Xerxes Corporation
- Home
- Companies & Suppliers
- Xerxes Corporation
- Downloads
- Fiberglass Underground Petroleum ...
Fiberglass Underground Petroleum Storage Tanks - Brochure
a subsidiary of ZCL Composites Inc. Fiberglass Underground Petroleum Storage TanksA proven tank choice for the petroleum industryAfter years of installing bare steel underground storage tanks forgasoline and diesel fuel, in the 1960s companies began to realizethat leakage from steel tanks – because of rust both inside andoutside – caused environmental problems. Since the mid 1960s,fiberglass underground storage tanks (USTs) have provided tankowners with a reliable corrosion-free option that led to federal reg-ulations in the late 1980s mandating corrosion-protected tanks.There are even more reasons to choose a Xerxes fiberglass tanktoday. It is compatible with new ethanol-blended fuels andbiodiesels, requires no maintenance to prevent corrosion, and,unlike steel tanks, accommodates continuous hydrostatic moni-toring. And in contrast to some other UST products, standing be-hind every Xerxes petroleum tank is an industry-leading 30-yearlimited warranty.Today, more than 40 years after their introduction, a large per-centage of USTs sold in North America are made of fiberglass. Infact, the tanks installed by the 50 largest fuel marketers in theUnited States are overwhelmingly fiberglass tanks. In Canada, itis estimated that more than 90 percent of tanks installed for pe-troleum storage are made of fiberglass. As of 2008, more than150,000 Xerxes fiberglass tanks had been installed, and the num-ber continues to grow.In addition to their functional benefits, fiberglass tanks are sig-nificantly lighter and easier to install than steel tanks becausethey eliminate the expense of renting heavy equipment during in-stallation. Yet another benefit is that fiberglass tanks can oftenbe moved from an original installation site and be recertified forinstallation at a new location.At Xerxes, we believe in going the extra mile for our customers.Headquartered in Minneapolis, Minnesota, with four manufac-turing facilities strategically located for economical delivery andquality service, Xerxes is committed to customer satisfactionand quality products. Together with our parent company, ZCLComposites Inc., we are North America’s choice in undergroundstorage – for today and for tomorrow.Xerxes is dedicated to delivering high-quality productsthat help preserve the environment, whether in the mid-dle of a city, a suburban neighborhood or a rural setting.Xerxes® Fiberglass Tanks –1Xerxes – a long-time industry leader and pioneerThe Xerxes Mission StatementTo be the leading global provider of environmentally friendly liquid storage solutions,while providing superior returns to our shareholders.For decades, Xerxes has proven itself an industry leader in de-veloping and fabricating fiberglass reinforced plastic (FRP) struc-tural products. Xerxes’ commitment to quality and innovation isthe foundation of the strong, long-lasting relationships we havewith our customers. Xerxes engineers were the first to utilize in-tegrally constructed ribs in fiberglass tanks for added strength.Xerxes was also the first to manufacture a UL-listed, double-wallfiberglass underground storage tank (UST) and the first to incor-porate the unique benefits of hydrostatic monitoring into a fac-tory-manufactured design.As customers’ needs change and as regulations become morecomplex, Xerxes continues its history of innovation by develop-ing products that meet the changing needs of customers in thepetroleum, water and wastewater industries. Today, the Xerxes®tank product line includes double-wall, triple-wall and multicom-partment tanks, as well as oil/water separators, wet-wells andprepackaged lift stations. Complementing these product lines isa wide variety of Xerxes-supplied accessories that not only providefor speed and ease of installation (such as prefabricated concretedeadmen) but also respond to changing regulations. Our innova-tive double-wall containment sump is an example of this. Xerxesis committed to developing new and complementary accessoriesto our growing line of products, with a careful eye on new in-dustry demands and trends.Today, as part of ZCL Composites Inc., Canada’s leading providerof fiberglass USTs, product innovations such as ZCL’s PhoenixSystem® and PrezerverTM, and use of Parabeam®, further enhanceour premiere product line. (See pages 5 and 