Power Plant Supply Co
  1. Companies & Suppliers
  2. Power Plant Supply Co
  3. Downloads
  4. Engineering Manual Canada Dist Power ...

Engineering Manual Canada Dist Power Plant Supply- Brochure

Link-Seal® Modular SealsCentury-Line® SleevesCell-Cast® DisksUse the original engineered fit for pipes passingthrough walls, floors and ceilings...there are no performing equalsMade in U.S.A.A.R.R.A. CompliantEngineering ManualCanada Dist Power Plant SupplyProduct enhancements andsizing charts updated 2-11 mailto:sales@powerplantsupplyco.com http://www.powercanadasolutions.com/linkseal.html IN CANADA CONTACT CANADIAN DIST POWER PLANT SUPPLY CO mailto:sales@powerplantsupplyco.com Table of ContentsCAD Drawings - SubmittalsLink-Seal® Modular SealsThe System is the Solution . . . . . . . . . . . . . . . . . . .3Technical Approvals . . . . . . . . . . . . . . . . . . . . . . . .3Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4Model Options - Material Properties . . . . . . . . . . . .5Dimensional Data . . . . . . . . . . . . . . . . . . . . . . . . . .6Link-Seal® Sizing Method (Updated) . . . . . . . . . . . .7Sizing Procedure - Method 1 . . . . . . . . . . . . . . . . .8-11Sizing Procedure - Method 2 . . . . . . . . . . . . . . . . .12Suggested O.D. Pipe Ranges . . . . . . . . . . . . . . . .12Sizing Procedure - Method 2 (Verification) . . . . . . .13-14Century-Line® Sleeves Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15Weights and Dimensional Data . . . . . . . . . . . . . . .15Cell-Cast® DisksFeatures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16Weights and Dimensional Data . . . . . . . . . . . . . . .16Type WS Steel Wall SleevesWeights Dimensional Data and Specification . . . . .17Technical/EngineeringLink-Seal® Modular Seal Bolt Test Results . . . . . . .17Link-Seal Modular Seals- Specialty ApplicationsSteel Pipe Reference Schedules . . . . . . . . . . . . . .18Fire Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19Sealing Pipeline Casings . . . . . . . . . . . . . . . . . . . .20Sealing An Oversize Annulus . . . . . . . . . . . . . . . . .21Pressure Testing . . . . . . . . . . . . . . . . . . . . . . . . . . .21Sealing Manhole Penetrations . . . . . . . . . . . . . . . .21Installation TechniquesLink-Seal® Modular Seal Installation . . . . . . . . . . . .22Century-Line® Sleeve Installation . . . . . . . . . . . . . .23Cell-Cast® Disk Installation . . . . . . . . . . . . . . . . . . .24Product Ordering Code . . . . . . . . . . . . . . . . . . . . . . . . .25Typical Specification . . . . . . . . . . . . . . . . . . . . . . . . . . .26Frequently Asked Questions . . . . . . . . . . . . . . . . . . . . .27Warranty and Conditions of Sale . . . . . . . . . . . . . . . . . .28Updated engineering catalogs, literature, CAD Drawings,submittals and installation techniques are available on-lineat: www.linkseal.comPerformance data included in this manual is intended forguideline purposes only. Performance suitability for anyspecific application should be determined by the user.Variation in temperature, pressure, concentration or mix-tures acting synergistically may preclude recommendedservice use.2CAD drawings (.dwg) are available on-line. Drawings can be download and inserted into AutoCAD for drawing plans. Submittalsheets can also be accessed in a PDF file. Contact PSI or your local authorized distributor for support and purchasing information.Note: The Link-Seal® sizing charts in printed issues LSEM/10-04, PSI-LSCLCC-2/05 and LSEM/8-06 are still valid fits for field applications.It’s suggested you use the latest updated provided sizing.The System is the Solution.Link-Seal® Modular Seals...The best way to permanently seal any cylindrical object, of any size, passing through any typeof concrete barrier?(wall, floor or ceiling) is to use Link-Seal® modular seals. From ductile iron topre-stressed concrete to metal or plastic pipe, conduit or cables - whatever your application -Link-Seal® modular seals will effect a hydrostatic seal capable of holding 20 psig (40 feet ofstatic head) between the pipe and the penetration cylinder through which the pipe passes.in combination with Century-Line® sleeves... The best way to guarantee a perfect seal is to use Century-Line® sleeves with Link-Seal®modular seals. They’re engineered and sized to provide a stable hole that matches dimension-ally with Link-Seal® modular seals. It makes ordering quick and easy and guarantees a perfectfit - and seal - each and every time.or Cell-Cast® disks.For larger holes in poured concrete structures, (29.25” to64.75”Ø) Cell-Cast® disks are used to produce a dimensionallystable hole and smooth concrete surface that is perfect for usewith Link-Seal® modular seals.Link-Seal® Modular Seal Technical ApprovalsThe following is a partial listing of the many Federalagencies, associations, code groups, laboratories andorganizations which have approved, listed, specified,tested or otherwise indicated acceptance of Link-Seal®modular seals. General Code Groups, Associations, Laboratoriesand Approval AuthoritiesAWWA - American Water Works AssociationAPI - American Petroleum InstituteTÜV - Technischer Überwachungs-VereinBureau Veritas - Marine DivisionASME - American Society of Mechanical EngineersDNV - Det Norske VeritasFM - Factory Mutual Engineering CorporationLLOYD’S - Lloyd’s Register of ShippingNACE - National Association of Corrosion EngineersGovernmental AgenciesBureau of Public Roads - Division of BridgesUnited States Coast GuardCorps. of EngineersGSA - General Services AdministrationMilitary SpecificationsTVA - Tennessee Valley AuthorityARRA- American Recovery Reinvestment ActLink-Seal® Modular Seal Applications• Mechanical Contractors - Interior Piping Systems • Manhole Pipe Entry Seals • Waste Treatment Plants • Cased Road Crossings • Thermal Storage Systems • Fire Protection Wall Penetrations • Cased Railroad Crossings • Electrical Isolation of Pipes • Precast Concrete Vault Seals • Insulated Pipe Seals • Dual Containment Seals • Marine Applications • Noise Dampening• Flexible Sign & Pole Supports • Electrical Isolation of Pipe Supports • Mining • Pulp & Paper • Decorative Fountains • Pool Contractors • Electrical Contractors • Waste & Water Treatment • Telecommunications • Valve Pits • Refrigeration Buildings • Guard Post Assemblies • Power Generation Dams • Offshore Oil Rigs • High Pressure Tank Guards • Underground Steel Tanks • Precast Concrete Manufacturers • Perimeter Berm Installations Around Tank Farms • Flow Restrictors in Sewer Maintenance • Fluid Overflow Devices • Noise and Sway Dampener • Through Deck Fire Breaks • Bridge Construction • Septic Tank Installations • Coal Preparation Plants • Tunneling Operations3Saves time and money...Link-Seal® modular seals install in up to 75% less time whencompared to lead-oakum joints, handfitted flashings, mastics or casing boots.Positive hydrostatic seal...Link-Seal® modular seals are rated at20 psig (40 feet of head), whichexceeds the performance requirementsof most applications.Long seal life...Link-Seal® modular seals are designedfor use as a permanent seal. Seal ele-ments are specially compounded toresist aging and attack from ozone,sunlight, water and a wide rangeof chemicals.Maximum protection against corFasteners employ the use of a propri-etary coating process on carbon steel.For extremely corrosive environments, corrosion resistant 316stainless steel hardware is offered as a standard.Link-Seal® Modular Seal FeaturesISO Quality Assurance...Link-Seal® modular seals are manufactured in an ISO9001:2008 certified facility. In addition, they are completely man-ufactured and assembled in the U.S.A.Certification/Approvals...Factory Mutual Approval.Det Norske Veritas Marine Deak/BulkheadPenetration Certification.Also a wide variety of approvals from variousFederal agencies, associations, code groups, labora-tories and organizations.Configure a Link-Seal® modular seal tomatch your application...Color coded EPDM, Nitrile, & Silicone elastomersmay be used with various hardware options to matchperformance characteristics with service conditions.Choose a Link-Seal® modular seal to matchyour pipe size and wall opening...Link-Seal® modular seals are now available in 16sizes to provide a solution for varying pipe penetration applica-tions.4Steel and Plastic Pipe with Same Outside DiameterCS MODEL NON-METALLIC SLEEVE WS MODEL STEEL SLEEVE CAST OR CORE BIT DRILLED HOLEPIPE ACTUALSIZE O.D. MODEL LINK-SEAL® LINKS MODEL LINK-SEAL® LINKS HOLE LINK-SEAL® LINKS(Nom.) (Inches) NUMBER SIZE PER SEAL NUMBER SIZE PER SEAL I.D. SIZE PER SEAL3 3.500 CS-5-* LS-300-*** 8 WS-5-25-S-* LS-300-*** 8 5.000 LS-300-*** 83 3.500 CS-5-* LS-300-*** 8 WS-6-28-S-* LS-360-*** 7 5.000 LS-300-*** 810 10.750 CS-14-* LS-400-*** 10 WS-14-37-S-* LS-425-*** 10 14.000 LS-400-*** 1010 10.750 CS-14-* LS-410-*** 15 WS-14-37-S-* LS-425-*** 10 14.000 LS-475-*** 1416 16.000 CS-20-* LS-400-*** 15 WS-20-37-S-* LS-400-*** 15 20.000 LS-575-*** 1816 16.000 CS-20-* LS-410-*** 21 WS-20-37-S-* LS-475-*** 21 20.000 LS-575-*** 18Link-Seal® Sizing MethodPipeline Seal & Insulator, Inc. has re-evaluated the Link-Seal® modular seal standard sizing for the sizing charts that are included inthis Engineering Manual and our Selection Guide. The updated Link-Seal® sizing method puts the most rubber in the hole. Pleasesee the graphic, listed features, and sizing chart examples below for a complete understanding of the Link-Seal® sizing method.This updated method benefits the engineer, owner and contractor. Features: More Rubber in Annular Space = Better Performing Seal• Improved engineered fit.• Improved vibration dampening.• Minimum loads on bolts and pressure plates with same sealing effect.• Most sealing pressure/most volume of sealing element in penetration.• Curvature of link sized to penetration O.D. and I.D. for smooth fit.In accomplishing putting more rubber in the annular space, the Link-Seal® assem-bly may require a larger size link with less links per belt or a smaller size link withmore links per belt. Sleeve and cored hole sizing has also been taken into consid-eration. The charts below show examples comparing previous chart selectionsand the updated chart selections.Compare: Solutions in Bolded Blue = Updated Link-Seal® Sizing Method. Link-Seal® Sizing Alternatives Example: A Ductile Iron Pipe 16” Cored Hole Ductile Link-Seal® Cored HoleIron Size, # Links SizeDI 16” LS-340-***-37 20” Cored HoleDI 16” LS-360-***-27 20” Cored HoleDI 16” LS-425-***-16 20” Cored HoleDI 16” LS-500-***-16 22” Cored HoleDI 16” LS-525-***-16 22” Cored HoleDI 16” LS-575-***-19 22” Cored HoleDI 16” LS-600-***-10 24” Cored HoleExperience Counts....There are a lot of sizing solutions for a particularapplication. (See 16” D.I. Pipe Example) For the best/improved solution for either existing or new penetrations, letour vast network of experienced personnel assist you in correctly sizingthe best solution using one of the 16 unique sizes of links availablein 4 sealing elements. If your application is not in the providedcharts; use Method 2 sizing, contact PSI or an authorized Link-Seal® distributor.Sleeve/HoleAnnular SpacePipeImprovedPreviousLink-Seal® Modular Seal Model PropertiesModel “C” or “L” Link-Seal Modular SealSuitable for use in water, direct ground burial andatmospheric conditions. Provides electrical isolationwhere cathodic protection is required.Type: StandardSeal Element: EPDM (Black) or EPDM (Blue)Pressure Plates: Reinforced Nylon PolymerBolts & Nuts: Steel with 2-part Zinc Dichromate &proprietary corrosion inhibiting coating. Temp. Range: -40 to +250ºF (-40 to +121ºC)*Model “S-316” or “LS-316 Link-SealModular Seal For chemical processing &waste water treatment. EPDM rubber is resist-ant to most inorganic acids and alkalis, someorganic chemicals (acetone, alcohol, ketones).Type: StainlessSeal Element: EPDM (Black) or EPDM (Blue)Pressure Plates: Reinforced Nylon PolymerBolts & Nuts: 316 Stainless SteelTemp. Range: -40 to +250ºF (-40 to +121ºC)*Model “O” Link-Seal Modular SealNitrile rubber is resistant to oils, fuel and manysolvents (gasoline, motor oil, kerosene, methane,jet fuel, hydraulic fluid, water, etc.).Type: Oil ResistantSeal Element: Nitrile (Green) Note: Not U.V resistant.Pressure Plates: Reinforced Nylon PolymerBolts & Nuts: Steel with 2-part Zinc Dichromate& proprietary corrosion inhibiting coating.Temp. Range: -40 to +210ºF (-40 to +99ºC)*Model “OS-316” Link-Seal Modular SealCombination of oil resistant rubber andstainless steel hardware.Type: Oil ResistantSeal Element: Nitrile (Green) Note: Not U.V resistant.Pressure Plates: Reinforced Nylon PolymerBolts & Nuts: 316 Stainless SteelTemp. Range: -40 to +210 ºF (-40 to +99ºC)*Model “T” Link-Seal Modular SealSilicone rubber is ideal for temperatureextremes. The “T” model is one-hour FactoryMutual approved.Type: High/Low TemperatureSeal Element: Silicone (Grey)Pressure Plates: Steel Zinc DichromateBolts: Steel with 2-part Zinc Dichromate &proprietary corrosion inhibiting coating.Temp. Range: -67 to +400ºF (-55 to +204ºC)*Model “FD/FS” Link-Seal Modular SealDouble seal for added protection.Type: Fire SealsSeal Element: Silicone (Grey)Pressure Plates: Steel zinc dichromateBolts: Steel with 2-part Zinc Dichromateproprietary corrosion inhibiting coating.Temp. Range: -67 to +400ºF (-55 to +204ºC)*with EPDM Seal Elementswith Nitrile Seal Elementswith Silicone Seal ElementsNOTE: Sustains a constant temp. of 325ºF. (163º C.)