Coastal Controls & Instrumentation Inc. (CCII)
- Home
- Companies & Suppliers
- Coastal Controls & Instrumentation Inc. ...
- Downloads
- Beta Calibrators - PTC-8010 - ...
Beta Calibrators - PTC-8010 - Multifunction Temperature Calibrator Brochure
Calibration Technology Starts HereWork better and get better work with Martel TEN seriesmultifunction calibrators. This family of 5 models scale up to doany size job you need when calibrating process instrumentation.Start at the top with the DMC-1410 documenting multifunctioncalibrator. It’s versatile, providing access to a complete range ofcalibration functions while performing automated on the fly calibration data collectionand storage. A simple easy-to-use software package is included that allows the user tobuild a database of all assets that need calibration and download work orders to thecalibrator.Next in line is the MC-1210 multifunction calibrator. It’s a rugged and reliable universalcalibrator. Like all the others in this series, the MC-1210 is based on the proven reliable, accurate andstable MC-1200. It’s dual display and isolated readback allows it to power a transmitter under test whilereading its milliamp output. Truly an all-in-one calibrator. The MC-1210 also has a wide range ofswitch test features for both pressure and temperature switches.The MC-1010 provides a high level of functions and features at an easy to swallow price forthe less demanding user who does not require the isolated read-back feature found on theDMC-1410 or MC-1210.For those who need specialty temperature calibration with high accuracy, the PTC-8010 is thechoice. Special display features show the cold junction temperature and milliVolt equivalents at aglance for thermocouples. Ohms equivalents are shown when using the RTD functions.The PSC-4010 is a superior loop calibrator with voltage, current and frequency functions. With the bestdisplay in the business it makes the essentials of instrument calibration easier than ever. And, abonus feature not found in other loop calibrators is frequency in and out.This innovative series features the introduction of a new, high contrastClearBrite™ graphic display. The display features a vivid white backlight thatmakes the display easy to read in all light conditions.All of these models have Martel’s easy to learn yet powerful 3 key menustructure. It’s the same menu used in all of the company’s BetaGauge pressurecalibrators, too. Learn it once and you’ll know how to use every significantcalibrator Martel makes.General Features. New ClearBrite™ Graphic Display. Auto Stepping/Auto Ramping. 