DiCom - Single Point Continuous H2S Perimeter Monitor Brochure
DI-COM Single Point Continuous H2S Perimeter Monitor APPLICATIONS • Perimeter monitoring • Nuisance odor monitoring • Remote air monitoring • Ambient air analysis • Regulatory compliance FEATURES • Detection range of 5 ppb to 2 ppm • Real-time Hydrogen Sulfide data • 4-20 milliAmp output • Datalogging • Wind speed and wind direction monitoring • Digital display for field viewing The Detection Instruments’ DI-COM H2S monitor is designed for continuous monitoring and recording of low level H2S emissions. The monitor is housed inside a NEMA 4X weatherproof enclosure and uses advanced OdaLog technology to provide continuous real-time data. The OdaLog displays the data for field viewing, provides a 4 to 20 mA signal and also stores the data for later downloading and viewing using the OdaStat software. A weather station measures wind speed, direction, and outside temperature. Small and compact, the system can easily be moved and installed at different locations. The monitor is powered by AC current and provides the 4 to 20 mA signal to a central location. A wire-less module with antenna is also available for communication to a central computer. In cases where AC power is not available, we supply a solar panel with back up battery to power the system. The system is simple to operate and can be calibrated in the field with our calibration gas kit. The calibration procedure takes approximately fifteen minutes to complete. 5815 North Black Canyon Highway · Suite 103 · Phoenix, Arizona 85015 · Phone: 602-797-0630 or 866-632-5647 Fax: 602-797-0631 · www.detectioninstruments.com OPTIONAL ACCESSORIES • Wireless module with antenna • Solar power • Central computer and proprietary soft-ware to accept data from 1 to 15 systems • Calibration gas kit to calibrate at 0.5 ppm, and for bump tests SPECIFICATIONS Monitoring device: OdaLog CEM 52 Resolution: 0.001 ppm Measurement range: 0.005 - 2.00 ppm Precision: 5% Relative Standard Deviation Accuracy +/- 5 ppb below 0.1 ppm; +/- 5% from 0.1 - 2 ppm Flow rate 0.15 lpm Maintained temperature range 75º - 90º F Power 115 Vac Enclosure NEMA 4X Dimensions 16” x 8” x 9” Datalogging 10 to 60 minutes, user selectable Weight 24 pounds Warranty One year, factory parts and labor The monitor provides real-time data via a 4 to 20 milliAmp signal. The data can be transmitted using a wire-less module to a central computer, which can monitor up to fifteen systems. Hydrogen sulfide and temperature data can also be stored and viewed using OdaStat software. Example of Compiled Data using DI-COM Software DI-COM Single Point Continuous Hydrogen Sulfide Perimeter Monitor Specifications System Specifications Maintained Temperature Range: 40 degree F, minimum Power: 115 VAC, single phase, 25W, or solar cell 20 amp hour reserve power Circulating Fan: 0.05 Amps Vent Fans: 0.10 Amps Heater: Varied, dependent on environmental conditions Control Board: 50 mA Enclosure: NEMA 4X, locking Dimensions: 20 x 16 x 8 Weight: 24 pounds Instrument Specifications Monitoring Device: OdaLog CEM 52 Resolution: 0-.001 PPM Measurement Range: 0.005 - 2.00 PPM Precision: 5% Relative Standard Deviation Accuracy: +/- 5 PPB below 0.1 PPM; +/- 5% from 0.1 - 2 PPM Flow Rate: 0.15 LPM Logging Frequency: 10 to 60 minutes, user selectable Memory Capacity: 30,000 data points Output: 4 to 20 milliAmp Weight: 2 pounds Optional Central Communication Computer System Requirements Windows operating system on dedicated computer Voice Modem for optional telephone notification Free serial port, Base Station Transceiver Communications Parameters 9600 Baud, 8 data bits, no parity, 1 stop bit, no handshaking Pasive 4 to so millAmp Loop Logging/Sampling Interval 10 minutes to 1 hour Specification, XStream X09-009PKC-R RF Modem Performance Power Output: 100 mW (20 dBm) Indoor/Urban Range: up to 1500' (450m) Outdoor/RF Line-of-sight Range: up to 20 miles (32 km) Receiver Sensitivity: -110 dBm (@ 9600 bps) RF Data Rate: 9.6 Kbps Interface Data Rate: up to 57.6 Kbps Networking Spread Spectrum Type: FHSS (Freqeuncy Hopping Spread Spectrum) Supported Network Topologies: Peer-to-peer, point-to-point point-to-multipoint & multidrop Error Handling: Retries & acknowledgements Filtration Options: VID (Vendor ID Number), channels and addressing Channel Capacity: 7 hop sequences share 25 frequencies Addressing: 65,000 network addresses available for each channel Power Supply Voltage: 7 - 18 V Transmit Current: 170 mA Receive Current: 70 mA Power-down Sleep Current: < 1 mA General Frequency Band: 902 - 928 MHz Data Connection: Female DB-9 Physical Properties Size: 2.750" x 5.500" x 1.125" (6.99cm x 13.97cm x 2.86cm) Weight: 7.1 oz (200g) Antenna Options: RPSMA (Reverse Polarity SMA) Operating Temperature: 0 to 70° C (commercial) Certifications: FCC: OUR9XSTREAM IC: 4214A-9XSTREAM Class 1 Division 2: Approved 5815 North Black Canyon Highway · Suite 103 · Phoenix, Arizona 85015 · Phone: 602-797-0630 or 866-632-5647 Fax: 602-797-0631 · www.detectioninstruments.com
Most popular related searches