TTT Environmental Instruments and Supplies
DustTrak Outdoor Environmental Enclosure 8520 Data sheet
TRUST. SCIENCE. INNOVATION.
DUSTTRAK™ DRX Aerosol Monitor
Models 8533 and 8534
Real-Time Dust Monitoring Takes a Giant Leap Forward
Only the new DUSTTRAK™ DRX Aerosol Monitor can
simultaneously measure both mass and size fraction—no
other monitor can do both. DUSTTRAK DRX monitors are battery-
operated, data-logging, light-scattering laser photometers that
give you real-time aerosol mass readings. They use a sheath
air system that isolates the aerosol in the optics chamber to
keep the optics clean for improved reliability and low
maintenance. Suitable for clean office settings as well as harsh
industrial workplaces, construction and environmental sites and
other outdoor applications. DUSTTRAK DRX monitors measure
aerosol contaminants such as dust, smoke, fumes and mists.
Applications
? Industrial/occupational hygiene surveys
? Indoor air quality investigations
? Outdoor environmental monitoring
? Baseline trending and screening
? Point source monitoring
? Engineering control evaluations
? Engineering studies
? Remote and process monitoring
? Epidemiology studies
? Aerosol research studies
Features and Benefits
? Simultaneously measure size-segregated mass fraction
concentrations corresponding to PM1, PM2.5, Respirable,
PM10, and Total PM size fractions
? Easy to program, easy to operate
? New graphical user interface with color touch-screen
? Perform in-line gravimetric analysis for custom reference
calibrations
? Automatic zeroing (with optional zero module) minimizes the
effect of zero drift
Exposure Mon i to r ing
H E A L T H A N D S A F E T Y
DUSTTRAK DRX Aerosol Monitors Are Light Years
Ahead of Any Other
These new laser photometers simultaneously measure five size-
segregated mass fraction concentrations at once—something no other
monitor can do. Both the desktop and handheld monitors are continuous
real-time 90° light-scattering laser photometers that simultaneously
measure size-segregated mass fraction concentrations corresponding to
PM1, PM2.5, Respirable, PM10, and Total PM fractions. They combine
both particle cloud (total area of scattered light) and single particle
detection to achieve mass fraction measurements.
This size-segregated mass fraction measurement technique is superior to
either a basic photometer or optical particle counter (OPC). It delivers the
mass concentration of a photometer and the size resolution of an OPC.
? Photometers can be used at high mass concentration, but they do
not give any size information (unless used with size selective inlet
conditioners) and significantly underestimate large particle mass
concentrations.
? OPC’s provide size and count information; however, they do not
provide any mass concentration information and cannot be used in
high mass concentration environments.
Easy to Program and Operate
The new graphical user interface with color touch-screen puts
everything at your fingertips. The easy-to-read display shows real-time
mass concentration and graphical data as well as other statistical
information along with instrument pump, laser and flow status, and
much more. Perform quick walk-through surveys or program the
instrument’s advanced logging modes for long-term sampling
investigations. Program start times, total sampling times, logging
intervals, alarm setpoints and many other parameters. You can even set
up the instrument for continuous unattended operation.
Desktop Models: Ideal for Long-Term Surveys and
Remote Monitoring Applications
Manual and programmable data logging functions also make DUSTTRAK
DRX desktop monitors ideal for unattended applications. They come with
USB (device and host), Ethernet, and analog and alarm outputs allowing
remote access to data. User adjustable alarm setpoints for instantaneous
or 15-minute short-term excursion limit (STEL) are available on desktop
models. The alarm output with user-defined setpoint alerts you when
upset or changing conditions occur.
All DUSTTRAK DRX desktop monitors have four unique features:
? Gravimetric sampling capability using a 37-mm filter cassette
which can be inserted in-line with the aerosol stream allowing
you to perform an integral gravimetric analysis for custom
reference calibrations.
? They can be zeroed automatically using the external zeroing module.
This optional accessory is used when sampling over extended periods
of time. By zeroing the monitor during sampling, the effect of zero
drift is minimized.
? STEL alarm feature for tracking 15-minute average mass
concentrations when alarm setpoint has been reached for applications
like monitoring fugitive emissions at hazardous waste sites.
? Standard and advanced calibration capabilities. The DUSTTRAK DRX
Aerosol Monitor has two calibration factors: a photometric calibration
factor (PCF) and a size calibration factor (SCF). The PCF accounts for
the photometric response difference between A1 Test Dust and the
aerosol under measurement, while the SCF accounts for the
aerodynamic size difference.
– The primary goal of the standard calibration is to obtain the SCF
for the aerosol of interest. The standard calibration process is very
easy and does not require comparison to gravimetric samples.
Measure with and without a PM2.5 impactor, and the instrument
takes the ratio of these two size distributions and compares this
reading to the PM2.5 impactor transmission efficiency curve to
calculate the SCF. However, the absolute mass concentration may
not be as accurate as the advanced calibration.
– The advanced calibration method yields high size segregated
mass concentration accuracy. It involves two separate gravimetric
measurements to obtain PCF and SCF in sequence. The advanced
calibration will accurately measure size segregated mass
concentrations.
Handheld Models: Perfect for Walk-Through Surveys
and Single-Point Data Collection Applications
DUSTTRAK DRX handheld models are lightweight and portable. They’re
perfect for industrial hygiene surveys, point source location monitoring,
indoor air quality investigations, engineering control evaluations /
validation, and for baseline trending and screening. Like desktop
models, they have manual and programmable data logging functions. In
addition, they have single-point data logging capability. Single-point data
collection is used for walk-through industrial hygiene surveys and indoor
air quality investigations.