* = Sustained operation near temperature limits may affect life expectancy.EPDM (Black)EPDM (Blue) Low DurometerNitrile (Green)Silicone (Grey)* = Sustained operation near temperature limits may affect life expectancy.* = Sustained operation near temperature limits may affect life expectancy.5Model “S61” Link-Seal Modular SealNSF 61 Certified for use in potable water(drinking water). Type: Stainless Seal Element: EPDM (Black)Pressure Plates: Blue Reinforced Nylon PolymerBolts & Nuts: 316 Stainless Steel. Temp. Range: -40 to +250ºF (-40 to +121ºC)*EPDM (Black)* = Sustained operation near temperature limits may affect life expectancy.NSF?Certifiedmailto:sales@powerplantsupplyco.com http://www.powercanadasolutions.com/linkseal.html 6Bolt & Nut SpecificationsStandard: Carbon SteelCarbon steel, zinc dichromated per ASTM B633, with anadditional corrosion inhibiting proprietary organic coating.(passes 1470 hour salt spray test)Tensile Strength = 60,000 psi, minimum.An independent 1,470 hour salt spray test run inaccordance to ASTM B117-97 has proven Link-Seal®modular seals’ Zinc Dichromated Carbon Steel bolts,with proprietary corrosion inhibiting coating, to besuperior when compared with competitive manufactures. Test CriteriaBolts subject to exposure in Salt Spray Cabinet for1,470 hours according to ASTM B117-97.The Link-Seal® Zinc Dichromated Carbon Steel boltwith proprietary corrosion inhibiting coating will pro-vide greater resistance to the most hostile environ-mental conditions on earth.Option: Stainless SteelANSI Type = 316, Per ASTMF593-95Tensile Strength = 85,000 psi,average.Material Properties of Link-Seal Modular Seal ElementsASTMPROPERTY METHOD EPDM (EPDM L) NITRILE SILICONEHardness (shore A) D-2240 50 ±5 (40 ±5) 50 ±5 50 ±5Tensile D-412 1450 psi 1300 psi 860 psiElongation D-412 400% 300% 250%Compression Set S-395 15% 45% 40%22 hrs. @ 158ºF (70ºC) 22 hrs. @ 212ºF (100ºC) 22 hrs. @ 350ºF (177ºC)Specific Gravity D-297 1.10 1.15 1.40Material Properties of Composite Pressure PlatesASTMPROPERTY METHOD VALUEIzod Impact - Notched D-256 2.05 ft-lb/inTensile Strength @ Yield D-638 20,000 psiTensile Strength - Break D-638 20,250 psiFlexural Strength @ Yield D-790 30,750 psiFlexural Modulus D-790 1,124,000 psiElongation, Break D-638 11.07%Specific Gravity D-792 1.38Moisture Content -- 0.18%1,470 hour salt spray test per-formed by an independent lab-oratory. Test results are avail-able on request. Link-Seal® Modular Seal Model PropertiesIndependent Laboratory TestThe Newly Engineered ForceDispersion Pressure Plateshave been fully tested by anindependent laboratory toensure design theory translatesinto the capability to handle therigors of real world applications.In addition, the new design hasan average of 15% morestrength than previous Link-Seal® Modular Seal versions.To provide consistency andworldwide compatibility, PSI nowoffers all Link-Seal® ModularSeal sizes with metric bolts. Thenew bolts adhere to metric spec-ifications as used by most allcountries outside the U.S.A.Smaller Link-Seal® ModularSeals (sizes LS-200, LS-275,LS-300, and LS-315) will consistof metric Allen head or socketcap bolt heads while the balanceof the line will use standard hexhead metric bolts. Link-Seal® Model Tool Size/Type Req. Bolt Head TypeLS-200, LS-275 4mm, AllenLS-300, LS-315 6mm, AllenLS-325, LS-340, LS-360 13mm, HexLS-400, LS-410, LS-425, LS-475 17mm, HexLS-500, LS-525, LS-575 19mm, HexLS-600 30mm, HexLS-650 19mm, Hex7*Dimensional Data for Models C, L, O, S-316, S61, LS-316 and OS-316RUBBER SEALING ELEMENT PRESSURE PLATE BOLTACTUAL FREE AVG. LENGTH(A) (T)THICKNESS LENGTH AFTER ALLEN HEAD (H) THREAD (L)(B) (C) TIGHTENING HEX ACROSS FLATS SIZE(D)LS-200-* 0.48” 1.75” 1.38” 1.06” 0.31” 4mm Allen (0.157”) 4.95mm (0.195”) M5-0.8 70mm (2.755”) 0.70 2.25”LS-275-* 0.61” 1.75” 1.38” 0.97” 0.31” 4mm Allen (0.157”) 4.95mm (0.195”) M5-0.8 70mm (2.755”) 0.75 2.25”LS-300-* 0.69” 2.37” 1.87” 1.56” 0.44” 6mm Allen (0.236”) 7.87mm (0.310”) M8-1.25 90mm (3.543”) 2.15 3.00”LS-315-* 0.81” 2.37” 1.87” 1.44” 0.44” 6mm Allen (0.236”) 7.87mm (0.310”) M8-1.25 90mm (3.543”) 2.30 3.00”LS-325-* 0.88” 2.63” 2.00” 3.13” 1.00” 13mm (0.511”) 5.30mm (0.215”) M8-1.25 90mm (3.543”) 5.50 4.00”LS-340-* 1.00” 2.70” 2.25” 1.48” 0.66” 13mm (0.511”) 5.30mm (0.215”) M8-1.25 120mm (4.720”) 3.30 4.00”LS-360-* 1.24” 2.70” 2.25” 2.05” 0.77” 13mm (0.511”) 5.30mm (0.215”) M8-1.25 120mm (4.720”) 5.10 4.00”LS-400-* 1.38” 3.50” 2.75” 3.50” 1.06” 17mm (0.669”) 6.40mm (0.250”) M10-1.5 130mm (5.118”) 12.00 5.00”LS-410-* 1.43” 3.37” 2.87” 2.52” 0.88” 17mm (0.669”) 6.40mm (0.250”) M10-1.5 130mm (5.118”) 8.20 5.00”LS-425-* 1.06” 3.00” 2.25” 3.50” 1.19” 17mm (0.669”) 6.40mm (0.250”) M10-1.5 130mm (5.118”) 10.00 5.00”LS-475-* 1.56” 3.38” 2.63” 2.63” 0.88” 17mm (0.669”) 6.40mm (0.250”) M10-1.5 130mm (5.118”) 10.00 5.00”LS-500-* 2.25” 3.75” 2.75” 3.63” 1.06” 19mm (0.748”) 7.50mm (0.300”) M12-1.75 140mm (5.511”) 22.50 5.00”LS-525-* 2.06” 3.75” 2.87” 3.63” 1.06” 19mm (0.748”) 7.50mm (0.300”) M12-1.75 140mm (5.511”) 21.00 5.00”LS-575-* 1.81” 3.75” 3.00” 3.00” 1.00” 19mm (0.748”) 7.50mm (0.300”) M12-1.75 140mm (5.511”) 15.50 5.00”LS-600-* 3.09” 4.00” 3.00” 6.00” 1.90” 30mm (0.748”) 12.50mm (0.490”) M20-2.5 180mm (7.086”) 60.60 6.00”LS-650-* 2.71” 3.98” 3.00” 3.96” 1.19” 19mm (0.748”) 7.50mm (0.300”) M12-1.75 140mm (5.511”) 26.10 6.00”LINK-SEALMODEL NO.WEIGHTFOR10 LINKSECTION(LBS)MIN.REQUIREDSEATINGWIDTHFor LS-325 through LS-650For LS-200 through LS-315Dimensional Datahttp://www.powercanadasolutions.com/linkseal.html 8Sizing Procedure - Method 1Link-Seal® Modular Seals may be sized by using one or more methods.Method 1 - Use the charts provided (Pages 8, 9, 10 & 11) for standard pipe sizes and types.How to Order: Using the Provided Sizing Charts1. Locate charts on pages 8-11 that corresponds to the type and size pipe being used.2. Verify that your pipe O.D. matches the actual outside diameter shown on the chart.3. Determine type of wall opening (Century-Line, Steel Sleeve or Cast/Core Bit Drilled Hole).4. Determine Link-Seal Modular Seal model to be used (See information on page 5).5. To order Link-Seal Modular Seals: under the appropriate wall opening column, Link-Seal Modular Seal size (from SIZE column),Link-Seal Modular Seal model *** (C, S-316, L, LS-316, LS-S61, O, OS-316, T or FD/FS from page 5) and indicate number of links required per seal (from LINKS PER SEAL column). [Example: LS-575-C-10]6. To order corresponding sleeves indicate model number (from MODEL NUMBER column), length of sleeve and quantity required.[Century-Line Example: CS-10-12”-1] [Steel Sleeve Example: WS-36-S-12”-1] [Cell-Cast Example: CC-32-(3”)2-(4”)2] See Page 25 for detailed visual call-outs.Note: Contact PSI (1-800-423-2410) or your local distributor if your pipe sizing solution is not listed in the provided charts.Link-Seal® Modular Seal Sizing Charts for Standard PipeSteel and Plastic Pipe with Same Outside Diameter (IPS)CENTURY-LINE® SLEEVE STEEL SLEEVE CAST OR CORE BIT DRILLED HOLEPIPE ACTUALSIZE O.D. MODEL LINK-SEAL® LINKS MODEL LINK-SEAL® LINKS HOLE LINK-SEAL® LINKS(Nom.) (Inches) NUMBER SIZE PER SEAL NUMBER SIZE PER SEAL I.D. SIZE PER SEAL1/2 0.840 CS-2-* LS-200-*** 4 WS-2-15-S-* LS-275-*** 5 2.000 LS-200-*** 43/4 1.050 CS-3-* LS-315-*** 4 WS-2-1/2-20-S-* LS-275-*** 6 3.000 LS-315-*** 41 1.315 CS-3-* LS-300-*** 4 WS-2-1/2-20-S-* LS-200-*** 5 3.000 LS-300-*** 41-1/4 1.660 CS-3-* LS-275-*** 7 WS-3-21-S-* LS-275-*** 8 3.000 LS-275-*** 81-1/2 1.900 CS-3-1/2-* LS-300-*** 5 WS-3-21-S-* LS-200-*** 7 4.000 LS-315-*** 62 2.375 CS-4-* LS-300-*** 6 WS-3-1/2-22-S-* LS-200-*** 8 4.000 LS-300-*** 62-1/2 2.875 CS-4-* LS-200-*** 9 WS-4-23-S-* LS-200-*** 9 4.000 LS-200-*** 93 3.500 CS-5-* LS-300-*** 8 WS-6-28-S-* LS-360-*** 7 5.000 LS-300-*** 83-1/2 4.000 CS-6-* LS-340-*** 10 WS-6-28-S-* LS-340-*** 9 6.000 LS-315-*** 104 4.500 CS-6-* LS-300-*** 10 WS-6-28-S-* LS-300-*** 10 6.000 LS-300-*** 105 5.563 CS-8-* LS-360-*** 10 WS-8-32-S-* LS-340-*** 13 8.000 LS-340-*** 136 6.625 CS-10-* LS-475-*** 10 WS-10-36-S-* LS-475-*** 10 10.000 LS-475-*** 108 8.625 CS-12-* LS-475-*** 12 WS-12-37-S-* LS-475-*** 12 12.000 LS-475-*** 1210 10.750 CS-14-* LS-410-*** 15 WS-14-37-S-* LS-425-*** 10 14.000 LS-475-*** 1412 12.750 CS-16-* LS-475-*** 17 WS-16-37-S-* LS-425-*** 12 16.000 LS-475-*** 1714 14.000 CS-16-* LS-340-*** 30 WS-18-37-S-* LS-475-*** 18 18.000 LS-575-*** 1616 16.000 CS-20-* LS-410-*** 21 WS-20-37-S-* LS-475-*** 21 20.000 LS-575-*** 1818 18.000 CS-22-* LS-340-*** 38 WS-22-37-S-* LS-475-*** 23 22.000 LS-575-*** 2020 20.000 CS-25-* LS-500-*** 18 WS-24-37-S-* LS-475-*** 25 24.000 LS-475-*** 2622 22.000 CS-25-* LS-360-*** 34 WS-26-37-S-* LS-475-*** 28 26.000 LS-575-*** 2424 24.000 CC-30-** LS-500-*** 21 WS-28-37-S-* LS-475-*** 30 28.000 LS-475-*** 3126 26.000 CC-30-** LS-400-*** 23 WS-30-37-S-* LS-400-*** 23 30.000 LS-575-*** 2828 28.000 CC-32-** LS-400-*** 25 WS-32-37-S-* LS-400-*** 25 32.000 LS-575-*** 3030 30.000 CC-36-** LS-500-*** 26 WS-34-37-S-* LS-400-*** 27 34.000 LS-575-*** 3232 32.000 CC-38-** LS-500-*** 28 WS-36-37-S-* LS-400-*** 29 36.000 LS-575-*** 3434 34.000 CC-38-** LS-400-*** 30 WS-40-37-S-* LS-500-*** 29 38.000 LS-575-*** 3636 36.000 CC-42-** LS-500-*** 31 WS-42-37-S-* LS-500-*** 31 40.000 LS-575-*** 3842 42.000 CC-48-** LS-500-*** 36 WS-48-37-S-* LS-500-*** 36 46.000 LS-575-*** 4448 48.000 CC-54-** LS-500-*** 40 WS-53-37-S-* LS-525-*** 40 52.000 LS-575-*** 50* = Specify sleeve length in inches ** = See Cell-Cast® Page 16 *** = Specify LS Model C, S-316, L...etc when ordering (Example LS-475-C-17)Technically there is no limit to the pipe size that can be sealed using Link-Seal® modular seals. Please contact factory for sizes not listed and for CSmodel plastic sleeves for walls less than 8” thick. PIPESIZE9Sizing Charts for Standard PipeSDR-35 Gravity Sewer PipeCENTURY-LINE® SLEEVE STEEL SLEEVE CAST OR CORE BIT DRILLED HOLEPIPE ACTUALSIZE O.D. MODEL LINK-SEAL® LINKS MODEL LINK-SEAL® LINKS HOLE LINK-SEAL® LINKS(Nom.) (Inches) NUMBER SIZE PER SEAL NUMBER SIZE PER SEAL I.D. SIZE PER SEAL4 4.22 CS-6-* LS-315-*** 11 WS-6-28-S-* LS-315-*** 10 6.000 LS-315-*** 106 6.28 CS-8-* LS-315-*** 15 WS-8-32-S-* LS-315-*** 15 8.000 LS-315-*** 158 8.40 CS-10-* LS-325-*** 9 WS-10-36-S-* LS-315-*** 19 12.000 LS-475-*** 1210 10.50 CS-14-* LS-475-*** 14 WS-14-37-S-* LS-360-*** 17 14.000 LS-475-*** 1412 12.50 CS-18-* LS-500-*** 12 WS-16-37-S-* LS-360-*** 20 16.000 LS-475-*** 1715 15.30 CS-20-* LS-475-*** 20 WS-20-37-S-* LS-575-*** 17 18.000 LS-360-*** 2418 18.70 CS-24-* LS-575-*** 21 WS-22-37-S-* LS-360-*** 29 22.000 LS-475-*** 2421 22.05 CC-30-** LS-600-*** 13 WS-26-37-S-* LS-475-*** 28 26.000 LS-575-*** 2424 24.80 CC-30-** LS-525-*** 21 WS-28-37-S-* LS-425-*** 22 28.000 LS-475-*** 3127 27.95 CC-32-** LS-400-*** 25 WS-32-37-S-* LS-400-*** 25 32.000 LS-575-*** 3030 32.00 CC-38-** LS-500-*** 28 WS-36-37-S-* LS-400-*** 29 36.000 LS-575-*** 34* = Specify sleeve length in inches ** = See Cell-Cast® Page 16 *** = Specify LS Model C, S-316, L...etc when ordering (Example LS-475-C-17)PIPESIZECopper TubingCENTURY-LINE® SLEEVE STEEL SLEEVE CAST OR CORE BIT DRILLED HOLEPIPE ACTUALSIZE) O.D. MODEL LINK-SEAL® LINKS MODEL LINK-SEAL® LINKS HOLE LINK-SEAL® LINKS(Nom.) (Inches) NUMBER SIZE PER SEAL NUMBER SIZE PER SEAL I.D. SIZE PER SEAL1/2 0.625 CS-2-* LS-275-*** 4 WS-2-15-S-* LS-275-*** 5 2.000 