Mar Cor - Evoqua Water Technologies LLC
- Home
- Companies & Suppliers
- Mar Cor - Evoqua Water Technologies LLC
- Downloads
- FiberFlo - Hollow Fiber Cartridge ...
FiberFlo - Hollow Fiber Cartridge Filters Brochure
FiberFlo® EN Endotoxin Removal FiltersEndotoxin Control with 100% Flow Recovery Endotoxin/Pyrogen RemovalThe unique membrane structure of FiberFlo EN cartridge and capsule filters provides consistent and verifiable pyrogen removal. The high level of endotoxin removal makes these filters ideal for a variety of applicationsrequiring the removal of endotoxins for assured fluid purity.Total Flow RecoveryFiberFlo EN filters are “normal flow” filters. They remove endotoxins because of the affinity of the membrane with the endotoxin molecules. The endotoxin binds to the membrane, but the membrane allows all of the product flow through the filter. There is no waste stream like that created by a tangential flow filter.Easy to Install and MaintainUnlike most tangential flow devices, FiberFlo EN Hollow Fiber cartridge filters can be steam sterilized in-line or autoclaved off-line. FiberFlo cartridge filters are available in four lengths and a variety of end cap styles to fit a variety of standard filter housings in process applications.FiberFlo EN capsule filters come in a variety of sizes and have a variety of end connections (Sanitary, Hose Barb and NPT) for easy installation in your equipment.Quality AssuredAll FiberFlo cartridge and capsule filters are manufactured to meet medical device quality standards with adherence to QSR manufacturing guidelines. These filters exceed the requirements of USP Class VI Plastics Testing and meet USP XXIII standardsfor purified water extractables. FiberFlo EN cartridge filters are integrity testable by diffusional methods.Consistent and Verifiable Pyrogen Removal• Removes endotoxin/pyrogen• Normal flow filtration—No waste stream from tangential flow• Higher flow rates at lower pressure drops• Autoclavable and steam sterilizable• Extended life—cleanable, sanitizable• In-situ integrity testable• Hydrophilic membranes—repeatedly rewettable without wetting agents• Biocompatible for medical applicationFiberFlo EN Capsule FiltersFiberFlo EN Cartridge FiltersMar Cor Purification14550 28th Avenue NorthPlymouth, MN 55447Tel: (484) 991-0220 Toll Free: (800) 633-3080Fax: (763) 210-3868Mar Cor Purification3250 Harvester Road - Unit 6Burlington, ON L7N 3W9Tel: (905) 639-7025Toll Free: (800) 268-5035Fax: (905) 639-0425Mar Cor PurificationSourethweg 116422 PC HeerlenThe NetherlandsTel: (+31) 45 5471 471Fax: (+31) 45 5429 695Mar Cor Purification 1A International Business Park, #05-01Singapore 609933Tel: (+65) 6227 9698Fax: (+65) 6225 6848©2011 Mar Cor Purification. All rights reserved. P/N:50096-179 Rev.BVisit www.mcpur.com for more information or call 1-800-633-3080Mar Cor Purification4450 Township Line RoadSkippack, PA 19474-1429Tel: (484) 991-0220 Toll Free: (800) 346-0365Fax: (484) 991-0230Flow - lpm (GPM)Pressure Drop - Bar (psid)2.07 (30)1.72 (25)1.38 (20)1.03 (15).69 (10).34 (5)0Large CapsuleMedium CapsuleTypical Water Flow Rates - FiberFlo(10-inch Nominal Length)7.63.7 15.111.4 30.322.7(2)(1) (4)(3) (8)(6)Flow - lpm (GPM)Pressure Drop - Bar (psid)Typical Water Flow Rates - FiberFlo(10-inch Nominal Length)(6)(5)(4)(3)(2)(1)0.41.34.28.21.14.071.9 (0.5)3.8 (1)5.7 (1.5)7.6 (2)9.5 (2.5)11.4 (3)13.2 (3.5)15.1 (4)FiberFlo Cartridge Filter SpecificationsMembrane Polyphen® PolysulfoneMaximum DifferentialPressure 2 Bar (30 PSI)Membrane Surface Area(Per 10” Segment) 1.5 m2 (16 ft2Filter Diameter 6.4 cm (2.9”)Nominal Length 25 cm, 51 cm, 76 cm, 102 cm (10”, 20”, 30”, 40”)Case and End Caps PolycarbonateSeal Materials PolyurethaneExtractables Passes U.S.P. tests for oxidizable substances and total solids for purified water.Fiber meets all Class VI criteria as well as test standards for tissue cytoxicity.Technical DataFiberFlo Capsule Filter SpecificationsMembrane Polyphen® PolysulfoneMaximum DifferentialPressure 2 Bar (30 PSI)Surface Area M = 1.83 m2 (2.0 ft2), L = 0.61 m2 (6.0 ft2 )Case and End Caps PolycarbonateExtractables Passes U.S.P. tests for oxidizable substances and total solids for purified water.Fiber meets all USP-XXIII Class VI criteria as well as test standards for tissue cytoxicity.Pressure Drop and Flow RatesFiberFlo Capsule Ordering InformationCode Inlet Description Outlet DescriptionA 1/4 inch NPT 1/4 inch NPTB 3/8 inch NPT 3/8 inch NPTC 1/2 inch hose barb 1/2 inch hose barbD 3/8 inch hose barb 3/8 inch hose barbE 1/4 inch NPT 1/2 inch hose barbF 1/4 inch NPT 3/8 inch hose barbG 3/8 inch NPT 1/2 inch hose barbH Sanitary SanitaryJ Mini-ISO Mini-ISONomenclature Format - x-l-EN-yM - I - EN - KCapsule SizeL = 6.0 ft2 (1.83 m2)M = 2.0 ft2 (0.61 m2)End-Fitting Option(see chart)FiberFlo Cartridge Ordering Information1. Select type EN EN EN EN2. Select length 10 in (25 cm) 20 in (25 cm) 30 in (76 cm) 40 in (102 cm)3. Select styleStyle 3: SOE flat, closed end, external 222 O-ring. Replaces Pall Code 3, Millipore Code 0Style 4: SOE fin end, external 222 O-ring. Replaces Pall Code 8, Millipore Code 5Style 5: SOE fin end, external 226 O-ring. Replaces Pall Code 7, Millipore CodeStyle 7: SOE mini fin end, internal 119 O-ring. Installs in standard 10 inch Ametek HousingStyle 8: SOE flat, internal 119 O-ring. Installs in standard 20 inch Ametek HousingExample: EN-103 would be a 10 inch, SOE flat, closed end, external 222 O-ring.*Simple filter bowl modifications are required for this cartridge.
Most popular related searches
