Aquron Corporation
- Home
- Companies & Suppliers
- Aquron Corporation
- Downloads
- Aquron 3000-CBP
Aquron 3000-CBP
©Copyright 2011 Aquron Corporation All rights reserved.MANUFACTURERAQURON® Corporation International Post Office Box 758Rockwall, Texas 75087 U.S.A972-722-5444 Phone972-722-6412 Fax800-342-4649 Toll Free888-412-1543 Toll Free FaxE-Mail: info@aquron.comWebsite: www.aquron.comPRODUCT DESCRIPTIONAQURON® CBP-3000™ is a clear aqueous borne com-pletion treatment for (CFM) concrete block, fluted con-crete block, split face concrete block and other large vol-ume porosity concrete products.BASIC USEAQURON® CBP-3000™ is a permanent and clear treat-ment/preservative/sealant solution for concrete block, fluted concrete block, split face concrete block and other large vol-ume porosity concrete product. AQURON® CBP-3000™ is a highly reactive catalytic agent, which reacts with free alkali and/or alkaline hydrates by internally producing a silica hydro-gel which fills the pore spaces and the voids around aggre-gate. Furthermore, alkali is converted to a neutral compound structure, reducing the potential for internal chemical reac-tions. More density is added, additional bonding strength is provided and concrete is permanently hydrostatically sealed from within. AQURON® CBP-3000™ is an ideal primer for concrete block surfaces that are to receive paint or other coatings since it enhances the bonding quality of the surface. AQURON® CBP-3000™ prevents peeling, cracking and loss of bond caused by capillary moisture or internal chemical reactions that can cause saponification. AQURON® CBP-3000™ will not alter the appearance of the surface or physical characteristics and will enhance sur-face traction quality. The use of AQURON® CBP-3000™ will significantly pro-tect concrete block from damages (spalling, etc.,) caused by freeze-thaw cycles, especially where salt or calcium chloride has been used for ice removal. AQURON® CBP-3000™ will arrest or at least severely retard concrete block etc., being deteriorated by alkaline aggregate reactions (AAR). In addition, by treating concrete block not yet affected, the potential will be virtually eliminat-ed.SOME ATTRIBUTES• Waterproofs • Seals matrix • Prevents internal water migration • Zero VOC/VOS content SOME ATTRIBUTES CONT...• Hardens surface • Stays pliable • Application is permanent • Adds density and bonding strength • Adds abrasion resistance • Resists freeze-thaw spalling • Improves thermal resistance • Improves adhesion of topicals • Improves past carbonation effects • Improves acid/chemical resistance • Increases surface abrasion resistance • Increases strength • Lowers internal chemical reaction potential • Lowers creep potential • Lowers electrostatic discharge potential • Seals weeping concrete by spraying on • Retards dusting • Non-toxic • Non-flammable • Neutralizes internal corrosives • Severely retards capillary action • Impervious to most atmospheric contaminates • Excellent pre-treatment for coating systems • Makes ice removal/cleaning easier • Deeply penetrating 2”-3”/50-75mm • Able to clean equipment using only water Precautions• Spills or spray droplets in contact with glass should be removed immediately by flushing with water. DO NOT ALLOW TO DRY, as etching can occur. • Some discoloration of polished aluminum can occur. • Do not apply AQURON® CBP-3000™ when air and/or sub-strate temperatures are less than 37oF/2.8oC and will not decrease to less than 37oF/2.8oC for 6 hours.• For proper seal, concrete block should have 8% to 12% cementitious (Portland Cement) content.Applicable StandardsAQURON® CBP-3000™ meets or exceeds the following standards: • ASTM C-67 Section 7 - Water absorption • ASTM-67 Section 9 - Suction • ASTM C-67 Section 10 - Efflorescence • ASTM C-666 - Freeze-thaw resistance • ASTM C-23-69 - Artificial weathering • ASTM C-666 - Salt attack resistance • AASHTO T260 - Chloride ion content • AASHTO T259-78 - Chloride ion penetrations • USDA Approved for use in food processing areas • VOC/VOS Compliant Proven Since 1985Concrete Block Preservation TreatmentMASONRY AND STONE ENHANCEMENTAQURON® CBP-3000™CompositionAQURON® CBP-3000™ is a highly reactive catalytic agent in a water borne proprietary silicate base which produces a silica-hydro gel below the surface and inside the matrix.InstallationJOB CONDITIONS1. Do not proceed with application of AQURON® CBP-3000™ when ambient temperature and/or substrate temperatures are less than 37oF/2.8oC or forecasted to drop below 37oF/2.8oC during the next 6 hours follow-ing application. 