LS-275-*** 43/4 0.875 CS-2-* LS-200-*** 4 WS-2-1/2-20-S-* LS-275-*** 6 2.000 LS-200-*** 41 1.125 CS-3-* LS-315-*** 4 WS-2-1/2-20-S-* LS-275-*** 6 3.000 LS-315-*** 41-1/4 1.375 CS-3-* LS-275-*** 8 WS-2-1/2-20-S-* LS-200-*** 5 3.000 LS-300-*** 41-1/2 1.625 CS-3-* LS-275-*** 8 WS-3-21-S-* LS-275-*** 7 3.000 LS-275-*** 82 2.125 CS-4-* LS-315-*** 6 WS-3-1/2-22-S-* LS-275-*** 10 4.000 LS-315-*** 62-1/2 2.625 CS-4-* LS-275-*** 12 WS-4-23-S-* LS-275-*** 11 4.000 LS-275-*** 113 3.125 CS-5-* LS-340-*** 8 WS-5-25-S-* LS-315-*** 8 5.000 LS-315-*** 84 4.125 CS-6-* LS-315-*** 11 WS-6-28-S-* LS-315-*** 10 6.000 LS-315-*** 106 6.125 CS-8-* LS-315-*** 15 WS-8-32-S-* LS-315-*** 15 8.000 LS-315-*** 158 8.125 CS-12-* LS-575-*** 10 WS-10-36-S-* LS-315-*** 19 12.000 LS-575-*** 1010 10.125 CS-12-* LS-340-*** 22 WS-14-37-S-* LS-410-*** 14 14.000 LS-575-*** 1212 12.125 CS-16-* LS-575-*** 14 WS-16-37-S-* LS-410-*** 16 16.000 LS-575-*** 14Ductile Iron Pipe (DIPS, AWWA-C900, AWWA-C905, PVC Water Pipe)CENTURY-LINE® SLEEVE STEEL SLEEVE CAST OR CORE BIT DRILLED HOLEPIPE ACTUALSIZE O.D. MODEL LINK-SEAL® LINKS MODEL LINK-SEAL® LINKS HOLE LINK-SEAL® LINKS(Nom.) (Inches) NUMBER SIZE PER SEAL NUMBER SIZE PER SEAL I.D. SIZE PER SEAL2 2.500 CS-4-* LS-300-*** 6 WS-3-1/2-22-S-* LS-200-*** 8 4.000 LS-300-*** 62-1/4 2.750 CS-4-* LS-275-*** 10 WS-4-23-S-* LS-200-*** 9 4.000 LS-200-*** 93 3.960 CS-6-* LS-340-*** 10 WS-6-28-S-* LS-340-*** 9 6.000 LS-315-*** 104 4.800 CS-8-* LS-475-*** 8 WS-8-32-S-* LS-410-*** 7 8.000 LS-410-*** 76 6.900 CS-10-* LS-475-*** 10 WS-10-36-S-* LS-410-*** 10 10.000 LS-410-*** 108 9.050 CS-12-* LS-400-*** 9 WS-12-37-S-* LS-400-*** 9 12.000 LS-400-*** 910 11.100 CS-14-* LS-410-*** 15 WS-14-37-S-* LS-340-*** 24 14.000 LS-400-*** 1012 13.200 CS-18-* LS-575-*** 15 WS-18-37-S-* LS-475-*** 18 16.000 LS-360-*** 2114 15.300 CS-20-* LS-475-*** 20 WS-20-37-S-* LS-575-*** 17 18.000 LS-360-*** 2416 17.400 CS-22-* LS-360-*** 28 WS-22-37-S-* LS-475-*** 23 20.000 LS-360-*** 2718 19.500 CS-24-* LS-410-*** 25 WS-24-37-S-* LS-575-*** 21 24.000 LS-525-*** 1720 21.600 CS-25-* LS-400-*** 20 WS-26-37-S-* LS-475-*** 27 26.000 LS-525-*** 1924 25.800 CC-30-** LS-400-*** 23 WS-30-37-S-* LS-400-*** 23 28.000 LS-425-*** 2330 32.000 CC-38-** LS-500-*** 28 WS-36-37-S-* LS-400-*** 29 36.000 LS-575-*** 3436 38.300 CC-44-** LS-500-*** 33 WS-44-1/2-37-S-* LS-500-*** 33 42.000 LS-575-*** 4042 44.500 CC-50-** LS-500-*** 38 WS-50-37-S-* LS-500-*** 38 50.000 LS-500-*** 3848 50.800 CC-56-** LS-500-*** 43 WS-57-37-S-* LS-500-*** 43 56.000 LS-500-*** 43* = Specify sleeve length in inches ** = See Cell-Cast® Page 16 *** = Specify LS Model C, S-316, L...etc when ordering (Example LS-475-C-17)* = Specify sleeve length in inches *** = Specify LS Model C, S-316, L...etc when ordering (Example LS-475-C-17) Technically there is no limit to the conduit or pipe size that canbe sealed using Link-Seal® Modular Seals. Please contactfactory for sizes not listed and for CS model plastic sleeves forwalls less than 8” thick.10Cast Iron Soil Pipe (Extra Heavy)CENTURY-LINE® SLEEVE STEEL SLEEVE CAST OR CORE BIT DRILLED HOLEPIPE ACTUALSIZE O.D. MODEL LINK-SEAL® LINKS MODEL LINK-SEAL® LINKS HOLE LINK-SEAL® LINKS(Nom.) (Inches) NUMBER SIZE PER SEAL NUMBER SIZE PER SEAL I.D. SIZE PER SEAL2 2.380 CS-4-* LS-300-*** 6 WS-3-1/2-22-S-* LS-200-*** 8 4.000 LS-300-*** 63 3.500 CS-5-* LS-315-*** 9 WS-6-28-S-* LS-360-*** 7 5.000 LS-300-*** 84 4.500 CS-8-* LS-475-*** 8 WS-6-28-S-* LS-300-*** 10 6.000 LS-300-*** 105 5.500 CS-8-* LS-360-*** 10 WS-8-32-S-* LS-340-*** 13 8.000 LS-340-*** 136 6.500 CS-8-* LS-315-*** 15 WS-10-36-S-* LS-475-*** 10 10.000 LS-475-*** 108 8.620 CS-12-* LS-475-*** 12 WS-12-37-S-* LS-475-*** 12 12.000 LS-475-*** 1210 10.750 CS-14-* LS-410-*** 15 WS-14-37-S-* LS-425-*** 10 14.000 LS-475-*** 1412 12.750 CS-16-* LS-475-*** 17 WS-16-37-S-* LS-425-*** 12 16.000 LS-475-*** 1715 15.880 CS-20-* LS-410-*** 21 WS-20-37-S-* LS-475-*** 20 18.000 LS-340-*** 33Sizing Charts for Standard Pipe* = Specify sleeve length in inches *** = Specify LS Model C, S-316, L...etc when ordering (Example LS-475-C-17)PIPESIZEElectrical Metallic Tubing (EMT) Thin WallCENTURY-LINE® SLEEVE STEEL SLEEVE CAST OR CORE BIT DRILLED HOLEConduit ACTUALSIZE O.D. MODEL LINK-SEAL® LINKS MODEL LINK-SEAL® LINKS HOLE LINK-SEAL® LINKS(Nom.) (Inches) NUMBER SIZE PER SEAL NUMBER SIZE PER SEAL I.D. SIZE PER SEAL1/2 0.706 CS-2-* LS-275-*** 4 WS-2-15-S-* LS-275-*** 5 2.000 LS-275-*** 43/4 0.922 CS-2-* LS-200-*** 4 WS-2-1/2-20-S-* LS-275-*** 6 2.000 LS-200-*** 41 1.163 CS-3-* LS-315-*** 4 WS-2-1/2-20-S-* LS-275-*** 6 3.000 LS-315-*** 41-1/4 1.510 CS-3-* LS-275-*** 8 WS-3-30-S-* LS-275-*** 7 3.000 LS-275-*** 81-1/2 1.740 CS-3-1/2-* LS-300-*** 5 WS-3-21-S-* LS-275-*** 8 3.000 LS-200-*** 62 2.197 CS-4-* LS-315-*** 6 WS-3-1/2-22-S-* LS-275-*** 10 4.000 LS-315-*** 62-1/2 2.875 CS-4-* LS-200-*** 9 WS-4-23-S-* LS-200-*** 9 4.000 LS-200-*** 93 3.500 CS-5-* LS-315-*** 9 WS-6-28-S-* LS-360-*** 7 5.000 LS-300-*** 84 4.500 CS-8-* LS-475-*** 8 WS-6-28-S-* LS-300-*** 10 6.000 LS-300-*** 10Cast Iron Soil Pipe (Service Weight)CENTURY-LINE® SLEEVE STEEL SLEEVE CAST OR CORE BIT DRILLED HOLEPIPE ACTUALSIZE O.D. MODEL LINK-SEAL® LINKS MODEL LINK-SEAL® LINKS HOLE LINK-SEAL® LINKS(Nom.) (Inches) NUMBER SIZE PER SEAL NUMBER SIZE PER SEAL I.D. SIZE PER SEAL2 2.300 CS-4-* LS-300-*** 6 WS-4-23-S-* LS-315-*** 6 4.000 LS-315-*** 63 3.300 CS-5-* LS-300-*** 8 WS-6-28-S-* LS-360-*** 7 5.000 LS-300-*** 84 4.300 CS-6-* LS-300-*** 10 WS-6-28-S-* LS-315-*** 10 6.000 LS-300-*** 105 5.300 CS-8-* LS-410-*** 8 WS-8-32-S-* LS-360-*** 9 8.000 LS-360-*** 96 6.300 CS-8-* LS-315-*** 15 WS-8-32-S-* LS-315-*** 15 8.000 LS-315-*** 158 8.380 CS-10-* LS-325-*** 9 WS-10-36-S-* LS-315-*** 19 10.000 LS-315-*** 1910 10.500 CS-14-* LS-475-*** 14 WS-14-37-S-* LS-360-*** 17 14.000 LS-475-*** 1412 12.500 CS-18-* LS-500-*** 12 WS-16-37-S-* LS-360-*** 20 16.000 LS-475-*** 1715 15.620 CS-20-* LS-475-*** 20 WS-20-37-S-* LS-475-*** 20 18.000 LS-425-*** 14* = Specify sleeve length in inches *** = Specify LS Model C, S-316, L...etc when ordering (Example LS-475-C-17)* = Specify sleeve length in inches *** = Specify LS Model C, S-316, L...etc when ordering (Example LS-475-C-17)Technically there is no limit to the conduit or pipe size that can be sealed using Link-Seal® modular seals.Please contact factory for sizes not listed and for CS model plastic sleeves for walls less than 8” thick.http://www.powercanadasolutions.com/linkseal.html http://www.powercanadasolutions.com/linkseal.html Rigid (RSC), Aluminum (ASC), Galvanized (GSC), Non-Metallic Conduit (NRC)CENTURY-LINE® SLEEVE STEEL SLEEVE CAST OR CORE BIT DRILLED HOLEConduit ACTUALSIZE O.D. MODEL LINK-SEAL® LINKS MODEL LINK-SEAL® LINKS HOLE LINK-SEAL® LINKS(Nom.) (Inches) NUMBER SIZE PER SEAL NUMBER SIZE PER SEAL I.D. SIZE PER SEAL1/2 0.840 CS-2-* LS-200-*** 4 WS-2-15-S-* LS-275-*** 5 2.000 LS-200-*** 43/4 1.050 CS-3-* LS-315-*** 4 WS-2-1/2-20-S-* LS-275-*** 6 3.000 LS-315-*** 41 1.315 CS-3-* LS-300-*** 4 WS-2-1/2-20-S-* LS-200-*** 5 3.000 LS-300-*** 41-1/4 1.660 CS-3-* LS-275-*** 7 WS-3-21-S-* LS-275-*** 8 3.000 LS-275-*** 81-1/2 1.900 CS-3-1/2-* LS-300-*** 5 WS-3-21-S-* LS-200-*** 7 4.000 LS-315-*** 62 2.375 CS-4-* LS-300-*** 6 WS-3-1/2-22-S-* LS-200-*** 8 4.000 LS-300-*** 62-1/2 2.875 CS-4-* LS-200-*** 9 WS-4-23-S-* LS-200-*** 9 4.000 LS-200-*** 93 3.500 CS-5-* LS-300-*** 8 WS-6-28-S-* LS-360-*** 7 5.000 LS-300-*** 83-1/2 4.000 CS-6-* LS-340-*** 10 WS-6-28-S-* LS-340-*** 9 6.000 LS-315-*** 104 4.500 CS-6-* LS-300-*** 10 WS-6-28-S-* LS-300-*** 10 6.000 LS-300-*** 105 5.563 CS-8-* LS-360-*** 10 WS-8-32-S-* LS-340-*** 13 8.000 LS-340-*** 136 6.625 CS-10-* LS-475-*** 10 WS-10-36-S-* LS-475-*** 10 10.000 LS-475-*** 10* = Specify sleeve length in inches *** = Specify LS Model C, S-316, L...etc when ordering (Example LS-475-C-17)Technically there is no limit to the conduit or pipe size that can be sealed using Link-Seal® modular seals.Please contact factory for sizes not listed and for CS model plastic sleeves for walls less than 8” thick.11Intermediate Metal Conduit (IMC)CENTURY-LINE® SLEEVE STEEL SLEEVE CAST OR CORE BIT DRILLED HOLEConduit ACTUALSIZE O.D. MODEL LINK-SEAL® LINKS MODEL LINK-SEAL® LINKS HOLE LINK-SEAL® LINKS(Nom.) (Inches) NUMBER SIZE PER SEAL NUMBER SIZE PER SEAL I.D. SIZE PER SEAL1/2 0.815 CS-2-* LS-200-*** 4 WS-2-15-S-* LS-275-*** 5 2.000 LS-200-*** 43/4 1.029 CS-2-* LS-200-*** 4 WS-2-1/2-20-S-* LS-275-*** 6 2.000 LS-200-*** 41 1.290 CS-3-1/2-* LS-315-*** 5 WS-2-1/2-20-S-* LS-200-*** 5 3.000 LS-300-*** 41-1/4 1.638 CS-3-* LS-275-*** 8 WS-3-21-S-* LS-275-*** 8 3.000 LS-275-*** 81-1/2 1.883 CS-3-1/2-* LS-300-*** 5 WS-3-21-S-* LS-200-*** 7 4.000 LS-315-*** 62 2.360 CS-4-* LS-300-*** 6 WS-3-1/2-22-S-* LS-200-*** 8 4.000 LS-300-*** 62-1/2 2.857 CS-4-* LS-200-*** 9 WS-4-23-S-* LS-200-*** 9 4.000 LS-200-*** 93 3.476 CS-5-* LS-315-*** 9 WS-6-28-S-* LS-360-*** 7 5.000 LS-300-*** 83-1/2 3.970 CS-6-* LS-340-*** 10 WS-6-28-S* LS-340-*** 9 6.000 LS-315-*** 104 4.466 CS-6-* LS-315-*** 11 WS-6-28-S-* LS-300-*** 10 6.000 LS-300-*** 10Sizing Charts for Standard Pipe* = Specify sleeve length in inches *** = Specify LS Model C, S-316, L...etc when ordering (Example LS-475-C-17)PIPESIZEFor Link Seal, Wall Sleeves, Hole forming disk, Casing Spacers, Contact Power Plant Supply Co. Convenient shipping warehouse locations in Canada, to serve customers in Ontario, ON, Quebec, QC, Atlantic Canada, including New Brunswick, NB, PEI, Nova Scotia, NS, Newfoundland & Labrador, NL, British Columbia, BC, Alberta, AB, Manitoba, Man, Saskatchewan, SK, Nunavut, Northwest Territories, NWT, Yukon. Next day Air or convenient ground to major cities including Vancouver, Calgary, Edmonton, Fort McMurray, Winnipeg, Yellowknife, Thunder Bay, Hamilton, Toronto, Ottawa, Montreal, Quebec City, Saint John, Moncton, Fredericton, Charlottetown, Halifax, Sydney, Corner Brook, St John's Method 2 - Link-Seal® Modular Seal SizingIf your pipe size does not appear in the charts on pages8,9, 10 & 11, use the following method to select the cor-rect Link-Seal® modular seal for your application.1. Calculate the annular space. The annular space is halfthe difference between the actual pipe O.D. and the actual wall I.D. opening diameter. Use the following formula.Annular Space = Wall Opening I.D. - Actual Pipe O.D.22. From the adjacent chart, select the size closest to theannular space calculated in step 1. You have selectedthe correct size Link-Seal® modular seal if....the free statethickness is less than the annular space...and theexpanded state thickness is greater than the annularspace.3. Calculate the number of links required to fit around thepipe and seal the annular space.A. Determine the bolt circle for your Link-Seal® modu-lar seal assembly by using the following formula.Bolt Circle = Wall Opening I.D. + Pipe Diameter O.D.2B. Find the Link-Seal® modular seal chord length(Column 4) and use the following formula to deter-mine required number of links per Link-Seal® modularseal assembly.Links Per Seal = Bolt Circle x 3.14Chord LengthThe result must be rounded down to the next whole number.The figures are accurate if the calculation results in 13 or more linksper belt. If the results are fewer than 13 links verify using the tableson pages 13 and 14.Example Wall Opening I.D. = 12”Actual Pipe O.D. = 9.05”Calculate the annular space (1.475”). Select the Link-Seal® modular sealsize closest to the annular space. LS-400 is chosen from the chart,because 1.475” falls between 1.43 & 1.81 (the free state and expandedstate thickness.)Determine the number oflinks for a completeassembly.Chord Length for LS-400 = 3.625”Links Per Seal = 9.12, rounded down = 9Since the final calculation results in fewer than 13 links,it is advisable to verify the accuracy of the calculationby using the verification tables on pages 13 and 14.LINK-SEAL FREE STATE EXPANDED STATE CHORDSIZE THICKNESS THICKNESS LENGTHLS-200 0.50” 0.64” 1.120”LS-275 0.62” 0.80” 0.906”LS-300 0.71” 0.92” 1.510”LS-315 0.82” 1.10” 1.469”LS-325 0.94” 1.14” 3.110”LS-340 1.05” 1.33” 1.575”LS-360 1.29” 1.65” 2.106”LS-400 1.43” 1.87” 3.622”LS-410 1.48” 1.91” 2.598”LS-425 1.13” 1.43” 3.622”LS-475 1.62” 2.08” 2.630”LS-500 2.37” 2.81” 3.860”LS-525 2.18” 2.58” 3.860”LS-575 1.88” 2.35” 3.100”LS-600 3.20” 4.00” 6.000”LS-650 2.76” 3.57” 4.16”* = Free state thickness includes an insertion tolerance, andtherefore, differs from the actual thickness