Camfil UK Ltd
  1. Companies & Suppliers
  2. Camfil UK Ltd
  3. Downloads
  4. Basic-Flo - Green - Bag Filters ...

Basic-Flo - Green - Bag Filters Synthetic Media - Datasheet

Com fo r t f i l t e r s : M5 t o F9Bag F i l t e r sAs part of our continuous improvement, Camfil reserve the right to change specifications without notice. 2013-01-28Basic-Flo GreenAdvantagesE F FG UAArt. Nr.AACABCAGAGCGABCAGAG* ME%: M* Energy* Energywww.camfil.comApplications: Filtration of fresh air or recirculated air in the climate controlled spacesType: Multi pocket bag filterFrame: Plastic frame, 25 mmMedia: Synthetic fiber.EN779:2012 efficiency: M5, M6, F7.Recommended final pressure drop: 450 Pa (suggested economical change point 250 Pa).Maximum air flow: 1,25 x norminal air flowTemperature / Humidity: 70ºC maximum in continuous serviceRemarks: Also available with metal frame, 25mmDD 25WHI C I E N C YR A N T E EEN 779:201EN 779:2012 TESTED ACCORDING TO • Ekonomy version • Optimized filter area with conical filter bags• Quick and easy mounting• IncinerableType Width Height Depth Filter classAir flow m3/hPressure drop BagsArea m2 Volume m3 Weight kg Initial eff. %ME %Energy classEnergy consumption kWh/yAG5 C 592 592 600 M5 3400 50 6 4,5 0,05 2,4 19 6,6 C 859CG5 C 490 592 600 M5 2800 50 5 3,6 0,05 2,1 CCG5 C 287 592 600 M5 1700 50 3 2,3 0, 035 1,5 CG5 63 C 592 287 600 M5 1700 50 6 2,3 0, 035 1,50 CG5 65 C 592 490 600 M5 2800 50 6 3,6 0,050 2,10 CG5 33 C 287 287 600 M5 800 50 3 1,1 0,020 0,80 CG5/520 D 592 592 520 M5 3400 55 6 3,7 0,050 2,00 17 6,6 D 963 G5/520 D 490 592 520 M5 2800 55 5 3 0,050 1,80 DG5/520 D 287 592 520 M5 1700 55 3 1,8 0, 035 1,20 D5 63/520 D 592 287 520 M5 1700 55 6 1,8 0, 035 1,20 D5 65/520 D 592 490 520 M5 2800 55 6 3 0,050 1,80 D5 33/520 D 287 287 520 M5 800 55 3 0,9 0,020 0,70 DG5/370 G 592 592 370 M5 3400 60 6 2,6 0,050 1,80 11 6,6 G 1 556 G5/370 G 490 592 370 M5 2800 60 5 2,2 0,050 1,60 GG5/370 G 287 592 370 M5 1700 60 3 1,3 0, 035 1,20 G5 63/370 G 592 287 370 M5 1700 60 6 1,3 0, 035 1,20 G5 65/370 G 592 490 370 M5 2800 60 6 2,2 0,050 1,60 Ginimum efficiency ref. to EN779:2012 Consumption, kWh/year: Calculated according to Eurovent Guideline 4/11 class: Calculated according to Eurovent 4/11Comfo r t f i l t e r s : M5 t o F 9Bag F i l t e r sCG5 33/370 G 287 287 370 M5 800 60 3 0,6 0,020 0,70 GAG6 F 592 592 600 M6 3400 60 6 4,5 0,050 2,40 11 6,6 F 1 447 AACABCAGAGCABCAGAGCABCAGAGCAGAGCArt. Nr. Type Width Height DepthFilter classAir flow m3/hPressure drop BagsArea m2 Volume m3 Weight kg Initial eff. %ME %Energy classEnergy consumption kWh/y* ME%: M* Energy* EnergyAs part of our continuous improvement, Camfil reserve the right to change specifications without notice. 