Bieler Lang GmbH

ExDetector HC 150-K Data sheet

Gas Detection and Warning SystemsExDetector HC 150ExDetector HC 150-KData SheetPage 2 Technical Status: 11/2010Gas DetectorData SheetExDetector HC 150 / HC 150-KApplications/ Set-upProduct Features ? Detection of combustible gases and vapours in air? Measurement range: 0 ... 100 % LEL? Measurement principle: catalytic combustion? Linear measurement signal 4 ... 20 mA? One-man calibration? Suitable for areas where there is a Zone 2 explosion hazard? Models available:- HC150:Standard, for wall mountingThe gas detector ExDetector HC150 in combination with an evaluationsystem has the following functions:? Measurement and display of the current concentration of potentiallyexplosive gases and vapours? Monitoring these gases and warning of their presence? Triggering protective measures:- Technical: measures to prevent the concentration increasing (fans;switching equipment off ...).- Organisational: optical and acoustic signals.A gas warning installation consists of the following components:? A sensor? An evaluation system? Controllable devices such as fans, illuminated warning signs, andsolenoid valvesControlerDetectorHow It Works The detector electronics regulate the operating parameter (heating voltage) ofthe sensor. The sensor is made up of active and an inactive elements. Theinactive and active sensor elements are connected together in a Wheatstone’sbridge circuit to compensate for environmental influences, such as variationsin the ambient temperature. As soon as combustible gases reach the activesensor, combustion of the measurement gas occurs. The heat of this reactionchanges the electrical resistance and thus the bridge signal. The resultant,small voltage signals are processed and converted to a 4 ... 20 mAmeasurement signal.- HC150-K:For installation in ventilationducts Technical Status: 11/2010 Page 3Gas DetectorData SheetExDetector HC 150 / HC 150-KCircuit Block Diagram1) The useful life of a catalytic combustion sensor is affected by what areknown as catalyst poisons. These substances include sulphur, phosphorus,silicon and lead compounds. Corrosive substances which liberate chlorine orfluorine compounds during reactions at the sensor element also reduce theanticipated working life, normally > 3 years.Technical Data ExDetector HC 150 ExDetector HC 150-KATEX designation II 3 GEx nA de IIC T4Certificate ofconformity PTB 10 ATEX 1023Field of use Zone 2 hazardous areasCategory 3Equipment group IIAtmosphere GApplication Wall-mounting Ventilation ductmountingDetectable gases Combustible gases and vapours 1)Measurement range 0 ... 100 % LELMeasurement principle Catalytic combustion (heat of reaction)Response time T90 Depends on gas detected (typically < 30 sec)Max. flow speed 6 m/secTemperature range -20 °C ... +55°CHousing:-20 °C ... +55°CSensor:-20 °C ... +80°CAir pressure range 800 ... 1100 hPaHumidity range 20 ... 90 % rel. humidityStorage conditionsTemperature: -25°C to 60°CAir pressure: 800 hPa to 1100 hPaHumidity: 20% r.h. to 90% r.h.Field interface 4 ... 20 mASupply voltage (atsensor terminals)18 ... 28 VDC SELV / PELVexternal 100 mAT series fuse requiredMax. cable length 1000 m (screened cable)Suitable evaluationdeviceGas detection computersGMC 8022,GMC 8022E,GMC 8364 orGMC 8420Page 4 Technical Status: 11/2010Gas DetectorData SheetExDetector HC 150 / HC 150-KMechanical Data ExDetector HC 150 ExDetector HC 150-KDegree of protection(housing) IP54Housing materials Sensor: stainless steelHousing: aluminiumWeight ca. 600 gr ca. 1600 grCable gland Cable gland fitting forcable diameter 6... 10 mmConnection terminals 0.5 ... 2.5 mm2 (without end sleeve)0.5 ... 1.5 mm2 (with end sleeve)240 mm125 mm105 mm75 mm150 mm105 mm75 mm105 mm75 mmd=11 mmd=30,3 mmExdetector HC 150Exdetector HC 150-K Technical Status: 11/2010 Page 5Gas DetectorData SheetExDetector HC 150 / HC 150-KAccessories ? Test gas set? Calibration gasesEverything from a single supplier - from system design to installation of yournew gas warning system. This is backed up with comprehensive coverage byour sales and service network. Ask us about regional representatives in yourarea. And after purchase our service technicians are ready and willing tohelp and advise.ServicePage 6 Technical Status: 11/2010Gas DetectorData SheetExDetector HC 150 / HC 150-KBieler + Lang GmbHGas Detection and Warning SystemsPO Box 1129, D-77842 AchernOberkirchstr. 19-21, D-77855 AchernTelephone +49 (0) 78 41 69 37 - 0Telefax +49 (0) 78 41 69 37 - 99E-mail info@bieler-lang.deInternet www.bieler-lang.de We reserve the right to make technical changes
Most popular related searches