General Electric
Electrodialysis Reversal Fact Sheet
Fact Sheet Find a contact near you by visiting www.gewater.com and clicking on “Contact Us”. * Trademark of General Electric Company; may be registered in one or more countries. ©2013, General Electric Company. All rights reserved. FS1242EN.doc Jul-13 GE 2020 EDR Systems Electrodialysis Reversal Technology The GE 2020 Electrodialysis Reversal (EDR) product is a proven and reliable desalination technology that has been in service in a variety of industrial and public infrastructure applications. EDR Features ? Use of Carbon Electrodes results in no gas pro-duced and no separate electrode stream required. ? High Water Recovery, up to 94% ? Salt Removal of 50 to 95% ? Polarity Reversal self-cleaning with electricity ? Free chlorine tolerance ? Tolerance to moderate suspended solids ? Adjustable product water performance without blending ? Ability to disassemble stacks for inspection ? Silica tolerance EDR Benefits ? Efficient use of scarce water resources ? Low pretreatment requirements and costs ? Low chemical consumption costs ? Long membrane life, typically 10+ years ? Strong ability to recover from less than ideal feed water quality Standard Design and Scope of Supply ? MK-IV-2 EDR stacks with GE Carbon Electrodes ? Cartridge filter ? Concentrate Recirculation pump with VFD ? GE Fanuc Micro PLC & 12” (30 cm) color Quick Panel HMI ? Full Owners Operation & Maintenance Manual, Factory Acceptance Test results and Stack Per-formance Test results Instrumentation - Transmitters Flow ............................ Product Outlet, Concentrate Outlet Pressure ................................ Cartridge Filter Inlet & Outlet Concentrate, Recirculation Pump Outlet, Product Outlet Conductivity ....................................... Inlet & Product Outlet Operating Parameters Water Recovery ....................................................... Up to 94% Salt Removal .......................................................... 50% to 95% Silica Removal ...................................................................... none Temperature ................................... 40 to 100ºF (4 To 38ºC) Maximum Feed Pressure .............................................. 50 psi Input Voltage ................................................. 480VAC/3/60Hz Feed Water Requirements Typical Feed TDS ........................ 100 to 3,000 ppm (mg/l) Maximum Feed TDS ............................. 12,000 ppm (mg/l) Silica (Reactive) .......................................................... unlimited pH .......................................................................................... 2 to 10 SDI (5 min. test) ........................................................................ 10 Turbidity ....................................................................... < 0.5 NTU Free Chlorine (continuous) ........................ 0.5 ppm (mg/l) Page 2 FS1242EN TOC ..................................................................... < 15 ppm (mg/l) COD ....................................................... < 50 ppm (mg/l) as O2 Iron .................................................................... < 0.3 ppm (mg/l) Manganese, Aluminum ........................... < 0.1 ppm (mg/l) H2S .................................................................... < 0.1 ppm (mg/l) Allowable Intermittent Levels: SDI (5 min. test) ......................................................................... 15 Turbidity ............................................................................2.0 NTU Free Chlorine .................................................................. 