirflow (at high fan speed) m3/h 500 680Operating temperature °C 7 – 35Dimensions w x h x d mm 660 x 750 x 345Weight (net) kg 39 44Meets EEC directive 73/23/CE (LVD). Specifications may change without prior notice. TROUBLE SHOOTINGIf the dehumidifier does not operate: • Make sure the unit is plugged in. • Ensure the humidistat control is turned on.If the unit is noisy: • Make sure the dehumidifier is standing solidly and level.If the unit is leaking: • Check the drainage tube for correct fitting. • Check for twists and bends in the drainage tube. • Check the drainage tube for a sufficient slope. • Check and make sure that the outlet of the drainage pipe is not under the water-level in the drain.ChinaShan Xia Industrial Development Zone,Heng Li Town, Dongguan City,Guangdong Province, ChinaPlant One - Amcor (China) LtdTel: +86 769 8372 1090Fax: +86 769 8372 1790Email: amcorcn@amcorgroup.comPlant Two - Amcor Appliances LtdTel: +86 769 8372 1970Fax: +86 769 8372 1790Email: amcorappl@amcorgroup.comHong KongAmcor LtdSuite 2007, Tower 6, The Gateway,Harbour City, 9 Canton Road,Tsim Sha Tsui, Kowloon,Hong KongTel: +852 2997 6865Fax: +852 2997 6091Email: amcorhk@amcorgroup.comUnited KingdomAmcor Ltd9 Ryan Drive, West Cross Centre,Great West Road, Brentford,Middlesex, TW8 9ER,United KingdomTel: +44 20 8560 4141Fax: +44 20 8232 8814Email: amcoruk@amcorgroup.comUSAAmcor Inc.685A Gotham Parkway, Carlstadt,New Jersey 07072,United States of AmericaTel: +1 201 460 8100Fax: +1 201 460 9481Email: amcorusa@amcorgroup.comThe NetherlandsAmcor B.V.Anton Philipsweg 9-11,1422 AL Uithoorn,The NetherlandsTel: +31 297 560 079Fax: +31 297 523 062Email: amcorex@amcorgroup.comIsraelAmcor International Ltd1 Sapir St.,P.O. Box 12001,Hertzelia Pituach,IsraelTel: +972 9 951 5351Fax: +972 9 958 5650Email: amcoril@amcorgroup.comSingaporeAmcor Investments (Singapore) Pte Ltd545 Orchard Road,#13-02, Far East Shopping Centre,Singapore 238882Tel: +65 6297 9881Fax: +65 6297 8891Email: amcorsg@amcorgroup.com
Most popular related searches