Stokvis Energy Systems
  1. Companies & Suppliers
  2. Stokvis Energy Systems
  3. Downloads
  4. Econoplates Sales Literature for E ...

Econoplates Sales Literature for E Series - Brochure

ECONOPLATESThe Ultimate Range of PackagedPlate Heat ExchangersECONOPLATESIn addition the PID control panel on the 'E' series plate heat exchanger also contains: • All functional indicator lamps and LCD display of faults • Control and output fuses • High/ low temperature alarm lamp • Common volt free temperature alarm terminals • High temperature lockout • All control adjustments • A 7 day time clock for either: • 2 temperatures of operation/day • a single temperature and night off/day • Duplex pump duty sharing• External control circuit for 2 temperates or 1 temperature and off • External interlock circuit • 4-20mA temperature output signalOn the E4B and E3C models primary pump overloads are also included as standard with auto change over on units fitted with duplex primary pumps. Volt free pump run or fault indication is available as an option.The Stokvis Econoplate packages can thus be accommodated into most BMS systems via volt free contacts for external high/low temperature alarms the external control circuits etc. and optional primary pump run and trip indication.In effect, the Econoplate units provide an effective, efficient, versatile system for the controlled delivery of hot water over an unbelievable range of demand requirements. A complete system which is easy to install, operate and maintain; which is fast and effective in response, tried and tested in operation and with none of the unhealthy drawbacks of a storage system either practical or medicalThe Stokvis Econoplate packaged Plate Heat Exchanger units are available in up to seven ranges covering some 200 plus units fulfilling a tremendous variety of applications. From simple domestic hot water generation to swimming pool heating or even complex process heating and beyond, Stokvis have a unit and the expertise which would satisfy your demands.Stokvis Econoplates are designed to provide hot water instantaneously, from zero output up to their maximum rated output, without the need for hot water storage.The principle is simple, well proven and extremely cost effective. All of the Econoplate units are built around an epoxy coated chassis which contains the heat exchanger. This heat exchanger is constructed from a number of gasketed, stainless steel plates - easily increased should demand require.Their low water content and low thermal inertia make them ideal for use in systems with rapidly changing heat outputs.The Econoplate uni ts, wi th the exception of bare plate units, come as required with either primary pump(s), and/or 2, 3 or 4-port motorised control valve on the primary circuit, and purpose build PID controller for sensing secondary water temperature and controlling the motorised valve.ECONOPLATE E4B package equipped with 316 grade stainless steel plates. This range will satisfy demands from 68 to 395 apartments, or 43 to 228 hotel rooms. Available hot water flow is from 115 to 255 l/min at a temperature of 10 to 60 degC, depending on primary circuit temperature and heat exchange surface of the unit.ECONOPLATE E4A SERIES ECONOPLATE E4B SERIESECONOPLATE E4A package equipped with 316 grade stainless steel plates. This range will satisfy demands from 2 to 67 apartments, or 3 to 44 hotel rooms. Available hot water flow is from 13 to 92 l/min at a temperature of 10 to 60 degC, depending on primary circuit temperature and heat exchange surface of the unit.E4A SERIES E4B SERIESE4B23E4B27E4B31E4B35E4B39E4B43E4B47E4B51E4B55E4B59115.2135.0153.6171.6187.8204.0217.2231.6243.6255.02.863.273.623.974.264.554.785.005.175.33401470535598654710756806848888Econoplate 'E4B' Series Plate Heat Exchanger PackagesTYPEE4BSEC. FLOW RATE 10-60O C (l/min)at 40 kPaResistancePRIMARY FLOW RATE l/sec.