30 mg/l Material of Construction Welded Frame................................... Painted Carbon Steel Dilute and Concentrate Piping ...................... Sch. 80 PVC Flanges .................................................................................... ANSI Concentrate Pump ................... Single-stage Centrifugal Rectifier ......................................................................... NEMA 3R Control Panel ................................................................. NEMA 4 Quality Assurance Certification ............................................................................... UL Facility ................................................................. ISO 9001:2000 EDR 2020 2 & 4 Line Standard Systems MODEL 2020-2L-2S 2020-2L-3S 2020-4L-2S 2020-4L-3S Flow Rates Product Flow Nominal 280 gpm 63.6 m3/h 260 gpm 59.1 m3/h 560 gpm 127.2 m3/h 520 gpm 118.2 m3/h Product Flow Range 165 to 325 gpm 37.5 to 73.8 m3/h 165 to 270 gpm 37.5 to 61.3 m3/h 325 to 655 gpm 73.8 to 148.8 m3/h 325 to 545 gpm 73.8 to 123.8 m3/h Concentrate Outlet Flow Depends on recovery and product Electrode Outlet Flow 2.2 gpm 8.3 lpm 2.5 gpm 9.5 lpm 4.3 gpm 16.3 lpm 5.0 gpm 19 lpm General Information Number of Stacks 4 6 8 12 Number of Lines 2 2 4 4 Number of Stages 2 3 2 3 Type of Stack MK-IV-2 MK-IV-2 MK-IV-2 MK-IV-2 Dimensions System Dimensions Width x Length 90” x 309” (2.3 x 7.9 m) 90” x 375” (2.3 x 9.5 m) 169” x 493” (4.3 x 12.5 m) 169” x 625” (4.3 x 15.9 m) Inlet Piping 4” (10 cm) 4” (10 cm) 6” (15 cm) 6” (15 cm) Product Outlet Piping 4” (10 cm) 4” (10 cm) 6” (15 cm) 6” (15 cm) Off-Spec Outlet Piping 4” (10 cm) 4” (10 cm) 6” (15 cm) 6” (15 cm) Electrode Outlet Piping 3” (8 cm) 3” (8 cm) 3” (8 cm) 3” (8 cm) Concentrate Outlet Piping 1.5” (4 cm) 1.5” (4 cm) 2” (5 cm) 2” (5 CM) Note: all piping sizes are provided for nominal flow rates at 85% recovery. Electrical Maximum Rectifier Output (Per Stack Basis) Stage 1 590VDC, 46A 590VDC, 26A 590VDC, 46A 590VDC, 26A Stage 2 518VDC, 18A 518VDC, 14A 518VDC 18A 518VDC, 14A Stage 3 420VDC, 7.5A 420VDC, 7.5A Connection Requirement (Includes Feed pump, which may be supplied by others) 140 KVA 107 KVA 276 KVA 209 KVA Typical Power consumption 2 – 4 kWh/1,000 gallons of product water Performance, number of stages and cell pairs, recovery and power consumption are dependent on inlet feed water quality and temperature. A Watsys projection must be completed by an authorized GE Water & Process Technologies design representative for proper system design & for any performance guarantee to be provided. FS1242EN Page 3 EDR 2020 6 & 8 Line Standard Systems MODEL 2020-6L-2S 2020-6L-3S 2020-8L-2S 2020-8L-3S Flow Rates Product Flow Nominal 840 gpm 190.8 m3/h 780 gpm 177.2 m3/h 1120 gpm 254.4 m3/h 1040 gpm 236.2 m3/h Product Flow Range 485 to 985 gpm 110.2 to 223.7 m3/h 485 to 820 gpm 110.2 to 186.2 m3/h 645 to 1315 gpm 146.5 to 298.7 m3/h 645 to 1090 gpm 146.5 to 247.6 m3/h Concentrate Outlet Flow Depends on recovery and product flow rate Electrode Outlet Flow 6.5 gpm 25 lpm 7.5 gpm 28 lpm 8.7 gpm 33 lpm 10 gpm 38 lpm General Information Number of Stacks 12 18 16 24 Number of Lines 6 6 8 8 Number of Stages 2 3 2 3 Type of Stack MK-IV-2 MK-IV-2 MK-IV-2 MK-IV-2 Dimensions System Dimensions Width x Length 270” x 493” (6.0 x 12.5 m) 270” x 625” (6.0 x 15.9 m) 270” x 493” (6.0 x 12.5 m) 270” x 625” (6.0 x 15.9 m) Inlet Piping1 8” (20 cm) 8” (20 cm) 8” (20 cm) 8” (20 cm) Product Outlet Piping 8” (20 cm) 8” (20 cm) 8” (20 cm) 8” (20 cm) Off-Spec Outlet Piping 8” (20 cm) 8” (20 cm) 8” (20 cm) 8” (20 cm) Electrode Outlet Piping 3” (8 cm) 3” (8 cm) 3” (8 cm) 3” (8 cm) Concentrate Outlet Piping 3” (8 cm) 3” (8 cm) 3” (8 cm) 3” (8 cm) Note: all piping sizes are provided for nominal flow rates at 85% recovery. Electrical Maximum Rectifier Output (Per Stack Basis) Stage 1 590VDC, 46A 590VDC, 26A 590VDC, 46A 590VDC, 26A Stage 2 518VDC, 18A 518VDC, 14A 518VDC 18A 518VDC, 14A Stage 3 420VDC, 7.5A 420VDC, 7.5A Connection Requirement (Includes Feed pump, which may be supplied by others) 380 KVA 285 KVA 542 KVA 397 KVA Typical Power consumption 2 – 4 kWh/1,000 gallons of product water Performance, number of stages and cell pairs, recovery and power consumption are dependent on inlet feed water quality and temperature. A Watsys projection must be completed by an authorized GE Water & Process Technologies design representative for proper system design & for any performance guarantee to be provided.
Most popular related searches
