Global Treat, Inc
- Home
- Companies & Suppliers
- Global Treat, Inc
- Downloads
- Chlorine and Sulfur Dioxide Systems 300 ...
Chlorine and Sulfur Dioxide Systems 300 Series- Brochure
INSTRUMENTS 600 Emlen Way, Telford, PA 18969 • Telephone: (215) 799-0980 • Fax: (215) 799-0984BULLETIN 300 Rev. 2/12 Toll Free in the U.S.: 1 (888) 38-HYDRO • www.hydroinstruments.com • sales@hydroinstruments.comPROUDLYMADE IN USACorrosion ResistantHastelloy-CYoke AdapterYoke Bolt fitstwisted cylinder wrench• 3-Year Limited Warranty• Hastelloy-C Inlet Adapters• Solid Machined PVC ConstructedHydro Instruments has been manufacturing the highest quality gas chlorination and sulfonation equipment since 1978. Now Hydro Instruments also offers this popular and proven design as a reliable and economical alternative. The Series 300 offers feed rates up to 500 PPD (10 kg/hr). Systems are available with automatic switchover capabilities and the vacuum regulators can be outfitted with an optional out of gas alarm switch.QualityHydro Instruments continually strives to produce the longest lasting and most reliable gas chlorination and sulfonation equipment on the market. We believe that this means using only the highest quality materials and most rugged designs. To avoid cracking, our body parts are machined from solid PVC and designed with heavy wall thickness. For maximum durability and corrosion resistance our inlet adapters are constructed of Hastelloy-C and our yoke assemblies are protected by the finest Epoxy Powder Coating.SafetyFor Hydro, safety is the highest concern. Here are two points that set us apart from the competition: 1. Our rugged design and highest quality machined parts maximize safety by avoiding cracks and corrosion. 2. At Hydro Instruments a skilled technician follows a rigorous testing procedure for each and every vacuum regulator.ConvenienceDesign: Hydro has designed the vacuum regulator yokes so that a twisted cylinder wrench can be used for both the cylinder and vacuum regulator. One of these wrenches is provided with each vacuum regulator purchased from Hydro. (See photo at right.)Repairs: Hydro equipment is designed with fewer parts and our assemblies are designed to be easily repaired without special tools.Service: We provide our top quality parts at reasonable prices and always keep all parts in stock. Also, expedited service is the norm with Hydro; most orders ship the same day and we never charge expediting fees.Series 300Chlorine andSulfur Dioxide Systems INSTRUMENTS 600 Emlen Way, Telford, PA 18969 • Telephone: (215) 799-0980 • Fax: (215) 799-0984BULLETIN 300 Rev. 2/12 Toll Free in the U.S.: 1 (888) 38-HYDRO • www.hydroinstruments.com • sales@hydroinstruments.comPROUDLYMADE IN USATechnical DataModel Information CodeModel 3 ? ? ?? Gas C - Chlorine S - Sulfur Dioxide A - Ammonia Vacuum Regulator Mounting 1 - Cylinder or manifold mounted with rate valve 2 - Ton container mounted with rate valve 3 - Cylinder or manifold mounted with remote meter(s) and rate valve 4 - Ton mounted with remote meter(s) and rate valve 5 - Cylinder or manifold mounted with automatic switchover 6 - Ton mounted with automatic switchover Available Gas Flowmeters 3 - 4 ppd (75 g/h) 4 - 10 ppd (200 g/h) 5 - 25 ppd (0.5 kg/h) 6 - 50 ppd (0.9 kg/h) 7 - 100 ppd (2.0 kg/h) 8 - 250 ppd (5.0 kg/h) 9 - 500 ppd (10 kg/h)Accuracy: within 4% of maximum flowmeter capacityOperating Range: 20:1 manual; 10:1 automaticOperating Temperature: Ejector, 35°F to 120°F;Other components, -20°F to 120°FThe system operating temperature is largely dependent on the withdrawal rate of gas from the cylinder and is a func-tion of the existing ambient temperature.Represented byVacuum Tubing CONNECTIONS Model Maximum Capacity Vacuum Vent 37X 100 ppd (2 kg/h) 3/8" 3/8" 38X 250 ppd (5 kg/h) 1/2" 3/8" 39X 500 ppd (10 kg/h) 5/8" 3/8"Size Requirements – DistanceThe Hydro Series 300 Gas Feeder can be a few feet to several hundred feet from the ejector, depending on maximum feed rate and the diameter of connecting pipe or tubing. Maximum Feed Rate Length of Vacuum Tubing PPD (kg/h) 100' (31m) 200' (61m) 500' (153m) 50 (1) 3/8" 3/8" 1/2" 100 (2) 3/8" 1/2" 1/2" 250 (5) 1/2" 5/8" 3/4" 500 (10) 5/8" 3/4" 1"Note: Ammonia feed rates are 12, 25, 50, 100, and 250.Ejector Connections Capacity Standard 100 ppd Nozzle 1" hose and 3/4" NPT Diffuser 1" hose and 3/4" NPT 250 & 500 ppd Inlet 11/4" NPT Optional Outlet 11/4" NPT 11/2" hoseMaterials of ConstructionPVC, polyethylene, tantalum, silver, Hastelloy-C, monel, viton and teflon.Maximum back pressure at point of application for a standard ejector is 140 psig. For pressures greater than 140 psig, consult factory.All feed rate capacities shown in this bulletin are for chlorine. For sulfur dioxide, multiply each chlorine value by 0.95.Gas WarningAll unattended gas containers and gas feed equipment should be monitored for leaks. Gas sensitive detectors, which will respond quickly to gas leaks in the atmosphere, should be installed at each site.Options and AccessoriesInlet Water Assembly Isolating ValvesBooster Pumps Flexible ConnectorsScales Gas MasksManifolds Gas DetectorsAutomatic Controls
Most popular related searches
