Veris Industries

Carbon Dioxide Sensors-CWLSXX

AIR QUALITYVERIS INDUSTRIES800.354.8556 +1 503.598.4564 www.veris.comDESCRIPTIONCDL/CWL carbon dioxide sensors maximize energy savings, while ensuring optimal ventilation. These sensors allow ventilation systems to be controlled by the amount of CO2 present in a space. The CWL/CDL Series detect fluctuations in CO2 levels and signal ventilation systems to provide an inlet of fresh air optimal for the space at a given time saving energy and ensuring tenant comfort.APPLICATIONS? Controlling ventilation in response to occupancy? Facilitating compliance with ASHRAE 62.1 standard for air quality? Office buildings, conference rooms, schools, retail stores, etc.Individual or 3-in-1 CO2, RH, and TemperatureDeluxe Duct and Wall CO2 SensorsSPECIFICATIONSInput Power 20 to 30VDC/24VAC; 100mA max.Analog Output 4-20mA (clipped & capped)/0-5VDC/0-10VDC (selectable)Operating Temperature Range CDL: 0° to 50°C (32° to 122°F) CWL: No humidity option: 0° to 50°C (32° to 122°F); With humidity option: 10° to 35°C (50° to 95°F)Operating Humidity Range 0 to 95% RH noncondensingHousing Material High impact ABS plastic CO2 Transmitter: Sensor Type Non-dispersive infrared (NDIR), diffusion sampling Output Range 0-2000/5000 ppm (programmable) Accuracy ±30 ppm ±2% of measured value* Repeatability ±20 ppm ±1% of measured value Response Time <60 seconds for 90% step changeRH Transmitter: HS Sensor Fully replaceable, digitally profiled thin-film capacitive (32-bit mathematics) U.S. Patent 5,844,138 Accuracy ±2% from 10 to 80% RH @ 25°C; NIST traceable multi-point calibration Hysteresis 1.5% typical Stability ±1% @ 20°C (68°F) annually for two years Output Range 0-100% RH Temperature Coefficient ±0.1% RH/°C above or below 25°C (typical)Temperature Transmitter: Sensor Type Solid-state, integrated circuit Accuracy ±0.5°C (±1°F) typical Resolution 0.1°C (0.2°F) Output Range 10° to 35°C (50° to 95°F)Relay Contacts: 1 Form C (SPDT) (on models without setpoint slider option) 1A@30VDC, resistive; 30W max.RTD/Thermistors in wall packages are not compensated for internal heating of product.EMC Conformance: Low voltage directive 2006/95/EC and EMC directive 2004/108/EC.EMC Special Note: Connect this product to a DC distribution network or an AC/DC power adaptor with proper surge protection (EN 61000-6-1:2007 specification requirements).Note: Rough handling and transportation may cause a temporary reduction of CO2 sensor accuracy. With time, the ABC function will tune the readings back to the correct accuracy range. The default tuning speed is limited to 30 ppm per week.FEATURES ? Microprocessor-based design increases accuracy and reduces installation time? Non-dispersive infrared technology (NDIR) repeatable to ±20 ppm ±1% of measured value...high accuracy measurement? Innovative self-calibration algorithm...easy to maintain? 