7 of this brochure formore information.) Together, Xerxes and ZCL are widely recog-nized as North America’s leading provider of underground fiber-glass storage tanks.2The benefits of Xerxes® fiberglass underground storage tanks3The best choice for underground storage of petroleum productsis a structurally strong, corrosion-resistant, easily installed andcost-effective vessel. That’s what a customer finds in every Xerxestank, which is designed and manufactured with high-quality resinand glass, and features unique integral ribs. Like structural beams,integral ribs add strength, and because the ribs and tanks aremade of the same materials and are manufactured simultane-ously, the result is an extremely robust product.The solution to new corrosion concernsMade of corrosion-resistant materials, Xerxes fiberglass tankseliminate the possibility of either external or internal rusting ofthe tank. For years, the concern in the petroleum industry wasabout external corrosion. Since fiberglass doesn’t rust, and steelcan, this gave fiberglass tank manufacturers a natural edge.Today, corrosion concerns in petroleum tanks center on internalcorrosion, an even more pressing matter because of new fuels,such as ethanol blends and biodiesels. Together, the removal oflead from gasoline and the growing popularity of biofuels haveled to heightened awareness about corrosive environments insidestorage tanks.A certain amount of water usually exists in the bottom of tanks,and that can lead to the microbial-induced corrosion (MIC) in steeltanks. Ethanol increases the likelihood of water in tanks, and theresulting microbial growth. To date, there is not a single reportedinstance in a fiberglass tank of failure due to internal corrosioncaused either by MIC or by water bottoms. Based on widely dis-tributed advice, combatting internal corrosion in steel tanks re-quires regular maintenance – in the form of frequent inspectionfor and removal of water from tank bottoms. In contrast, fiber-glass tanks require no maintenance against corrosion.Many believe that this new concern about internal corrosion isthe reason the Steel Tank Institue (STI) and some steel-tank man-ufacturers have significantly reduced their warranty coverage,from 30 to 10 years. Since Xerxes fiberglass tanks are compatiblewith the new biofuels, including E10, E85 and biodiesel blends,Xerxes confidently holds to its longstanding 30-year warranty,which explicitly provides 30 years of internal corrosion coverage“with or without water bottoms.”Why choose a Xerxes® tank?? Fuel compatibility – Xerxes tanks are UL-listed for all ethanol-blended fuels, including E10 and E85, andare fully compatible with new diesel blends, including ultra-low sulfur diesel (ULSD) and biodiesel blends.? Maintenance-free – Xerxes does not require the frequent inspection for and removal of tank waterbottoms, which is a time-consuming and expensive maintenance step that is strongly recommended bythe steel tank industry for its products. While some manufacturers' warranties limit coverage whenwater bottoms are present, Xerxes' warranty specifically states "with or without water bottoms."? 30-Year warranty – While the warranty duration for many other storage tanks has been dramaticallyreduced in recent years, Xerxes continues to provide a 30-year limited warranty, backed by the financialstrength of North America's leading storage tank manufacturer.? Continuous monitoring – Interest is growing in the use of a "continuous monitoring" system in theinterstice of a new double-wall tank. In fact, states such as California have regulations requiring it.Xerxes' TRUCHEK® hydrostatic monitoring system, with an outstanding 20-year track record, is the perfectsolution. The alternative vacuum systems in the market (which can be expensive to maintain) have but asmall fraction of the in-service history that TRUCHEK offers.? Tank of choice – Fiberglass tanks represent the overwhelming choice of the 50 largest petroleummarketers in the United States, based on their annual tank purchases. As the leading supplier ofunderground storage tanks, Xerxes is the tank of choice for all petroleum applications, whether retail,commercial, or industrial.4Xerxes® tanks now offer the benefits of Parabeam®ZCL’s PrezerverTM Systemenhances Xerxes’ product lineXerxes double-wall tanks now featureParabeam® 3D glass fabric, a lightweightyet strong “sandwich” laminate that of-fers excellent mechanical properties.Parabeam® is