2013-01-28www.camfil.comBG6 F 490 592 600 M6 2800 60 5 3,6 0,050 2,10 FCG6 F 287 592 600 M6 1700 60 3 2,3 0, 035 1,50 FG6 63 F 592 287 600 M6 1700 60 6 2,3 0, 035 1,50 FG6 65 F 592 490 600 M6 2800 60 6 3,6 0,050 2,10 FG6 33 F 287 287 600 M6 800 60 3 1,1 0,020 0,80 FG6/520 G 592 592 520 M6 3400 65 6 3,7 0,050 2,00 34 23 G 1 803 G6/520 G 490 592 520 M6 2800 65 5 3 0,050 1,80 GG6/520 G 287 592 520 M6 1700 65 3 1,8 0, 035 1,20 G6 63/520 G 592 287 520 M6 1700 65 6 1,8 0, 035 1,20 G6 65/520 G 592 490 520 M6 2800 65 6 3 0,050 1,80 GG6 33/520 G 287 287 520 M6 800 65 3 0,9 0,020 0,70 GG6/370 G 592 592 370 M6 3400 85 6 2,6 0,050 1,80 32 23 GG6/370 G 490 592 370 M6 2800 85 5 2,2 0,050 1,60 GG6/370 G 287 592 370 M6 1700 85 3 1,3 0, 035 1,20 G6 63/370 G 592 287 370 M6 1700 85 6 1,3 0, 035 1,20 G6 65/370 G 592 490 370 M6 2800 85 6 2,2 0,050 1,60 GG6 33/370 G 287 287 370 M6 800 85 3 0,6 0,020 0,70 GG7 C35+ 592 592 600 F7 3400 120 6 4,5 0,050 2,40 76 35 C 1 468 G7 C35+ 490 592 600 F7 2800 120 5 3,6 0,050 2,10 CG7 C35+ 287 592 600 F7 1700 120 3 2,3 0, 035 1,50 CAG7 63 C35+ 592 287 600 F7 1700 120 6 2,3 0, 035 1,50 CAG7 65 C35+ 592 490 600 F7 2800 120 6 3,6 0,050 2,10 CCG7 33 C35+ 287 287 600 F7 800 120 3 1,1 0,020 0,80 CAG7/520 D35+ 592 592 520 F7 3400 135 6 3,7 0,050 2,00 70 35 D 1 782 BG7/520 D35+ 490 592 520 F7 2800 135 5 3 0,050 1,80 DCG7/520 D35+ 287 592 520 F7 1700 135 3 1,8 0, 035 1,20 D7 63/520 D35+ 592 287 520 F7 1700 135 6 1,8 0, 035 1,20 D7 65/520 D35+ 592 490 520 F7 2800 135 6 3 0,050 1,80 DG7 33/520 D35+ 287 287 520 F7 800 135 3 0,9 0,020 0,70 DAG7/370 G35+ 592 592 370 F7 3400 185 6 2,6 0,050 1,80 67 35 G 2 566 BG7/370 G35+ 490 592 370 F7 2800 185 5 2,2 0,050 1,60 GCG7/370 G35+ 287 592 370 F7 1700 185 3 1,3 0, 035 1,20 G7 63/370 G35+ 592 287 370 F7 1700 185 6 1,3 0, 035 1,20 G7 65/370 G35+ 592 490 370 F7 2800 185 6 2,2 0,050 1,60 GG7 33/370 G35+ 287 287 370 F7 800 185 3 0,6 0,020 0,70 Ginimum efficiency ref. to EN779:2012 Consumption, kWh/year: Calculated according to Eurovent Guideline 4/11 class: Calculated according to Eurovent 4/11Com fo r t f i l t e r s : M5 t o F9Bag F i l t e r sAs part of our continuous improvement, Camfil reserve the right to change specifications without notice. 2013-01-28UFG7 C35+ 592 592 600 F7 3400 110 8 6 0,050 2,60 77 35 C 1 502 UGG7 C35+ 490 592 600 F7 2800 110 6 4,5 0,050 2,40 CUHUUUUUUU5U5U5UUUU3U3U3Art. Nr. Type Width Height DepthFilter classAir flow m3/hPressure drop BagsArea m2 Volume m3 Weight kg Initial eff. %ME %Energy classEnergy consumption kWh/y* ME%: M* Energy* Energywww.camfil.comG7 C35+ 287 592 600 F7 1700 110 4 3 0, 035 1,50 CFG7 63 C35+ 592 287 600 F7 1700 110 8 3 0, 035 1,50 CFG7 65 C35+ 592 490 600 F7 2800 110 8 4,5 0,050 2,40 CHG7 33 C35+ 287 287 600 F7 800 110 4 1,5 0,020 0,80 CFG7/520 C35+ 592 592 520 F7 3400 120 8 5,2 0,050 2,60 71 35 C 1 482 GG7/520 C35+ 490 592 520 F7 2800 120 6 3,9 0,050 2,40 CHG7/520 C35+ 287 592 520 F7 1700 120 4 2,5 0, 035 1,50 CFG7 63/20 C35+ 592 287 520 F7 1700 120 8 2,5 0, 035 1,50 CFG7 65/20 C35+ 592 490 520 F7 2800 120 8 3,7 0,050 2,40 CHG7 33/20 C35+ 287 287 520 F7 800 120 4 1,3 0,020 0,80 CFG7/370 D35+ 592 592 370 F7 3400 150 8 3,6 0,050 2,40 70 35 D 1 920 GG7/370 D35+ 490 592 370 F7 2800 150 6 2,7 0,050 2,10 DHG7/370 D35+ 287 592 370 F7 1700 150 4 1,8 0, 035 1,50 DFG7 63/70 D35+ 592 287 370 F7 1700 150 8 1,8 0, 035 1,50 DFG7 65/70 D35+ 592 490 370 F7 2800 150 8 2,7 0,050 2,10 DHG7 33/70 D35+ 287 287 370 F7 800 150 4 0,9 0,020 0,80 Dinimum efficiency ref. to EN779:2012 Consumption, kWh/year: Calculated according to Eurovent Guideline 4/11 class: Calculated according to Eurovent 4/11
Most popular related searches