LOT-QuantumDesign
  1. Companies & Suppliers
  2. LOT-QuantumDesign
  3. Downloads
  4. Cryo-SEM Preparation Systems PP3010T- ...

Cryo-SEM Preparation Systems PP3010T- Brochure

PP3010TCryo preparation system for SEM, FE-SEM and FIB/SEMQuorum Technologies• Recipe driven touch-screen interface• Fully automated processes and start up• Gas cooled aQuilo preparation chamber• Superb specimen visibility • Cooling to -190ºC or better with rapid thermal response• Off column cooling and pumping – minimum mass on the SEM• Up to 24 hour hold times – no more topping up of dewars• Single port interface available (if microscope geometry allows)LOT-QuantumDesign Europe. For your local contact click at: www.lot-qd.comE-Mail: info@lot-qd.comPrepdekTM workstation The Prepdek™ is an ergonomically designed preparation and control centre. The Prepdek™ includes the freezing and pre-frozen specimen manipulation devices, an LED viewing light and the cryo transfer device vacuum storage tube. A shuttle mounting pillar gives a solid base for specimen mounting.The control electronics are mounted in a sealed but accessible cabinet beneath the Prepdek™. Touch screen user interfaceThe PP3010T is controlled using a large touch screen panel PC, mounted on the Prepdek™. User-de?ned ‘recipes’ can be entered and stored for instant future access. The screen can be set to suit operator preferences; for example, vacuum measurement can be displayed in millibar or Pascal.CCD images of both cold stages are displayed and can be expanded to full screen. Data logging of all parameters and vacuum status overview can be displayed. Operational guidance is instantly available through a series of on-screen videos. Why cryo-SEM?Cryo preparation techniques for scanning electron microscopy (SEM) are essential for the successful observation of wet or ‘beam sensitive’ specimens. Cryo-SEM removes the need for specimen-unfriendly conventional preparation techniques, such as critical point drying, allowing observation of specimens in a close-to-life hydrated state.The limitations of conventional ‘wet’ processing include:¦ Shrinkage, distortion and relocation and extraction of soluble materials¦ Mechanical damage - fragile specimens are easily damaged during conventional processing¦ For biological material toxic reagents are generally required (?xatives, buffers etc)¦ Long processing timesAdvantages of cryo-SEM¦ Specimen viewed in its fully hydrated state¦ Soluble materials are retained¦ Little or no mechanical damage¦ Ideal for time-resolved experiments (i.e. freezing at timed intervals)¦ High resolution capability (compared to low-vacuum techniques)¦ Extra information obtained by low-temperature fracturing ¦ Excellent for liquids, semi-liquids, foams and beam sensitive specimens¦ Rapid process: typically 5-10 minutesPP3010T overviewThe PP3010T is the very latest in cryo-SEM technology – combining the highest quality results with unparalleled ease of set up and use.The PP3010T is a column-mounted, gas-cooled cryo preparation system suitable for SEM, FE-SEM and FIB/SEM. Control is via a large and intuitive touch-screen panel PC mounted on the self contained Prepdek™ workstation. Visibility is a key feature throughout the whole system. CCD images from the preparation chamber and the SEM (?tted if space allows) are displayed on the control screen, and a large front window and top viewing ports give unsurpassed visibility of the specimen and chamber interior. The PP3010T includes facilities needed to rapidly freeze and transfer specimens. The aQuilo cryo preparation chamber has tools for cold fracturing and for fully automatic sublimation and specimen coating. Once prepared, the specimen can be transferred onto a high stability SEM cold stage for observation. Extensive cold trapping in the aQuilo cryo preparation chamber and SEM can be set to operate at temperatures down to below -190ºC, ensuring the whole process occurs in a contamination free, high-vacuum environment.Specimen holdersThe PP3010T comes with a variety of stubs and shuttles designed to accommodate most specimen types. Additional holders are also available, including for high pressure freezing rivets and planchettes.Handling and transferring specimensThe PP3010T Prepdek™ workstation is ?tted with a combined slushy Main display screen with all operational parameters visible to the user at all times Sublimation parameters for temperature and time can be pre-set and storedImages of both specimen cold stages can be expanded to ?ll the whole screen. Video images can be captured and savednitrogen freezing/specimen manipulation system, connected to the rotary pump. Rapid freezing reduces ice crystal damage resulting in enhanced specimen preservation.The spacious freezing system also allows specimens that have been frozen by alternative methods (or stored ?eld specimens) to be manipulated and mounted onto a suitable holder under liquid nitrogen. They can then be vacuum transferred into the aQuilo preparation chamber for subsequent processing and observation.Cryo transfer device and pumped storageThe compact cryo transfer device can