Banner Engineering Corp.
- Home
- Companies & Suppliers
- Banner Engineering Corp.
- Downloads
- Application note - leachate and ground ...
Application note - leachate and ground level monitoring
Banner Engineering Corp. 9714 Tenth Ave. No., Minneapolis, MN USA 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: sensors@bannerengineering.com
Water and Wastewater — Landfill Leachate and Ground Well Monitoring
Application
Solution
Leachate Collection and Removal
A single FlexPower™ Node equipped with a counter input and submersible
pressure sensor/transmitter can be used to reliably monitor both the leachate
level and the pump.
The submersible pressure transmitter monitors the leachate level while the
counter counts pump strokes used to remove that leachate.
When the FlexPower Node’s report rate is set to 16 seconds, a battery life
of several years can be achieved without sacrificing the reliability of the
monitoring system.
The sensor information is wirelessly transmitted from the Node to a
GatewayPro connected to a host system. The host system can store the data,
perform calculations, or notify personnel when a service vehicle is needed at a
specific well.
Ground Well Monitoring
Like the leachate level monitoring, ground well levels and removal must be
monitored and tracked. Again, submersible pressure transmitters are used to
determine the ground well water levels.
The pressure readings are collected by the FlexPower Node, which then
wirelessly transmits the data back to a Gateway Pro and host system for
tracking and analysis.
For difficult topologies, SureCross Data Radios can be used to transmit data
over obstructions and extend the range of the DX80 sensor network.
To meet governmental regulations, landfill managers need to accurately
measure and monitor the water levels within all ground wells in the landfill site
and monitor leachate accumulation and removal.
The ability to efficiently measure and collect data is an issue not only of
resource management but also of compliance and accountability to local,
state, and federal governmental organizations.
1
2
3
4
1 Pump used to remove the leachate or ground well water
2 Submersible pressure sensor
3 Methane reclamation pipe
4 FlexPower Node and DX81 Battery Supply Module
p/n 146126
SureCross™ Wireless Application Note
Most popular related searches