3 Key Martel Menu System. Scroll/Step Output Control. NIST Calibration Certificate. Proven Rugged Reliable Design. Fuseless Protection to 250 VACFor more information:- Call us toll free at 800-821-0023or 603-434-1433- Fax us at 603-434-1653- Email us at sales@martelcorp.comand ask for the “10” Series Calibrators- Or go to our website,www.martelcalibrators.comand click on Multifunction CalibratorsPrecision Calibrators “10” Series CalibratorsMartel “10” Series Calibrators†with optional BPPA-100 pressure module adapter10 Series Function Table10 Series Feature TableDMC 1410 MC 1210 MC 1010 PTC 8010 PSC 4010General Specifications (applies to all models)Operating Temperature -10 to 50°CStorage Temperature -20 to 70°CPower (4) AAAlkaline or optional rechargeable batteriesLow Battery Warning Yes, on displayClearBrite™ Display High contrast 128 x 64 pixel addressable graphicLCD w/daylight backlight2.4 x 1.8 in. • 63 x 44 mmSerial Communications Yes, ASCII, RS-232, requires optional Martel1919069 serial cable or 1919896 USB cableCE – EMC EN50082-1 and EN55022: 1994 Class BSafety CSA C22.2 No. 1010-1: 1992Weight (with batteries) 1.8 lb (0.82 kg)Size 8.5 x 4.8 x 2.1 in. (22 x 12 x 5.3 cm)Other IP54Protected against misconnection to 250 VAC/VDCFunctionModelDMC-1400 . . . . . . . . . .MC-1210 . . . . . . . . .MC-1010 . . . . . . .PTC-8010 . .PSC-4010 . . . .DocumentingDualDisplayIsolatedReadbackCurrent In/OutVoltagein/OutLoopPowerThermocoupleIn/OutRTD/??In/OutFrequencyPressure+FrequencyModel Measurement Source Measurement Source Measurement SourceDMC-1410 Range 2.0 CPM - 600.0 CPM 2.0 CPM - 600.0 CPM 1.0 Hz - 1000.0 Hz 1.0 Hz - 1000.0 Hz 1.00 kHz - 10.00 kHz 1.00 kHz - 10.00 kHzAccuracy 0.05% ± 0.1 CPM 0.05% 0.05% ± 0.1 Hz 0.05% 0.05% ± 0.01 kHz 0.125%MC-1210 Range 2.0 CPM - 600.0 CPM 2.0 CPM - 600.0 CPM 1.0 Hz - 1000.0 Hz 1.0 Hz - 1000.0 Hz 1.00 kHz - 10.00 kHz 1.00 kHz - 10.00 kHzAccuracy 0.05% ± 0.1 CPM 0.05% 0.05% ± 0.1 Hz 0.05% 0.05% ± 0.01 kHz 0.125%MC-1010 Range 2.0 CPM - 600.0 CPM 2.0 CPM - 600.0 CPM 1.0 Hz - 1000.0 Hz 1.0 Hz - 1000.0 Hz 1.00 kHz - 10.00 kHz 1.00 kHz - 10.00 kHzAccuracy 0.05% ± 0.1 CPM 0.05% 0.05% ± 0.1 Hz 0.05% 0.05% ± 0.01 kHz 0.125%PSC-4010 Range 2.0 CPM - 600.0 CPM 2.0 CPM - 600.0 CPM 1.0 Hz - 1000.0 Hz 1.0 Hz - 1000.0 Hz 1.00 kHz - 10.00 kHz 1.00 kHz - 10.00 kHzAccuracy 0.05% ± 0.1 CPM 0.05% 0.05% ± 0.1 Hz 0.05% 0.05% ± 0.01 kHz 0.125%Resistance Measurement (Autoranging)Model Ohms Low Ohms HighDMC-1410 Range 0.00? - 400.00 401.0? - 4000.0Accuracy 0.015% ± 0.03 0.015% ± 0.3MC-1210 Range 0.00? - 400.00 401.0? - 4000.0Accuracy 0.025% ± 0.05 0.025% ± 0.5MC-1010 Range 0.00? - 400.00 401.0? - 4000.0Accuracy 0.025% ± 0.05 0.025% ± 0.5PTC-8010 Range 0.00? - 400.00 401.0? - 4000.0Accuracy 0.025% ± 0.05 0.025% ± 0.5DCVoltage and CurrentModel Measurement Measurement Source Measurement Measurement SourceDMC-1410 Range 0.000V - 30.000V 0.000V - 20.000V 0.000V - 20.000V 0.000mA - 24.000mA 0.000mA - 24.000mA 0.000mA - 24.000mAAccuracy 0.01% ± 2 mV 0.01% ± 2 mV 0.01% ± 2 mV 0.01% ± 2µA 0.01% ± 2µA 0.01% ± 2µAMC-1210 Range 0.000V - 30.000V 0.000V - 20.000V 0.000V - 20.000V 0.000mA - 24.000mA 0.000mA - 24.000mA 0.000mA - 24.000mAAccuracy 0.015% ± 2 mV 0.015% ± 2 mV 0.015% ± 2 mV 0.015% ± 2µA 