a unique glass fabric con-sisting of two decklayers woven togetherby vertical glass piles that form an inte-gral sandwich structure. When theParabeam® is impregnated with a ther-moset resin, the fabric rises to the presetheight, producing a unique laminate witha defined interstitial space that can bemonitored hydrostatically or with a dry leak-detection system.Parabeam® is a wholly-owned subsidiary of ZCL, allowing bothXerxes and ZCL to incorporate a proprietary material that hasbeen successfully used in Canada for more than 12 years.A new option for Xerxes customers is the ZCL PrezerverTM Sys-tem. This “system” solution for owners of petroleum fueling fa-cilities provides a level of equipment reliability and third-partyliability protection that is unique in the industry. At the center ofthe PrezerverTM System are the industry’s leading choices forproduct storage: PrezerverTM double-wall tanks or the ZCLPhoenix System®, together with a unique and comprehensivepackage of insurance protection, which is only available to Prez-erverTM System customers. Additionally, each PrezerverTM Systeminstallation has site inspections of critical steps that are docu-mented by a qualified third-party firm and compiled into a pro-fessional final inspection report (including photos), which is thenprovided to the owner.While this program goes beyond federal financial responsibility(FR) requirements for tank owners, it is designed to comply withvarious states’ minimum FR requirements. (Check with the spe-cific requirements of your state.) Owners in states that provide astate fund intended to address FR requirements in lieu of privateinsurance will find the broad coverage of the PrezerverTM MasterProgram of Insurance to be very attractive, offering a level of cov-erage that exceeds that of state funds. (See Xerxes’ ZCL Prez-erverTM System brochure for more information.)Each PrezerverTM System includes the following components:? PrezerverTM double-wall tank and required accessories? TRUCHEK® hydrostatic monitoring system? FRP containment collar and sump with a watertight lid? prefabricated, engineered, concrete deadmen? FRP hold-down straps and galvanized turnbuckles? approved double-wall piping system? approved fiberglass dispenser sumps? approved electronic monitoring system for the tanks,piping and all sumps.5Benefits of ZCL’s? may eliminate the need to purchase/renew annual insurance policies (with unpredictable premium costs) for 10 years? provides confidence that the fueling system is correctly installed? provides permanent record of key installation steps, with an inspection report that includes photos? may avoid the need to purchase state-mandated private insurance – providing significant savings? coverage for existing tanks may be available at below-market rates (subject to underwriting requirements)6Continuous leak detectionFor nearly twodecades, theXerxes® TRUCHEKsystem has suc-cessfully moni-tored thousandsof tanks in manydifferent types ofinstallations. Infact, it has be-come an industrystandard as astate-of-the-art technique for continuous monitoring. Changingregulations in some markets, such as California, require that newdouble-wall tanks have continuous leak detection using a constantvacuum, air pressure or hydrostatic pressure in the interstice of adouble-wall tank. A Xerxes tank with TRUCHEK’s continuous leakdetection is the ideal solution for complying with these strict newrequirements.While being highly effective, TRUCHEK is also simple and trou-ble-free in both design and operation. With TRUCHEK, simplemonitoring of the fluid level inside the reservoir of a Xerxes dou-ble-wall tank is all that is necessary. When you order a Xerxesdouble-wall tank with the TRUCHEK option, the interstice be-tween the two tank walls is filled at the factory with a monitor-ing fluid. This water/calcium-chloride fluid also partially fills areservoir on the top of the tank. This creates a hydrostatic pres-sure throughout the interstice, enabling the operator to monitorthe walls of both the primary tank and the secondary tank. Anelectronic probe placed in the tank’s reservoir alarms when thefluid level either falls below or rises above the acceptable level.