Marsh Industries Limited

Domestic Sewage Treatment Plants

• Made for domestic & commercial off mains drainage • Designed & tested to EN 12566-3 • The plant has low visual impact with unobtrusive lids • Normally only needs a granular surround. • The self aligning low profile means faster installation• Estimated annual running costs of £52 for six persons • Easy access, with integral separate de-sludge pipe • Almost silent running & odour free • Manufactured in the United Kingdom and is backed with a 25 year structural guarantee. • Invert risers and pumped outlets can be supplied for deeper drain connections • Designed with integral recycling system that makes it ideal for intermittent use. • Approved for discharging into a watercourse, ditch or land drainage bed. • Listed on the British water web pages Marsh ENsign Rangewww.marshindustries.co.uk T. 0044 1933 654582F. 0044 1933 654583 E. sales@marshindustries.co.ukMarsh ENsign RangeSewage Treatment Plants From 6 – 50PESix Person to Fifty PersonThe Strongest Sewage Treatment Plant on the Market• Tested • Approved • Certified • Ex-Stock • Great Value • High Performance• Low Running & MaintenanceMade in the United Kingdom34178 MARSH ENSIGN RANGE 8pp Brochure.indd 1 21/03/2012 16:26Marsh ENsign RangeIntroductionMarsh Industries is an independent British company based in Kettering Northamptonshire. We manufacture Sewage, Drainage and Water Recycling products, supplying major UK Builders & Civil Engineering Merchants. We are also used and specified by major contractors and institutions such as the National Trust, English Heritage, British Waterways, RSPCA and the Environment Agency.Major capital investment in new tooling, patterns, moulds along with product development has resulted in us being able to offer extremely competitive priced products that have been tested and certified to the relevant part of EN12566. We are able to offer two fully tested EN12566-3 sewage plant ranges for domestic drainage, the Ensign range from 6PE -50PE and the Ultra Polylok range 6-300PE. The ENsign range is available in ten separate ranges 6PE, 10PE, 12PE, 16PE, 20PE, 25PE, 30PE, 35PE, 40PE & 45-50PE all Ensign sewage plants are a single tank design. The Ultra Polylok 6PE and 12PE give a high performance sewage treatment process on a smaller footprint and installation depth, the Ultra Polylok 6PE is only 2200mm depth and 1700mm diameter. The plants come either with stainless steel lifting eyes or slinging points, this with the self-levelling and our unique quick fit drain connections, means installation can be carried quickly and safely. All our sewage plants are fitted with low energy efficient compressors, with low annual service and running costs and are certified for discharge direct. Marsh Industries does not use chalk fillers in its glass and resin mix, all our sewage and drainage products are made from Glass & Resin supplied by major UK manufacturers.Part of the production units at Kettering34178 MARSH ENSIGN RANGE 8pp Brochure.indd 2 21/03/2012 16:26Marsh ENsign Range‘Ask Marsh’-Questions & AnswersWe enclose a brief question and answer page that may assist. If you have another question pleased either phone on 01933 654582 or email sales@marshindustries.co.ukFor Sewage Treatment PlantsQuestion: Does a sewage plant have to meet a UK Standard?Answer: The ENsign plant has been tested to EN12566:3-2005 this is highest testing standard for European testing. The high test results mean the ENsign can discharge direct to a ditch, watercourse or percolation bed. Question: Why should I buy the Marsh Ensign plant? and does it smell and is it noisy?Answer: The ENsign Sewage plant is manufactured in the United Kingdom. The plant is odourless and operates almost silently and is backed with a 25 year structural guarantee. The ENsign Sewage plant is extremely energy efficient and normally only requires 