as listed in Link-Seal modu-lar seal dimensional data on page 6. Sizing Procedure - Method 2Annular Space = 12 - 9.05 = 1.4752Bolt Circle = 12 + 9.05 = 10.5252Links Per Seal = 10.525 x 3.14 = 9.123.625Chord LengthExpanded StateThicknessFree StateThicknessLink-Seal Model Minimum RequiredSelected for Penetration Seating WidthLS-200/275 2.25”LS-300/315 3.00”LS-325/340/360 4.00”LS-400/410/425/475 5.00”LS-500/525/575 5.00”LS-600/650 6.00”Suggested Pipe O.D. Range* = Whenever possible use thicker links, such as the LS-400, LS-475 or LS-500 series toprovide more leeway.12Calculations using Link-Seal modular seal sizing Method 2may indicate that a smaller link may be used when com-pared to data on the above chart. NOTE: This chart is basedon using an average of two pipe size differential opening.13Link-Seal® LS-275 Verification Chartfor Range #1 for Range #2 for Range #1 & 2Range #1 Range #2 Minimum Pipe O.D. plus Pipe O.D. plus No.Pipe O.D. Pipe O.D. Wall Number Below = Number Below = Links/Min. - Max. Min. - Max. Opening Min. Wall Max. Wall SealOpening Opening0.194-0.554 0.554-0.797 1.786 1.231 1.592 40.475-0.828 0.828-1.190 2.067 1.239 1.592 50.773-1.079 1.079-1.550 2.365 1.286 1.592 61.062-1.334 1.334-1.917 2.654 1.320 1.592 71.345-1.593 1.593-2.289 2.937 1.344 1.592 81.625-1.853 1.853-2.663 3.216 1.363 1.592 91.901-2.115 2.115-3.039 3.493 1.378 1.592 102.176-2.378 2.378-3.417 3.768 1.391 1.592 112.450-2.641 2.641-3.795 4.042 1.401 1.592 12Link-Seal® LS-200 Verification Chartfor Range #1 for Range #2 for Range #1 & 2Range #1 Range #2 Minimum Pipe O.D. plus Pipe O.D. plus No.Pipe O.D. Pipe O.D. Wall Number Below = Number Below = Links/Min. - Max. Min. - Max. Opening Min. Wall Max. Wall SealOpening Opening0.757-0.909 0.909-1.084 2.033 1.124 1.277 41.072-1.323 1.323-1.475 2.349 1.026 1.277 51.400-1.713 1.713-1.862 2.677 0.964 1.277 61.775-2.051 2.051-2.208 3.052 1.000 1.277 72.146-2.390 2.390-2.563 3.422 1.032 1.277 82.512-2.731 2.731-2.925 3.789 1.057 1.277 92.874-3.074 3.074-3.291 4.151 1.077 1.277 103.235-3.419 3.419-3.658 4.511 1.093 1.277 113.593-3.764 3.764-4.027 4.870 1.106 1.277 12Link-Seal® LS-315 Verification Chartfor Range #1 for Range #2 for Range #1 & 2Range #1 Range #2 Minimum Pipe O.D. plus Pipe O.D. plus No.Pipe O.D. Pipe O.D. Wall Number Below = Number Below = Links/Min. - Max. Min. - Max. Opening Min. Wall Max. Wall SealOpening Opening0.665-0.982 0.982-1.208 2.860 1.878 2.195 41.082-1.530 1.530-1.795 3.278 1.748 2.195 51.517-2.047 2.047-2.359 3.712 1.665 2.195 61.961-2.549 2.549-2.917 4.156 1.607 2.195 72.448-3.003 3.003-3.428 4.643 1.640 2.195 82.933-3.455 3.455-3.941 5.128 1.673 2.195 93.413-3.909 3.909-4.458 5.609 1.699 2.195 103.891-4.366 4.366-4.977 6.086 1.720 2.195 114.366-4.823 4.823-5.498 6.561 1.738 2.195 12Link-Seal® LS-325 Verification Chartfor Range #1 for Range #2 for Range #1 & 2Range #1 Range #2 Minimum Pipe O.D. plus Pipe O.D. plus No.Pipe O.D. Pipe O.D. Wall Number Below = Number Below = Links/Min. - Max. Min. - Max. Opening Min. Wall Max. Wall SealOpening Opening2.593-2.593 2.593-2.775 5.214 2.272 2.272 43.748-3.748 3.748-4.010 6.095 2.272 2.272 54.739-4.839 4.839-5.178 7.012 2.172 2.272 65.675-5.896 5.896-6.309 7.947 2.051 2.272 76.621-6.933 6.933-7.418 8.893 1.961 2.272 87.574-7.955 7.955-8.512 9.846 1.891 2.272 98.532-8.968 8.968-9.596 10.805 1.836 2.272 109.494-9.975 9.975-10.673 11.766 1.791 2.272 1110.458-10.976 10.976-11.744 12.730 1.754 2.272 12Link-Seal® LS-340 Verification Chartfor Range #1 for Range #2 for Range #1 & 2Range #1 Range #2 Minimum Pipe O.D. plus Pipe O.D. plus No.Pipe O.D. Pipe O.D. Wall Number Below = Number Below = Links/Min. - Max. Min. - Max. Opening Min. Wall Max. Wall SealOpening Opening0.544-0.914 0.914-1.032 3.204 2.290 2.660 40.992-1.501 1.501-1.695 3.652 2.151 2.660 51.457-2.055 2.055-2.320 4.117 2.062 2.660 61.932-2.592 2.592-2.927 4.592 2.000 2.660 72.458-3.073 3.073-3.469 5.118 2.046 2.660 82.978-3.557 3.557-4.016 5.638 2.081 2.660 93.493-4.004 4.004-4.565 6.153 2.109 2.660 104.004-4.532 4.532-5.117 6.664 2.132 2.660 114.512-5.022 5.022-5.670 7.172 2.151 2.660 12Sizing Procedure- Method 2 (Verification)Verification - Link-Seal® Modular Seal SizingThe following charts will allow you to confirm the accuracy ofthis information.1. Refer to the chart for the Link-Seal® modular seal sizecalculated in Sizing Procedure - Method 2. (LS-200,LS-300 etc.)2. Find the range your pipe O.D. falls within.(It may fall in either Range #1 or Range #2).You now have minimum and maximum wall opening dimen-sions. If your wall opening size falls between these dimensions,your Link-Seal® modular seal size is correct. You may also verifythe number of links from column 6. If your wall opening size isnot in the range indicated by the chart, either choose anotherLink-Seal® modular seal size, change your wall opening size orcall PSI for assistance: 1-800-423-2410 Example:Link-Seal® Size = LS-300Actual Pipe O.D. = 2.900Determine Minimum Wall Opening = 2.900 + 1.408 (from col. 4)Determine Maximum Wall Opening = 2.900 + 1.831 (from col. 5)2.900 falls within Range #2on LS-300 Chart.Minimum Wall Opening = 2.900 +1.408 = 4.308Maximum Wall Opening = 2.900 + 1.831 = 4.731Number of Links = 7 (from col. 6)Link-Seal® LS-300 Verification Chartfor Range #1 for Range #2 for Range #1 & 2Range #1 Range #2 Minimum Pipe O.D. plus Pipe O.D. plus No.Pipe O.D. Pipe O.D. Wall Number Below = Number Below = Links/Min. - Max. Min. - Max. Opening Min. Wall Max. Wall SealOpening Opening1.018-1.278 1.278-1.415 2.849 1.571 1.831 41.460-1.857 1.857-2.024 3.291 1.434 1.831 51.919-2.404 2.404-2.605 3.750 1.346 1.831 62.449-2.873 2.873-3.107 4.280 1.408 1.831 72.969-3.347 3.347-3.617 4.800 1.453 1.831 83.482-3.825 3.825-4.132 5.313 1.487 1.831 93.990-4.306 4.306-4.650 5.821 1.515 1.831 104.494-4.788 4.788-5.171 6.325 1.538 1.831 114.996-5.271 5.271-5.693 6.828 1.556 1.831 12Link-Seal® LS-360 Verification Chartfor Range #1 for Range #2 for Range #1 & 2Range #1 Range #2 Minimum Pipe O.D. plus Pipe O.D. plus No.Pipe O.D. Pipe O.D. Wall Number Below = Number Below = Links/Min. - Max. Min. - Max. Opening Min. Wall Max. Wall SealOpening Opening0.901-1.269 1.269-1.430 4.200 2.931 3.299 41.502-2.056 2.056-2.318 4.800 2.744 3.299 52.127-2.801 2.801-3.156 5.426 2.625 3.299 62.765-3.522 3.522-3.969 6.063 2.542 3.299 73.410-4.228 4.228-4.765 6.709 2.480 3.299 84.107-4.879 4.879-5.498 7.406 2.528 3.299 94.798-5.532 5.532-6.235 8.097 2.565 3.299 105.485-6.188 6.188-6.974 8.784 2.596 3.299 116.168-6.845 6.845-7.715 9.467 2.621 3.299 1214Link-Seal® LS-475 Verification Chartfor Range #1 for Range #2 for Range #1 & 2Range #1 Range #2 Minimum Pipe O.D. plus Pipe O.D. plus No.Pipe O.D. Pipe O.D. Wall Number Below = Number Below = Links/Min. - Max. Min. - Max. Opening Min. Wall Max. Wall SealOpening Opening1.017-1.490 1.490-1.773 5.174 3.685 4.158 41.750-2.451 2.451-2.754 5.907 3.457 4.158 52.512-3.359 3.359-3.692 6.670 3.311 4.158 63.291-4.238 4.238-4.621 7.448 3.210 4.158 74.078-5.101 5.101-5.544 8.236 3.135 4.158 84.920-5.903 5.903-6.493 9.078 3.175 4.158 95.763-6.700 6.700-7.272 9.921 3.221 4.158 106.601-7.501 7.501-8.139 10.758 3.258 4.158 117.434-8.303 8.303-9.009 11.592 3.289 4.158 12Sizing Procedure- Method 2 (Verification)Link-Seal® LS-500 Verification Chartfor Range #1 for Range #2 for Range #1 & 2Range #1 Range #2 Minimum Pipe O.D. plus Pipe O.D. plus No.Pipe O.D. Pipe O.D. Wall Number Below = Number Below = Links/Min. - Max. Min. - Max. Opening Min. Wall Max. Wall SealOpening Opening2.065-2.065 2.065-2.271 7.778 5.625 5.625 43.249-3.503 3.503-3.853 8.874 5.372 5.625 54.391-4.861 4.861-5.347 10.016 5.154 5.625 65.555-6.177 6.177-6.795 11.180 5.003 5.625 76.733-7.467 7.467-8.214 12.358 4.890 5.625 87.920-8.740 8.740-9.614 13.545 4.804 5.625 99.113-10.002 10.002-11.002 14.738 4.736 5.625 1010.310-11.255 11.255-12.380 15.935 4.680 5.625 1111.510-12.502 12.502-13.752 17.135 4.634 5.625 12Link-Seal® LS-525 Verification Chartfor Range #1 for Range #2 for Range #1 & 2Range #1 Range #2 Minimum Pipe O.D. plus Pipe O.D. plus No.Pipe O.D. Pipe O.D. Wall Number Below = Number Below = Links/Min. - Max. Min. - Max. Opening Min. Wall Max. Wall SealOpening Opening2.330-2.330 2.330-2.565 7.676 5.156 5.156 43.634-3.791 3.791-4.337 8.791 5.000 5.156 54.794-5.172 5.172-6.002 9.950 4.779 5.156 65.977-6.509 6.509-7.555 11.133 4.625 5.156 77.174-7.819 7.819-9.003 12.330 4.511 5.156 88.379-9.113 9.113-10.364 13.536 4.423 5.156 99.592-10.395 10.395-11.642 14.748 4.353 5.156 1010.808-11.668 11.668-12.817 15.965 4.297 5.156 1112.028-12.935 12.935-13.825 17.184 4.250 5.156 12Link-Seal® LS-575 Verification Chartfor Range #1 for Range #2 for Range #1 & 2Range #1 Range #2 Minimum Pipe O.D. plus Pipe O.D. plus No.Pipe O.D. Pipe O.D. Wall Number Below = Number Below = Links/Min. - Max. Min. - Max. Opening Min. Wall Max. Wall SealOpening Opening1.554-1.698 1.698-1.911 6.259 4.561 4.706 42.444-2.865 2.865-3.124 7.149 4.284 4.706 53.370-3.968 3.968-4.275 8.075 4.108 4.706 64.314-5.036 5.036-5.402 9.020 3.984 4.706 75.270-6.082 6.082-6.514 9.976 3.894 4.706 86.233-7.116 7.116-7.616 10.939 3.824 4.706 97.201-8.139 8.139-8.710 11.907 3.768 4.706 108.173-9.156 9.156-9.797 12.879 3.723 4.706 119.147-10.168 10.168-10.880 13.853 3.685 4.706 12Link-Seal® LS-600 Verification Chartfor Range #1 for Range #2 for Range #1 & 2Range #1 Range #2 Minimum Pipe O.D. plus Pipe O.D. plus No.Pipe O.D. Pipe O.D. Wall Number Below = Number Below = Links/Min. - Max. Min. - Max. Opening Min. Wall Max. Wall SealOpening Opening8.358-8.358 8.358-8.784 16.334 7.416 7.416 610.210-10.425 10.425-10.956 17.626 7.202 7.416 711.605-12.450 12.450-13.085 19.021 6.571 7.416 813.214-14.450 14.450-15.187 20.630 6.181 7.416 915.194-16.323 16.323-17.155 22.611 6.288 7.416 1017.162-18.203 18.203-19.131 24.578 6.376 7.416 1119.120-20.088 20.088-21.113 26.536 6.448 7.416 12Link-Seal® LS-425 Verification Chartfor Range #1 for Range #2 for Range #1 & 2Range #1 Range #2 Minimum Pipe O.D. plus Pipe O.D. plus No.Pipe O.D. Pipe O.D. Wall Number Below = Number Below = Links/Min. - Max. Min. - Max. Opening Min. Wall Max. Wall SealOpening Opening3.039-3.039 3.039-3.312 6.186 2.867 2.867 44.360-4.403 4.403-4.799 7.227 2.824 2.867 55.442-5.691 5.691-6.204 8.309 2.618 2.867 66.546-6.940 6.940-7.564 9.413 2.474 2.867 77.664-8.163 8.163-8.898 10.531 2.367 2.867 88.790-9.371 9.371-10.214 11.656 2.286 2.867 99.921-10.567 10.567-11.519 12.788 2.220 2.867 1011.057-11.756 11.756-12.814 13.924 2.168 2.867 1112.195-12.939 12.939-14.103 15.062 2.124 2.867 12Link-Seal® LS-410 Verification Chartfor Range #1 for Range #2 for Range #1 & 2Range #1 Range #2 Minimum Pipe O.D. plus Pipe O.D. plus No.Pipe O.D. Pipe O.D. Wall Number Below = Number Below = Links/Min. - Max. Min. - Max. Opening Min. Wall Max. Wall SealOpening Opening1.288-1.677 1.677-1.888 5.110 3.433 3.822 42.034-2.655 2.655-2.989 5.856 3.201 3.822 52.809-3.579 3.579-4.029 6.632 3.053 3.822 63.601-4.473 4.473-5.037 7.423 2.950 3.822 74.402-5.350 5.350-6.025 8.224 2.874 3.822 85.268-6.157 6.157-6.933 9.090 2.933 3.822 96.125-6.968 6.968-7.846 9.948 2.979 3.822 106.977-7.782 7.782-8.763 10.800 3.017 3.822 117.825-8.599 8.599-9.682 11.647 3.049 3.822 12Link-Seal® LS-400 Verification Chartfor Range #1 for Range #2 for Range #1 & 2Range #1 Range #2 Minimum Pipe O.D. plus Pipe O.D. plus No.Pipe O.D. Pipe O.D. Wall Number Below = Number Below = Links/Min. - Max. Min. - Max. Opening Min. Wall Max. Wall SealOpening Opening2.711-2.711 2.711-3.350 6.490 3.748 3.748 43.779-4.071 4.071-4.920 7.527 3.456 3.748 54.858-5.356 5.356-6.267 8.606 3.250 3.748 65.960-6.601 6.601-7.671 9.708 3.107 3.748 77.074-7.821 7.821-8.938 10.822 3.001 3.748 88.196-9.025 9.025-10.163 11.944 2.919 3.748 99.325-10.218 10.218-11.363 13.073 2.854 3.748 1010.457-11.403 11.403-12.549 14.205 2.802 3.748 1111.593-12.583 12.583-13.735 15.341 2.758 3.748 12Link-Seal® LS-650 Verification Chartfor Range #1 for Range #2 for Range #1 & 2Range #1 Range #2 Minimum Pipe O.D. plus Pipe O.D. plus No.Pipe O.D. Pipe O.D. Wall Number Below = Number Below = Links/Min. - Max. Min. - Max. Opening Min. Wall Max. Wall SealOpening Opening3.882 - 4.968 4.968 - 5.221 11.032 6.064 6.670 65.144 - 6.394 6.394 - 6.720 12.294 5.900 6.670 76.421 - 7.793 7.793 - 8.190 13.571 5.778 6.670 87.708 - 9.173 9.173 - 9.641 14.858 5.685 6.670 99.001 - 10.154 10.154 - 11.078 16.151 5.997 6.670 1010.299 - 11.898 11.898 - 12.505 17.449 5.551 6.670 1111.600 - 13.250 13.250 - 13.926 18.750 5.500 6.670 12Century-Line® Engineered SleevesWeights and Dimensional DataModel CS (16” length)MODEL I.D. (In.) I.D. (mm) O.D. (In.) lbs. Kg.CS-2 1.97 50.04 2.13 0.70 0.32CS-3 2.88 73.15 3.19 1.30 0.59CS-3-1/2 3.31 84.07 3.63 1.50 0.68CS-4 4.00 101.60 4.38 2.00 0.90CS-5 5.13 130.30 5.50 2.80 1.27CS-6 6.13 155.70 6.50 3.60 1.63CS-8 8.25 209.55 8.63 4.80 2.18CS-10 10.25 260.35 10.63 6.40 2.90CS-12 12.25 311.15 12.63 7.20 3.27CS-14 14.19 360.43 14.69 11.20 5.08CS-16 16.25 412.75 16.75 12.00 5.44CS-18 17.50 444.50 18.00 15.50 7.03CS-20 19.13 485.90 19.63 17.50 7.94CS-22 20.75 527.05 21.25 21.00 9.53CS-24 22.75 577.85 23.25 22.00 9.98CS-25 24.75 628.65 25.25 23.00 10.43Century-Line® Sleevesare used to create circular holes in concrete poured barriers of alltypes including; walls, floors and ceilings. Molded from non-con-ductive, high impact resistant HDPE, Century-Line® sleeves arelightweight and easily installed by one construction worker withoutuse of cranes or hoists. They are available in 16 diameters rang-ing from 2” to 25” (51mm -635mm) and shipped, fromstock, in any desired length. Features16 sizes - 2” to 25” in diameter. Local stock, drop ship overnight.In the event of a field or engineering change, sleeves may be cut shorter at thejob site using ordinary hand tools. Standard sleeves are 16”?