(See the Xerxes TRUCHEK brochure for more information.)Tank-tightness testingTRUCHEK also provides a simple, precise and reliable method toperform a tank-tightness test. It takes into account the impactsof thermal expansion or contraction of the product, vapor pock-ets, tank deflection, evaporation, condensation and the locationof the water table. The 10-hour tightness-test procedure meetsthe strict NFPA 329 criteria. A shorter 4-hour test (while productis dispensing) exceeds EPA’s criteria for a tank-tightness test.TRUCHEK® – state-of-the-art continuous monitoringHow does TRUCHEK® work?ReservoirLevel DownVentReservoirLevel DownVentReservoirLevel UpLeak inOuter WallVentPrimary-Tank Leak in Wet Hole or Dry HoleSecondary-Tank Leak in Dry HoleSecondary-Tank Leak in Wet HoleTo enhance the double-wall protection of a Xerxes® tank, Xerxes offers the option of TRUCHEK, its state-of-the-art system of hydrostatic,tank monitoring for double-wall tanks. TRUCHEK is an easy, precise and reliable method for both continuous leak detection and tank-tightness testing. Like the tanks that Xerxes manufactures, TRUCHEK provides a long, successful record of performance.7Additional underground storage tank solutionsMulticompartment tanks – a popular option for retail marketersTriple-wall tanks – the choice when double-wall protection isn’t enoughWhether a customer needs two or three tanks in one, tertiary containment, or an upgrade of an existing single-wall tank, Xerxes hasproducts that meet a customer’s requirements. Together with a full line of tank accessories, Xerxes offers customers the most com-prehensive range of storage tank solutions found in the petroleum equipment industry.Some customers and regulatory agencies now require evenmore enhanced protection than double-wall tanks provide. Acondition such as a sensitive groundwater aquifer, or a nearbylake or stream is a reason to consider tertiary containment forunderground storage. The Xerxes UL-listed triple-wall tank(TWT®), with an additional Parabeam® interstice, is the innova-tive and cost-effective answer when this level of containment isrequired. As with all Xerxes double-wall tanks, the triple-wallmodel is available with TRUCHEK monitoring or with the use ofa dry interstitial monitoring system. And, like all Xerxes tanks,the triple-wall tank is easy to ship and install, and available fromeach of our four U.S. facilities.In some situations, single-wall tanks that need to be up-graded to a double-wall tank offer site challenges that makeexcavation of existing tanks either cost-prohibitive or ex-tremely difficult. For instance, tanks installed years ago aresometimes covered or surrounded by buildings, roads or raillines. In such cases, converting a single-wall tank (either fiber-glass or steel) into a double-wall tank can most efficiently bedone with ZCL’s Phoenix System®. The UL-listed system con-sists of two corrosion-resistant laminates and the proprietaryParabeam® glass fabric that together create an interstitialspace. The interstice created can be either dry or hydrostati-cally monitored. The corrosion-resistant UL-listed system, ap-plied on site by trained installers, is all-fuels compatible,including alcohol-blended fuels, E85 and biodiesels. This isyet another example of the innovative solutions available toXerxes customers. (See the ZCL Phoenix System® brochurefor more information.)Whether a customer needs two tanks in one, or three tanks inone, the Xerxes® multicompartment fiberglass undergroundstorage tank offers a superior option for the storage of morethan one product at a site. These Xerxes tanks are a popularchoice among retail gasoline marketers and convenience-storeowners. The ability to store two or three grades of fuel, or gaso-line and diesel, in a minimal amount of space is particularly ap-pealing when available property is limited and the amount ofonsite space needed for multiple tanks is difficult to obtain. Cus-tomers may also find installation and insurance cost savingswhen using multicompartment tanks. Some regulatory agenciesrequire a double-wall bulkhead between certain products, forinstance, between diesel and unleaded fuel. The Xerxes double-wall multicompartment tank comes standard with a double-wall bulkhead, while other tank manufacturers’ standardoffering requires an upgrade to a double-wall bulkhead. WhenTRUCHEK® hydrostatic monitoring is used, all two or three com-partments are monitored with a single reservoir and sensor.The ZCL Phoenix System® – the best choice for existing tank upgrades8Guide Specifications – Xerxes® Fiberglass Underground Storage TanksShort form:The contractor shall provide a single-wall, double-wall or triple-wallfiberglass reinforced