Status Instruments Ltd.
- Home
- Companies & Suppliers
- Status Instruments Ltd.
- Downloads
- DM3410 - RTD / Thermocouple Input Panel ...
DM3410 - RTD / Thermocouple Input Panel Meter Data Sheet
INTELLIGENT DIGITAL INDICATORS DM3400 SERIES DM3410 (Pt100, T/C) DM3420 (CURRENT, VOLTAGE) BUILT IN 24V PSU FOR TRANSMITTER EXCITATION (DM3420) IP65 FRONT PANEL SEALING PLUG & PLAY POD OPTIONS FOR RELAY / CURRENT OUTPUT INTRODUCTION The DM3400 series uses proven technology to accept all commonly used temperature or process inputs. Engineering units are displayed on a high efficiency Red LED display that provides excellent readability. The DM3410 takes inputs directly from Pt100 or Thermocouple sensors for Temperature indication. The DM3420 current and voltage for Process indication. The DM3420 also has a transmitter power supply built in for excitation of 2 wire (4 to 20) mA process transmitters. The highly innovative case design enables output option ‘Pods’ to be easily installed without the need for dismantling or re-calibration. ‘Plug and Play’ Pods are available covering: • POD-02 2 x Relay outputs • POD-03 Active or Passive Isolated re-transmission ((0 to 10) mA, (0 to 20) mA, (4 to 20) mA) A maximum of 2 POD outputs can be fitted to each indicator. The indicator provides a transmitter power supply on the output to excite the POD-03 current retransmission. Output combinations are • Dual Relay Pod and Retransmission Pod • Dual Relay Pod and Dual Relay Pod • Dual Relay Pod • Retransmission Pod The front panel is sealed to IP65 and the case has a moulded in rubber gasket enabling it to seal to the panel maintaining the IP65 rating, ideal for installing it in ‘dusty’ areas or where low pressure jets of water are used to clean down equipment. The unit is programmed using the three push buttons on the front panel where the user is guided through the configuration process. INTELLIGENT DIGITAL INDICATORS SPECIFICATIONS @ 20 °°°° C DM3410 UNIVERSAL TEMP. INDICATOR The DM3410 accepts all common thermocouple and RTD types and displays the temperature digitally. RTD (Pt100) Sensor Range (-200 to 850) °C, (18 to 390) ? Linearisation Standard BS EN 60751 (IEC-751) BS 1904 (DIN 43760), JISC 1604 Basic Measurement Accuracy 0.1 °C ± 0.05 % rdg Thermal Drift Zero 0.008 °C/ °C Span 0.01 %/ °C Excitation Current (300 to 550) µA Lead Resistance Effect 0.002 °C/ ? Maximum Lead Resistance 50 ? / leg THERMOCOUPLE (K,J,T,R,S,E,L,N) Basic Measurement Accuracy ± 0.04 % FRI ± 0.04 % rdg or 0.5 ºC (whichever is greater) FRI = Full Range Input Linearisation Standard BS EN 60584-1 (IEC 584-1) Cold Junction Error ± 0.5 °C Cold Junction Tracking 0.05 °C/ °C Cold Junction Range (-30 to 60) ºC Thermal Drift Zero 0.1 µV/ °C Span 0.01 %/ °C DM3420 PROCESS INDICATOR The DM3420 accepts all common process signals, current or voltage, and displays the signal digitally in engineering units. An internal power supply provides excitation for field transmitters. PROCESS Voltage Range (0 to 1) V (1 to 5) V (0 to 10) V Accuracy 0.05 % FS Thermal Drift Zero 0.1 µV/ °C Span 0.01 %/ °C Current Range (0 to 20) mA (4 to 20) mA (0 to 10) mA Input Impedance 47 ? (current) 1 M? (voltage) Accuracy 0.05 % FS Thermal Drift 0.01 %/°C Excitation 24 V ± 5 % @ 50 mA Linearisation Linear, Square Root or Custom GENERAL Input/Output Isolation 500 VAC rms (Galvanically Isolated) Update Time 250 ms maximum Time Constant (Filter off) < 1 s (to 63 % of final value) Filter Factor Programmable Off, 2 s, 10 s or Adaptive Warm-up Time 120 s to full accuracy Display Range -999 to 9999 Power Supply S1 (90 to 253) VAC, (50 to 60) Hz S2 (20 to 35) VDC Power Consumption 6 VA maximum (options fitted) DISPLAY 4 Digit RED LED Standard 14.2 mm high/high intensity 4 Alarm RED LED Indicators 2.5 mm high numeric (Only when Relay option is fitted.) ENVIRONMENTAL Sealing PANEL IP65 Ambient Operating Range (-30 to 60) °C Ambient Storage Temperature (-50 to 85) °C Ambient Humidity Range (10 to 90) % RH non condensing APPROVALS EMC Emissions BS EN50081-1 Susceptibility BS EN50082-2 ELECTRICAL SAFETY BS EN61010-1 UL Approved OUTPUT OPTIONS PLUG AND PLAY OPTION PODS Simple plug in pre-calibrated units, no dismantling or re- calibration. POD-3000/02 DUAL RELAY ALARM Two independent mains rated relay outputs (common connection). Contacts 2 x Changeover relays common wiper Ratings AC DC Maximum Load 5 A @ 250 V 5 A @ 30 V Maximum Power 1250 VA 150 W Maximum Switching 253 V 125 V Electrical Life 105 operations at rated load Mechanical Life 50 million operations Termination Screw terminals POD-3000/03 ISOLATED RE-TRANSMISSION Ranges (0 to 10) mA (Active or Passive) (0 to 20) mA (Active or Passive) (4 to 20) mA (Active or Passive) Minimum Current Output 0 mA Maximum Current Output 23 mA Accuracy 0.07 % F.S. Max. Output Load Active 1 K? Passive [(Vsupply-2)/22] K? Max. External Supply Voltage 30 V (Passive mode) Voltage Effect 0.2 µA/ V Ripple Current < 3 µA Breakdown Isolation 500 VAC Stability 1 µA/ °C Termination Screw terminals INTELLIGENT DIGITAL INDICATORS Status Instruments Ltd Tel: +44 (0)1684 296818 Green Lane Business Park Fax: +44 (0)1684 293746 Green Lane, Tewkesbury Email: sales@status.co.uk Gloucestershire, UK Website: www.status.co.uk GL20 8DE D2203-01-04 CN5010 DM3400 Series data sheet MECHANICAL Material ABS/PC Flammability IEC707 FV0 UL 94VO Weight 230 g Panel cut out (92 x 45) mm ALL DIMENSION IN mm OPTIONAL POD * Note: Supplied as standard unless otherwise specified 53.516.019.513.543.5ORDER CODE Universal Temperature 1 Universal Process 2 SERIES DM34 RED LED DISPLAY 0 / Power Supply (90 to 253) VAC (50 to 60) Hz S1* Power Supply (20 to 35) VDC S2 OPTIONS POD –3000/02 Dual Relay Output (2 per unit max) POD –3000/03 Isolated (4 to 20) mA re-transmission (1 per unit max) 2 3 41Tag No.48.096.0Vac11.0 131.0 BEHIND BEZEL10.0 MAX PANEL THICKNESS140.0PANEL CLAMPOPTION PODCLAMPING SCREW
Most popular related searches
