Groupe Vauche

Densimetric Table Brochure

Groupe Vauché Europe EQUIPEMENTS POUR LE TRAITEMENT ET LA VALORISATION DES DECHETS CONSTRUCTEUR depuis 1860 DESCRIPTIVE CARD DENSIMETRIC TABLE CODE : TD 17-19, Boulevard Gambetta - 08200 SEDAN – France - Tél : (33) 03 24 29 03 50 - Fax : (33) 03 24 27 44 06 INTERNET : www.vauche.com - E-Mail : vauche@vauche.com Function Densimetric separation by dry roads of several components of a flow of products. Separator at 4 exits (heavy, ultra heavy ends, light and ultra light). Domaine d’application The densimetric table is used for maturing compost, rubble, timber, separation of homogenates industrial minerals ... etc.. It works on an input size from 50µ to 80mm. Caractéristiques générales Nomenclature Rep1 : Collecting cyclone of ultra light, Rep9 : Hopper of evacuation of the light fraction, Rep2 : Frame support of the cyclone Rep10 : Hood of collecting of dust, Rep3 : Lock rotary extraction of ultra light, Rep11 : Alimentation hopper Rep4 : Ventilator of fluidization, Rep12 : Inspection door with port-hole, Rep5 : Ventilator of aspiration Rep13 : Hopper of evacuation of the heavy fraction, Rep6 : Sheath connection, Rep14 : Bottom of treatment, Rep7 : Frame support of the densimetric table, Rep15 : Rods, Rep8 : Wind box, Rep16 : Motorization of the bottom of treatment 3 2 1 5 6 7 8 9 10 11 12 13 15 14 16 4 Groupe Vauché Europe EQUIPEMENTS POUR LE TRAITEMENT ET LA VALORISATION DES DECHETS CONSTRUCTEUR depuis 1860 DESCRIPTIVE CARD DENSIMETRIC TABLE CODE : TD 17-19, Boulevard Gambetta - 08200 SEDAN – France - Tél : (33) 03 24 29 03 50 - Fax : (33) 03 24 27 44 06 INTERNET : www.vauche.com - E-Mail : vauche@vauche.com Performances Tonnes/hour T/h) Powerof the FM table (kW) Power of the cyclone (kW) Total working installed capacity (kW) FM 100 0.5 à 3 8.6 16.1 24.7 FM 150 6 à 10 10.1 23.1 33.2 FM 300 15 à 20 20.7 40 60.7 These values are given as an indication on the basis of product having a granulometry 0-30mm, a density of 300Kg/m3 and a water content lower than 40%. All the guaranties of separation and of time capacity must be confirmed by a series of tests carried out in our office on the basis of the product to treat. Maintenance Two port-holes rep.12 give the visual control and access to the bottom of treatment rep.15 in order to facilitate maintenance. Several trap doors are also located on the network of sheath rep.7 and the cyclone rep.1. Protection of the personnel Conform to recommandations CRAM-INRS Diaporama Refining of glass by a FM150 in Brussels for BRUXELLES RECYCLAGE Refining of compost by a FM150 with Massa Carrara (Italy) for COLLING Spa
Most popular related searches