comfortably be held in one hand for maximum ease of handling. The sealing mechanism ensures contamination free specimen exchange and the quick-release bayonet connection to the shuttle allows rapid specimen transfer. To ensure the cryo transfer device is maintained in a clean, vacuum compatible condition a pumped storage tube is ?tted into the Prepdek™ work surface.Gas-cooled cryo preparation chamberThe aQuilo cryo preparation chamber is connected directly to the SEM and includes a highly ef?cient nitrogen gas cooled specimen stage, extensive cold trapping (above and below the specimen) and facilities to fracture, sublimate and sputter coat specimens. Two fully integrated and interlocked gate valves allow transfer into the aQuilo chamber, followed by rapid high-vacuum to high-vacuum specimen exchange to and from the SEM stage.Ef?cient gas cooled specimen stage and cold trapsAt the heart of the aQuilo chamber is a nitrogen gas cooled specimen stage which can be precisely controlled over a temperature range from 100ºC to below -190º. Large gas cooled cold traps, located above and below the specimen stage, ensure clean, high vacuum conditions are maintained in the chamber. Both cold stage and cold traps are fed by the unique CHE3010 off-column cooling system (see next page), which typically gives hold times of up to 24 hours between ?lls.High visibility – plus CCD cameraThe aQuilo chamber has superb chamber visibility. In addition to the large front window (75 x 150mm) there are two top viewing ports. The chamber is lit by three LEDs and a CCD camera which allows the specimen cold stage area to be viewed on the control screen. Images can be saved and stored using the on-screen button. Cold fracturingActively cooled, twin fracturing tools manipulators are available and allow a range of specimen types to be cold fractured.Fitted as standard is a front mounted fracturing and manipulation device. The ball-jointed mount offers ?exible movement, allowing the blade to be used both as a surface pick (probe) and a fracturing knife. An optional micrometer advanced fracturing tool with rigid blade is available. Fractured fragments are captured in the large cold trap located below the specimen stage. Automatic sublimation and sputteringSublimation temperatures and times can be preset and stored for easy retrieval. The process is fully automatic and graphically displayed on the control screen, showing the actual and predicted temperature curves. The high resolution sputter coater will give ?ne grain ?lms essential for FE-SEM applications. A platinium target is ?tted as standard - other metals include gold, gold/palladium, chromium and iridium. Integrated options include a carbon ?bre evaporation accessory and a terminating ?lm thickness monitor (FTM).Cryo preparation chamber pumpingThe aQuilo chamber is evacuated by a remotely-positioned 70L/s turbomolecular pumping system, backed by a suitable rotary pump. Typical vacuum levels during operation are in the region of 10-6mbar or better. Positioning the turbomolecular pump away from the SEM ensures total elimination of mechanical vibration and signi?cantly reduces the mass connected to the SEM. The vacuum buffer tank “backs” the turbomolecular pump and is automatically evacuated by the rotary pump when required – typically for only a few minutes in each hour. Cryo transfer device with specimen shuttle and stub insertCryo preparation chamberOff-column cooling system with up to 24 hour runtimePreparation chamber front windowOff-column turbo-pumping systemPP3010T: Speci?cation highlightsSEM components: Nitrogen gas cooled SEM cold stage: -190ºC or lower, to +100ºC. Temperature stability: < 1ºC Nitrogen gas cooled SEM cold trap: -190ºC or lower SEM LED illumination and CCD camera (if space is allows)SEM cooling: CHE3010 off-column, 21 litre gas cooling system, typically with up to 24 hours hold timeColumn mounted aQuilo Nitrogen gas cooled cold stage: -190ºC, or lower to +100ºC. Temperature stability: < 1ºcryo preparation chamber Nitrogen gas cooled upper and lower cold traps held at -190ºC or lowerwith: Multiple LED illumination and CCD camera Actively cooled fracturing/manipulation tool, micrometer controlled knife (option) Large front window (150mm x 78mm) plus two top viewing ports Automated, high resolution sputtering (Pt standard) Optional ?lm thickness monitor and carbon ?bre evaporation attachment Automated sublimationPreparation chamber Floor-mounted turbo pumping with stainless steel vacuum connection to the preparation chamberpumping system: Base vacuum: 10-6mbar or better. Single 5m3/hr-1 or equivalent rotary vacuum pump requiredTouch-screen control 380mm/15” panel PCvia a panel PC: User de?nable “recipes” can be stored On-screen data logging, diagnostics and help videosPrepdek™ specimen Twin liquid nitrogen freezing and specimen handling system – ideal for handling pre-frozen specimenspreparation station: Includes work area for specimen preparation Pump storage for cryo transfer device, ?exible LED light and mounting pillarSEM cold stage and cold trapA highly stable, thermally isolated, nitrogen