Dynasonics - TFX Ultra Series - Ultrasonic Flow Meter Brochure

Ultra™CLAMP-ON ULTRASONICFLOW AND ENERGY METERS FOR LIQUIDSUltra ultrasonic fl ow and energy meters clamp onto the outside of pipes and do not contact the internal liquid. The technology has inherent advantages over alternate devices including: low-cost installation, no pressure head loss, no moving parts to maintain or replace, no fl uid compatibility issue, and a large, bi-directional measuring range that ensures reliable readings even at very low and high fl ow rates. Ultra is available in a variety of confi gurations that permit the user to select a meter with features suitable to meet particular application requirements.The Ultra is available in two versions: a stand-alone fl ow meter, and an energy fl ow meter used in conjunction with dual clamp-on RTDs. The energy fl ow meter measures energy usage in BTU, MBTU, MMBTU, Tons, kJ, kW, MW and is ideal for retrofi t, hydronic and other HVAC applications.FEATURES BENEFITS? May be used to measure clean liquids as well as those with small amounts of suspended solids or aeration (e.g., surface water, sewage).? Bi-directional fl ow measurement system. Totalizer options include forward, reverse and net total.? Modbus RTU over RS485 communications; Ethernet connection includes BACNet®/IP, EtherNet/IPTM and Modbus TCP/IP protocols.? Large, easy-to-read digital display.? Rugged, aluminum enclosure ensures a long service life in harsh environments.? Certifi ed for hazardous area installation in North America and Europe.? Reduced material costs: clamp-on sensor eliminates the need for in-line fl anges, pipe fi ttings, strainers, and fi lters.? Reduced installation time: the Ultra may be installed and fully operational within minutes.? Reduced maintenance costs: with no moving parts, there is nothing on the Ultra to wear down – no repair kits or replacement parts are needed.? No need to shut down the process for installation or maintenance due to clamp-on sensor designdynasonics.comMeter with Integral Flow TransducerFor pipe/tubing sizes of 2" (50 mm) and lower, Ultra is available with a clamp-on transducer mounted and wired directly to the fl ow meter display/electronics enclosure. This design provides a convenient installation in areas where the user requires local indication. PVC constructed transducers are rated to 185 °F (85 °C) and CPVC are rated to 250 °F (121 °C).Common Features:• Rate-Total Backlit Display• 4-20mA Output• 0-1,000 Hz Rate Pulse and Dual Alarm Outputs (Flow Meter Model Only)• USB Programming Port• RS485 Modbus Network Connection• Remote Totalizer ResetMeter with Remote Flow TransducerThe Ultra is available with remote mounted transducers that permit separation of up to 990 feet (300 m). This design is utilized when pipes are located in areas that are not convenient for viewing, or on piping systems with severe vibration. PVC constructed transducers are rated to 185 °F (85 °C), CPVC are rated to 250 °F (121 °C) and PTFE are rated to 350 °F (176 °C).Common Features:• Rate-Total Backlit Display• 4-20mA Output• 0-1,000 Hz Rate Pulse and Dual Alarm Outputs (Flow Meter Model Only)• USB Programming Port• RS485 Modbus Network Connection• Remote Totalizer ResetUltraSupplyReturnTemperature Transducers(Energy Meter Only)Integral Flow TransducerBottom ViewFront Viewom ViewBottoomdynasonics.comSupplyReturnRemote Flow TransducersTemperature Transducers (Energy Meters Only)UltraPart Number ConstructionD ? -??? - ???? - ??ModelB) Flow Meter Model Power OptionsE) Energy Meter Model A) A/C (universal 0) None/95-264 VAC) plugged portsPipe Size/Measurement Range D) D/C (11-28 VDC) 