(406mm) in length.Longer length models may also be quickly fabricated as a custom ordered item.1/8 the weight of steel.Century-Line® sleeves are light enough for one worker to install without a crane,hoist or helper which reduces installation time and costs. Century-Line® sleevesare easy to stock and far less expensive to ship, when compared to steelsleeves.Resists water migration.The 2” (50.8mm) water stop collar not only anchors the sleeve in position butcreates a path against the migration of water around the outside of the sleeve. Adjusts to wall thickness.Century-Line sleeves’ unique hollow water stop collar acts like an expansionjoint, adjusting (up to 1/2” - 12.7mm) to the thickness of the wall. This compres-sive force reacts against the forms like a spring, creating pressure and maintainsproper sleeve location within the form.Nailer end caps position sleeve precisely in form.Specially designed end caps provide an ideal method for attachingCentury-Line® sleeves to the concrete forms. The end capsassure that the sleeve holds its circular configuration during thepour. In addition to keeping out wet concrete, they also preventdirt from entering the sleeve during backfill operations or theinterim construction period. Tough high density polyethylene (HDPE)construction.High impact resistant HDPE also provides excel-lent resistance to acids, alkalis and other organicsolvents. Ideal for cathodic protection systems,these non-conductive sleeves will neither rust, cor-rode or degrade. Low-temperature properties are suchthat they may be installed under any weather conditionssuitable for pouring concrete. High temperature applicationlimit is 150º F. (66º C.). The sleeve is mold-ed with a texture on the outside surface toassure a better bond than most plastic toconcrete interfaces.Used for shotcrete wall applications.For shotcrete applications, Century-Linesleeves are easily positionedto wall form with threaded rod, and the endcaps protect the sleeve penetration whilethe wall is formed.How To OrderPlease see page 25 for ordering informa-tion on Link-Seal® modular seals andCentury-Line® sleeves.Nailer End CapWater Stop CollarReinforcing RibsAdjusts To Wall ThicknessCentury-Line sleeves unique hollow water stopcollar works like an expansion joint, adjusting(up to 1/2”) to the thickness of wall. This designcreates a dynamic force against the form.Nesting of SleevesAllow for a 2” minimum clearance betweenwall sleeves/water-stop collars for con-crete pour.Note: Swimming pool, floor, and shotcrete appli-cations; please specify exact lengths whenordering. Typically, a form is not installed on thetop of a pool or floor, the CS sleeve water stopwill not compress in these applications.15Weight Comparison WS Steel Sleeve Century-Line SleeveWS-12-37-S-12 = 60 lbs. CS-12-12 = 6.5 lbshttp://www.powercanadasolutions.com/linkseal.html 16FeaturesEconomy• Reduces material costs by 30 to 50%.• Cuts labor costs by 50 - 70%.• Minimizes freight and handling charges.Quality• Consistently produces dimensionally accurate openings.• Eliminates galvanic corrosion.• Avoids potential leak path between sleeve and concrete.Installation• Lightweight - 1/8 the weight of steel pipe sleeves.• Complete assembly accomplished in minutes.• Easily installed by one construction worker.Availability• Cell-Cast® Disks are stocked in a variety of diameters upto 64.75” (164cm) and available for immediate delivery.• Larger sizes are available by special order.How to Size• Cell-Cast® Disks are produced in 3” and 4” thicknessesand can be assembled to fit virtually any wall. For example:• Combine two 3” cells and one 4” cell for 10” walls.• Combine two 4” cells and one 3” cell for 11” walls.• Combine three 4” cells for 12” walls.Cell-Cast® Interlocking Hole Forming DisksCell-Cast® Hole Forming DisksCELL-CAST® HOLE 3” THICKNESS 4” THICKNESSMODEL NO. I.D. LBS KG LBS KGCC-30 29.25 10.0 4.53 10.4 4.71CC-32 31.13 10.8 4.89 11.2 5.08CC-36 34.75 12.6 5.71 13.1 5.94CC-38 37.25 13.9 6.30 14.4 6.53CC-42 41.38 16.3 7.39 16.8 7.62CC-44 43.75 17.7 8.02 18.3 8.30CC-48 47.25 20.0 9.07 20.7 9.38CC-50 50.00 22.0 9.97 22.6 10.25CC-54 52.63 23.9 10.84 24.6 11.15CC-56 56.00 26.5 12.02 27.3 12.38CC-60 59.25 29.2 13.24 30.0 13.60CC-64 62.75 32.2 14.60 33.1 15.01CC-66 64.75 34.0 15.42 34.9 15.83Cell-Cast® Interlocking Hole Forming Disks are designed to pro-duce large diameter holes in poured concrete structures. Moldedfrom non-conductive plastic, Cell-Cast® disks are lightweight andmay be installed by one construction worker. They are availablein a wide range of diameters using 3” and 4” thick modular disks.Note: For walls greater than 16”, please contact PSI at 1-800-423-2410. Please see pages 8, 9, 10 and 11 for standard size pipeand Cell-Cast® Disk ordering code page 25. Threadedrod must be requested when ordering. Specify TRA at theend of the ordering code.Typical Wall Opening SpecificationA. Century-Line® Sleeves - for openings to 24.81” diameter.Where pipes must pass through walls and floors of new structures, unless otherwise shown or specified,install molded non-metallic high density polyethylene Model CS Century-Line® sleeves as manufacturedby PSI-Thunderline/Link-Seal®. Model CS sleeves shall have integrally formed hollow water stop sizedhaving a minimum of four inches larger than the outside diameter of the sleeve itself and allowing 1/2”movement between wall forms to resist pour forces. Each sleeve assembly shall have end caps manu-factured of the same material as the sleeve itself and installed at each end of the sleeve so as to preventdeformation during the initial concrete pour, and to facilitate attaching the sleeve to the wall forms. Endcaps shall remain in place to protect the opening from residual debris and rodent entry prior to pipe insertion.B. Cell-Cast® Disks - for openings from 29.25” to64.74” diameter. The contractor shall install Cell-Cast® disks, providing a round hole in conformance with Link-Seal® modular seal sizing data. Cell-Cast® disks shall consist of 3” and/or 4” lightweight inter-locking polyethylene cells stacked to form the thickness of the poured concrete wall. Molded into each cellshall be a cavity to accept a 2” x 4” nailer. Weight Comparison Keep the contractor in mindWS Steel Sleeve Cell-Cast DisksWS-48-37-2-12 = 250 lbs. CC-48-4(3) = 62 lbs.http://www.powercanadasolutions.com/linkseal.html 17WS Steel Wall SleevesModel WS (12” length)MODEL I.D. lbs. Kg.WS-2-15-S-12 2.07 5.53 2.51WS-2-1/2-20-S-12 2.47 7.91 3.58WS-3-21-S-12 3.07 9.93 4.51WS-3-1/2-22-S-12 3.55 11.70 5.31WS-4-23-S-12 4.03 13.61 6.17WS-5-25-S-12 5.05 17.91 8.12WS-6-28-S-12 6.07 22.73 10.31ws-6-18-S-12 6.25 14.82 6.72WS-8-32-S-12 7.98 33.55 15.22ws-8-18-S-12 8.25 21.94 9.95WS-10-36-S-12 10.02 46.12 20.92ws-10-25-S-12 10.25 33.67 15.27WS-12-37-S-12 12.00 60.14 27.28WS-14-37-S-12 13.25 62.04 28.14WS-16-37-S-12 15.25 71.04 32.22WS-18-37-S-12 17.25 79.98 36.28WS-20-37-S-12 19.25 90.00 40.82WS-22-37-S-12 21.25 98.00 44.45WS-24-37-S-12 23.25 107.00 48.53WS Wall Sleeves are constructed from steel and avail-able in a wide range of diameters and lengths.They are an excellent choice for installations where theLink-Seal® Modular Seal and WS sleeve assembly wouldbe subject to extremely high temperatures or where fireseals are specified.How To OrderPlease see Page 25 for ordering information on Link-Seal® modularseals and WS Steel Sleeves. For diameters larger than 24”, contact PSIat 1-800-423-2410 WS Steel Wall Sleeve SpecificationProvide WS Steel sleeves for all pipes passing throughconcrete or masonry structures. The WS Sleeves shallbe provided free of welding slag. WS Steel Sleeve sizesthough 10” shall be Schedule 40 Steel Pipe or standardwall thickness. WS Steel Sleeve sizes 12” and larger shallhave a .375” or standard wall thickness. WS Sleevesthrough wall shall be cast in place and the pipe shall beinstalled centered in sleeve. The 2” collar, (water-stop)shall be the same type of steel as the WS sleeve. Thecollar shall be welded all around on both sides to thesleeve at the point on the sleeve that positions it at themid-point of the structural wall when the sleeve is inplace. The WS Steel Sleeve w/water-stop shall be primedinside and outside with Sherwin Williams Water Base RedPrimer or approved equivalent.Pipeline Seal and Insulator, Inc., Houston, Texas, U.S.Ashall provide WS Steel Sleeves. 2” Steel Water StopContinuous Weld-Bead on both sides.Note: ws rolled sleeves (6” & 8”) = .1875” wall thickness;(10”) = .25” wall thickness. Intermediate sleeves available, model information on-line in a pdf file.Model WS Painted and GalvanizedSteel Wall Sleeves are an excellentchoice for installations where theLink-Seal® Modular Seal and WSsleeve assembly would be subject toextremely high temperatures orwhere fire seals are specifiedWS Intermediate Sleeves are used inconjunction with Link-Seal® ModularSeals to seal all pipes passingthrough concrete or masonry struc-tures that require two belts of seals tofill the annular space between pipeand wall. Please see page 21, sealingan oversize annulus.Model WS Split Sleeves are used forinstallations where an existing piperun needs to penetrate a wall yet tobe constructed. During wall installa-tion a split sleeve is welded aroundthe existing pipe and positioned in theform to center the pipe. After installa-tion a Link-Seal® Modular Seal isused to seal the annular spacebetween split sleeve and pipe. Visit www.linkseal.com for more WS Steel Sleeve Types 18Steel Pipe Reference SchedulesPipe O.D. SCHEDULE SCHEDULE SCHEDULE DBLE.Size Inches 5 10 20 30 40 STD 60 80 E.H. 100 120 140 160 E.H.1/8” .405 .035 .049 -- -- .068 .068 -- .095 .095 -- -- -- -- --1/4” .540 .049 .065 -- -- .088 .088 -- .119 .119 -- -- -- -- --3/8” .675 .049 .065 -- -- .091 .091 -- .126 .126 -- -- -- -- --1/2” .840 .065 .083 -- -- .109 .109 -- .147 .147 -- -- -- .188 .2943/4” 1.050 .065 .083 -- -- .113 .113 -- .154 .154 -- -- -- .219 .3081” 1.315 .065 .109 -- -- .133 .133 -- .179 .179 -- -- -- .250 .3581 1/4” 1.660 .065 .109 -- -- .140 .140 -- .191 .191 -- -- -- .250 .3821 1/2” 1.900 .065 .109 -- -- .145 .145 -- .200 .200 -- -- -- .281 .4002” 2.375 .065 .109 -- -- .154 .154 -- .218 .218 -- -- -- .344 .4362 1/2” 2.875 .083 .120 -- -- .203 .203 -- .276 .276 -- -- -- .375 .5523” 3.500 .083 .120 -- -- .216 .216 -- .300 .300 -- -- -- .438 .6003 1/2” 4.000 .083 .120 -- -- .226 .226 -- .318 .318 -- -- -- -- .6364” 4.500 .083 .120 -- -- .237 .237 .281 .337 .337 -- .438 -- .531 .6744 1/2” 5.000 -- -- -- -- .247 .247 -- .355 .355 -- -- -- -- .7105” 5.563 .109 .134 -- -- .258 .258 -- .375 .375 -- .500 -- .625 .7506” 6.625 .109 .134 -- -- .280 .280 -- .432 .432 -- .562 -- .719 .8647” 7.625 -- -- -- -- -- .301 -- -- .500 -- -- -- -- .8758” 8.625 .109 .148 .250 .277 .322 .322 .406 .500 .500 .594 .719 .812 .906 .8759” 9.625 -- -- -- -- -- .342 -- -- .500 -- -- -- -- --10” 10.750 .134 .165 .250 .307 .365 .365 .500 .594 .500 .719 .844 1.000 1.125 1.00011” 11.750 -- -- -- -- -- .375 -- -- .500 -- -- -- -- --12” 12.750 .165 .180 .250 .330 .406 .375 .562 .688 .500 .844 1.000 1.125 1.312 1.00014” 14.000 -- .250 .312 .375 .438 .375 .594 .750 .500 .938 1.094 1.250 1.406 --16” 16.000 -- .250 .312 .375 .500 .375 .656 .844 .500 1.031 1.219 1.438 1.594 --18” 18.000 -- .250 .312 .438 .562 .375 .750 .938 .500 1.156 1.375 1.562 1.781 --20” 20.000 -- .250 .375 .500 .594 .375 .812 1.031 .500 1.281 1.500 1.750 1.969 --22” 22.000 -- .250 .375 .500 -- .375 .875 1.125 .500 1.375 1.625 1.875 2.125 --24” 24.000 -- .250 .375 .562 .688 .375 .969 1.219 .500 1.531 1.812 2.062 2.344 --26” 26.000 -- .312 .500 -- -- .375 -- -- .500 -- -- -- -- --28” 28.000 -- .312 .500 .625 -- .375 -- -- .500 -- -- -- -- --30” 30.000 -- .312 .500 .625 -- .375 -- -- .500 -- -- -- -- --32” 32.000 -- .312 .500 .625 .688 .375 -- -- .500 -- -- -- -- --34” 34.000 -- .312 .500 .625 .688 .375 -- -- .500 -- -- -- -- --36” 36.000 -- .312 .500 .625 .750 .375 -- -- .500 -- -- -- -- --38” 38.000 -- -- -- -- -- .375 -- -- .500 -- -- -- -- --40” 40.000 -- -- -- -- -- .375 -- -- .500 -- -- -- -- --42” 42.000 -- -- -- -- -- .375 -- -- .500 -- -- -- -- --48” 48.000 -- -- -- -- -- .375 -- -- .500 -- -- -- -- --54” 54.000 -- -- -- -- -- .375 -- -- .500 -- -- -- -- --60” 60.000 -- -- -- -- -- .375 -- -- .500 -- -- -- -- --Non Bold = Wall Thickness (Inches) STD = Standard E.H. = Extra HeavyThe following wall thickness chart has been provided to help size Link-Seal® modular seals in steel pipe sleeves of var-ious wall thicknesses. To determine the Inside Diameter (I.D.) of the proposed steel wall sleeve subtract 2 times theselected Wall Thickness (W.T.) from the actual Outside Diameter (O.D.) of the pipe.Example: Find the I.D. for a 5” (INCH) Schedule 40 Pipe.Use Chart Below:O.D. of a 5” Schedule 40 Pipe = 5.563” (INCHES)Wall Thickness of 5” Schedule 40 Pipe = .258”Wall Thickness multiplied by 2 (.258 x 2 ) = .516”I.D. of 5” Schedule 40 Pipe (5.563 - .516) = 5.047”Wall Thickness Chart For: Black Steel, API, IPS, RSC5” Schedule 40 I.D.W.T.O. D.Disclaimer Note: The above steel pipe O.D.’s are generic, Pipeline Seal and Insulator, Inc. is not a pipemanufacturer. Please always refer to the pipe manufacturer’s published/actual values. Wall Thickness Note: It’s suggested sleeves be fabricated from standard (STD) or thicker wall thickness.19Link-Seal® Modular Fire SealsLink-Seal® Modular Fire Seals - Testing Procedure1-Hour Factory Mutual ApprovedLink-Seal® modular fire seals provide up toone-hour protection against flames,smoke, gases and water, even whenexposed to temperatures up to 1900°F.(1038°C.). These seals are a proprietary Link-Seal®modular seal design formulated from Hi-Temp silicone and incorporate specialdesigned carbon steel pressure plates.For installations from 1/2” to 120” diameterLink-Seal® modular fire seals are usedwith WS wall sleeves or core bit drilledopenings.Minimum Wall & Floor Thicknessfor Model T Fire Rated SealsLINK-SEAL® MINIMUM WALLMODEL OR FLOOR THICKNESSLS-200-T 2.25” (57 mm)LS-275-T 2.25” (57 mm)LS-300-T 3.00” (76 mm)LS-315-T 3.00” (76 mm)LS-325-T 4.00” (102 mm)LS-340-T 4.00” (102 mm)LS-360-T 4.00” (102 mm)LS-400-T 5.00” (127 mm)LS-410-T 5.00” (127 mm)LS-425-T 5.00” (127 mm)LS-475-T 5.00” (127 mm)LS-500-T 5.00” (127 mm)LS-525-T 5.00” (127 mm)LS-575-T 5.00” (127 mm)Minimum Wall & Floor Thicknessfor Model FD or FS Fire Rated SealsLINK-SEAL® MINIMUM WALLMODEL OR FLOOR THICKNESSLS-200-FD or FS 4.50” (114 mm)LS-275-FD or FS 4.50” (114 mm)LS-300-FD or FS 6.00” (152 mm)LS-315-FD or FS 6.00” (152 mm)LS-325-FD or FS 8.00” (203 mm)LS-340-FD or FS 8.00” (203mm)LS-360-FD or FS 8.00” (203mm)LS-400-FD or FS 10.00” (254 mm)LS-410-FD or FS 10.00” (254 mm)LS-425-FD or FS 10.00” (254 mm)LS-475-FD or FS 10.00” (254 mm)LS-500-FD or FS 12.00” (305 mm)LS-525-FD or FS 12.00” (305 mm)LS-575-FD or FS 12.00” (305 mm)Model TOne Hour FM ApprovedApproved by Factory Mutualas a 1-hour fire stop in accor-dance with ASTM E814-81Fire & Hose Stream CriteriaListing #J.I.OH4A5.ACModel FS or FDThese are essentially two TModels back-to-back foradded protection. In ModelFS, a tie rod (nut coupler)tightens both seals simultane-ously - for use when only oneside of a hole is accessible.Model TModel FSModel FDCertified test furnace with pipeand cable penetrations andfire rated Link-Seal® modularseal installed in concrete floorslab. Twenty-seven thermocouples were used per slab.Test slab being raised fromfurnace at completion of test.(Slab was then positionedvertically for hose stream test.)Test slab after hose stream.Cold water striking the 1900°F.slab caused scalling of con-crete, but left Link-Seal® mod-ular seal intact. Unexposed side showed no evidence ofwater damage.http://www.powercanadasolutions.com/linkseal.html 20Sealing Pipeline Casings400 SeriesFor Casings Two Pipe Sizes Larger than Carrier PipeCARRIER COMPLETE CASING SEAL BASIC COMPLETEX ASSEMBLY CONSISTS OF: LINK-SEAL ASSEMBLYCASING PLAIN LINKS WITH TOTAL SIZE USED ORDER NO.PIPE LINKS CENTERING LINKSIPS Nominal BLOCKS2” X 6” 5 0 5 LS-410 26*3” X 6” 7 0 7 LS-360 36*4” X 8” 7 0 7 LS-475 48*6” X 10” 10 0 10 LS-475 610*8” X 12” 12 0 12 LS-475 812*10” X 14” 10 0 10 LS-425 1014*12” X 16” 12 0 12 LS-425 1216*14” X 18” 9 4 13 LS-400 141816” X 20” 11 4 15 LS-400 162018” X 22” 13 4 17 LS-400 182220” X 24” 13 5 18 LS-400 202422” X 26” 16 5 20 LS-400 222624” X 28” 17 5 22 LS-400 242826” X 30” 17 6 23 LS-400 263028” X 32” 18 7 25 LS-400 283230” X 34” 20 7 27 LS-400 303432” X 36” 21 8 29 LS-400 323634” X 38” 22 8 30 LS-400 343836” X 40” 24 8 32 LS-400 3640PSI End SealsModel “C” Custom Pull-onIndividually designed to accommodate all types of water and sewerpipes and carrier/casing combinations. made of 1/8” thick, speciallycompounded synthetic rubber for long life and easy installation.Model “W” Wrap Around End SealsSpecially designed for ease of installation. Simply remove plastic back-ing from self-curing rubber and press exposed surfaces together.Available for all carrier/casing differentials.Model “S” Standard Pull-on End SealsMade of special synthetic rubber for long life and easy installation, thehighly flexible “S” shaped seal is available for ANSI steel pipe specifica-tions. Band locating ribs are on the outside, with special sealing ribs onthe inside under the band to prevent leakage.All PSI End Seals include stainless steel closure clamps.PSI Casing SpacersMetallic Model C (coated) is available with 8” (208mm) or 12” (305mm) widesteel bands for 4” (10cm) to 120” (305cm) carrier pipe diameters.Model S (stainless steel) is available with8” (208mm) or 12” (305mm) wide steel bands for 4” (10cm) to 120”(305cm) carrier pipe diameters. PlasticModel PE (polyethylene) is available for 3/4” (19mm) through 48”(1210mm) and larger carrier pipe. (Not recommneded for pipe sizesover 12”.) Ranger II all non-metallic spacers are available for 0.83” (21mm)through 37.60” (955mm) carrier pipe diameters. Link-Seal® Modular Seals with Reinforced Centering Blocks.A Link-Seal® modular seal assembly installed at each end of pipelinecasings provides positive, hydrostatic pro-tection against the entry of water, soil orother backfill materials and reduces corro-sion and ice damage.* = Centering Blocks are not required and not available for these models.(Maximum coating 3/16” thick - Casing pipe walls should not exceed0.500” except for casing sizes 12”, 14” and 16”, which should not have awall thickness greater than 0.312”)** = Centering Blocks are not required for these applications.(Maximum coating 3/16” thick - Casing pipe walls should not exceed0.500” except for casing sizes 16” and 18” which should not have awall thickness greater than 0.312”)500 SeriesFor Casings Three Pipe Sizes Larger than Carrier PipeCARRIER COMPLETE CASING SEAL BASIC COMPLETEX ASSEMBLY CONSISTS OF: LINK-SEAL ASSEMBLYCASING PLAIN LINKS WITH TOTAL SIZE USED ORDER NO.PIPE LINKS CENTERING LINKSIPS Nominal BLOCKS4” X 10” 6 0 6 LS-500 410**6” X 12” 7 0 7 LS-500 612**8” X 14” 11 0 11 LS-575 814**10” X 16” 7 3 10 LS-525 101612” X 18” 9 3 12 LS-525 121814” X 20” 9 4 13 LS-500 142016” X 22” 11 4 15 LS-500 162218” X 24” 12 4 16 LS-500 182420” X 26” 13 5 18 LS-500 202622” X 28” 14 6 20 LS-500 222824” X 30” 15 6 21 LS-500 243026” X 32” 17 6 23 LS-500 263228” X 34” 18 6 24 LS-500 283430” X 36” 19 7 26 LS-500 303632” X 38” 21 7 28 LS-500 323834” X 40” 21 8 29 LS-500 344036” X 42” 23 8 31 LS-500 364242” X 48” 27 9 36 LS-500 424848” X 54” 30 11 41 LS-500 485454” X 60” 34 12 46 LS-500 5460If casing isolators are not used, starting with 14” diameter assemblies,we suggest Link-Seal® modular seals with “centering blocks” in 25% ofthe links. These centering blocks fit into molded openings in the Link-Seal® modular seals and are positioned in the lower 90° of each assem-bly. PSI centered casing isolators should also be placed within two feetof casing ends.Link-Seal® modular sealswith Centering Blocks21Typical Application Wall Opening = 40” Cored HoleCarrier Pipe = 30” API Type(30.00” O.D.)This is a differential of five pipesizes: (32, 34, 36, 38, 40)Solution:Use an inner belt of LS-400and an outer belt of LS-500. Intermediate sleeve should be two pipe sizes larger than the 30”carrier pipe. A 34” pipe with a 3/8” wall would be an excellentchoice. Checking the Link-Seal® modular seal sizing chart onpage 9 indicates a 30 x 34 WS sleeve requires 27 links of LS-400. The outer sleeve of 34 x 40 will require 29 links of LS-500. For sizing assistance call our toll free number: 1-800-423-2410.Intermediate sleeves available, information pdf file on-line.Reduce Intermediate Sleeve Applications: Try eliminatingyour intermediate sleeve needs by sizing the model LS-650. Sealing An Oversize AnnulusThe Double Row MethodSometimes the wall opening represents a differential up tofive pipe sizes larger than the carrier pipe itself. This creates anannular space that is larger than the expanded thickness of asingle Link-Seal® modular seal assembly. A typical example is aflanged spool piece or an existing opening where piping hasbeen removed to make way for a new installation. As a result itis necessary to use an intermediate sleeve and another belt ofLink-Seal® modular seals. Key design considerations when sizing an intermediate wallsleeve are:A. An intermediate sleeve must be used for a proper seal.B. The intermediate sleeve should be sized correctly to accom-modate both belts of Link-Seal® modular seals.C. Be sure to support the actual carrier pipe properly. Neitherbelt of links should be responsible for supporting thecarrier pipe.D. Let economics guide your selection when sizing Link-Sealmodular seals. However do not undersize, refer to adjacentexample or call PSI for sizing assistance 1-800-423-2410.Intermediate SleeveWhen Link-Seal modular seals are specified for a pene-tration through a curved wall, the thickness must bechecked to assure an adequate sealing surface. A mini-mum (effective) wall thickness (Te) is required. This canbe found by a scale drawing or by using the adjacentformula.Pressure TestingTo determine the amount of pressure that has built upbehind a Link-Seal® modular seal, install our “V” modi-fication. It is a standard Link-Seal® modular sealassembly in which one link has a hole molded toaccept a test probe. The probe has a NPT female connection and is insert-ed prior to tightening the assembly. The probe is firmlysealed by expansion of the rubber link. A pressuregauge can then be attached to monitor for leaks orpressure build-up.Wall OpeningTest PressureGauge*1/4” NPTFPipe ThreadTest ProbeFurnishedby PSI* = Not Provided by PSIChamberTo Be TestedModified StandardLink-Seal modularseal with Hole forTest Probe.SleeveShut-off Valve*How To OrderPlease specify “V” with Link-Seal modular sealModel Number Example: LS-400-C-V.