Thermo Scientific - Air Quality Instruments
  1. Companies & Suppliers
  2. Downloads
  3. PE Drainage Systems Brochure

AQ Model 43i Data Sheet (PDF 105 KB)

Product SpecificationsMMooddeell 4433i--TTLLEE EEnnhhaanncceedd TTrraaccee LLeevveell SSOO22 AAnnaallyyzzeerrPulsed fluorescence gas analyzer with enhanced communication capabilities fortrace level ambient air monitoring Analyze • Detect • Measure • ControlTMAA cchhaannggee iiss iinn tthhee aaiirrThe industry’s new best-of-breed. Ourcustomers told us exactly what they’relooking for in a gas monitoring solution:reliability, simplicity, ease of use. Thenew iSeries platform delivers on allcounts - and then goes a step farther.A core product in Thermo’s new iSeriesproduct line is the Model 43i -TLE SO2analyzer. Using pulsed fluorescence technology,the Model 43i -TLE measures the amountof sulfur dioxide in the air down to 50 ppt.The pulsing of the U.V. source lamp servesto increase the optical intensity whereby agreater U.V. energy throughput and lowerdetectable SO2 concentration are realized.Reflective bandpass filters, as comparedto commonly used transmission filters, areless subject to photochemical degradation and more selective in wavelength isola-tion. This results in both increased detec-tion specificity and long term stability.This state-of-the-art gas analyzer offersfeatures such as an ethernet port as wellas flash memory for increased data stor-age. Ethernet connectivity provides efficientremote access, allowing the user to down-load measurement information directlyfrom the instrument without having to beon-site.You can easily program soft-keys toallow you to jump directly to frequentlyaccessed functions, menus or screens Thelarger interface screen can display up tofive lines of measurement informationwhile primary screen remains visible. KKeeyy FFeeaattuurreess? Ethernet connectivity for efficient remote access? Enhanced user interface with one button programming and large display screen? Flash memory for increased data storage and user downloadable software? Enhanced electronics design optimizes product commonality? Improved layout for easier accessibility to componentsEnvironmental InstrumentsAir Quality Instruments27 Forge Parkway Franklin, MA 02038 USATakkebijsters 1Breda, 4817 BLThe Netherlands+1 (866) 282-0430+1 (508) 520-1460 fax+33 (0) 76 5879888+33 (0) 76 5816520 faxThis specification sheet is for informational purposes only and is subject to change without notice. Thermo makes no warranties, expressed or implied, in this product summary. © 2005 Thermo Electron Corporation. All rights reserved. Thermo Electron Corporation, Analyze. Detect. Measure.Control are trademarks of Thermo Electron CorporationLit _43iTLEEID_12/05Product SpecificationsPreset Ranges 0-10, 20, 50, 100, 200, 500 and 1000 ppb 0-20, 50, 100, 200, 500, 1000 and 2000 µg/m3Custom Ranges 0-10 to 1000 ppb0-20 to 2000 µg/m3Zero Noise 0.025 ppb RMS (300 second averaging time)Lower Detectable Limit 0.05 ppb (300 second averaging time)Zero Drift < 0.2 ppb per daySpan Drift +/-1% of full scale Response Time 80 seconds (10 second average time)Precision 1% of reading or 0.2 ppb (whichever is greater)Linearity +/-1% of full scale Sample Flow Rate 0.5 liters/min.Interferences < lower detectable limit except for the following: (EPA levels) NO: Reads < 3 ppb when tested at 500 ppb. M-Xylene: Reads < 1 ppb when tested at 200 ppb. H2O: Reads < 2% of reading when tested at 2% H2O absoluteOperating Temperature 5OC - 40OC (20OC - 30OC with EPA Designation)Power Requirements 100 vac, 115 vac, 220-240 vac +/-10% @ 165WSize and Weight 16.75”(W) x 8.62”(H) x 23”(D), 48 lbs. 425 mm (W) x 219 mm (H) x 584 mm (D), 21.8 kgOutputs Selectable Voltage, RS232/RS485, TCP/IP, 10 Status Relays, and Power Fail Indication (standard). 0-20 or 4-20 mA Isolated Current Output (optional)Inputs 16 Digital Inputs (standard), 8 0-10vdc Analog Inputs (optional)Model 43i -TLE SO2 Analyzer Choose from the following configurations/optionsto customize your own Model 43i-TLEVoltage options:A = 115 Vac 50/60 Hz B = 220/240 Vac 50/60 HzJ = 100 Vac 50/60 HzInternal zero /span:N = No zero / span assembly Z = Internal zero / span assemblyP = Internal permeation span source with zero/span assemblyKicker type:S = StandardH = HeatedOptional I/O:A = No optional I/O (standard)C = 0-20, 4-20mA current output - 6 channels, 0-10v analog input - 8 channelsMounting hardware:A = Bench mounting (standard)B = Ears & handles, EIAC = Ears & handles, retrofitOrdering Information YYoouurr OOrrddeerr CCooddee:: 4433iTLE -- ____ ____ ____ ____ ____ www.thermo.com/airComprehensive Service SolutionsTo maintain optimal product performance, you need immediate access to experts worldwide, as well as priority status when yourair quality equipment needs repair or replacement. Thermo Electron offers comprehensive, flexible support solutions for all phasesof the product lifecycle. Through predictable, fixed-cost pricing, Thermo services help protect the return on investment and totalcost of ownership of your Thermo Electron air quality products.Other options:? Teflon particulate filer ? Cable, DB37M to open end, 6' LG.? Rack mounts ? Cable, DB37F to open end, 6' LG.? Rear extender ? Cable, DB25M to open end, 6' LG.? Terminal Block Kit & Cable 37 pin ? Cable, RS232 Null Modem? Terminal Block Kit & Cable 25 pin
Most popular related searches