1) CableIA) ½" ANSI Pipe (DN 15) C) 24 VAC Gland KitIB) ¾" ANSI Pipe (DN 20)IC) 1" ANSI Pipe (DN 25) Keypad Area ApprovalsID) 1-¼" ANSI Pipe (DN 32) Y) 4-digit Keypad F) Class I Division 2, GroupsIE) 1-½" ANSI Pipe (DN 40) N) None C & D T6; Class 1IF) 2" ANSI Pipe (DN 50) Zone 2 Eex nA IIB T6IG) ½" Copper Tube Advanced Communications (Model DB only)IH) ¾" Copper Tube Y) 10/100 Base-T (EtherNet/IP™, N) None (model DE only)II) 1" Copper Tube BACnet®/IP, Modbus TCP/IP)IJ) 1-¼" Copper Tube T) Total Pulse (Isolated OpenIK) 1-½" Copper Tube Collector Transistor) Energy Temperature RangeIL) 2" Copper Tube N) None N) None (Select for Model DB)IM) ½" OD Standard Tube L) +32 to +122 °F (0 to +50 °C)IN) ¾" OD Standard Tube M) +32 to +212 °F (0 to +100 °C)IP) 1" OD Standard Tube Transducer Material/Temperature H) -40 to +350 °F (-40 to +177 °C)IQ) 1-¼" OD Standard Tube L) PVC, -40 to +185 °F (-40 to +85 °C)IR) 1-½" OD Standard Tube H) CPVC, -40 to +250 °F (-40 to +121 °C)IS) 2" OD Standard Tube N) None (select for Transducer Option RZ)RZ) Remote Mount - use withDTS/DTH/DTL transducersdynasonics.comSpecifi cationsSystemLiquid Types Most clean liquids or liquids containing small amounts of suspended solids or gas bubblesVelocity Range Bi-directional to greater than 40 FPS (12 MPS)Flow Accuracy DTN/DTH/DTL: 1% of reading at rates > 1 FPS (0.3 MPS); ± 0.01 FPS (0.003 MPS) at rates < 1 FPS (0.3 MPS)DTS/DTC: 1" (25 mm) and larger - 1% of reading from 4-40 FPS (1.2-12 MPS); ± 0.04 FPS (0.012 MPS) at rates < 4 FPS (1.2 MPS)DTS/DTC: ¾" (19 mm) and smaller - 1% of Full Scale (refer to Dimensional Specifi cations page)Temperature Accuracy (Energy Meters Only)Option A: +32 to +122 °F (0 to +50 °C); Absolute: 0.22 °F (0.12 °C) Difference: 0.09 °F (0.05 °C)Option B: +32 to +212 ºF (0 to +100 ºC); Absolute: 0.45 ºF (0.25 ºC) Difference: 0.18 °F (0.1 ºC)Option C: -40 to +350 ºF (-40 to +177 ºC); Absolute: 1.1 ºF (0.6 ºC) Difference: 0.45 ºF (0.25 ºC)Option D: -4 to +85 ºF (-20 to +30 ºC); Absolute: 0.22 ºF (0.12 ºC) Difference: 0.09 ºF (0.05 ºC)Sensitivity Flow: 0.001 FPS (0.0003 MPS)Temperature: Option A: 0.03 ºF (0.012 ºC); Option B: 0.05 ºF (0.025 ºC); Option C: 0.1 ºF (0.06 ºC); Option D: 0.03 °F (0.012 ºC)Repeatability 0.5% of readingInstallation ComplianceGeneral Safety (all models): UL 61010-1, CSA C22.2 No. 61010-1; (power options A and D only) EN 61010-1Hazardous Location (power supply options A and D only): Class I Division 2 Groups C, D, T4; Class II, Division 2, Groups F, G,T4; Class III Division 2 for US/CAN; ATEX II 2 G Ex nA II T4: UL 1604, CSA 22.2 No. 213, EN 60079-0 and EN 60079-15CE: EN61326-1:2006 on meter systems with integral fl ow transducers, transducers constructed with twinaxial cable(all transducers with cables 100 ft. (30 m) and shorter) or remote transducers with conduitTransmitterPower Requirements AC: 95-264 VAC 47-63 Hz @ 17 VA max. or 20-28 VAC 47-63 Hz @ 0.35 A max. DC: 10-28 VDC @ 5 W max.Protection: auto resettable fuse, reverse polarity and transient suppressionDisplay Two line LCD, LED backlit; Top row 0.7 inch (18mm) height, 7-segment; Bottom row 0.35 inch (9 mm) height, 14-segmentIcons: RUN, PROGRAM, RELAY1, RELAY2Flow rate indication: 8-digit positive, 7-digit negative max.; auto decimal, lead zero blankingFlow accumulator (totalizer): 8-digit positive, 7-digit negative max. (reset via keypad press, ULTRALINK™, network commandor momentary contact closureEnclosure Type 4 (IP65) Construction: powder-coated aluminum, polycarbonate, stainless steel, polyurethane, nickel-plated steel mounting bracketsSize (electronic enclosure only): 6.0" W x 4.4" H x 2.2" D (152 mm W x 112 mm H x 56 mm D)Conduit