2. Should temperatures be extremely hot, cool surface with sufficient water to decrease temperature. 3. Caution should be taken in windy conditions as AQURON® CBP-3000™ if allowed to dry on glass can etch (flush immediately with water should contact with glass occur). 4. As a deeply penetrating water borne product, AQURON® CBP-3000™ must have access to the surface. Any pre-vious coatings or heavy build-ups of oil, grease, or atmospheric pollution must be removed.ApplICATION prOCeDure1. Coverage rate is 1.17m2 - 2.3m2 per liter / 50-100 sq. ft. per gallon depending on porosity size. 2. Application is to be made with low pressure spray equipment with tip size of .026 to .072 (pump-up garden sprayer with fan tip – DO NOT ATOMIZE) 3. Always start application at lowest possible area first and proceed to the higher elevations. On vertical appli-cations (walls) start at bottom and proceed up the surface. 4. Holding spray tip 6”-12”/150mm-300mm from surface using overlapping spray pattern and fanning motion at the end of each pass.5. When application is to a weeping hydrostatic wall it is recommended a second application be applied, sec-ond coat should be applied immediately following the first application with no longer than 20 minutes between applications. Do not allow first application to dry before second application is applied. 6. Should impurities appear on surface from the purging action of AQURON® CBP-3000™ before application is dry, but no sooner than 10 minutes after application. RINSE surface with sufficient potable water to remove impurities (LOW PRESSURE ONLY). 7. Surface can be opened for traffic immediately following application. Caution must be taken as treated surface may be slippery until completely cured If surface is to be covered with a coating or adhesive let surface air dry completely (24-72 hours or more, depending on temperature and humidity conditions).Clean-up and SafetyNo special clothing, breathing apparatus, goggles or gloves are necessary, but in enclosed areas it is advisable to wear an appropriate respirator to avoid possible irritation to breathing. Attention should be made to watches, eyeglasses etc., as AQURON® CBP-3000™ can etch glass or discolor aluminum if allowed to dry. Clean all equipment using water and mild soap. Never store spray equipment without cleaning and following manu-facturer’s recommendations for storage between usage.Attention should be made to watches, eyeglasses etc., as AQURON® CBP-3000™ can etch glass or discolor alu-minum if allowed to dry.Shelf LifeSelf-life is indefinite provided containers are kept tightly sealed when not in use.PackagingAQURON® CBP-3000™ is available in 5 gallon/18.9 lit-ers and 55 gallon/208.2 liters drum size.AQURON® CBP-3000™ is also available in bulk con-tainers.MaintenanceSpecial maintenance of treated area is not required.Technical ServicesTechnical information and assistance may be obtained from your local dealer, or by calling the technical department of the AquRoN Corporation at (972) 722-5444, (800) 342-4649 office, or (972) 722-6412 FAX or toll free FAX (888) 412-1543. E-mail welcome –info@aquron.com©Copyright 2011 Aquron Corporation All rights reserved.Warranties and limitations of liabilityAquron Corporation (“Seller”) warrants that if any goods supplied prove defective in work-manship or materials, that Seller shall replace them or refund their purchase price. Aquron Corporation offers a performance warranty for this Aquron® product. The warranty for the performance of this Aquron® product must be requested from the Aquron Corporation and initiated prior to applying this Aquron® product. Failure to initiate warranty of performance prior to application, holds harmless Aquron Corporation of any liability arising from its use, and user assumes all risk and liabilities whatsoever in connection therewith. The terms of this paragraph may not be orally modified. There are no warranties express or implied which extend beyond the face herewith.local Area representative
Most popular related searches