0.015% ± 2µA 0.015% ± 2µAMC-1010 Range N.A. 0.000V - 20.000V 0.000V - 20.000V N.A. 0.000mA - 24.000mA 0.000mA - 24.000mAAccuracy N.A. 0.015% ± 2 mV 0.015% ± 2 mV N.A. 0.015% ± 2µA 0.015% ± 2µAPSC-4010 Range N.A. 0.000V - 20.000V 0.000V - 20.000V N.A. 0.000mA - 24.000mA 0.000mA - 24.000mAAccuracy N.A. 0.015% ± 2 mV 0.015% ± 2 mV N.A. 0.015% ± 2µA 0.015% ± 2µADCVoltageUpper IsolatedDCVoltageLower Non-IsolatedDC CurrentUpper IsolatedDC CurrentLower Non-IsolatedNote: optional 50 mA range availablePSC-4010 MilliVolts Measurement/SourceFunction Range AccuracyRead 0000 mV – 90.000 mV 0.02% ± 10 µVSource 0.000 mV – 100.000 mV 0.02% ± 10 µVResistance Source (Autoranging)Ohms Source Low Ohms Source High Ohms Source HighModel Range Excitation Current Accuracy Range Excitation Current Accuracy Range Excitation Current AccuracyDMC-1410 5.0? - 400.0 0.1 – 0.5 mA 0.015% ± 0.1 401? - 1500 0.05 – 0.8 mA 0.015% ± 0.3 1500? - 4000 0.05 – 0.4 mA 0.015% ± 0.35.0? - 400.0 0.5 - 3 mA 0.015% ± 0.03MC-1210 5.0? - 400.0 0.1 – 0.5 mA 0.025% ± 0.1 401? - 1500 0.05 – 0.8 mA 0.025% ± 0.5 1500? - 4000 0.05 – 0.4 mA 0.025% ± 0.55.0? - 400.0 0.5 - 3 mA 0.025% ± 0.05MC-1010 5.0? - 400. 0.1 – 0.5 mA 0.025% ± 0.1 401? - 1500 0.05 – 0.8 mA 0.025% ± 0.5 1500? - 4000 0.05 – 0.4 mA 0.025% ± 0.55.0? - 400.0 0.5 - 3 mA 0.025% ± 0.05PTC-8010 5.0? - 400.0 0.1 – 0.5 mA 0.025% ± 0.1 401? - 1500 0.05 – 0.8 mA 0.025% ± 0.5 1500? - 4000 0.05 – 0.4 mA 0.025% ± 0.55.0? - 400.0 0.5 - 3 mA 0.025% ± 0.05RTD Measurement/Source(DMC-1410, MC-1210, MC-1010 andPTC-8010 only)TC Type Range (°C) Accuracy (°C)With CJC OFF With CJC ONJ -210.0 – 0.0 0.4 0.60.0 – 800.0 0.2 0.4800.0 – 1200.0 0.3 0.5K -200.0 – 0.0 0.6 0.80.0 – 1000.0 0.3 0.51000.0 – 1372.0 0.5 0.7T -250.0 – 0.0 0.6 0.80.0 – 400.0 0.2 0.4E -250.0 – -100.0 0.6 0.8-100.0 – 1000.0 0.2 0.4R 0.0 – 1767.0 1.2 1.4S 0.0 – 1767.0 1.2 1.4B 600.0 – 800.0 1.2 1.0800.0 – 1000.0 1.3 1.51000.0 – 1820.0 1.5 1.7C 0.0 – 1000.0 0.6 0.81000.0 – 2316.0 2.3 2.5XK -200.0 – 800.0 0.2 0.4BP 0.0 – 800.0 0.9 1.1800.0 – 2500.0 2.3 2.5L -200.0 – 0.0 0.3 0.50.0 – 900.0 0.2 0.4U -200.0 – 0.0 0.5 0.70.0 – 600.0 0.3 0.5N -200.0 – 0.0 0.8 1.00.0 – 1300.0 0.4 0.6NotesAll specifications apply at 23°C ± 5°C unless otherwise stated. Outside ofthis range add ±0.005% of reading/°C.Accuracy is % of reading ± floor spec.Maximum current output in voltage ranges is 1 mA with an outputimpedance of = 1 .Maximum load on mA source is 1000 . Voltage input range onsimulate mode 5 – 30 V.Frequency input voltage amplitude range is 1V to 20V zero basedsquare wave only. Output amplitude is adjustable from 1V to 20V,and is a square wave with 50% duty cycle. For output frequency,a negative offset of approximately -0.1V is present to assurezero crossing.In Ohms source and RTD source modes, units arecompatible with smart transmitters and PLCs that use astrobing excitation current. Frequency response is 5 msec.mV/Thermocouples (DMC-1410,MC-1210, MC-1010 and PTC-8010 only)DMC-1410 MC-1210,MC-1010,PTC-8010MilliVolts (mV) Range Accuracy AccuracyRead -10.000 mV – 75.000 mV 0.015% ± 10 µV 0.02% ± 10 µVSource -10.000 mV – 75.000 mV 0.015% ± 10 µV 0.02% ± 10 µVMaximum current output in voltage ranges is 1 mA with an outputimpedance of == 1 DMC-1410 MC-1210, MC-1010,PTC-8010RTD Type Range (°C) Accuracy (°C) Accuracy (°C)PT385, 10 -200.0 – -80.0 0.76 1.3-80.0 – 0.0 0.78 1.30.0 – 100.0 0.83 1.4100.0 – 300.0 0.92 1.5300.0 – 400.0 0.98 1.6400.0 – 630.0 1.05 1.8630.0 – 800.0 1.16 1.9PT385, 50 -200.0 – -80.0 0.16 0.3-80.0 – 0.0 0.23 0.40.0 – 100.0 0.23 0.4100.0 – 300.0 0.23 0.4300.0 – 400.0 0.27 0.5400.0 – 630.0 0.30 0.5630.0 – 800.0 0.36 0.6PT385, 100 -200.0 – -80.0 0.08 0.1-80.0 – 0.0 0.13 0.20.0 – 100.0 0.14 0.2100.0 – 300.0 0.15 0.2300.0 – 400.0 0.18 0.3400.0 – 630.0 0.21 0.3630.0 – 800.0 0.26 0.4PT3926, 100 -200.0 – -80.0 0.07 0.1-80.0 – 0.0 0.10 0.20.0 – 100.0 0.11 0.2100.0 – 300.0 0.13 0.2300.0 – 400.0 0.17 0.3400.0 – 630.0 0.19 0.3PT3916, 100 -200.0 – -80.0 0.07 0.1-80.0 – 0.0 0.10 0.20.0 – 100.0 0.11 0.2100.0 – 260.0 0.13 0.2260.0 – 300.0 0.17 0.3300.0 – 400.0 0.17 0.3400.0 – 630.0 0.19 0.3PT385, 200 -200.0 – -80.0 0.35 0.6-80.0 – 0.0 0.40 0.70.0 – 100.0 0.42 0.7100.0 – 260.0 0.45 0.7260.0 – 300.0 0.45 0.7300.0 – 400.0 0.52 0.9400.0 – 630.0 0.53 0.9PT385, 500 -200.0 – -80.0 0.15 0.2-80.0 – 0.0 0.18 0.30.0 – 100.0 0.19 0.3100.0 – 260.0 0.21 0.4260.0 – 300.0 0.25 0.4300.0 – 400.0 0.26 0.4400.0 – 630.0 0.29 0.5PT385, 1000 -200.0 – -80.0 0.10 0.2-80.0 – 0.0 0.12 0.20.0 – 100.0 0.14 0.2100.0 – 260.0 0.14 0.2260.0 – 300.0 0.17 0.3300.0 – 400.0 0.19 0.3400.0 – 630.0 0.22 0.4NI120 -80.0 – 260.0 0.6 0.1Cu10 -100.0 – 260.0 0.77 1.3Cu50 -180.0 – 200.0 0.16 0.3Cu100 -180.0 – 200.0 0.08 0.1YSI400 15.0 – 50.0 0.05 0.1Accuracy statements are based on 4W connectionsMartel Electronics offers 27 standard pressuremodules, covering gauge, vacuum, absolute,compound, and differential measurements. Allmodules are directly compatible with the Beta-Gauge II. With the Model BPPA-100 PressureModule Adapter, all modules (with the exception ofthe DC measurement model) are fully compatiblewith the Martel MC-1210 and MC-1010 Multi-Function Calibrators, the BetaGauge 330, 321A,311A and 301 Pressure Calibrators, the DMC-1410Documenting Multi-Function Calibrator, and theMartel Electronics M2001 and 3001 Laboratory/BenchStandards.Pressure ranges may be displayed in any of 13 userselectable units. Water density correction factors of 4 °C,20 °C, or 60 °F can be selected for either water columnunit. The choice of pressure unit may be restricted bylimitations on resolution of the instrument display of theparticular calibrator the module is used with. For optimummechanical strength, external pressure connection is madeby a 1/8” FNPT 316SS connector welded to a stainless steelmetal plate.General Features.27 standard