DMG Control Systems Ltd.

Eurotherm - Model 3216 - Temperature/Process Controller - Brochure

The new 3216 1/16th DIN controller provides a new level of userconvenience. The scrolling text messages deliver plain languagemessages to let operators and engineers alike know exactly whatis happening to the process.The Quick Start Wizard makes configuration simpler than ever.At initial power up the configuration is displayed on the lowerdisplay. Universal inputs enable the simple selection of any standardthermocouple, Resistance Thermometer or process input. Acustom linearisation can be installed using the simple PC tool,iTools.Timer functions offer the choice of : a dwell timer; a delayedswitch on timer or a self start timer.Three outputs can be configured to provide any combination ofheating, cooling and alarm.The Load Current Transformer Input, CT input, provides theideal method to monitor load current and provide immediateindication of load conditions. Partial load failure, heater opencircuit or thyristor short circuit can each be indicated by clearscrolling operator messages and relay output.The operator interface is fully configurable enabling anyparameter to be promoted for immediate operator access onlevel 1 or password protected level 2. This provides for thesimplest solutions right through to sophisticated applications.The new three colour LCD display provides clear indication ofprocess variables. The upper display shows the process measuredvalue while the lower display can be set to display a range ofparameters including, setpoint, time remaining and current.The communications option provides full system integrationthrough the industry standard modbus protocol.Rear terminal connections3216MODELTemperature/Process ControllerIdeal for:? plastic extruders? small ovens ? chillers? sterilisers? trace heating? packaging machines Specifications:Dimensions:48W x 48H x 90D mmText messages:10 x 30 character messages Control modes: PID or On/Off, heat/cool, heat only, cool onlySupply voltages: 85-264Vac, 24Vac/dc6 watts max.Operating ambient: 0 to 50 deg C5% to 85% RH, non condensingInputs:ThermocouplesPt100 3 wire0-50mV, 4-20mA, 0-20mACustom linearisationCurrent transformer input:50mA ac into 10RCommunications:Modbus, RS232, RS485 2 wireOutput ratings: Relay: 2A, 264Vac resistiveLogic out: 12VdcDigital in: contact closure orlogicPanel sealing: IP65, plug-in from front panel • DATA MANAGEMENT • CONTROLS • PROCESS AUTOMATION• AAABVIV+V-mV/VACCOMA(+) B(-)199 to 240Vac 50/60 Hzor 24 Vac/dcHEHFCTCHDLAmA1A1B2BLN2ANOC+-NOC+-CTOP1OP2OPAEUROTHERM LIMITED UK EUROTHERM US Faraday Close Durrington Worthing BN13 3PL United Kingdom 741-F Miller Drive Leesburg VA 20175-8993Tel. +44 (0)1903 205277 Fax +44 (0)1903 236465 Tel. 1-703-443-0000 Fax 1-703-669-1300Email info@eurotherm.co.uk Email info@eurotherm.comWeb www.eurotherm.co.uk Web www.eurotherm.com© Copyright Eurotherm Limited 2003All rights are strictly reserved. No part of this document may be reproduced, modified, or transmitted in any form by any means, nor may it be stored in a retrieval system other than for the purpose to act as anaid in operating the equipment to which the document relates, without the prior written permission of Eurotherm limited.Eurotherm Limited pursues a policy of continuous development and product improvement. The specifications in this document may therefore be changed without notice. The information in this document isgiven in good faith, but is intended for guidance only. Eurotherm Limited will accept no responsibility for any losses arising from errors in this document.Part No. HA028002 Issue 1 3216 Data sheet Printed in England 04.03CodingVH 110-240VVL 20-29VFascia ColourG GreenS SilverInput/output 1 & Output 2 Power SupplyI/OP1 OP2L X Logic Input/outputL L Logic input/output + logic outputL R Logic input/output + Relay R R Relay + RelayX X Not fitted3216 CCModelNumberPower SupplyInput/output 1 & Output 2XXOutput A Communications, CT & Digital InputFasciaColourLanguageOptionalQuickStart CodeHardware coding only LanguageENG EnglishCommunications, CT & Digital InputX X X Not fitted4 X X RS485 comms (2 wire)2 X X RS232 comms 4 C L RS485 comms, CT and Digital input2 C L RS232 comms, CT and Digital inputX X L Digital input onlyX C L CT and Digital inputQuick Start CodeSee below3216, Controller, 110 - 240V supply, Logic andRelay output, Relay output, RS232, CT and Digitalinput, green fascia, English manualExample ordering code3216 - CC - VH - LR - XX - R - 2CL - G - ENG Output AR Relay (form C)0 Not fittedInput TypeInputTypeSetpointLimitsOP1 OP2 OPAOptional Quick Start Code - Part 1 ThermocoupleB Type BJ Type JK Type KL Type LN Type NR Type RS Type ST Type TC Custom/Type CRTDP pt100Linear †M 0-50mV2 0-20mA4 4-20mASetpoint LimitsTemperatureC Deg C full rangeF Deg F full rangeCentigrade0 0 to 100 deg C1 0 to 200 deg C2 0 to 400 deg C3 0 to 600 deg C4 0 to 800 deg C5 0 to 1000 deg C6 0 to 1200 deg C7 0 to 1400 deg C8 0 to 1600 deg C9 0 to 1800 deg COP1ControlH Heat (PID)C Cool (PID)J Heat (On/off)K Cool (On/off)Alarm output enegised in alarm0 High alarm1 Low alarm2 Deviation high3 Deviation low4 Deviation bandAlarm output de-enegised in alarm5 High alarm6 Low alarm7 Deviation high8 Deviation low9 Deviation bandLogic inputL KeylockM ManualR Run/holdW Acknowledge alarmP Setpoint 2T ResetX Not fittedOP2ControlH Heat (PID)C Cool (PID)J Heat (On/off)K Cool (On/off)Alarm output enegised in alarm0 High alarm1 Low alarm2 Deviation high3 Deviation low4 Deviation bandAlarm output de-enegised in alarm5 High alarm6 Low alarm7 Deviation high8 Deviation low9 Deviation bandX Not fittedOP4ControlH Heat (PID)C Cool (PID)J Heat (On/off)K Cool (On/off)Alarm output enegised in alarm0 High alarm1 Low alarm2 Deviation high3 Deviation low4 Deviation bandAlarm output de-enegised in alarm5 High alarm6 Low alarm7 Deviation high8 Deviation low9 Deviation bandX Not fittedNotes:Alarms are numbered leftto right.The first alarm output willbe number one.† Linear current inputs usean external 2.49ohm, 1%current sense resistor.X XInputCT ScaledInputLogicLowerDisplayQuick Start Code - Part 2 1 10 Amps2 25 Amps5 50 Amps6 100 AmpsX Not fittedInput CT ScaledL KeylockM ManualR Run/holdW Acknowledge alarmP Setpoint 2T ResetX Not fittedInput LogicT SetpointP Output power %R Time to runE Elapsed time1 AI1 SetpointA AmpsN NoneLower DisplayNote:The current transformerinput (CT) will be attachedto the first HeatingChannelFahrenheitG 32 to 212 deg FH 32 to 392 deg FJ 32 to 752 deg FK 32 to 1112 deg FL 32 to 1472 deg FM 32 to 1832 deg FN 32 to 2192 deg FP 32 to 2552 deg FR 32 to 2912 deg FT 32 to 3272 deg F
Most popular related searches