Holes: (2) ½" NPT female; (1) ¾" NPT female; Optional Cable Gland KitTemperature -40 °F to +185 °F (-40 °C to +85 °C)Confi guration Via optional keypad or PC running ULTRALINK™ software (Note: not all confi guration parameters are availablefrom the keypad – i.e. fl ow and temperature calibration and advanced fi lter settings)Engineering Units Flow Meter: Feet, gallons, cubic feet, million gallons, barrels (liquid and oil), acre-feet, lbs., meters, cubic meters, liters,million liters, kgEnergy Meter: BTU, MBTU, MMBTU, Tons, kJ, kW, MW and the Flow Meter list from aboveInputs/Outputs USB 2.0: for connection of a PC running ULTRALINK™ confi guration utilityRS485: Modbus RTU command set10/100 Base-T: RJ45, communication via Modbus TCP/IP, EtherNet/IP™ and BACnet®/IP4-20mA: 12-bit, internal power, can span negative to positive fl ow/energy ratesEnergy Meter Model Only: Total Pulse Option: Opto isolated open collector transistorFlow Meter Model Only:0-1,000 Hz: open-collector, 12-bit, can span negative to positive rates; square-wave or turbine meter simulation outputsTwo Alarm Outputs: open-collector, confi gure as rate alarm, signal strength alarm or totalizer pulseTransducersType Compression mode propagation, clamp-onConstruction DTN/DTC/DTL: NEMA 6* (IP67), CPVC, Ultem®, Nylon cord grip, PVC cable jacket; -40 to +250 °F (-40 to +121 °C)DTN/DTL: NEMA 6P* (IP68) option, CPVC, Ultem®, Nylon cord grip, Polyethylene cable jacket; -40 to +250 °F (-40 to +121 °C)DTH: NEMA 6* (IP67), PTFE, Vespel®, Nickel-plated brass cord grip, PFA cable jacket; -40 to +350 °F (-40 to +176 °C)DTS: NEMA 6* (IP67), PVC, Ultem®, Nylon cord grip, PVC cable jacket; -40 to +185 °F (-40 to +85 °C)*NEMA 6 units: to a depth of 3 ft. (1 m) for 30 days max. NEMA 6P units: to a depth of 100 ft. (30 m) seawater equivalent density indefi nitely.Frequency DTS/DTC: 2 MHz DTN/DTH: 1 MHz DTL: 500 KHzCables RG59 Coaxial, 75 ohm or Twinaxial, 78 ohm (optional armored conduit)Cable Length 990 feet (300 meter) max. in 10 ft. (3 m) increments; Submersible Conduit limited to 100 feet (30 m)RTDs Energy Meters Only: Platinum 385, 1,000 ohm, 3-wire; PVC jacket cableInstallation DTN (-N option) /DTS/DTH/DTC: General and Hazardous Location (see Installation Compliance above)DTN Transducer and IS Barrier (-F option): Class I Div. 1, Groups C&D T5 Intrinsically Safe Ex ia;CSA C22.2 No.’s 142 & 157; UL 913 & 916Software UtilitiesULTRALINK™ Utilized to confi gure, calibrate and troubleshoot Flow and Energy meters. Connection via USB A/B cable; software iscompatible with Windows 2000, Windows XP, Windows Vista® and Windows® 7EnergyLink Utilized to monitor a network of Flow and Energy meters. Connection via RS485. Operates within Microsoft Excel® 2003,Microsoft Excel® 2007, Microsoft Excel® 2010. (32-bit O.S. only)UltraUltraNetwork OptionsRS485 NetworkAll meters come equipped with RS485 drivers and utilize a Modbus RTU command set (data can be returned in single-precision, double-precision, integer or fl oating point values). Up to 126 Ultra products can be run on a single daisy-chain network and be individually queried for fl ow rate, positive fl ow accumulator, negative fl ow accumulator, supply temperature, return temperature and signal strength. Flow accumulators can be cleared at discrete addresses or globally. The RS485 network is also compatible with the EnergyLink, direct to Excel®, application detailed below.10/100 Base-T NetworkIf equipped with the optional Ethernet communications module, the Ultra can be plugged into a LAN and queried for fl ow rate, positive fl ow accumulator, negative fl ow accumulator, supply temperature, return temperature