Digmesa AG

EPI PEEK

D A T A S H E E TDigmesa AG, Keltenstrasse 31, CH–2563 Ipsach / SwitzerlandPhone +41 (32) 332 77 77, Fax +41 (32) 332 77 88www.digmesa.com Version 01 EPI 930-0201/V01 GB Page 1-5E P I P E E KPa r t n u m b e r : 9 3 0 - 0 2 0 1 / V 0 1Digmesa AG, Keltenstrasse 31, CH–2563 Ipsach / Switzerland, Phone +41 (32) 332 77 77, Fax +41 (32) 332 77 88, www.digmesa.comWe reserve the right to make modifications in the interests of technical progress . Version 01 EPI 930-0201/V01 GB Page 2-5General Description4660 7157214x 4.5883.549 without plug socket182x G1/4" 11mm depthDüse 768The EPI flowmeter is specifically suitable for fluid flow rate measurement of highly viscose media such as syrup, oil or detergent concentrates. Thanks to its special design and the epicycloid wheels, the EPI flowmeter is highly precise and allows extremely accurate flow measurement with minimal pressure loss.Included in the delivery:3-pin solenoid socketItem number: 941-0002/3Specific applications: Highly viscous media, high temperatures, high flow rates with low pres-sure loss and good chemical resistance.Material:Housing: PEEK 150 GL 30 naturBearing pin: Inox 1.4435 Aluminium oxide on requestO-ring: FPM (Viton) EPDM on requestTurbine: PEEKMagnets: NdFeB (Neodym) (not in contact with the medium)Technical data:Flow rate: 0.06 - 16.0 l/min depending on viscosityMeasuring accuracy: +/- 1.0% depending on viscosityRepetition: <+/- 0.25%Temperature range: -10°C to +65°C 14°F to 149°FPressure range: 10 bar at 20°C 145 psi /68°FMounting position: Horizontal recommendedNozzle size: Ø 7.0 mmViscosity range: approx. 5 - 8000 centistokesDimensions in mm:Electrical connection ratings:Power supply: 4.5–24 V DCConsumption: 5 mA to max. 13 mASignal connection: Open collector NPNSignal voltage: 0 V GNDSignal load: max. 20 mALeakage current: max. 10 µAConnections: 3-pin AMP 2.8 x 0.8 mmSignal: Square-wave outputDuty Cycle: 50% / ±3% Special regulations which must be complied with by the flowmeter manufacturer apply to each coun-try, e.g. CE, NSF, FDA and SK. The various media flowing through the flowmeter differ from applica-tion to application. You are advised to enquire with the medium manufacturer as to whether the entire installation and the flowmeter are resistant to the medium itself (see Material)RESISTANCEDIGMESA electronic circuitry is always designed for operation with DIGMESA flowmeters. Please note the following if connecting to other elec-tronic circuitry:•The flowmeter does not supply an output voltage but switches the signal terminal to 0 V ground (actuated) or leaves it open (non-actuated)•There must be a pull-up resistor between power supply + and signal depending on electronic circuitryELECTRONICApprovals / StandardsEN55014-1:00+A1:01+A2:02, EN61000-6-3:01+A11:04 , IEC61000-6-3:06(ed.2.0), EN61000-3-2:06, IEC61000-3-2:05(ed.3.0), EN61000-3-3:95+A1:01+A2:05, IEC61000-3-3:94+A1:01+A2:05(Cons.ed 1.2), EN55014-2:97+A1:01, EN61000-6-1:01, IEC61000-6-1:05(ed.2)Digmesa AG, Keltenstrasse 31, CH–2563 Ipsach / Switzerland, Phone +41 (32) 332 77 77, Fax +41 (32) 332 77 88, www.digmesa.comWe reserve the right to make modifications in the interests of technical progress . Version 01 EPI 930-0201/V01 GB Page 3-5Interface Connection: Examples Open CollectorSignal+Rx100nFSignal0 VDC+4.5 - 24 VDC+5 VDC4k7+ 5 VDC Rx=1k0+12 VDC Rx=4k7+24 VDC Rx=10koptocoupler interface0 VDCopen collectorSignal++4.5 - 24 VDC4k7100nFSignal0 VDCsimple circuitopen collectorSignal++4.5 - 24 VDC2k2100nFSignal0 VDC+5 VDC1N41481N4148TTL outputopen collectorDigmesa AG, Keltenstrasse 31, CH–2563 Ipsach / Switzerland, Phone +41 (32) 332 77 77, Fax +41 (32) 332 77 88, www.digmesa.comWe reserve the right to make modifications in the interests of technical progress . Version 01 EPI 930-0201/V01 GB Page 4-5Measurement Curve EPI Ø7.00 mmThe values specified must be considered as approximate values.The number of pulses per litre may differ depending on medium and installation.We recommend to calibrate the number of pulses per litre in line with the complete installation.Nozzle size Pulses/litre g/pulse min. flow rate max. flow rate Pressure loss in litres/min at in litres/min Linear start Ø 7.00 mm 462 2.166 0.0653 5.35 0.29? ??? ? ??? ? ??? ? ??? ? ??? ? ???'XUFKIOXVV?IORZ?UDWH?O?PLQ??????????$EZHLFKXQJ?GHYLDWLRQ??/LQHDULWlW?OLQHDULW\\? ??? ? ??? ? ??? ? ??? ? ??? ? ???'XUFKIOXVV?IORZ?UDWH?O?PLQ??????????'UXFNYHUOXVW?SUHVVXUH?GURS?EDU'UXFNYHUOXVW?SUHVVXUH?GURSMedium for these linearity and pressure loss curves: Cola syrup (approx. 24 centistokes). The min. and max. flow rate and the pressure loss may vary depending on viscosity.• Ensure that there is no fast-pulsatory movement of the media• Ensure that there are no reverse pressure surges• Ensure that there is no air in the system• Note the mounting position of the flowmeter• Min/max flow should be in the linear range of the selected flowmeter• Clean the system at appropriate intervals• Avoid electrical current peaks• Incorrect cabling of power supply +, signal and ground will destroy the flowmeter• Do not mechanically load electrical contacts• Avoid moisture on the electrical contacts• Avoid stray pick-up via the cable (Do not lay cables in parallel with high current loads)MEASUREMENT TIPSDigmesa AG, Keltenstrasse 31, CH–2563 Ipsach / Switzerland, Phone +41 (32) 332 77 77, Fax +41 (32) 332 77 88, www.digmesa.comWe reserve the right to make modifications in the interests of technical progress . Version 01 EPI 930-0201/V01 GB Page 5-5Spare parts:PT screws # 442-0320Upper section EPI PEEK # 530-0201O-ring FPM (Viton) # 350-0931Turbine EPI 0° # 527-0901Lower section EPI PEEK # 514-5201 Notes:Turbine EPI 5.6° # 527-0902
Most popular related searches