Teledyne Tekmar
AQUATek - 70 - Vial Autosampler - Brochure
© Teledyne 2008. All rights reserved.Have questions? Need help?Our friendly sta? of trained sales and service personnel are a call or click away.Product DescriptionThe AQUATek 70 utilizes a ?xed volume sample loop that is ?lled during the vial pressurization step. Internal standard is added and the sample is transferred to the concentrator for analysis. The system then ?ushes the entire sample pathway with hot dionized water for cleaning and preparation of the next sample.Methods• USEPA 5030 in conjunction with 502.1, 502.2, 524.2, 503.1, 601, 602, 603, 624, 8010, 8015, 8020, 8021, 8030, 8240 and 8260AQUATek 70Waters-only AutosamplerWater autosampler for purge and trap concentrators70 sample positionsRobust needle-to-vial designAutomatic internal standard additionAuto-rinse between sample minimizing carryoverTe?on® or PEEK® sample path optionsStandard loop sizes available: 5, 10, 20 and 25 mLTekLink software controlWhen used with a Stratum PTC or Velocity XPT concentrator, additional diagnostics features, including leak check, are availableThe system is also compatible with earlier Teledyne Tekmar models, such as the 3000 and 3100 Series concentratorsAQUATek 70Speci?cations Sample Vials: Nominal 40 mL capacity, single hole cap with Teflon® faced silicone septum, per EPA specifications. 3 3/4” (9.5 cm) high, 1 1/16” (2.7 cm) O.D., 24 mm ID cap for water sampling. Trays: Accepts either two 35 position trays or one optional 70 position vial cooling tray Vial Cooling: Optional vial cooling tray to cool vials to 4º C as per EPA specifications. (Requires an external recirculating cooling bath) Bath Connection: Inlet and outlet hose connections require 1/4” (0.64 cm) I.D. tubing. Bath must have a minimum cooling capacity of 300 watts. Sample Types: Drinking water and wastewater (water samples containing sediment levels of up to 15 mm when measured from the bottom of an upright 40 mL vial) Sample Loop: Interchangeable loops; 5 or 25 mL volume, 1/8” (0.32 cm) O.D. coiled Standard Injection System: 4-way valve, 2 µL volume delivery Internal Standard Accuracy: 2 µL +/- 10% Internal Standard Consumption: 11 µL at 0.02min Fill IS; 16 µL at 0.04 min Fill IS Electronic Control: Concentrator control of optically isolated I/O Instrument Control: AQUATek 70 is controllable with a PC running TekLink software in a Windows environment. TekLink integrates control of the 3000 Series Purge & Trap with the AQUATek 70. Method Storage: Up to 16 methods including pre-programmed methods. Vial Sampling Device: XYZ robot with stationary vial rack design capable of an accuracy of +/- 1 mm in XYZ dimensions and repeatability of +/- 0.25 mm in XYZ dimensions. High Temperature OptiRinse: AQUATek 70 uses dual internal reservoirs, which heat the water to 90º C to clean the entire sample pathway. (Includes sample loop, sample pathway, and glassware on the concentrator) Rinse Kits: AQUATek 70 requires either a tap rinse kit or a reservoir kit. These do not add additional width so bench space used is not increased. Sample Path: 1/8” (0.32 cm) O.D. Teflon tubing Valving: Four 12VDC, 3 port solenoid valves; One 115 VAC motor actuated 4-port valve Size: 11” (27.9 cm) W x 10” (25.4 cm) H x 10.5” (26.7 cm) D Weight: Interface: 15 lbs (6.8 kg) shipping weight; Autosampler: 120 lbs (54.4 kg) shipping weight Warranty: One year full warranty. Certifications: CETL, CE, CSA System Requirements Power Requirements: 100/115/230 VAC (+/- 10%) factory configured; 50/60 HZ, 100VA Environment Requirements: Operating temperature: 10ºC to 30ºC; Storage temperature: -20ºC to 60ºC; Relative humidity: 10 to 90% with no condensation Gas Requirements: Ultra high purity (99.999% pure) Helium or Nitrogen, 25-60 psi
Most popular related searches