and signal strength. The module contains Modbus TCP/IP, EtherNet/IP™ and BACnet®/IP network compatibility.ComplianceGeneral Safety - All Models Hazardous Location Installation - Power Supply A and D onlyClass I Div. 1/Ex iaIntrinsically Safe Location*Class I Div. 2/Ex nA* Intrinsically Safe configuration must contain both the barrier and transducers. Barrier must be within Class I Div. 2/Ex nA or General Safety location.SupplyReturnIntrinsically safe connections Class I, Groups C and D;Class II, Groups E, F, G;Class III, Hazardous locations [ Exia ]“Associated Equipment” Appareillage Connexe”Maximum Safe Area Voltage: 250 VMaximum Voltage: 20V, Maximum Current: 150mAControl Drawing No. D091-1053-005 MODEL: 070-1010-002INTRINSIC SAFETY BARRIERULTRASONICSDivision of Racine Federated, Inc.Racine, WI U.S.A.Tel: 262-639-6770 Fax: 262-639-2267www.dynasonics.comWARNING: Substitution of components may impair intrinsic safety.A VERTISSEMENT: La substitution de composants peut compromettre la Securite Intrinseque. ®c USRS485converterAddress 126Address 2Address 13-wire + shield4,000 feet (1,220 m) max. without repeatersLAN Device N Device 3 Device 2 Device 1UltraDimensional Specifi cationsDTS/DTC Transducer Dimensions: Inches (mm)Pipe SizePipe Material A B C DMeasuring Range½"ANSI/DN 2.46(62.5)2.36(59.9)2.66(67.6)0.84(21.3)2 - 38 GPM8 - 144 LPMCopper 2.46(62.5)2.36(59.9)3.33(84.6)0.63(15.9)1.8 - 27 GPM7 - 102 LPMTubing 2.46(62.5)2.28(57.9)3.72(94.5)0.50(12.7)1.5 - 18 GPM6 - 68 LPM¾"ANSI/DN 2.46(62.5)2.57(65.3)2.66(67.6)1.05(26.7)2.75 - 66 GPM10 - 250 LPMCopper 2.46(62.5)2.50(63.5)3.56(90.4)0.88(22.2)2.5 - 54 GPM10 - 204 LPMTubing 2.46(62.5)2.50(63.5)3.56(90.4)0.75(19.0)2.5 - 45 GPM10 - 170 LPM1"ANSI/DN 2.46(62.5)2.92(74.2)2.86(72.6)1.32(33.4)3.5 - 108 GPM13 - 409 LPMCopper 2.46(62.5)2.87(72.9)3.80(96.5)1.13(28.6)3.5 - 95 GPM13 - 320 LPMTubing 2.46(62.5)2.75(69.9)3.80(96.5)1.00(25.4)3.5 - 85 GPM13 - 320 LPM1-¼"ANSI/DN 2.80(71.0)3.18(80.8)3.14(79.8)1.66(42.2)5 - 186 GPM19 - 704 LPMCopper 2.46(62.5)3.00(76.2)4.04(102.6)1.38(34.9)4.5 - 152 GPM17 - 575 LPMTubing 2.46(62.5)3.00(76.2)4.04(102.6)1.25(31.8)4 - 136 GPM15 - 514 LPM1-½"ANSI/DN 3.02(76.7)3.42(86.9)3.33(84.6)1.90(48.3)6 - 250 GPM23 - 946 LPMCopper 2.71(68.8)2.86(72.6)4.28(108.7)1.63(41.3)5 - 215 GPM19 - 814 LPMTubing 2.71(68.8)3.31(84.1)4.28(108.7)1.50(38.1)5 - 200 GPM19 - 757 LPM2"ANSI/DN 3.70(94.0)3.42(86.9)*5.50(139.7)2.375(60.3)*8 - 420 GPM30 - 1590 LPMCopper 3.70(94.0)3.38(85.9)*5.50(139.7)2.125(54.0)*8 - 375 GPM30 - 1419 LPMTubing 3.21(81.5)3.85(98.0)4.75(120.7)2.00(50.8)8 - 365 GPM30 - 1381 LPM* Varies due to U-bolt confi guration Integral SystemMECHANICAL DIMENSIONS: INCHES (MM)Remote SystemC2.12(53.8)BAD4.32(110)4.20(106.7)2.12(53.8)Pipe mountWall mount6.50(165.1)1.38(35.1)2.30(58.4).19 DIA (4.8)2 Mountingholes2.90(73.7)1.20(30.5)6.00(152.4)DTS/DTC U-Bolt ConnectionsANSI/DN & Copper 2" (50 mm) ModelsDTN/DTH/DTLPipes larger than 2" (50 mm)DTS/DTCPipes/Tubing ½" to 2" (12 mm to 50 mm)DTN 2.95 2.75 3.00 (74.9) (69.8) (76.2)DTH DTL 2.95 2.75 3.00 (74.9) (69.8) (76.2)3.40 2.94 3.20 (86.4) (74.7) (81.3)A B CABC (Min Clearance) BBAD DC A CMechanical Dimensions: Inches (mm)Remote SystemULTEM is a registered trademark of General Electric Co.WINDOWS, EXCEL and VISTA are registered trademarks of Microsoft Corp.CSA is a registered trademark of the Canadian Standards Association.VESPEL is a registered trademark of E. I. du Pont de Nemours and Company.BACNET is a registered trademark of American Society of Heating,Refrigerating and Air-Conditioning Engineers (ASHRAE).UL is a registered trademark of Underwriters Laboratories.
Most popular related searches