5-year calibration interval (recommended)? Field-selectable outputs for operation flexibility? Integrated transducer and probe...eliminates the need to install a separate pick-up tube? Snap-on faceplate...no screws required, making installation and service easy? Adjustable duct probe...simplifies installation and airflow monitoring? CO2, humidity, and temperature sensing all in one compact device...fewer units to buy and installC SERIESCDLCWLHQ0001739.B 01131AIR QUALITY800.354.8556 +1 503.598.4564 www.veris.comPower (+24)CO2 OUTCOMMONOptional *RH OUTT OUTRELAYN.C.RELAY N.O.RELAY COMPower (+24)CO2 OUTCOMMONRH OUTOptional *RTD/THERMISTOR/OVERRIDE OUTRTD/THERMISTOR/OVERRIDE OUTSLIDER RIGHTSLIDER WIPERSLIDER LEFTPower (+24)CO2 OUTCOMMONRH OUTOptional *RTD/THERMISTOR/OVERRIDE OUTRTD/THERMISTOR/OVERRIDE OUTRELAY N.O.RELAY COMRELAY N.C.APPLICATION/WIRING DIAGRAMSCDL: Temp and/or RH OptionsDIMENSIONAL DRAWINGSACCESSORIESCalibration kits and gases (AA01, AA26, AA27, AA28, AA29)Handheld air quality testers (1010, 1008, 770)Replacement covers and housing for wall units (AA52, AA52B, AA55)CWL: CO2, RH, Thermistor, Pushbutton Override, and Setpoint Slider OptionsCDL: CO2 onlyTemp. Sensor TypeSensor TypeA = TransmitterB = 100R Platinum, RTD C = 1k Platinum, RTDD = 10k T2, ThermistorE = 2.2k, ThermistorF = 3k, ThermistorG = 10k CPC, ThermistorH = 10k T3, ThermistorJ = 10k Dale, ThermistorK = 10k w/11k shunt, ThermistorM = 20k NTC, ThermistorN = 1800 ohm, ThermistorR = 10k US, ThermistorS = 10k 3A221, ThermistorT = 100k, ThermistorU = 20k “D”, ThermistorW = 10k T2 high accuracy, ThermistorY = 10k T3 high accuracy, ThermistorZ = 10k E1, ThermistorT = TempX = No(stop here)H = RH 2%X = No RHCWLSTemp Cal Cert Option Setpoint Slider Value1 = Push Button Override *2 = Set Point Slider3 = Push Button Override*+Set Point SliderA = 1kF = 10kG = 20kK = 50kM =100kAvailable Options-H = RH2%X = No RHCDLSTempT = Temp X = No Temp(Stop here)A = TransmitterB = 100R Platinum, RTD C = 1k Platinum, RTDD = 10k T2, ThermistorE = 2.2k, ThermistorF = 3k, ThermistorG = 10k CPC, ThermistorH = 10k T3, ThermistorJ = 10k Dale, ThermistorK = 10k w/11k shunt, ThermistorM = 20k NTC, ThermistorN = 1800 ohm, ThermistorR = 10k US, ThermistorS = 10k 3A221, ThermistorT = 100k, ThermistorU = 20k “D”, ThermistorW = 10k T2 high accuracy, ThermistorY = 10k T3 high accuracy, ThermistorZ = 10k E1, ThermistorOptional Cal CertExample:CDLS H T B 2OptionsExample:CWLS H T C 2 2 ACWL Wall Mount CDL Duct MountDuct Mount Wall MountRH Option RH OptionX = No1 = 1pt Temp Cert2 = 2pt Temp CertBlank = None1 = 1 pt Temp Cert2 = 2 pt Temp Cert* The Push Button Override feature is not available with temperature transmitter models. Only resistive temperature models qualify for this featureCWL: CO2, RH, Temperature Transmitter Options* Note: Connector blocks and headers for optional features are not included with non-option models.CWL: CO2, RH, Thermistor, Pushbutton Override, and Relay OptionsORDERING INFORMATIONmA VoltNC COMM NOPLUS1/2” NPT MALE CONDUIT ADAPTER1/2” NPT FEMALE COUPLER ENTERMINUSCONFIGURATIONPUSHBUTTONSV+ CO2-OUT GND ONOFFLOWABC RTDRH OUTGNDCO2 OUTV+ TEMP OUT/RTDmAVoltPLUSENTERMINUSCONFIGURATIONPUSHBUTTONSNC COMM NO4.8"(122 mm)1.2"(30 mm)3.5"(89 mm)6.7"(170 mm)3.1"(78 mm)7.8"(97 mm)2.4"(61 mm)10.2"(258 mm)Power (+24)CO2 OUTCOMMONOptional *SLIDER RIGHTSLIDER WIPERSLIDER LEFTRH OUTT OUTCWL: CO2, RH, Temperature Transmitter, and Setpoint Slider OptionsBlank = Cloud whiteB = BlackHousingHQ0001739.B 01131
Most popular related searches