30 minutes of annual maintenance. The six person ENsign Sewage plant is extremely strong and is only 1.95m in depth with an inlet invert of 500mm, this design reduces both the time and cost of installation, in normal ground conditions the unit only requires a pea-shingle surround. Question: What is a pumped outlet?Answer: A pump is fitted into the Marsh ENsign plant where there is no natural fall of gravity from the outlet pipe. The pump allows the effluent to be pumped to a higher level. We recommend the compressor is sited externally when a pump is fitted, together with a high level alarm. The Marsh ENsign design means that the pump is easy to fit and accessible and means a separate pump chamber does not need to be installed saving both money and time.Question: I have been told you cannot fit a sewage plant into my driveway.Answer: You can fit a Marsh ENsign plant, the plant can be adapted, so if required it can be installed in a vehicle driveway, please contact by phone or email for more details.Question: I need a treatment plant for my holiday home, it will not be used all the time, and will it smell?Answer: No, The ENsign is designed with an internal recycling-system, this means the ENsign plant is ideal for intermittent use. The recycling system stops the primary chamber becoming septic.Question: My drain is deep can I still connect up to the ENsign Treatment plant?Answer: Yes we can supply invert risers which cater for deeper inlet connection up to a further 1metre.Question: Are sewage plants expensive to run? Should I look at a non electric Bio-system?Answer: No, the power of a Marsh ENsign Six Person plant is 50w this means the running cost is approx. £52.00 per annum. Bio-systems are normally designed with a very deep outlet that can mean a pump needs to be fitted, which has a higher running cost than that of a compressor. Some need full concrete surrounds, and the layers of media in a Bio-system will need cleaning and also it requires a large separate primary chamberQuestion: Is there a sewage plant suitable for multiple dwellings or industrial sites?Answer: The Marsh ENsign Sewage treatment plants are designed for both domestic and commercial buildings with no access to the main sewer network. We sell sewage plants up to 300 persons. Please contact us so we can prepare a quotation and Loads and Flows table that can be used to gain planning and EA/SEPA approvals.Question: Will an unsightly lump or cover be showing in my garden, where my sewage plant would be?Answer: No for gravity outlets the compressor is housed in the unit keeping the visual impact and any noise to an absolute minimum. For pumped outlets we recommend housing the compressor externally in a discreet “bird house design” housing that can be up to 10m from the sewage plant.Question: How do I install the Marsh ENsign unit?Answer: The ENsign plant comes with lifting eyes to make unloading installation faster and safer.??We designed the Ensign plant to self-level on the base and with our unique pipe connections ensure the installation is undertaken efficiently and correctly. The six person ENsign Sewage plant is extremely strong and is only 1.95m in depth with an inlet invert of 500mm, this design reduces both the time and cost of installation, in normal ground conditions the unit only requires a pea-shingle surround. For guidance ideally the Ensign plant should be 7m from a dwelling or10m from a stream.Part of the production units at Kettering34178 MARSH ENSIGN RANGE 8pp Brochure.indd 3 21/03/2012 16:26Marsh ENsign RangeAPPROX EST. FOR THE CORRECT PLANT SIZE 6PE 10PE 12PE 16PE 20PE 25PE 30PE 35PE 40PE 45-50PESUITABLE FOR ANY OF THESE COMBINATIONS 4 bedresidence6 people2 no. 3 bed residences 10 people2 no. 4 bed residences 12 people2 no. 4 bed & 1 no. 3 bed residences 16 people3 no. 4 bed residences 18 people4 no. 4 bed residences 24 people5 no. bed