gas cooled stage attaches to the SEM stage using an adaptor. The SEM stage and cold trap are cooled by two separate cold gas circuits - both have rapid response and are capable of reaching temperatures down to -190ºC or lower.CHE3010 off-column, vacuum isolated gas cooling systemThe CHE3010 is a fully integrated, remotely positioned cooling system. The cold nitrogen gas generated is used to cool the entire PP3010T – i.e. SEM stage, SEM cold trap, aQuilo chamber cold stage and cold traps. The CHE3010 delivers temperatures down to -190ºC or lower. A key feature is that the cold gas is carried to the microscope under vacuum, giving not only superb thermal ef?ciency but also the option of ?exible site location (typically on the ?oor behind the microscope).SEM cold stageFood scienceCryo-SEM has for many years been an important technique in food science. Microstructure has a direct in?uence on the taste, texture and consumer preference. Emmental cheese. Yoghurt. Fractured, sublimated Ice cream. The PP3010T Prepdek™ is ?tted Fractured, no sublimation or coating and platinum coated with a specimen handling system which allows pre-frozen material, such as ice cream, to be manipulated and then transferred under vacuum into the cryo preparation chamber Biology Yeast. Intramembranous particles are around Predatory Mite. Sundew pollen (Drosera adelae). 9nm across and arranged in characteristic hexangonal arrays. Specimen cold fractured and sputtered with 4nm of platinium Cross-section through a leaf of Wax-producing cells and wax on the Euphorbia leaf surface Euphorbia myrsinites (donkey-tail spurge) (wax is often extracted during critical point drying processing) Materials Oils and rocks. Chalk rock saturated with brine X-ray microanalysis overlay of the same specimen is used to further and oil. Dark grey bubbles are oil droplets differentiate oil from water content (green: oxygen, red: carbon) in brine-?lled cracks Mixed hardness material. Cosmetic foundation cream (oil-water emulsion). Cryo-FIB/SEM section of a ceramic-?lled, laminated polymer. Comparing a cryo-SEM prepared specimen with cryo-FIB/SEM. A combination of hard and soft materials FIB-cut without Both images show large oil droplets, with the cryo-FIB/SEM image clearly demarcating damage or distortion. 2kV secondary electron image the water phase (light areas) and additives (dark areas) within the ice Images courtesy of Universities of Reading, Stavanger and York, Hitachi High Technologies (Japan), Nitto Analytical Techno-Center and USDA BeltsvilleCryo-SEM Cryo-FIB/SEM Quorum TechnologiesOrdering Information NB: For a full quotation, including on-site installation and customer training, please contact Quorum or your local distributorPP3010T Cryo preparation system for SEM, FE-SEM and FIB/SEM. Including: aQuilo column-mounted, cryo-preparation chamber and turbo pumping. SEM cold stage and cold trap, Prepdek™ workstation with freezing and specimen manipulation facilities, automatic sputtering and sublimation. CHE3010 off-column gas cooling system. Touch screen, panel PC user interface mounted on the Prepdek™ workstation. Cryo transfer device, 2 x AL200077B and 1 x 10246 specimen shuttles and the following specimen stubs: E7402 (pkt. 10), 5 x E7449, 5 x 11541, E7406 (pkt. 5), E7407 (pkt. 5) and 328116510 brass fracturing rivets (pkt. 100). Microscope interfaces, start-up kit and operation manual Pumping The PP3010T requires one 5m3/hr-1 rotary vacuum pump 13034 5m3/hr-1 rotary vacuum pump with oil mist ?lterOptions and PP7450/75L Pressurised LN2 dewar (60L). For “boil-off” cooling gas and LN2 for slushing accessories 13297 Sircal nitrogen gas dryer 220-240V (100-110V part:13298) 11920 Carbon ?bre evaporation head and power supply 12147 Terminating ?lm thickness monitor 12145 Micrometer controlled fracturing device with tool steel blade 13060 Two years spares and consumables kit for the PP3010TSpecimen AL200077B Standard specimen shuttle (holds a 10mm stub)holders 12434 Shuttle without 10mm hole (?at surface: 22mm x 13mm) 10245 Shuttle to hold Balzers style planchettes or small, ?at specimens 10246 Shuttle to hold 10mm stub – similar to AL200077B, but top clamping 10247 Shuttle to hold two freeze-fracture rivets – vice style 12406 Shuttle to accept two TEM autogrids™. Includes cryo shield E7433 Stub to hold four rivets – screw down style (for use with 10246) E7449 Universal specimen stub with holes and slots, 7mm high (pack of 5) 11541 Universal specimen stub with holes and slots, 5mm high (pack of 5) E7402 Aluminium stubs (pack of 10) E7403 Copper stubs (pack of 10) E7405 Screw down stub for thin specimens E7406 Copper stubs with 3 x 3mm slots (pack of 5) E7407 Copper stubs with 1 x 3mm slot (pack of 5) 32816510 Brass rivets for fracturing liquids (pack of 100)Sputtering E7400-314A Gold (Au) target 0.2mm thicktargets E7400-314C Platinum (Pt) target 0.2mm thick(24mm dia.) E7400-314F Chromium (Cr) target 0.3mm thick E7400-314IR Iridium (Ir) target 0.3mm thickLOT-QuantumDesign Europe. For your local contact click at: www.lot-qd.comE-Mail: info@lot-qd.com
Most popular related searches