Veris Industries

Current Switch H300 Datasheet

current monitoringVERIS INDUSTRIES800.354.8556 +1 503.598.4564 www.veris.comFEATURES ? More reliable for status than relays across auxiliary contacts? Ideal for direct-drive units, unit vents, fan coil units, exhaust fans, and other fixed loads? Great for lighting status–less expensive than 277V relays? Low 0.15 A turn-on (H300 and H600)...ideal for small exhaust fans (not intended to detect belt loss)? Removable mounting bracket provides installation flexibility? Bracket on H900 can be installed in three different configurations...installer convenience? Split-core H300, H600, and H900 for fast retrofit installation? Mini solid-core H800 and micro split-core H300 fit in tight enclosures... saves valuable panel space? 100% solid-state, no moving parts to fail? Polarity insensitive output? 5-year warrantySplit-Core & Solid-Core On/Off Status Current SwitchesH300H600H800H900DESCRIPTION Hawkeye x00 on/off current switches provide a cost-effective solution for monitoring status on unit vents, exhaust fans, recirculation pumps, and other fixed loads where belt loss is not a concern.Veris has applied new technology to the H300, H600, and H800 models to achieve impressive improvement in turn-on levels. The Hawkeye H300 and H600 now have the lowest turn-on current in the industry at a mere 150mAAPPLICATIONS? Monitoring status of electrical loads? Monitoring direct-drive units, exhaust fans, pumps, process motors, and other fixed loads? Verifying lighting run times Maximize ReliabilityMinimize Installed CostSPECIFICATIONSSensor Power (N.O. Models) Induced from monitored current Insulation Class 600VAC RMS (UL), 300VAC RMS (CE)Frequency Range 50/60 HzTemperature Range H800, H800NC, H300, H900: -15° to 60°C (5° to 140°F) H600: -15° to 40°C (5° to 104°F) (to 200A); -15° to 60°C (5° to 140°F) (to 150A) H800HV: -40° to 50°C (-40° to 122°F) (to 200A); -40° to 75°C (-40° to 167°F) (to 100A, & 0.25A status output) Humidity Range 10-90% RH non-condensingSensor Power (N.C. Models) 5-30VDC, permanently connectedOff State Leakage (N.C. Models) 34µA@5VDC, 200µA@30VDCOn State Voltage Drop (N.C. Models) 1.9VDC (max.) @0.1ATerminal Block Maximum Wire Size 14 AWG (16 AWG for H300)Terminal Block Torque (nominal) 4 in-lbs (7 in-lbs for H300)Agency Approvals UL 508 open device listing; CE:EN61010-1:2001-02, CAT III, deg. 2, basic insulationDo not use the LED status indicators as evidence of applied voltage.Current Switches: Fixed Trip Point US Patent No. 7,193,428 0.15 ATURN-ON Year Warranty5Hx00 SERIESTMHQ0001753.A 01121current monitoring800.354.8556 +1 503.598.4564 www.veris.comMODEL AMPERAGE RANGE STATUS OUTPUT (max.) TRIP POINT HOUSING UL CE RoHSH300 0.15 - 60A N.O. 1.0A@30VAC/DC 0.15A or less Split-core n n 2 nH600 0.15 - 200A N.O. 1.0A@30VAC/DC 0.15A or less Split-core n 1 n nH800 0.25 -200A N.O. 1.0A@30VAC/DC 0.25A or less Solid-core n 1 n nH800NC 0.5 - 200A N.C. 0.1A@30VDC 0.5A or less Solid-core n 1 nH800HV 0.75 - 200A N.O. 0.5A@250VAC/DC 0.75A or less Solid-core n 3H900 1.5 - 200A N.O. 1.0A@30VAC/DC 1.5A or less Split-core n nACCESSORIESDIN Rail Clip Set (AH01, AH27)DIN Rail (AV01) and DIN Stop Clip (AV02)DIMENSIONAL DRAWINGSAPPLICATION/WIRING DIAGRAMUnit Vent Heater ControlH300 H800, H800HV, H800NCH6001 Listed for use on 75°C insulated conductors.2 Product provides functional insulation only.3 Listed for use on 90°C insulated conductors.H900ORDERING INFORMATION RoHSCompliant* Terminal block may extend up to 1/8” over the height dimensions shown.Removable Mounting Bracket0.3”(8 mm)6 AWG max. 1.6”(40 mm)1.5”(38 mm)0.6”(15 mm)1.8”(46 mm)Ø 0.18” (x2)(5 mm)2.5" *(64 mm)2.1"(54 mm)3.5"(89 mm)2.9"(74 mm)0.4” x 0.2”(10 mm x 5 mm)Slot (2x)1.2"(31 mm)Removable Mounting Bracket0.7"(18 mm)0.5"(13 mm)2.1"(54 mm)1.0" *(26 mm)0.6"(16 mm) 0 0.7"(18 mm)0.4” x 0.2”Slot (x2)2.8" *(71 mm)1.7(43 mm)2.3"(58 mm)1.1" *(27 mm)0.9"(23 mm)Removable/Adjustable Mounting BracketRemovable Mounting BracketSelf-gripping Iris1.0”(25 mm)0.8”(21 mm)1.1”(26 mm)**3.1”(79 mm)2.8”(70 mm)Ø 0.3”(8 mm)1.4”* (36 mm)2.5”(64 mm)3.0”(76 mm)Bracket can be mounted on three sides for added installation ?exibility.POWERSOURCEPOWER SOURCE BUILDING AUTOMATIONCONTROLLERUNIT VENT HEATERDIDIAH01AH27AV01AV02HQ0001753.A 01121
Most popular related searches