@ 82O CHEAT LOAD kWEconoplate 'E4A' Series Plate Heat Exchanger PackagesSEC. FLOW RATE 10-60O C (l/min)at 25 kPaResistancePRIMARY FLOW RATE l/sec.@ 82O CHEAT LOAD kWE4A5E4A7E4A9E4A11E4A13E4A15E4A17E4A19E4A21E4A23E4A25E4A2712.923.031.940.848.956.664.070.176.781.687.391.90.470.670.831.001.141.281.421.501.601.671.751.804580111142170197223244267284304320TYPEE4AECONOPLATE E3C package equipped with 316 grade stainless steel plates. This range will satisfy demands from 135 to 623 apartments, or 75 to 351 hotel rooms. Available hot water flow is from 163 to 332 l/min at a temperature of 10 to 60 degC, depending on primary circuit temperature and heat exchange surface of the unit.ECONOPLATE E0B Econoplate swimming pool package comes complete with primary circuit pump, electronic temperature control and primary non-return valve - no motorised valve is used in this application. EOB Econoplate units are suitable for all types of pools: public, private or medical. Special titanium plates are available for sea water applications.ECONOPLATE E3C SERIES ECONOPLATE E0B SERIESE3C SERIES E0B SERIESTYPEE0BPRIMARY FLOW RATE l/sec.@ 82O CEconoplate E0B Plate Heat Exchanger Packages.POOL WATER FLOW RATE l/sec.NOMINAL OUTPUT kWE0B5E0B7E0B9E0B11E0B13E0B15E0B17E0B19E0B21E0B23E0B250.450.670.891.101.331.541.751.962.162.362.550.771.061.281.471.641.771.871.982.072.172.224880109137164188211233253274291Econoplate 'E3C' Plate Heat Exchanger PackagesE3C22E3C26E3C30E3C34E3C38E3C42E3C46E3C50E3C54E3C58E3C62E3C66E3C70163.2186.0207.6228.6244.8259.8273.0286.8295.8307.8317.4325.2332.43.954.354.705.055.255.455.605.795.856.006.106.156.20568649724797852905951100010311072110611321157TYPEE3CSEC. FLOW RATE 10-60O C (l/min) at 30 kPa RestistancePRIMARY FLOW RATE l/sec.@ 82O CHEAT LOAD kW ECONOPLATE ‘BARE PLATE’ : The units listed below are a sample of some 36 models which are available with infinite variations on plate numbers, plate types, and gasket materials. Whilst water heat exchange is the prime objective, many other fluids can be catered for with ease. Stokvis are more than willing to help solve your heat exchange problems; sophisticated computerised sizing and load/fluid requirement calculations ensure effective solutions.Contact Stokvis for more information.ECONOPLATE STEAM TO WATER packages are also available in several unit sizes, as indicated below, giving even greater flexibility of application. This package comes complete with two port motorised valve together with electronic control panel. For hot water service applications, as with other Econoplate units, a secondary re-circulating pump and non return valve can be fitted as an option. The steam to water packages can also be used for low temperature heating systems.ECONOPLATE BARE PLATE SERIESECONOPLATE E2 SW SERIESBARE PLATEE2 SW SERIESEconoplate Steam to Water Plate Heat Exchanger packages.TYPE E2A SW E2B SWE2C SWSEC. FLOW RATE 10-60O C (l/min) 30 kPa ResistancePRIMARY FLOW RATE Kg/Sec.@ 130O CHEAT LOAD kW.E2A(SW)5E2A(SW)9E2A(SW)13E2A(SW)15E2A(SW)19E2A(SW)23E2A(SW)25E2B(SW)27E2B(SW)31E2C(SW)20LE2C(SW)24LE2C(SW)28LE2C(SW)32LE2C(SW)36L14.328.743.057.472.085.8100.0114.6129.0144.0172.0201.0230.0258.00.0230.0460.0690.0920.1150.1380.1610.1840.2070.2300.2760.3220.3690.41550100150200250300350400450500600700800900Econoplate Bare Plate heat ExchangersType AmmBmmCmmDmmEmmL (max)mmMax. Flow Rate (m3/h)M4M10GC12GC28GC30GX12GX18GX26GX42GX51GX64GX91GX118GX60GX851882874807896758301060126616751730190523852865160519107211518017524032032046046062062062062083010601542433576755555928227791188114313201800228091011404072606510013513522622630028528528542057017226271601401402212213003003003003503601402053358485564004002770277028002800280028003600370041220123050502002004504504504508001800EPLT-0612STOKVIS INDUSTRIAL BOILERS(INTERNATIONAL) LIMITED96R Walton Road East Molesey Surrey KT8 0DLTELEPHONE 020 8783 3050 • FACSIMILE 020 8783 3051Email: info@stokvisboilers.com • Website: http://www.stokvisboilers.com
Most popular related searches