“V” modification NPTF is available in carbonand 304 stainless steel.Sealing Manhole PenetrationsrtcTeTe = t - (r - 1/2 4r2 - c2 Example: 3” DI Pipe = LS-315-C-10t = wall thickness ----------------- 5”r = wall outside radius ---------- 29”c = penetration opening I.D. -- 6”Link-Seal Model (Te) MinimumSelected for PenetrationLS-200/275 2.25”LS-300/315 3.00”LS-325/340/360 4.00”LS-400/410/425/475 5.00”LS-500/525/575 5.00”LS-600/650 6.00”(Te) = Required bearing surface based on the footprint ofrespective Link-Seal modular seal model.)1. Make sure pipe is cen-tered.2. Install the belt with thepressure plates evenlyspaced.3. Install the exact number22If the seal doesn’t appear to be correct using thetechniques provided, Call PSI at 713-747-6948or in Canada 902 435 9899 - 416 752 3339mailto:sales@powerplantsupplyco.comInstallation Techniques - Link-Seal® Modular SealsInstallation Notes: The Link-Seal® modular seal bolt heads are usually recessedbelow the wall opening or the edge of casing pipe and therefore a socket or offsetwrench must be used. Hand Tools: Review provided chart above. (Tools not provided.)Tools can be purchased from hardware store, auto parts store, or home improvementstore.1. Center the pipe, cableor conduit in wall openingor casing. Make sure thepipe will be adequatelysupported on both ends.Link-Seal® modular sealsare not intended to supportthe weight of the pipe.2. Loosen rear pressureplate with nut just enoughso links move freely.Connect both ends of beltaround the pipe. 3. Check to be sure all boltheads are facing theinstaller. Extra slack or sagis normal. Do not removelinks if extra slack exists.Note: On smaller diameterpipe, links may need to bestretched.4. Slide belt assembly intoannular space. For largersize belts, start insertingLink-Seal modular sealassembly at the 6 O’Clockposition and work bothsides up toward the 12O’Clock position in theannular space.5a. LS-325 thru. LS-650Using a hand socket oroff-set wrench ONLY, startat 12 O’ Clock. Do nottighten any bolt more than4 turns at a time. Continuein a clockwise manner untillinks have been uniformlycompressed. (Approx. 2 or3 rotations)5. LS-200 thru. LS-315Using a hand socket allenhead or off-set wrenchONLY, start at 12 O’ Clock.Do not tighten any boltmore than 4 turns at atime. Continue in a clock-wise manner until linkshave been uniformly com-pressed. (Approx. 2 or 3rotations)6. Make 2 or 3 more pass-es at 4 turns per bolt MAX-IMUM, tightening all boltsclockwise until all sealingelements “bulge” aroundall pressure plates. Ontype 316 stainless steelbolts, hand tighten ONLYwithout power tool.7. If the seal doesn’tappear to be correct usingthe instructions provided,Call PSI at 800-423-2410.Link-Seal® Modular Seal - Do’s Link-Seal® Modular Seal - Don’ts1. Don’t Install the belt withthe pressure plates aimedin irregular directions.(Staggered)Don’tAlways Wear Safety Equipment When Using Link-Seal® Modular SealsConnectBulgeInstallation Completeof links indicated in sizingcharts.4. Check to make sure pipeis supported properly dur-ing backfill operations.Note: Link-Seal modularseals are not intended tosupport the weight of thepipe.5. Make sure seal assem-bly and pipe surfaces arefree from dirt.6. For tight fits, use non-polluting liquid detergent toassist installation.2. Don’t Install Link-Seal®modular seals where weld-beads or other irregularsurfaces exist without con-sideration of the sealingrequirements.3. Don’t torque each boltcompletely before movingon to the next.4. Don’t use high speedpower tools (450 rpm ormore)5. Do not use power toolson Link-Seal modular seal316 stainless steel bolts.6. Don’t use greaseinstalling Link-Seal modularseals.Tool Size/ Link-Seal® Model Type Req. Bolt HeadLS-200, LS-275 4mm, AllenLS-300, LS-315 6mm, AllenLS-325, LS-340, LS-360 13mm, HexLS-400, LS-410, LS-425, LS-475 17mm, HexLS-500, LS-525, LS-575 19mm, HexLS-600 30mm, HexLS-650 19mm, Hexhttp://www.powercanadasolutions.com/linkseal.html 231. Measure the center line to position Century-Line® Sleeveend cap.2. Nail one of the end caps atthe marked center line. A 2”minimum clearance is sug-gested when nesting sleeves.3. Place the Century-Line®Sleeve on the end cap. Whenfield cutting non standard CSsleeve lengths, the sleeve andendcaps total length should beone-fourth (1/4”) longer thanthe thickness of the wall. Cutwith a hand or power saw. Note: To insure minimum watermigration, center the water stopin wall by cutting equal lengthsfrom each end of the sleeve,except as noted below.Century-Line® Sleeves are thermoplastic wall or floor pipe penetration sleeves. One person working alone can usually install a Century-Line® Sleeve regardless of the size.4. Place second end cap onsleeve. Check to determinethat the cap is properly insert-ed.5. For additional stability, it’s necessary to secure thesleeve with wire to the rebar.Insert the other end cap firmly,check that second end cap ispositioned correctly, confirmsleeve length and close theform.6. After the concrete is pouredand cured, remove end capswith screw driver or crow bar.End caps may be replaced toprotect sleeve until pipe pene-tration is made.After nailing end cap to form,drive (threaded rod*) throughthe end plate and form and(thread nut*) on other side.Note: Remember to measurethe (threaded rod*) to matchthe length of the sleeve.Place the sleeve over the endcap nailed to the form.* = Not Provided byPSI.Place second cap on thesleeve and use a (block ofwood*) and (wing nut*) to tighten unit in place. Make certain sleeve is plumb.Installation Techniques - Century-Line® SleevesAlternative Technique Using Threaded RodWall Cut From Dimension Cut From DimensionThickness Left End A Right End B16” 0.0” 7.125” 0.0” 7.125”14” .875” 6.125” .875” 6.125”12” 1.875” 5.125” 1.875” 5.125”10” 2.375” 4.625” 3.375” 3.625”8” 2.375” 4.625” 5.375” 1.625”EndCap1/2”EndCap1/2”CenterWater Stop1”A BNotes:1. Example: To convert 16” to 12”,cut 1.875” off each end.2. Endcaps leave 1/2” depressionin face of concrete.3. On sleeves under 12” length,install Link-Seal® modular seal onthe “long side” of the waterstop.(a) For Link-Seal® modular sealsmodels LS-200, LS-275, LS-300,LS-315, LS-340 and LS-360 -install with pressure plates flushwith outer edge of the sleeve.(b) For Link-Seal® modular sealsmodels LS-325, LS-400, LS-410,LS-425 and LS-475 - install withpressure plates partially insertedinto the sleeve. When tightened,the pressure plates will “pull” intothe sleeve.(c) For Link-Seal® modular sealsmodels LS-500, LS-525, LS-575,LS-600 and LS-650 - the minimumsleeve length is 10”. Follow theinstructions in 3 above.1/2”Depression in face of the con-crete formed by the endcaps.If you should have questionsusing the techniques provided,Call PSI at 713-747-6948 In Canadasales@powerplantsupplyco.comAlways Wear Safety Equipment When UsingCentury-Line Sleeves & Link-Seal Modular SealsAlways install Link-Sealmodular seals on side Ahttp://www.powercanadasolutions.com/linkseal.html 24Installation Techniques - Cell-Cast® Disks1. Locate center line wherethe hole is desired. This loca-tion will be used as a guide forthe threaded centering assistrod.2. A 2x4 wood nailer is includ-ed. Fasten it along with thethreaded rod directly to theconcrete form. This providessupport and helps center thecomplete Cell-Cast® diskassembly.4. Secure the edges of the cellto the form using the providedsteel spikes.3. Slide the first Cell-Cast®disk over the *threaded rod.Note: Use only 1 threaded rodfor equal distribution. Morethan one rod could take disksout of shape. 6. Guide the 1” wood blockover the threaded rod andsecure the assembly with thewing nut provided.8. After wall cures, wall formsare removed. The Cell-Cast®disk assembly is now ready forremoval.9. Chip excess concrete fromthe edge of the Cell-Cast® diskassembly and wall.7. Wrap each seam with onewrap of 2” wide tape to bridgeany possible gaps. Note: Tapenot included. Finish installingconcrete forms and pour con-crete.10. Remove disks by breakingout the entire assembly.11. Inspect the installation. Asmooth opening is importantfor a proper Link-Seal®modular seal installation.Repair voids and grind smoothany ridges.Always Wear Safety Equipment When Using Cell-Cast® Disks5. Additional disks are inter-locked to accommodate fin-ished wall thickness. Verifythickness is the same as wall.If you should have questionsusing the techniques provided,Call PSI at 713-747-6948 or Canada:sales@powerplantsupplyco.comNote: For walls greater than 16”,please contact PSI.*Note: Threaded rod must berequested when ordered. Makesure TRA is added to the end ofthe ordering code.25LINK-SEAL® MODEL NO. EXAMPLELS - 400 - C - 10LINK-SEAL®SIZEMODELNO. OF LINKSELASTOMERIC SEAL ELEMENTLS MODEL(C, L, S-316, LS-316, S61,O, OS-316, T)BOLTPRESSURE PLATECENTURY-LINE® SLEEVEWALLANCHOR COLLAR/WATER STOPCENTURY-LINE® MODEL NO. EXAMPLECS - 10 - 16 - 1CS SLEEVE MODEL NO.SLEEVE LENGTH (INCHES)NO. OF UNITSELASTOMERIC SEAL ELEMENTLS MODEL(C, L, S-316, LS-316, S61,O, OS-316, T)BOLTPRESSURE PLATESTEEL WALL SLEEVEWALLANCHOR COLLAR/WATER STOPSTEEL WS SLEEVE MODEL NO. EXAMPLEWS - 14 - 25 - S - 12WALL SLEEVESLEEVE NOMINALSTEEL WALL THICKNESSSTEELLENGTH IN INCHESELASTOMERIC SEAL ELEMENTLS MODEL(C, L, S-316, LS-316, S61,O, OS-316, T)BOLTPRESSURE PLATECORED/DRILLED HOLEWALLProduct Ordering CodeLink-Seal® Modular Seals with Century-Line SleevesLink-Seal® Modular Seals with Model WS Wall SleevesLink-Seal® Modular Seals with Cast, Core Drilled orCell-Cast® Disk Wall OpeningCAD (.dwg) Drawings In Canada ContactVisit www.powercanadasolutions.comLINK-SEAL® MODEL NO. EXAMPLELS - 400 - C - 10LINK-SEAL®SIZEMODELNO. OF LINKSLINK-SEAL® MODEL NO. EXAMPLELS - 400 - C - 10LINK-SEAL®SIZEMODELNO. OF LINKSCELL-CAST DISK ® MODEL NO. EXAMPLECC - 30 - (3)2 - (4)2CELL-CAST® MODEL NO.NO. 3” DisksNO. 4” DisksNote: Creating a 30” (29.25” I.D.) Hole with a 14” WallThickness. Specify TRA at the end of the ordering code forthreaded rod assembly.B. Models LS200-275-300-315 shall incorporate the most cur-rent Link-Seal® Modular Seal design modifications and shallinclude an integrally molded compression assist boss on thetop (bolt entry side) of the pressure plate, which permitsincreased compressive loading of the rubber sealing element.Models 325-340-360-400-410-425-475-500-525-575-600 shallincorporate an integral recess known as a “Hex Nut Interlock”designed to accommodate commercially available fastenersto insure proper thread engagement for the class and serviceof metal hardware. All pressure plates shall have a perma-nent identification of the manufacturer’s name molded into it.C. For fire and Hi-Temp service, pressure plates shall be steelwith 2-part Zinc Dichromate Coating.2.2 Link-Seal® Modular Seal HardwareAll fasteners shall be sized according to latest Link-Seal® modu-lar seal technical data. Bolts, allen head/flange hex nuts shall beeither:A. Mild Steel with a 60,000 psi minimum tensile strength and 2-part Zinc Dichromate coating per ASTM B-633 and OrganicCoating, tested in accordance with ASTM B-117 to pass a1,470 hour salt spray test.B. 316 Stainless Steel per ASTM F593-95, with a 85,000 psiaverage tensile strength.3.0 Wall OpeningA. Century-Line® Sleeves - for openings to 24.75” diameter.Where pipes must pass through walls and floors of new struc-tures, unless otherwise shown or specified, installmolded non-metallic high density polyethylene Model CSCentury-Line® sleeves as manufactured by PSI-Thunderline/Link-Seal®. Model CS sleeves shall have inte-grally formed hollow water stop sized having a minimum offour inches larger than the outside diameter of the sleeveitself and allowing 1/2” movement between wall forms toresist pour forces. Each sleeve assembly shall have endcaps manufactured of the same material as the sleeve itselfand installed at each end of the sleeve so as to preventdeformation during the initial concrete pour, and to facilitateattaching the sleeve to the wall forms. End caps shall remainin place to protect the opening from residual debris androdent entry prior to pipe insertion.B. Cell-Cast® Disks - for openings from 29.25” to64.74” diameter. The contractor shall install Cell-Cast® disks, providing a roundhole in conformance with Link-Seal® modular seal sizing data.Cell-Cast® disks shall consist of 3” and/or 4” lightweight inter-locking polyethylene cells stacked to form the thickness of thepoured concrete wall. Molded into each cell shall be a cavityto accept a 2” x 4” nailer. 