BAMO Mesures SAS
BAMOPHOX - 106 - pH-meter & ORP-Meter Brochure
- pH/ORP programmable monitor andregulator- Alphanumeric back lighted LCD display- Friendly using menu- Scales: 0 - 14 pH and ± 1000 mVthrough configuration- Temperature compensationAutomatic or manual- 2 analogical outputs 0/4-20mAgalvanic insulated- 4 relay outputs (Normally Open contacts)- 1 input to switch the regulation on Stand-by- 2 models available:Panel mounting 72 x 144Wall mounting IP 65- OPTIONS: RS 422 /J-BUS + LOGGER Extension for 2nd measurement input EXTENSION TERMINALAn extension terminal (wall, panel mounting or DIN rail mounting):- Allows a second measurement parameter (pH, Conductivity, Chlorine, Turbidity, Flow, and 4-20 mA, depending of the model)- The data from this blind device are displayed on the main device (second line display).- A 4 wires shielded cable is necessary to link both devices(maximum length of 500m)- The options RS422 and the data logger are shared between both Bamophox. DESCRIPTIONThe BAMOPHOX 106 offers high flexibility on use mixing different built-inprogrammes for regulation, thresholds, temperature compensation, andalarms. The 2 lines back lighted display, 16 alphanumerical characters, givesan easy measurement and temperature reading in any conditions. It alsodisplays the configuration menu and settings of thresholds, analogical outputs,operation data modes, calibration steps. To allow a quick and easy diagnosticafter configuration a simulation program is built-in with direct actuation oncontacts outputs, analogical outputs and PID regulation. A copy of the signal onthe 4-20 mA output is galvanic insulated; it can be set up within the all range ofthe parameter. Temperature measurement is also available on a 4-20 mAoutput (this output is not available when PID regulation is in use).pH/mV meterBAMOPHOX 106pH106-01/110611-05-2010 106 I1 01 DpH/mV meterBAMOPHOX 106Wall mountig (main device)DIN Rail mounting(extension)Main device+ extension(Example: Flow)=Panel mounting (main device)Maximum cable length: 500 meterTECHNICAL FEATURESDisplayed parameters: Measurement values pH/ORP - Configuration Menu - Temperature valueDisplay: Back lighted - 2 lines of 16 alphanumerical characters ; 9,2 mm highIndication: LED alarms status Configuration: 8 push buttons keyboard on front face - Keyword protectedScales: 0 to 14 pH pH–meter configuration / ±1000 mV ORP–meter configurationAccuracy: ± 0,03 pH or ± 3 mVInput impedance: >1013 OProbe input: coaxial connector, code 9054Temperature compensation: Automatic with an input for a 3 wires Pt 100 Ohm/0°C range, 0…100°CManually from 0…100°CRelay outputs: 4 closing contacts (Silver alloy), voltage freeThresholds: 3 programmable independent thresholds - with adjustable hysteresis 0…100% - and adjustable timer from 0 to 9999 secOutput relay (S4) Common alarm signal for: - Too long injection - Temperature out of range: - pH>14 or open loop- Pt 100 O dysfunction or probe cleaning functionContact: Initial resistance 100 mO as a maximum (voltage drop 6 V DC 1 A) Rated at 831 V AC / 3 A / 277 V AC ; 90 W / 3 A / 30 V DC Switching capacity (minimum) 100 mA, 5 V DC (depending of switching frequency, ambient conditions, accuracy)Mechanical life time (minimum) 5 x106 operations (180 commutation/min)Electrical life time (minimum) 2 x105 (20 comm./min) [3 A, 125 V AC], [3 A, 30 V DC] and 105(evaluated charge) for 3 A, 125 V ACON/OFF Regulation: Pulse time 0…9999 sec - High and low proportional bandwidth, high and low dead zone.PID Regulation: Proportionality 0…200%, - Integrant and Derivative: 0…999 secondCalibration sequence: Regulation on standby, relay outputs inhibited, analogical outputs stand on last valuesSelf-cleaning program: Frequency and duration settings, with regulation inhibited and analogical outputs standing on last valuesMeasurement output: 0/4-20 mA (maxi 600 O) proportional to measurement, galvanic insulatedTemperature output / PID: 0/4-20 mA (max 600 O), scaling 0…100°C, galvanic insulatedProgram Testing: simulation through the menu on measurement, temperature, PID and relays outputsMain power supply: 230 V AC / 50-60 Hz [other on request] - Consumption 10 VAModels: Panel mounting, IP65, 72 x 144 mm, connections on screw terminal IP40Idem DIN Rail mounting, only for blind monitorWall mounting, IP65, cable glands, connections on screw terminalOPTION (RS 422 + Logger) Communication: RS422 output, J-BUS link, binary slave mode, 2400 to 9600 baudsData Logger: Cycle average measurement record, with a programmable period, 150000 records maxi on MMC (multi media card) / External driver necessaryDIMENSIONSExtension terminal:identical to the panelor wall mountingpH/mV meterBAMOPHOX 10611-05-2010 106 I1 01 D106pH106-01/2106CODES AND REFERENCESCode Reference Designation106 500 BAMOPHOX106 E Panel mounting 72 x 144 - IP 65 front panel - screw terminal IP40106 501 BAMOPHOX106 E/A Panel mounting 72 x 144 / Extension blind monitor - screw terminal IP40106 503 BAMOPHOX106 D/A DIN Rail mounting / Extension, blind monitor - screw terminal IP40106 550 BAMOPHOX106 E LOG BUS Panel mounting 72 x 144 / RS422 + logger - IP 65 front panel - screw terminal IP40 106 800 BAMOPHOX106 M Wall mounting - IP 65 - cable glands, connections on screw terminal 106 801 BAMOPHOX106 M/A Wall mounting - IP 65 / Extension, blind monitor - cable glands, connections on screw terminal 106 850 BAMOPHOX106 M LOG BUS Wall mounting - IP 65 / RS 422 + LOGGER - cable glands, connections on screw terminalPANELWall mounting instrumentPanel mounting instrument
Most popular related searches
