Frisenette ApS
- Home
- Companies & Suppliers
- Frisenette ApS
- Downloads
- Dismic Syringe Filters Brochure
Dismic Syringe Filters Brochure
Syringe FiltersDISMIC Disposable Syringe Filter UnitsLABODISC Disposable In-Line/Syringe Filter Units The Advantec range of DISMIC syringe filters is versatile in terms of volume to be filtered and which kind of liquids to be filtered.• 3 mm filters for volumes <2 ml• 13 mm filters for volumes <10 ml• 25 mm filters for volumes <50 ml• 50 mm filters for volumes <1 literDifferent membrane types and filter housings available for any kind of filtration. Some types available both non-sterile and sterile.Features• Minimum sample hold-up: Unit housings are specifically designed to maximize sample recovery• High Purity: Non-pigmented housings and integral filter sealing assure that filtrates will not be adulterated due to pigment, dye or adhesives leaching into filtrate• Convenient: Each unit is clearly marked with an identifying code to denote pore size, membrane material and housing material• Sterile: Units can be purchased presterilized and individually packed or non-sterile in bulk pack (all polypropylene can be autoclaved)18Syringe FiltersMembrane TypesCharacteristicsCellulose AcetateA commonly used hydrophilic membrane.Low protein binding, suitable for aqueous protein solutions.Suitable for most alcohols.PTFE, hydrophobicIdeal for filtration of solvents, acids and bases.Air venting.Ordering InformationDiameter [mm]Membrane materialPore size (µm)Housing materialPackingCat. No. Non-sterileCat. No. Sterile3 Cellulose Acetate 0.20 Polypropylene 100 03CP020AN 03CP020AS3 Cellulose Acetate 0.45 Polypropylene 100 03CP045AN 03CP045AS3 PTFE, hydrophobic 0.50 Polypropylene 100 03JP050AN -Specifications: DISMIC 3 DISMIC 13 DISMIC 25 LABODISCHousing material PP PP PP Acrylic PPHousing diameter [mm] 3 13 25 25 50Filtration area [cm2] 0.06 0.9 4.0 4.0 19.6Hold-up volume [ml] <0.01 <0.03 <0.1 <0.1 <3.0Sample volume [ml] <2 ml <10 ml <50 ml <50 ml <1 literPressure limit [psi] 74 74 74 74 49Max. operating temperature [°C] 60 60 60 45 60Connections Inlet: female luer-lock / Outlet: male luer slip7-13.5 mm hose barb, female luer slipDISMIC 3 Membrane Types and Ordering InformationDISMIC – Disposable Syringe Filter UnitsNote: Pressure limits for DISMIC 13HP and DISMIC 25HP is 57 psi.19Syringe FiltersDISMIC – Disposable Syringe Filter UnitsMembrane TypesCharacteristicsCellulose Acetate A commonly used hydrophilic membrane.Low protein binding, suitable for aqueous protein solutions.Suitable for most alcohols.PTFE, hydrophobic Ideal for filtration of solvents, acids and bases.Air venting.PTFE, hydrophilic Versatile: Suitable for both solvents and aqueous solutions.Ideal for filtering HPLC samples. Studies has shown that hydrophilic PTFE has a low binding of Pesticides. The models in blister packs, Cat. Nos.13HP020CN and 13HP045CN, are specially manufactured for Ion Chromatograhpy analysis. Ordering InformationDiameter [mm]Membrane materialPore size (µm)Housing materialPackingCat. No. Non-sterileCat. No. Sterile13 Cellulose Acetate 0.20 Polypropylene 100 13CP020AN 13CP020AS13 Cellulose Acetate 0.45 Polypropylene 100 13CP045AN 13CP045AS13 PTFE, hydrophobic 0.20 Polypropylene 100 13JP020AN -13 PTFE, hydrophobic 0.50 Polypropylene 100 13JP050AN -13 PTFE, hydrophilic 0.20 Polypropylene 100 13HP020AN -13 PTFE, hydrophilic 0.45 Polypropylene 100 13HP045AN -13 PTFE, hydrophilic 0.20 Polypropylene 50 13HP020CN -13 PTFE, hydrophilic 0.45 Polypropylene 50 13HP045CN -DISMIC 13Membrane Types and Ordering Information13CP AN / AS13JP13HP13HP in blister packTable of Negative Ion elution comparisonItem F– Cl– No2– Br– No3– PO43– SO42–13HP020CN ND* 16.0 ND ND ND ND ND13HP045CN ND 10.2 ND ND ND ND NDA company filter unit ND 56.6 ND ND 7.6 ND 35.6B company filter unit ND 22.6 ND ND ND ND NDC company filter unit ND 14.0 ND ND 90.4 ND 88.6*) No Detection: less than detection limit20Syringe FiltersDISMIC – Disposable Syringe Filter UnitsMembrane TypesCharacteristicsMixed Cellulose EsterA hydrophilic membrane with high porosity which provides a high flow rate.This type will bind proteins.Cellulose AcetateA commonly used hydrophilic membrane.Low protein binding, suitable for aqueous protein solutions.Suitable for most alcohols.PTFE, hydrophobicIdeal for filtration of solvents, acids and bases.Air venting.PTFE, hydrophilicVersatile: Suitable for both solvents and aqueous solutions.Ideal for filtering HPLC samples. Studies has shown that hydrophilic PTFE has a low binding of Pesticides.Ordering InformationDiameter [mm]Membrane materialPore size (µm)Housing materialPackingCat. No. Non-sterileCat. No. Sterile25 Mixed Cellulose Ester 0.20 Acrylic 50 25AS020AN 25AS020AS25 Mixed Cellulose Ester 0.45 Acrylic 50 25AS045AN 25AS045AS25 Cellulose Acetate 0.20 Acrylic 50 25CS020AN 25CS020AS25 Cellulose Acetate 0.45 Acrylic 50 25CS045AN 25CS045AS25 Cellulose Acetate 0.80 Acrylic 50 25CS080AN 25CS080AS25 PTFE, hydrophobic 0.20 Polypropylene 50 25JP020AN 25JP020AS25 PTFE, hydrophobic 0.50 Polypropylene 50 25JP050AN -25 PTFE, hydrophilic 0.20 Polypropylene 100 25HP020AN -25 PTFE, hydrophilic 0.45 Polypropylene 100 25HP045AN -DISMIC 25 Membrane Types and Ordering Information25AS AN / AS25CS AN / AS25JP25HP21 Frisenette_Advantec Catalogue_2010_WEB.pdf
Most popular related searches
