Electrolab Biotech Limited
  1. Companies & Suppliers
  2. Electrolab Biotech Limited
  3. Downloads
  4. FerMac - 368 - Gas Analyser Technical ...

FerMac - 368 - Gas Analyser Technical Specification

Technical InformationFerMac 368Gas Analyser Electrolab Biotech LimitedUnit E2, Northway Trading EstateTewkesbury, Glos GL20 8JH, UKTel: +44 1684 291007Fax: +44 1684 291006Email: sales@electrolabtech.co.ukFERMAC 368 GAS ANALYSERTECHNICAL INFORMATIONThe FerMac 368 Gas Analyser is designed to analyse the O2 and CO2 content of the exit(headspace) gas from a bioreactor.This data refers to the Gas Analyser only and excludes any sampling system.The infra-red CO2 sensor was developed specifically for laboratory use to provide accurateand reliable determination of CO2 gas concentrations. The wave length is selected to avoidcross-sensitivity with other gases.0-10% CO2CO2 SensorRangeResolution 0.01% CO2Repeatability @ 0% CO2 = ±0.05% CO2@ 10% CO2 = ±0.15% CO2Response time With a flow rate of 100mls/min = 50 secondsTemperature drift 0.1% of full scale /CTypical Warm up time 10 minutesOperating temperaturerange 0-45ºCCO2 cell expectedoperating life 5-10 yearsCross sensitivity None1.Range 0-50% O20.1% O2Repeatability @ 21% O2 0.2% O2Response time With a flow rate of 100mls/min = 20 secondsTypical Warm up time 10 minutesOperating temperaturerange 0-45ºCO2 cell expectedoperating life 2 years in 21% O2Cross sensitivity:-The O2 cell has been tested for cross-sensitivity to a number of gases. The gasconcentrations used and the response of the O2 cell are summarised below:-GasO2 Cell Output(%O2equivalent)GasO2 Cell Output(%O2equivalent)16%CO2/Balance N2 <0.01 6%CO/Balance N2 <0.0025%H2 /Balance N2 <0.001 3000ppm NO/Balance N2 <0.0022000ppmn-hexane/Balance N2<0.01These figures show that, of the gases tested, none show a sufficiently large cross-sensitivity to cause any inaccuracy in readings. In addition the baseline wasunaffected by exposure to these gases.O2 0-5V = 0-50% max output 10VCO2 0-5V = 0-5% max output 10V (10%)4-20 mAO2 SensorAnalogue OutputOptionResolution2.For zero N2 100%For Calibration Typically 20% O2, 8% CO2, remainder N2The exact calibration values are normally supplied with the gasPush connector for 6mm OD tubingVoltage 115 or 230 VAC +/- 10% (switchable)Instrument Size 190mm wide x 190mm high x 330mm deepPacked Size 300mm wide x 310mm high x 410mm deepInstrument Weight 6 kgsPacked Weight 7 kgsQty. Item1 Power supply cablelyurethane tubing 6mm OD, 4mm IDoprene 3.2mm ID/1.6mm wall tubing3 Gas inlet connector2 Adapter, Luer, male, 3mm1 Filter, 50mm PTFE hydrophobic2 Fuse, 1 amp1 Adjustment screwdriver1 Output cable1 T-piece, 12mm through with 6mm T (Supplied as a sample)1 T-piece, 8mm through with 4mm T (Supplied as a sample)ing tube (Supplied as a sample - Ideal size & type willend on application)Calibration Gases RequiredGeneral InformationSample Inlet ConnectionAccessories Supplied1 Drydep6 metres Po0.3 metres Ne1 Instruction manual3.The FerMac 368 Gas Analyser comes with a 12 month guarantee covering all parts andlabour.A Service Contract giving a lifetime guarantee is available.All spare parts available for a minimumm of 10 years.Data Logging Using an Electrolab BioreactorThe analogue output from the gas analyser plugs into the input/output socket of theFerMac 360 controller and the data is logged along with other data from the fermenter.Adaption cable interface cards are extra.Data Logging Using Other BioreactorsThe analogue output from the gas analyser plugs into any spare analogue input channel.Data Logging Using Stand-alone SoftwareThe Electrolab eLogger is a data logging and graphing system comprising a hardwareinterface and software package which provides an intuitive means of logging analoguesignals to your computer. The data is displayed on screen by means of a virtual instrumentand a live chart display. Contact us (info@electrolabtech.co.uk) for further details.DiscDue nuing development, this technical information may be subject to change at any time withoutnotiService/SparesData Logginglaimer to our policy of contification.4.leaflets & brochures/specs/368 Tech Info-Rev.3 Oct 11 FERMAC 368 GAS ANALYSER TECHNICAL INFORMATION Typical Warm up time 10 minutes Cross sensitivity:- Gas Gas Option4-20 mA Instrument Weight6 kgs Packed Weight7 kgs Data Logging Using an Electrolab Bioreactor Data Logging Using Other Bioreactors Data Logging Using Stand-alone Software Disclaimer
Most popular related searches