COSA Xentaur - a brand by Process Insights, Inc.
COSA - CV Pro - Portable Calorific Value Measurement Brochure
RKI.D.BR.0001_A CV PRO Portable Calorific Value Measurement BTU/cf ? kcal/m3 ? MJ/m3 CV PRO™ Features: è 15 Second Response Time è 20 Hour Battery Life è Small & Light Weight è Calibrates In Normal Air Natural Gas Applications: þ Gas Turbine Fuel Gas Optimizing þ Gas Boiler Tuning þ Appliance Performance þ Natural Gas Well Spot Check þ City Gas Spot Check ™ 2RKI.D.BR.0001_A Methodology The Reflection ratio of gas mixture is determined by the kinds of composing gases as well as the mixture ratio. As long as the kinds of composing gases are known, the mixture ratio (concentration) can be determined by measuring the reflection ratio. The optic interferometer applied in the CV Pro™ displays “Interference Stripes” on the CCD. The Interference Stripes move proportional to the reflection ratio. The amount of the movement is measured by the solution of the interference stripes on CCD with Fourier analysis, and the result is converted to the reflection ratio. Concentration can be displayed by adding data like “measuring gas” and “base gas” to the reflection ratio determined by high accuracy. Sensitivity of the optic interferometer depends on the length of the chamber. Since the length of the chamber is physically unchanged by elapsing time, the high accuracy is maintained. 3RKI.D.BR.0001_A Overview of Operation Sample System In The Portable Case Easy access to operate with the sample system already in the case. One Button Calibration Easy to read LCD Logging & Graphing Features 4RKI.D.BR.0001_A SPECIFICATIONS COSA Xentaur Corporate Headquarters 84G Horseblock Road Yaphank, NY 11980 USA Phone: +1-631-345-3434 Website: www.CosaXentaur.com Model CV PRO™ Detection principle Interferometry Measuring gas Natural Gas or NG + LPG *See Note Measurement range 25-55 MJ/Nm3 (670-1475 BTU/cf) 0-1V external output 40-50 MJ/Nm3 (1073-1341 BTU/cf) Accuracy ±0.1 MJ/Nm3 (2.7 BTU/cf) *See Note Repeatability ±0.03 MJ/Nm3 10°C @ 1Atmosphere (0.8 BTU/cf) Response time =15 sec Time to 90% response Drifting 0.22 MJ/Nm3 10°C @ 1Atmosphere (5.9 BTU/cf) Sample flow rate ~0.2L/min Sample pressure Atmospheric pressure to +15 kPa Ambient temperature -10 to +40°C, 95%RH (non-condensing) Power source C size alkaline battery x 4 or AC adaptor Battery life Approximately 20 hours (continuous power on) Internal Data Logging 100 measurements logged showing date/time/Calorific Value PC external output Recorder output (RS-232C) by use of exclusive cable (optional) Dimensions & weight 340(W) x 235(H) x 180(D) mm, approximately 5.5kg *NOTE: Error per 1% vol. Gas Error (bias) O2 +0.237 MJ N2 +0.262 MJ CO +0.172 MJ CO2 +0.405 MJ C2H4 +0.0263 MJ C3H6 +0.0601 MJ Distributed by: Calibration gas of like composition to the stream gas being measured can be used to calibrate the CV PRO™ to reduce measurement bias when the stream gas composition contains appreciable amount of one or more of the constituents noted in the error by percent table. Typically the factory calibration of the CV PRO™ will be calibrated to meet the ±0.1 MJ/Nm3 (2.7 BTU/cf) accuracy statement.
Most popular related searches