ranges.Gauge, vacuum, absolute, compound, anddifferential measurements.Accuracy specified over 15 °C to 35 °C range. Isolated and non-isolated measurements,range dependantModel BPPA-100Pressure Module AdapterBetaGaugePressure ModulesAVAILABLE MODULESPARAMETER/ FULLSCALE VACUUM OVERRANGE ACCURACY ACCURACY PRESSUREIsolated Gauge (PSIG):0 to15 (0 to 1 Bar) ±0.025 % 300 %0 to 30 (0 to 2 Bar) ±0.025 % 300 %0 to 500 (0 to 35 Bar) ±0.025 % 200 %0 to1000 (0 to70 Bar) ±0.025 % 200 %0 to1500 (0 to 100 Bar) ±0.035 % 200 %0 to3000 (0 to200 Bar) ±0.05 % 200 %0 to5000 (0 to340Bar) ±0.05 % 200 %0 to10000 (0 to 700 Bar) ±0.1 % 120 %Non Isolated Compound (PSIG):-0.4 to 0.4 (-20 to 20 mBar) ±0.1 % ±0.15 % 400 %-1 to 1 (-70 to 70 mBar) ±0.05 % ±0.1 % 400 %-5 to 5 (-350 to 350 mBar) ±0.075 % ±0.1 % 400 %-7.2 to 7.2 (-500 to 500 mBar) ±0.07 % ±0.1 % 300 %-10 to 10 (-700 to 700 mBar) ±0.03 % ±0.05 % 300 %-15 to 15 (-1 to 1 Bar) ±0.04 % ±0.04 % 300 %-15 to 30 (-1 to 2 Bar) ±0.025 % ±0.025 % 300 %Isolated Compound (PSIG):-12 to 50 (-0.8 to 3.5 Bar) ±0.03 % ±0.03 % 200 %-12 to 100 (-0.8 to 7 Bar) ±0.025 % ±0.025 % 200 %-12 to 150 (-0.8 to 10 Bar) ±0.03 % ±0.03 % 200 %-12 to 300 (-0.8 to 20 Bar) ±0.025 % ±0.025 % 150 %Isolated Absolute (PSIA):0 to 15 (0 to 1 Bar) ±0.04 % 300 %0 to 30 (0 to 2 Bar) ±0.025 % 300 %0 to 50 (0 to 3.5 Bar) ±0.03 % 300 %0 to 100 (0 to 7 Bar) ±0.025 % 300 %0 to 300 (0 to 20 Bar) ±0.025 % 200 %Differential (PSID):0 to 5 (0 to 350 mBar) ±0.075% 400 %0 to 30 (0 to 2 Bar) ±0.025% 300 %0 to 50 (0 to 3.5 Bar) ±0.03% 300 %BetaGauge Pressure ModulesMartel Electronics Corporation Distributed by:3 Corporate Park Drive, Unit 1Derry, NH 03038Phone: +1 (603) 434-1433Fax: +1 (603) 434-1653Copyright 2011 Martel Electronics;All trademarks are the property oftheir respective owners. 1101R1CD-XX10Specifications subject to change without notice.10 Series Multifunction Ordering InformationPart Number Description1920002 DMC-1410 Documenting Multifunction Calibrator1919907 DMC-1410PM Panel Mount Documenting Multifunction Calibrator1920001 MC-1210 Multifunction Calibrator1919906 MC-1210PM Panel Mount Multifunction Calibrator1919910 MC-1210-50 Multifunction Calibrator 50 mA range1919999 MC-1010 Multifunction Calibrator1919905 MC-1010PM Panel Mount Multifunction Calibrator1919909 MC-1010-50 Multifunction Calibrator 50 mA range1920000 PTC-8010 Multifunction Temperature CalibratorInquire PTC-8010PM Panel Mount Multifunction Temperature Calibrator1919895 PSC-4010 Multifunction Loop & Frequency CalibratorInquire PSC-4010PM Panel Mount Multifunction Loop & Frequency Calibrator1919908 PSC-4010-50 Multifunction Loop & Frequency Calibrator 50 mA rangeAll calibrators include• Calibrator as above• Deluxe soft sided carrying case• Test leads• User Manual• NIST Traceable Calibration Certificate• (4) AAAlkaline BatteriesNote: Panel mount option is available on all 50 mA range calibrators. Please inquire.
Most popular related searches
