Ditabis AG
Ditabis - Model 25 - Imaging Plate Scanner Micron - Flyer
The DITABIST Imaging Plate Technology is de-signed to replace conventional sheet film in the transmission electron microscope. It provides a new level of digital resolution and dynamic range to TEMs by viewing the same wide field of view as film with up to 6000 x 5000 pixels resolution. Having 10 times the sensitivity of film and a six orders of magnitude dynamic range this technol-ogy exceeds the performance of any other digital or analog system. Unlike CCD cameras the Imag-ing Plates can be used with the same routines as conventional film but without the need for wet chemistry. Reusable plates and their suitability to single or multiple instruments make the micron Vario the most cost effective high resolution dig-ital TEM solution.6000 X 5000 PixelsDigital Imaging for TEM• Extraordinary image quality• Highest sensitivity and dynamic range• 6000 x 5000 pixels in traditional film image area• Cost effective – reusable plates – serves multiple TEMs• Easy to use – direct replacement for film• No installation required on the TEM• No wet chemistry micron VARIOScalable Resolution: Readout Pixel Size 50µm – 15 µmImaging Plate Technology for Life Science & Material ScienceSystem SpecificationsReadout Pixels micron Vario From 6000 x 5000 max. at 15,0 µm to 1800 x 1600 max. at 50,0 µm micron 25 From 6000 x 5000 max. at 15,0 µm to 1800 x 1600 max. at 50,0 µmImaging Plate Size 81 x 100 mmEffective Area 80 x 90 mmReadout Time 2 – 3 min / frameA/D-Conversion 2 channels of 16 bit at different gains, 20 bit combinedDynamic Range 6 orders of magnitude at one scanPower 230 V – 50 Hz; 120 V – 60 Hz, 100 WDimensions (W/D/H) 675 /580 /305 mmWeight 60 kgOS Platforms Easy to use Windows 98/NT/2000/XP/7Scanning Full software control of all parameters, featuring application specific parameter setsData Format 16 / 24 /32 bit data format with comment and setting information in headerImage Viewer Quick preview, zoom and look-up-tables, data base functionsImage Processing Various filters and arithmetic functions; alignment, rotation, thresholdCorrection Functions Background correctionAnalyse Functions Points, lines and areas, 2D-FFT, 3D-Plot, peak measurement functionData Conversion Data export to TIFF, PCX, GIF, JPEG, change of resolution and dynamic rangeMore information: www.ditabis.deDITABIS AG: Digital Biomedical Imaging Systems AG | Freiburger Straße 3 | 75179 PforzheimE-Mail: contact@ditabis.de | Phone: +49 (0) 7231 29 863 00 | Fax: +49 (0) 7231 29 863 01High definition TEM image of a plant cell (3000 x 3000 pixels) Detail of left image. When zooming in plenty of details become visible.High resolution image of silicon film at 590 000 primary magnification.Convergent Beam Electron Diffraction of thin silicon film. The high contrast range was recorded on one image and has been compressed for printing.
Most popular related searches