4.0 Quality AssuranceLink-Seal® Modular Seal components and systems shall bedomestically manufactured at a plant with a currentISO 9001:2008 registration. Copy of ISO 9001:2008registrations shall be a submittal item. NOTE: Link-Seal Modular Seals are specifically designed ashydrostatic and/or fire rated seals and are not considered to be pipesupports. When appropriate, Link-Seal Modular Seals should be usedwith proper pipe supports on both ends.Typical Specification1.0 GeneralUnder this section there shall be furnished and installed acomplete Link-Seal® modular seal assembly, manufactured byPSI-Thunderline/Link-Seal® located at 6525 Goforth Street,Houston, TX 77021, as shown on drawings and specifications.For clarification, complete assembly is defined as a combined:A. Wall (Floor, Ceiling) opening (i.e. steel sleeve, Thermoplastic(HDPE) sleeve, cored hole or formed hole). The wall openingsize and/or type shall be selected according to informationfound in the most recent Link-Seal® modular seal catalog.B. Sufficient quantity and type of Link-Seal® modular sealsrequired to effectively provide a hydrostatic and/or fire-ratedseal. C. Each individual link shall be conspicuously and permanentlyidentified with the name of the manufacturer and model num-ber. Manufacturers other than the above-named companywishing to quote equipment in this section shall submit detaildrawings of their proposed equipment and suitable evidenceof a minimum of 25 years of experience and results to theengineer to obtain written approval to quote at least ten (10)days prior to bid opening.2.0 Link-Seal® Modular Seal Rubber LinksShall be modular, mechanical type, consisting of inter-lockingsynthetic rubber links shaped to continuously fill the annularspace between the pipe and the wall opening. The elastomericelement shall be sized and selected per manufacturer’s sizingprocedure and have the following properties as designated byASTM. Coloration shall be throughout elastomer for positivefield inspection. Each link shall have a permanent identificationof the size and manufacturer’s name molded into it.A. For Standard Service Applications = Model C-40 to +250ºF (-40 to +121ºC)EPDM = ATSM D2000 M3 BA510 Color = BlackB. For Potable Water/NSF 61 Service Applications = Model S61-40 to +250ºF (-40 to +121ºC)EPDM = ATSM D2000 M3 BA510 Color = BlackC. For Thin Walled Pipe Applications = Model L-40 to +250ºF (-40 to +121ºC)EPDM = ATSM D2000 M3 BA510 Color = BlueD. For Hydrocarbon Service Applications = Model O-40 to +210ºF (-40 to +99ºC)Nitrile = ASTM D2000 M1BF510 Color = GreenE. For High Temperature or Fire Seal Applications = Model T-67 to +400ºF (-55 to +204ºC)Silicone = ASTM D2000 M1GE505 Color = GrayReference shall always be made to the latest publishedLink-Seal® modular seal selection guide for the serviceintended.2.1 Link-Seal® Modular Seal Pressure PlatesA. Link-Seal® modular seal pressure plates shall be a uniformpressure plate design molded of glass reinforced NylonPolymer with the following properties:Izod Impact - Notched = 2.05ft-lb/in. per ASTM D-256Flexural Strength @ Yield = 30,750 psi per ASTM D-790Flexural Modulus = 1,124,000 psi per ASTM D-790Elongation Break = 11.07% per ASTM D-638Specific Gravity = 1.38 per ASTM D-792Typical Specification261) Q - Can Link-Seal® modu-lar seals be used with pipetypes not listed in the stan-dard published charts?A - Yes, The best way to per-manently seal any cylindricalobject, of any size, passingthrough any type of concretebarrier?is to use Link-Sealmodular seals. From ductileiron to pre-stressed concreteto metal or plastic pipe, con-duit or cables - whatever yourapplication - Link-Seal modu-lar seals will effect a hydro-static seal capable of holding20 psig (40 feet of static head)between the pipe and the pen-etration cylinder through whichthe pipe passes.2) Q - How much angularpipe movement will Link-Seal® modular seals allowand still maintain a seal?A - Link-Seal modular sealsmay allow angular pipe move-ment or misalignmentdepending on the ratio ofannular space of the penetra-tion to the expanded range ofthe Link-Seal model sized forthe penetration. Please callPSI for more information.3) Q - When is the recom-mended time to install Link-Seal® modular seals?A - Always install Link-Sealmodular seals prior to any finalconnections. This helps pre-vent off-center pipe alignment.4) Q - Is it necessary to useWS or CS sleeves wheninstalling Link-Seal® modularseals?A - WS model steel and CSmodel HDPE sleeves are spe-cially designed for use withLink-Seal modular seals. Wheninstalled with Link-Seal modu-lar seals these sleeves pro-vide the best possible assur-ance of a quality wall penetra-tion system.5) Q - What tools arerequired to install Link-Seal®modular seals?A - A low speed (450 RPM orless) power tool is suggestedfor multiple installations toincrease efficiency with carbonsteel hardware.6) Q - Can I use power toolswhen installing Link-Sealmodular seals with 316stainless steel bolts?A - No, please refer to sug-gested installation techniques.7) Q - Sometimes wheninstalling a Link-Seal® modu-lar seal belt, it hangs looseon the pipe even though allmy sizing calculations arecorrect. Why does it appearthat I have too many links?A - Link-Seal modular sealsare basically sized to fit theannular space, not the pipe.Use the assemblies suggestedby the charts or calculation. Itmay not look right, but it willfit.8) Q - Can Link-Seal® modu-lar seals be used for pene-trations where the pipe isoff-center to the opening?A - Centering is very impor-tant. Contact PSI for moreinformation.9) Q - How do I install Link-Seal® modular seals over aweld-bead?A - Weld-beads and all otherirregularities on the pipe oropening should be addressedin accordance with the manu-facturer’s and/or project engi-neer’s suggestions to providea round, smooth and cleansurface for Link-Seal installation.10) Q - My wall is 24” thick.Do I need Link-Seal® modu-lar seals on both sides ofthe wall?A - In many cases, one singleLink-Seal modular sealassembly is appropriate.Double seals are typicallyfound in critical applicationssuch as fire walls or nuclearpower stations. Double sealsare also suggested for buildingfoundation wall penetrationswhere the wall thickness isgreater than 12”.11) Q- Can Link-Seal® modu-lar seals be used with man-hole vault installed thimbles,not sleeves?A- No, only if the area createsa penetration cylinder, suchthat the axis of the cylinder is parallel to the axis of the pipegoing through it.12) Q- Can lubricant be usedto install Link-Seal® modularseals?A- Yes, any non-polluting liq-uid detergent is preferred overa grease. If you need to usegrease or another lubricant,please contact PSI.13) Should you grout overLink-Seal® modular seals?A- Link-Seal modular seals donot require any assistance tocreate a water tight seal, ifthey are installed per our pub-lished installation techniques.Any material placed betweenthe seal and the ID of the pen-etration is not recommended.However, if grout is needed forappearance purposes only, it’ssuggested that the links beinstalled far enough into thepenetration to accommodate alayer of “bubble wrap”. If thepipe needs future mainte-nance the grout can beremoved and access can begained to the bolts of the Link-Seal modular seal.14) What model Link-Seal®modular seals should beused for submerged seawater applications?A- For submerged sea waterapplications use Model S-316Link-Seal® modular seals. Seepage 5 for material propertyinformation.15) Why is it sometimes dif-ficult to seal an insulatedpipe with Link-Seal® modularseals?A- Jacket thickness, or moreimportantly, its ability to main-tain its diameter withoutdeforming is key to success ofthe Link-Seal® modular seal’sability to seal. If the jacketwithstands the constrictingforce of the Link-Seal modularseal without cracking ordeforming, Link-Seal modularseals are effective. If the jack-et “gives”, much like an alu-minum can, the jacket willcrack enabling water to godirectly into the insulation andby pass the Link-Seal modularseal installation.16) Q - Is it necessary to useriser clamps, pipe saddlesand hanger supports withLink-Seal® modular seals?A - Link-Seal modular sealsare penetration type seals. It isnot intended to be a structuralsupport. Standard pipe hangerpractice should always beapplied.17) Q – Why are torque val-ues not used to install Link-Seal® Modular Seals?A –Every penetration hasunique parameters; OD, ID,surface smoothness, ratios ofannular space to expandedrange. Follow Step #6 in thePublished InstallationTechniques for properinstallation.Frequently Asked QuestionsUpdated engineering catalogs, literature, CAD Drawings, submittals andinstallation techniques are available on-line at: www.linkseal.com27Link-Seal® ModelTool Size/Type Req.LS-200, LS-275 4mm, AllenLS-300, LS-315 6mm, AllenLS-325, LS-340, LS-360 13mm, HexLS-400, LS-410,LS-425, LS-475 17mm, HexLS-500, LS-525, LS-575 19mm, HexLS-600 30mm, HexLS-650 19mm, HexPipeline Seal and Insulator, Inc.6525 Goforth Street, Houston, TX 77021 U.S.A.Telephone: 713-747-6948, Facsimile: 713-747-6029 In Canada contact:www.powercanadasolutions.com, e-mail sales@powerplantsupplyco.comLink-Seal® is a registered trademark of PSI.Century-Line® is a registered trademark of PSI.Cell-Cast® is a registered trademark of PSI.©2011, Pipeline Seal and Insulator, Inc.LSEM/06/11Certificate No. 10125316 StainlessSteel Bolt/NutCentury-Line®Sleeve (HDPE)Century-Line®Sleeve NailerEnd CapsWater Stop Collar(Weep Ring)CarbonSteel-ZincDichromateProprietaryCoating Bolt/NutSteel-ZincDichromateHigh-TempPressure Plate Reinforced NylonPolymer PressurePlateSiliconeNitrileLS-400-TLS-400-OLS-400-CLS-400-LEPDMEPDM(Low Durometer)Seal ElementsCalling-out the OriginalLink-Seal® Modular Seal System.The System is the SolutionWarranty and Conditions of SaleThe seller warrants that all goods furnished under this order will be free from defects in material and workmanship and will con-form to Pipeline Seal & Insulator, Inc. published specifications.The limit of Pipeline Seal & Insulator, Inc.’s liability for failure of any of our products to meet the foregoing warranty, or forbreach of any other warranty, express, implied or statutory, shall be to supply an equivalent amount of product for any materialsreturned to us within 12 months of shipment and found to be defective by Pipeline Seal & Insulator, Inc.Due to the widely varying conditions under which our products are used or installed, Pipeline Seal & Insulator, Inc. offers nowarranty as to their merchantability, length of service or suitability for any particular purpose, express or implied, other thandescribed above.The Purchaser accepts full responsibility for installation of all goods furnished under this order and forany defects or damage suffered as a result of defective installation of such goods. No instructions, advice,or aid relative to installation given by the Seller to the Purchaser shall be construed as a warranty as to theaccuracy or utility of such instructions, advice, or aid, but only as an accommodation to the Purchaser andan opinion of the Seller.The foregoing conditions of sale shall not be modified or affected in any way whatsoever by reason ofSeller’s receipt or acknowledgement of Buyer’s purchase order or any other related instrument of papercontaining additional or different conditions and, to the extent there may be any terms or provisions in sucha purchase order, etc. which may be in conflict with or modification of the foregoing, such terms and provi-sions of such purchase order, etc. shall be deemed to have no force or effect.Tighten Your SpecificationsApprovals: . . .ISO 9001:2008, Factory Mutual, NSF 61Elastomers: . . . . . . . . . . . . . . . .EPDM, Nitrile, SiliconeMade in America (U.S.A) . . . . . . . . . . . . . . . . . . . . .YesPermanent Identification . . . . . . . . . . . . . . . . . . . . . .YesCorrosion Resistant Fasteners316 Stainless as Standard . . . . . . . . . . . . . . . .Yes16 Model Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . .YesHi/Low Temp. Seals . . . . . . . . . . . . . . . . . . . . . . . . .YesFM Approved Fire Seals, NSF 61 Certified . . . . . . .YesBolts available in Metric Format . . . . . . . . . . . . . . . .YesBolts pass 1470 hour salt spray test . . . . . . . . . . . .YesNon-conductive CS MoldedSleeve Penetration System . . . . . . . . . . . . . . .YesLow torque Pressure Plate and Elastomer . . . . . . . .YesSpecial “V” Modification Pressure Monitoring . . . . .YesColor Coded Elastomers and Pressure Plates . . . . .YesCell-Cast® Hole Forms . . . . . . . . . . . . . . . . . . . . . . .YesOn Staff Seal Engineering Assistance . . . . . . . . . . .YesWorldwide Stocking Distributors . . . . . . . . . . . . . . . .YesBolt and Nut Specifications per ASTM Standards . .YesUniversal Pressure Plate Design . . . . . . . . . . . . . . .Yes(See Link-Seal® Modular Sealspecification,section 2.2, on page 26)Pocket Guides - For the contractorin the field. Contact your localdistributor for printed material.http://www.powercanadasolutions.com/linkseal.html
Most popular related searches