bioMérieux S.A.
- Home
- Companies & Suppliers
- bioMérieux S.A.
- Downloads
- BacT/ALERT 3D Microbial Detection ...
BacT/ALERT 3D Microbial Detection Systems Brochure
The same user-friendly approachfor data management ensures optimum flexibility bioMérieux S.A.69280 Marcy l’EtoileFranceTel.: 33 (0)4 78 87 20 00Fax: 33 (0)4 78 87 20 90Manufactured by :bioMérieux Inc.100 Rodolphe Street,Durham, NC 27712 USATel. : 00 1 919 620 2000 Fax. : 00 1 919 620 2211LISLISLISOBSERVALISOBSERVAorororbioMérieux Inc. is a wholly-ownedsubsidiary of bioMérieux SA.BacT/ALERT® 3D offers you the data management option which best suits your unique laboratory organization. Each option has virtually the same graphical, text-free, touch-screen user interface.SelectTMThe standard solution for routine microbial testing wheresophisticated data managementand Laboratory Information System(LIS) connectivity are not needed.SelectLinkTMThe ideal solution for routine microbialtesting where a bi-directional LISinterface is required to exchangepatient data and results.SignatureTMThe high-performance solution when extensive data managementcapabilities are required. This is possible through the LISinterface and the OBSERVA® software package.02-13 / 002GB99048D/ This document is not legally binding. bioMérieux reserves the right to modify specifications without notice / BIOMERIEUX the blue logo, OBSERVA, BacT/ALERT® are used, pending and/or registeredtrademarks belonging to bioMérieux SA or one of its subsidiaries / bioMérieux SA RCS Lyon 673 620 399 / Photos A. Guillemaud / Printed in France / THERA Conseil/ RCS Lyon B 398 160 242www.biomerieux.comwww.biomerieux-diagnostics.comBeing first, being smarterA smart and modular design makes BacT/ALERT® 3D themost compact automated microbial detection systemaround.Introduced in 1990, over 10,000 BacT/ALERT systems havebeen installed worldwide to perform blood culture, bodyfluid culture and/or mycobacterial testing.Specific colorimetric technology with visual positive signal.BacT/ALERT 3D meets all your volume requirements - simplychoose the number of modulesrequired based on your laboratorytesting volume.The same high-performancetechnology ensures safetyand time-savingsModule7,00014,00021,00028,00035,00044,00056,000 70,00084,000The operator uses the touch-screen for text-free controlover the system while barcode-scanning the bottle ID before loading. The added bonus of this simplified handling procedureis that training is kept to a minimum.The same - Touch, Wand, Load - proceduresimplifies your daily workload The BacT/ALERT 3D expandable design enables you to add additional testing capacity as you need it.Its stackable modules can be arranged tosave space and accommodate any laboratory layout. Occupying one third of the space of othersystems, BacT/ALERT 3D is the mostcompact microbial detection systemavailable.Each individual module can be configured to perform either bloodculture, body fluid and/ormycobacteria testing.The same flexible systemdesign adapts to yourlaboratory requirements TouchWandLoad* Five day protocol.All BacT/ALERT® 3D systems share the same time-proven technology and easy-to-use design, making them the most reliable partner for your laboratory.The patented colorimetric detection system, based on sophisticated algorithms are designed to detect microorganismsearly, even with delayed entry. Each cell is equipped with a patented cell flag, ensuring instantbottle recognition and automated quality control.Continuous monitoring gives immediate notification of resultswith instant visual and audible alerts, including a remote alarmcapability. User-directed bottle loading greatly facilitates the workflow.Annual bottlevolume*Unloaded Weight : 90.7 Kg (200 lbs)Loaded Weight : 95 Kg (210 lbs)Controller Module This module enables up to 6 IncubationModules to be operated from one set ofelectronics and integrated computer hardware.Incubation ModuleFour incubation drawers of 60 cells giving a total capacity of 240 cells. Eachdrawer has an independent shaking mechanism, enabling static or shaken cultures within the same system.SpecificationsUnloaded Weight : 119 Kg (262 lbs)Loaded Weight : 139 Kg (295 lbs)49.6 cm(19.5 inches)91.4 cm (36 inches)61.7 cm(24.3 inches)Combination ModuleIt combines all the BacT/ALERT® 3D capabilities in a surprisingly compact format : a control and Incubation Modulein a single instrument to perform bloodculture, body fluid and/or mycobacteriatesting. Each module has a total incubation capacity of 120 cells (2 drawers) but canalso connect to up to 3 Incubation Modules.••••••49.6 cm (19.5 inches)78.1 cm (30.8 inches)62.2 cm(24.5 inches)••••••Electrical Power Services Requirements• 100/120 Volts (50-60 HZ)• 220/240 Volts (50-60 HZ)Power Consumed in Watts• @115 V.A.C. 72 Watts typical• @230 V.A.C. 72 Watts typicalHeat Dissipated• 245 Btu/Hr. 2840 maximumSound Emission• 46.4 dBEnvironmental Requirements• Operating Temperature Range10°C to 30°C(50°F-86°F)• Operating Humidity Range10% to 90% relativehumidity, non-condensingSpecificationsCapacity• 120 cells (60 cells/drawer)Electrical Power Services Requirements• 100/120 Volts (50-60 HZ)• 220/240 Volts (50-60 HZ)Power Consumed in Watts• @115 V.A.C. 256 Watts (idle), 640 Watts typical• @230 V.A.C. 265 Watts (idle), 640 Watts typicalHeat Dissipated• 904 Btu/Hr. 2840 maximumSound Emission• 55.5 dBEnvironmental Requirements• Operating Temperature Range10°C to 30°C(50°F-86°F)• Operating Humidity Range 10% to 90% relativehumidity, non-condensingSpecificationsCapacity• 240 cells (60 cells/drawer)Electrical Power Services Requirements• 100/120 Volts (50-60 HZ)• 220/240 Volts (50-60 HZ)Power Consumed in Watts• @115 V.A.C. 256 Watts (idle), 640 Watts typical• @230 V.A.C. 265 Watts (idle), 640 Watts typicalHeat Dissipated• 904 Btu/Hr. 2840 maximumSound Emission• 54.7 dBEnvironmental Requirements• Operating Temperature Range 10°C to 30°C(50°F-86°F)• Operating Humidity Range10% to 90% relativehumidity, non-condensingWeight : 41 Kg (91 lbs)35.6 cm (14 inches)91.4 cm (36 inches)61.7 cm (24.3 inches)••••••
Most popular related searches