New Software Makes Monitoring Easier than Ever
TRAKPRO™ Data Analysis Software allows you to set up and program
directly from a PC. A new feature is the ability for remote programming
and data acquisition from your PC via wireless (922 MHz or 2.4 GHz)
communications or over an Ethernet network. As always, you can print
graphs, raw data tables and statistical and comprehensive reports for
recordkeeping purposes.
DUSTTRAK DRX Aerosol Monitor Features
All Models
? Li-Ion rechargeable batteries
? Internal and external battery charging capabilities
? Outlet port for isokinetic sampling applications
? User serviceable sheath flow and pump filters
? Logged test pause and restart feature
? Logged test programming
– Color touch screen—either manual mode or program mode
– TRAKPRO™ Data Analysis Software via a PC
? User adjustable standard or advanced custom calibration settings
? Instantaneous alarm settings with visual and audible warnings
? Real-time graph display
? View statistical information during and after sampling
? On-screen instrument status indicators: FLOW, LASER and FILTER
? Filter service indicator for user preventative maintenance
All Desktop Models
? Hot swappable batteries
? Gravimetric reference sample capability
? Long life internal pump
? TRAKPRO Data Analysis Software
? Auto zeroing module (optional accessory)
? STEL alarm setpoint
All Handheld Models
? Long life internal pump
? Single-point data collection for walk through surveys
? TRAKPRO Data Analysis Software
Battery Performance
*of a fully depleted battery
Model 8533 (typical)
6600 mAH Li-Ion Battery Pack (P/N 801680)
1 Battery 2 Batteries
Battery Runtime (hours) up to 6 up to 12
Charge Time * (hours) in DUSTTRAK 4 8
Charge Time* (hours) in external battery charger
(P/N 801685)
4 8
Model 8534 (typical)
3600 mAH Li-Ion Battery Packs (P/N 801681)
Battery
Battery Runtime (hours) up to 6
Charge Time * (hours) in DUSTTRAK 4
Charge Time* (hours) in external battery charger
(P/N 801686)
4
Specifications
Models 8533 and 8534
DUSTTRAK™ DRX Aerosol Monitor
Sensor Type
90° light scattering
Particle Size Range
0.1 to ?15 µm
Aerosol Concentration Range
8533 Desktop 0.001 to 150 mg/m3
8534 Handheld 0.001 to 150 mg/m3
Display
Size Segregated Mass Fractions for PM1, PM2.5, Respirable, PM10 and Total.
All displayed
Resolution
±0.1% of reading or 0.001 mg/m3, whichever is greater
Zero Stability
±0.002 mg/m3 per 24 hours at 10 sec time constant
Flow Rate
3.0 L/min
Flow Accuracy
±5% of factory set point, internal flow controlled
Temperature Coefficient
+0.001 mg/m3 per °C
Operational Temp
32 to 120°F (0 to 50°C)
Storage Temp
-4 to 140°F (-20 to 60°C)
Operational Humidity
0 to 95% RH, non-condensing
Time Constant
User adjustable, 1 to 60 seconds
Data Logging
5 MB of on-board memory (>60,000 data points)
45 days at 1 minute logging interval
Log Interval
User adjustable, 1 second to 1 hour
Physical Size (HWD)
Handheld 4.9 x 4.8 x 12.5 in.
(12.5 x 12.1 x 31.6 cm)
Desktop 5.3 x 8.5 x 8.8 in.
(13.5 x 21.6 x 22.4 cm)
Weight
Handheld 2.9 lb (1.3 kg), 3.3 lb (1.5 kg) with battery
Desktop 3.5 lb (1.6 kg), 4.5 lb (2.0 kg)–1 battery,
5.5 lb (2.5 kg)–2 batteries
Communications
8533 USB (Host and Device) and Ethernet. Stored data
accessible using flash memory drive
8534 USB (Host and Device). Stored data accessible
using flash memory drive
Power–AC
Switching AC power adapter with universal line cord included, 115–240 VAC
Analog Out
8533 User selectable output, 0 to 5 V or 4 to 20 mA
User selectable scaling range
Alarm Out
8533 Relay or audible buzzer
Relay
Non-latching MOSFET switch
User selectable set point
–5% deadband
Connector 4-pin, Mini-DIN connectors
8534 Audible buzzer
Screen
8533 5.7 in. VGA color touchscreen
8534 3.5 in. VGA color touchscreen
Gravimetric Sampling
8533 Removable 37 mm cartridge (user supplied)
CE Rating
Immunity EN61236-1:2006
Emissions EN61236-1:2006
Specifications are subject to change without notice. TSI, the TSI logo, DUSTTRAK, and TRAKPRO are
trademarks of TSI Incorporated. Microsoft and Windows are trademarks of Microsoft Corporation.
Exposure Mon i to r ing
H E A L T H A N D S A F E T Y
TSI Incorporated - 500 Cardigan Road, Shoreview, MN 55126-3996 USA
USA Tel: +1 800 874 2811 E-mail: info@tsi.com Website: www.tsi.com
UK Tel: +44 149 4 459200 E-mail: tsiuk@tsi.com Website: www.tsiinc.co.uk
France Tel: +33 491 11 87 64 E-mail: tsifrance@tsi.com Website: www.tsiinc.fr
Germany Tel: +49 241 523030 E-mail: tsigmbh@tsi.com Website: www.tsiinc.de
India Tel: +91 80 41132470 E-mail: tsi-india@tsi.com
China Tel: +86 10 8251 6588 E-mail: tsibeijing@tsi.com
Singapore Tel: +65 6595 6388 E-mail: tsi-singapore@tsi.com
Contact your local TSI Distributor or visit our website www.tsi.com for more detailed specifications.
P/N 6001981 Rev D Copyright © 2011 by TSI Incorporated Printed in U.S.A.
TRUST. SCIENCE. INNOVATION.
Martha