LabLogic Systems Limited
Chameleon
The Most Versatile Multilabel Microplate ReaderThe latest technologyin multilabel detection instrumentsChameleon V has a compact design which includes up to 6 differentmeasurement modes to provide a powerful and flexible platform forperforming assays using:Using three different detectors on a unique and patented optical design, Chameleon V achievesoptimal performance for filter-based assays, such as absorbance and fluorescence, as well asultra-high sensitivity single-photon detection for luminescence and liquid scintillation counting.Chameleon V uses programmed filter slides for both fluorescence and absorbance that allow fastand easy filter exchange by the user. Up to 20 different excitation and 20 different emission filterscan be stored for easy access to multiple assays. As an option,Chameleon V can accommodateup to 2 automated injectors within its compact design. Chameleon V offers the greatest flexibility to researchers by providing access to any number ofdifferent assays. Choose from several configurations and options to suit your specific requirements.Liquid Scintillation Counting (LSC)Luminescence (LUM)Fluorescence Intensity (FI)Time-Resolved Fluorescence (TRF)Fluorescence Polarization (FP)Absorbance (ABS)MikroWin is a comprehensive software package for control of the Chameleon V and for dataevaluation of all assays. The software controls instrument parameters such as measurementtechnology and mode (endpoint or kinetic), type of plate, selection of wells to be measured,filter selection, activation of temperature control, shaking options, injectors, etc. All of theseparameters can be saved as a unique method.Measurement data is automatically saved and linked to the method file, which also includespreset calculations for data analysis. The calculated data can be easily saved, printed orexported. The overlay and layout of the microplate is also part of the method file, which isshown graphically and can be easily adjusted. Test controls (standards and concentrations)may be assigned in any well position and each individual control or standard is color-coded.In addition MikroWin software offers several curve fitting routines, qualitative distributionusing thresholds, kinetic graphics and calculations, and several other advanced data analysisand report generation features. MikroWin SoftwareChameleon V as a Liquid Scintillation Counter (LSC)An easy-to-use microplate scintillation counter with a unique instant DPM quenchcorrection function and preset modes for the most commonly used radioisotopes(3H, 14C, 35S, 33P, 32P, 125I). Other nuclides are easy to program.• Scintillation Proximity Assay™ (SPA) • Radioimmunoassays (RIA)• FlashPlate™ Assays • Cell Proliferation• Immunoradiometric Assays (IRMA) • Wipe Tests• Binding Studies • Filter-based AssaysChameleon V as a photon-counting Luminometer (LUM)Ultra-high luminescence sensitivity down to less than 1amol ATP/welland a detection range exceeding six decades, combined with automaticinjectors and temperature control opens up new possibilities.• ATP Detection • Toxicology Applications• Reporter Gene Assays • Dual Luciferase Assays• Luminescence Immunoassays • BRETChameleon V as a Fluorescence Intensity reader (FI)An ideal reader for end-point or kinetic measurements of short decay-timefluorophores. Multiple wavelength modes with emission range up to 850nm.• Cytotoxicity • Binding Studies• Immunoassays • Enzyme Activity• FRET • Ligand Receptor Binding AssaysChameleon V as a Time-Resolved Fluorescence reader (TRF)Measurement of long-decay time lanthanide chelate fluorophoreslike Eu, Tb and Sm.• DELFIA™• TR-FRETChameleon V as a Fluorescence Polarization reader (FP)Sensitive and homogeneous analysis of molecule-molecule interactions can beperformed by measuring the rotational properties of molecules. This is possibleusing dual emission detection with dedicated FP filter slide sets.• Protein-Protein Binding • Estrogen Receptor AssayChameleon V as an Absorbance reader (ABS)An easy-to-use filter-based absorbance photometer with a wavelength range from230 to 900nm. For end-point, kinetic and multiple wavelength measurements.• DNA/RNA Quantitation • DNA Purity (260/280 nm)• PCR Quantitation • Enzyme Assays• Immunoassays (ELISA) • Protein QuantificationTypical ApplicationsAdditional services to backup your product investment…Service & SupportUsers of our instrumentation can benefit from our comprehensive, fully inclusive instrumentservice and support.We provide complete service and support for all of our customers to give reassurancethat if things go wrong, help is only an e-mail or phone call away.Service.Support.Reassurance.Validation ServicesWe believe that nobody knows and understands our systems and the needs of the research anddevelopment laboratory better than we do, which is why we have put together Validation Servicesto enable you to implement and get maximum value from your investment as quickly as possible.We work as a partner with your System Manager and users to provide a tailored Validation Plansuited to your needs. Our Validation Specialists incorporate years of experience in GLPsystem validation, detailed knowledge of our systems, together with other industry standardsystems to help you meet your Company's requirements.Design by bluestrawberryelephant.co.uk ©2010.USA & CanadaLabLogic Systems, Inc.East Pointe Park,1040 East Brandon Blvd.Brandon, FL 33511-5509E-mail: sales@lablogic.comTel: +1-813-626-6848Tel: +1-800-875-INUS (4687)Fax: 813-620-3708EuropeLabLogic Systems Limited,Paradigm House, 3 Melbourne Avenue,Broomhill, Sheffield, England,S10 2QJ, U.K.E-mail: solutions@lablogic.comTel: +44 (0) 114 266 7267Fax: +44 (0) 114 266 3944For other instruments in our range please visit our website: www.lablogic.comwww.lablogic.com cam2.pdf cam3.pdf cam4.pdf cam1.pdf
Most popular related searches