or 6 no. 3 bed residences 30 people7 no. 3 bed residences 35 people8 no. 3 bed residences 40 people9 no. 3 bed residences 45 peopleAT WORK OR OFFICE NO CANTEEN 9 people working15 people working18 people working25 people working32 people working38 people working48 people working56 people working72 people working80 people workingHEIGHT TANK 1900mm 1900mm 2200mm 2300mm 2300mm 2300mm 2300mm 2300mm 2300mm 2300mmWIDTH TANK 1600mm 1600mm 1930mm 1930mm 1930mm 1930mm 1930mm 1930mm 1930mm 1930mmLENGTH TANK 2540mm 2540mm 2800mm 2800mm 3500mm 3500mm 4210mm 4210mm 5400mm 5400mmGROUND LEVEL TO INLET INVERT 500mm 500mm 600mm 600mm 600mm 600mm 600mm 600mm 600mm 600mmGROUND LEVEL TO OUTLET INVERT 575mm 575mm 675mm 675mm 675mm 675mm 675mm 675mm 675mm 675mmCOMPRESSOR BLOWER (INTERNAL OR EXTERNAL AVAILABLE) Internal Internal Internal Internal Internal Internal Internal Internal Internal InternalMAX. POWER CONSUMPTION 50w 60w 100w 120w 120w 150w 220w 220w 240w 250wEFFLUENT QUALITY 15:30:20 15:30:20 15:30:20 15:30:20 15:30:20 15:30:20 15:30:20 15:30:20 15:30:20 15:30:20GRAVITY OR PUMPED OUTLET Both available Both available Both available Both available Both available Both available Both available Both available Both available Both availableINVERT RISERS AVAILABLE Yes Yes Yes Yes Yes Yes Yes Yes Yes YesDESLUDGING FULL LOADING MONTHS 12 12 12 12 12 12 12 12 12 12WEIGHT EMPTY (APPROX.) 250kg 250kg 360kg 375kg 500kg 600kg 700kg 740kg 800kg 835kgTESTED & CERTIFIED TO EN12566-3 Yes Yes Yes Yes Yes Yes Yes Yes Yes YesVOLUME OF SURROUND CONCRETE PEASHINGLE 2m2 2m2 3m2 3.2m2 3.9m2 4m2 4.6m2 4.6m2 6m2 6m2A treatment system for a single house with up to and including 3 bedrooms shall be designed for a minimum population (P) of 5 people.The size of a treatment system for a single house with more than 3 bedrooms shall be designed by adding 1 P for each additional bedroom to the minimum single house value of 5 Pe.g.: • House with 3 bedrooms = minimum 5 P system • House with 4 bedrooms = minimum 6 P system (5+1) • House with 6 bedrooms = minimum 8 P system (5+3) will be 31 P (38 x 0.8 = 30.4)For groups of small 1 and 2 bedroom houses or flats • Flat with 1 bedroom = allow 3 P • Flat with 2 bedrooms = allow 4 PA treatment system serving a group of houses shall be designed by adding together the P values for each house calculated independently eg: • For a group of two houses (3 and 4 bedrooms, respectively) the system shall be for a minimum of 11 P (5+6)If the calculated total P for a group of houses exceeds 12 P then some reduction may be made to allow for the balancing effects on daily flow of a group of houses (round UP not down) • Where the total is 13-25 P multiply the total by 0.9 to give an adjusted P value, e.g. if there are four four-bedroom houses the total P will be 24 P (4 x 6) and the adjusted P will be 22 P (24 x 0.9 = 21.6) • Where the total is 26-50 P multiply the total by 0.8 to give an adjusted P value, e.g. if there are four three-bedroom houses and three four-bedroom houses the total P will be 38 P (4 x 5 and 3 x 6) and the adjusted P 34178 MARSH ENSIGN RANGE 8pp Brochure.indd 4 21/03/2012 16:26APPROX EST. FOR THE CORRECT PLANT SIZE 6PE 10PE 12PE 16PE 20PE 25PE 30PE 35PE 40PE 45-50PESUITABLE FOR ANY OF THESE COMBINATIONS 4 bedresidence6 people2 no. 3 bed residences 10 people2 no. 4 bed residences 12 people2 no. 4 bed & 1 no. 3 bed residences 16 people3 no. 4 bed residences 18 people4 no. 4 bed residences 24 people5 no. bed or 6 no. 3 bed residences 30 people7 no. 3 bed residences 35 people8 no. 3 bed residences 40 people9 no. 3 bed residences 45 peopleAT WORK OR OFFICE NO CANTEEN 9 people working15 people working18 people working25 people working32 people working38 people working48 people working56 people working72 people working80 people workingHEIGHT TANK 1900mm 1900mm 2200mm 2300mm 2300mm 2300mm 2300mm 2300mm 2300mm 2300mmWIDTH TANK 1600mm 1600mm 1930mm 1930mm 1930mm 1930mm 1930mm 1930mm 1930mm 1930mmLENGTH TANK 2540mm 2540mm 2800mm 2800mm 3500mm 3500mm 4210mm 4210mm 5400mm 5400mmGROUND LEVEL TO INLET INVERT 500mm 500mm 600mm 600mm 600mm 600mm 600mm 600mm 600mm 600mmGROUND LEVEL TO OUTLET INVERT 575mm 575mm 675mm 675mm 675mm 675mm 675mm 675mm 675mm 675mmCOMPRESSOR BLOWER (INTERNAL OR EXTERNAL AVAILABLE) Internal Internal Internal Internal Internal Internal Internal Internal Internal InternalMAX. POWER CONSUMPTION 50w 60w 100w 120w 120w 150w 220w 220w 240w 250wEFFLUENT QUALITY 15:30:20 15:30:20 15:30:20 15:30:20 15:30:20 15:30:20 15:30:20 15:30:20 15:30:20 15:30:20GRAVITY OR PUMPED OUTLET Both available Both available Both available Both available Both available Both available Both available Both available Both available Both availableINVERT RISERS AVAILABLE Yes Yes Yes Yes Yes Yes Yes Yes Yes YesDESLUDGING FULL LOADING MONTHS 12 12 12 12 12 12 12 12 12 12WEIGHT EMPTY (APPROX.) 250kg 250kg 360kg 375kg 500kg 600kg 700kg 740kg 800kg 835kgTESTED & CERTIFIED TO EN12566-3 Yes Yes Yes Yes Yes Yes Yes Yes Yes YesVOLUME OF SURROUND CONCRETE PEASHINGLE 2m2 2m2 3m2 3.2m2 3.9m2 4m2 4.6m2 4.6m2 6m2 6m2For groups of small 1 and 2 bedroom houses or flats • Flat with 1 bedroom = allow 3 P • Flat with 2 bedrooms = allow 4 PA treatment system serving a group of houses shall be designed by adding together the P values for each house calculated independently eg: • For a group of two houses (3 and 4 bedrooms, respectively) the system shall be for a minimum of 11 P (5+6)If the calculated total P for a group of houses exceeds 12 P then some reduction may be made to allow for the balancing effects on daily flow of a group of houses (round UP not down) • Where the total is 13-25 P multiply the total by 0.9 to give an adjusted P value, e.g. if there are four four-bedroom houses the total P will be 24 P (4 x 6) and the adjusted P will be 22 P (24 x 0.9 = 21.6) • Where the total is 26-50 P multiply the total by 0.8 to give an adjusted P value, e.g. if there are four three-bedroom houses and three four-bedroom houses the total P will be 38 P (4 x 5 and 3 x 6) and the adjusted P Loads & Flows34178 MARSH ENSIGN RANGE 8pp Brochure.indd 5 21/03/2012 16:26Marsh ENsign RangeENSIGN 66 PeopleENSIGN 1010 PeopleENSIGN 1212 PeopleENSIGN 1616 PeopleENSIGN 2020 PeopleFor dimensional sizes refer to page 4 and 534178 MARSH ENSIGN RANGE 8pp Brochure.indd 6 21/03/2012 16:26ENSIGN 2525 PeopleENSIGN 3030 PeopleENSIGN 3535 PeopleENSIGN 4040 PeopleENSIGN 45-5045 People34178 MARSH ENSIGN RANGE 8pp Brochure.indd 7 21/03/2012 16:26sales@marshindustries.co.ukwww.marshindustries.co.ukT.0044 1933 654582F.0044 1933 654583Marsh ENsign RangeSewage Treatment Plants From 6 – 50PESix Person to Fifty PersonHydraulic daily load: 1.2m3/day-10m3/day Material: Virgin Resin & Glass Watertightness (water test): Pass Crushing resistance: Pass Treatment efficiency: BOD: Pass TSS: Pass NH4: Pass Tested to BSEN12566-3: TUV Sud Warranty & Guarantee• The minimum design life of the tank structure is twenty five years. (internally & externally)• The compressor blower is covered by a two year guarantee.• The diffuser is covered by a five year guarantee.• Engineered using high performance materials.• All metal components stainless steel.ENsign 6-50PE RangeUltra Polylok 6PE & 12PEWe able to ofer the Ultra Polylok 6PE & 12PE sewage treatment plants that are also tested to EN12566-3. The units are designed where excavaton is confine and access is limited.The dimensions are: 6PE =1700mm dia. x 2200mm high; 12PE =1700mm dia. x 2500mm highThe unit has the Polylok Filter fted as standard. The compressor is either a 60w Secoh for the 6PE or 100w PE for the 12PE, which is fitted externally. The plant has also been tested for above ground installaton34178 MARSH ENSIGN RANGE 8pp Brochure.indd 8 21/03/2012 16:26
Most popular related searches