plastic (FRP) Underwriters Laboratories-labeled un-derground storage tank as shown on the drawings. The tank size, fit-tings and accessories shall be as shown on the drawings. The fiberglasstank shall be manufactured by Xerxes® Corporation.The tank shall be tested and installed according to the Xerxes Installa-tion Manual and Operating Guidelines for Fiberglass UndergroundStorage Tanks in effect at time of installation.Long form:Part I: General1.01 Quality AssuranceA. Acceptable Manufacturer: Xerxes CorporationB. Governing Standards, as applicable:1. Underwriters Laboratories (UL) Standard for Safety 1316 forstorage of flammable liquids. A UL label shall be attached toeach tank.2. National Fire Protection Association (NFPA) Standards:NFPA 30: Flammable and Combustible Liquids CodeNFPA 30A: Automotive and Marine Service Station CodeNFPA 31: Installation of Oil-Burning Equipment.3. City of New York Department of Buildings M.E.A., Division#161-89-M.Part II: Products2.01 Single-wall, Double-Wall and Triple-Wall Fiberglass ReinforcedPlastic (FRP) Underground Storage Tanks:A. Loading Conditions – Tank shall meet these design criteria:1. Internal Load – Single-wall, double-wall and triple-wall tankshall withstand a 5-psig air-pressure test with 5:1 safety factor.Contractor shall individually test tanks for leakage prior to in-stallation. Maximum test pressure is 5 psig (3 psig for a 12'-di-ameter tank).2. Vacuum Test – To verify structural integrity, every standard 10'-diameter tank and smaller shall be vacuum-tested by the manu-facturer at the factory to 11.5" of mercury. All 12'-diametertanks shall be tested by the manufacturer to 5.5" of mercury.3. Surface Loads – Tank shall withstand surface H-20 axle loadswhen properly installed according to Xerxes' current InstallationManual and Operating Guidelines.4. External Hydrostatic Pressure – Tank shall be capable of beingburied in ground with 7' of overburden over the top of thetank, the hole fully flooded and a safety factor of 5:1 againstgeneral buckling.5. Tank shall support accessory equipment – such as heating coils,drop tubes, submersible pumps and ladders – when properly in-stalled.B. Product Storage:1. Tank shall be capable of storing petroleum products with spe-cific gravity up to 1.1.2. Tank shall be vented to atmospheric pressure.3. Tank shall be capable of storing products identified in the man-ufacturer’s current standard limited warranty.C. Materials:1. Tank shall be manufactured with 100% resin and glass-fiber re-inforcement. No sand fillers.D. Tank Dimensions (Refer to Xerxes literature on gallonage.):1. Tank shall have nominal capacity of _____ gallons.2. Tank shall have nominal outside diameter of _____ feet.E. Interstitial Space1. Double-wall and triple-wall tank shall have a space between thewalls to allow for the free flow and containment of leakedproduct from the primary tank. The space also allows the inser-tion of a monitoring device through a monitoring fitting.2.02 AccessoriesA. Optional Anchor Straps1. Straps shall be FRP anchor straps as supplied by tank manufac-turer.2. Number and location of straps shall be specified in current liter-ature by tank manufacturer.B. Manways1. All manways shall be flanged and 22" I.D., complete with UL-listed gaskets, bolts and covers. (30" and 36"I.D. manways arealso available on certain larger tanks.)2. Location is shown on tank drawings.3. Optional manway extensions shall be FRP and _____ incheslong.4. All 12'-diameter tanks require at least one manway.C. Optional Fill Tubes1. Fill tubes shall be FRP, 4" in diameter, with a 6" x 4" double-tapped reducer bushing, and include a 6" NPT fitting. Tubesshall terminate a minimum of 4" from the bottom of tank (aminimum of 6" for a 12'-diameter tank).D. Striker Plates1. Striker plates shall be installed under each service fitting andmanway opening.E. Optional Heating Coils1. Optional heating coils shall be installed in a separate 22"-diam-eter manway and shall be as supplied by tank manufacturer.F. Optional Ladders1. Ladders shall be the standard ladder as supplied by tank manu-facturer (aluminum, carbon steel or fiberglass).G. NPT Threaded Fittings1. All NPT threaded fittings shall be a material of construction con-sistent with the requirements of the UL label.2. All standard threaded fittings shall be half-couplings and shallbe 4" or 6" in diameter. Reducers are to be used for smallersizes where shown and provided by contractor.3. Strength – NPT fittings shall withstand a minimum of 150 foot-pounds of torque and 1,000 foot-pounds of bending, both witha 2:1 safety factor.H. Monitor Fittings1. The monitor fitting for a double-wall and triple-wall tank shallconsist of a 4" NPT fitting on the tank.2.03 Optional Monitoring SystemA. General1. The tank manufacturer shall offer the option of a continuouslymonitored, hydrostatic leak-detection system for its double- andtriple-wall tanks.2. The monitoring system shall be designed by the manufacturerto detect a leak in either the primary, secondary or tertiary tank,at installations with or without groundwater.3. The monitoring system shall include monitoring fluid in the pri-mary interstice delivered to the installation site. The contractorshall be responsible for field installation of monitoring fluid inthe secondary interstice.4. The reservoir(s) shall be fitted with one 4" NPT fitting for instal-lation of an electronic, reservoir-level sensor.Part III: Testing and Installation3.01 TestingA. Testing – Tank shall be tested according to the applicable XerxesInstallation Manual and Operating Guidelines in effect at time ofinstallation.3.02 InstallationA. Installation – Tank shall be installed according to the applicableXerxes Installation Manual and Operating Guidelines in effect attime of installation.Part IV: Limited Warranty4.01 Limited WarrantyA. Limited Warranty – Warranty shall be manufacturer's standard lim-ited warranty in effect at time of purchase.9Xerxes® Underground Tank DataNominalCapacity(gal)ActualTank Length(ft/in) *Number ofHold-downStraps Req’d600 6'-11 7/8" SW7'-3 1/2" DW21,000 11'-3 7/8" SW11'-7 1/2" DW22,000 13'-5 3/4" SW 22,500 13'-5 3/4" DW 23,000 16'-4 1/4" 24,000 21'-11 1/8"SW20'-8" DW25,000 26'-5" 46,000 30' - 8 3/4" 42,000 9'-1/2" SW 23,000 12'-3" SW 24,000 15'-1/2" 25,000 17'-8 1/2" 26,000 20'-6 1/2" 48,000 26'-1/2" 410,000 31'-6 1/2" 412,000 37'-1/2" 415,000 46'-9" 6602 800 1,0001,009 1,100 1,400––– ––– –––2,324 1,800 2,4002,910 2,100 2,8003,789 2,500 3,5004,961 3,100 4,3005,840 3,600 4,900––– ––– –––––– ––– –––4,190 2,200 3,1005,089 2,600 3,7006,044 2,900 4,3007,899 3,600 5,4009,753 4,300 6,60011,608 5,000 7,70014,881 6,400 9,800602 5001,009 7002,376 1,000––– –––2,973 1,2004,131 1,6005,064 1,9005,960 2,2002,189 9003,271 1,2004,218 1,4005,165 1,7006,084 2,0007,950 2,5009,816 3,00011,682 3,50014,975 4,500ActualCapacity(gal) **Dry NominalShippingWeight (lbs)Wet NominalShippingWeight (lbs)ActualCapacity(gal) **NominalShippingWeight (lbs)4-foot-diametertanks6-foot-diametertanks8-foot-diametertanks10,000 21' - 5 1/4" 412,000 24' - 1/4" 415,000 29' - 5 3/4" 420,000 37' - 8 3/4" 625,000 47' - 6 3/4" 830,000 55' - 9 3/4" 1035,000 64' - 3/4" 1240,000 73' - 8 1/4" 1410,420 4,500 6,20011,904 5,000 7,00015,041 6,100 8,60019,782 7,700 11,00025,431 10,000 14,30030,172 11,900 17,00034,912 13,600 19,60040,443 16,000 23,00010,563 3,20012,068 3,60015,248 4,50020,055 5,70025,783 7,90030,590 9,40035,397 10,50041,004 12,10010-foot-diametertanks20,000 29'-4" SW 625,000 35'-7" SW 830,000 43'-1" SW 1035,000 49'-4" SW 1240,000 54'-4" SW 1248,000 65'-7" SW 1850,000 68'-1" SW 18––– ––– –––––– ––– –––––– ––– –––––– ––– –––––– ––– –––––– ––– –––––– ––– –––20,781 9,20025,541 10,60031,253 12,50036,013 13,90039,821 15,00048,389 17,70050,293 18,30012-foot-diametertanksSingle-wall & Double-wall Tanks Double-wall Tanks Single-wall TanksNotes:* Unless otherwise noted, the tank length applies to both single-wall (SW) and double-wall (DW) tanks.** Use of overfill protection such as flapper valves or ball-float valves will reduce the actual capacity of the tank.10Limited WarrantyDouble-Wall and Single-Wall Storage Tanks for Petroleum or Alcohol FuelsXerxes Corporation ("Xerxes") warrants to owner ("Owner") that our double-wall and single-wall underground storage tanks, if installed, used,and maintained in the United States or Canada in accordance with Xerxes' published specifications, installation instructions and operating guide-lines, and all applicable laws and regulations:1) Will not fail for a period of thirty (30) years from date of original delivery by Xerxes due to natural external corrosion.2) Will not fail for a period of thirty (30) years from date of original delivery by Xerxes due to internal corrosion, provided the tank is used solely, (withor without tank water bottoms), to store the following products at ambient temperature, or fuel oils at temperatures not to exceed 150° F (65° C):a. gasoline, jet fuel, aviation gasolines, motor oils, motor vehicle waste oils, kerosene, diesel fuels, or fuel oilsb. alcohol, alcohol-gasoline blends, and oxygenated motor fuels1. ethanol and ethanol blends• 100% ethanol• E10 (90% gasoline and 10% ethanol)• E85 (85% ethanol and 15% gasoline)2. methanol and methanol blends• 100% methanol• M85 (85% methanol and 15% gasoline)• Oxinol-501 waiver (90.5% gasoline and 9.5% Oxinol-501 comprised of a 4.75% methanol and 4.75% GTBA mixture)• Dupont EPA waiver (gasoline with 5% methanol and a minimum of 2.5% cosolvent – the blend may contain a maximumconcentration of up to 3.7%, by weight, oxygen in the final fuel)3. other oxygenated fuels• gasoline with up to 20%, by volume, of methyl tertiary butyl ether (MTBE), ethyl tertiary butyl ether (ETBE), di-isopropyl ether(DIPE), tertiary amyl methyl ether (TAME), or tertiary amyl ethyl ether (TAEE)c. biodiesel fuel as defined by:1. ASTM®2 D975-08a (diesel fuel oils)2. ASTM®2 D396-08b (fuel oils)3. ASTM®2 D7467-08 (diesel fuel oil and biodiesel blend (B6-20))3) Will not fail for a period of thirty (30) years from date of original delivery by Xerxes due to structural failure (defined as spontaneous breaking orcollapse caused by material defects in materials or workmanship).4) Will meet Xerxes' published specifications and will be free of material defects in materials and workmanship for a period of one (1) yearfollowing the date of original delivery by Xerxes.If any tank is to be removed from an installation, moved to Owner’s new location and is intended for active service at the new location, the tankmust be recertified by Xerxes in order to maintain the limited warranty as originally extended.Xerxes warrants to Owner that all Xerxes manufactured tank accessories, if installed, used and maintained in the United States or Canada in accor-dance with Xerxes' published specifications, installation instructions and operating guidelines, and all applicable laws and regulations, will be free frommaterial defects in materials and workmanship for a period of one (1) year following the date of original delivery by Xerxes.The foregoing limited warranty does not extend to tanks or accessories (collectively “Goods”) damaged due to acts of God, war, terrorism, or failureof Goods caused, in whole or in part, by misuse, unlawful use, improper installation, storage, servicing, maintenance, or operation in excess of theirrated capacity or contrary to their recommended use, whether intentional or otherwise, or any other cause or damage of any kind not the fault ofXerxes. Xerxes only warrants repairs or alterations performed by Xerxes or its authorized contractors. Xerxes does not warrant any product, compo-nents or parts manufactured by others.Owner's sole and exclusive remedy for breach of warranty is limited at Xerxes' option to: (a) repair of the defective tank or accessory, (b) delivery ofa replacement tank or accessory, to the point of original delivery, or (c) refund of the original purchase price. In the event of a breach of warrantyclaim, a claimant must give Xerxes the opportunity to observe and inspect the installation prior to the removal of any backfill below the tank top, andthe removal of the tank and any accessory from the ground, or the claim will be forever barred. All claims must be made in writing within one (1) yearafter tank and/or accessory failure or be forever barred.THE FOREGOING LIMITED WARRANTY CONSTITUTES XERXES' EXCLUSIVE OBLIGATION AND XERXES MAKES NO OTHER WARRANTY OR REPRE-SENTATION, EXPRESS OR IMPLIED, WITH RESPECT TO THE TANK, ACCESSORY OR ANY SERVICE, ADVICE, OR CONSULTATION, IF ANY, FURNISHED TOOWNER BY XERXES OR ITS REPRESENTATIVES, WHETHER AS TO MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR OTHERWISE. THESELLER (XERXES) UNDERTAKES NO RESPONSIBILITY FOR THE QUALITY OF THE GOODS, EXCEPT AS OTHERWISE PROVIDED IN THIS CONTRACT. THESELLER (XERXES) ASSUMES NO RESPONSIBILITY THAT THE GOODS WILL BE FIT FOR ANY PARTICULAR PURPOSE FOR WHICH YOU (OWNER) MAY BEBUYING THESE GOODS, EXCEPT AS OTHERWISE PROVIDED IN THE CONTRACT. THE REMEDIES SET FORTH IN THE ABOVE LIMITED WARRANTY ARETHE ONLY REMEDIES AVAILABLE TO ANY PERSON OR ENTITY FOR BREACH OF WARRANTY OR FOR BREACH OF ANY OTHER COVENANT, DUTY, OROBLIGATION ON THE PART OF XERXES. XERXES SHALL HAVE NO LIABILITY OR OBLIGATION TO ANY PERSON OR ENTITY FOR BREACH OF ANY OTHERCOVENANT, DUTY OR OBLIGATION UNDER THIS LIMITED WARRANTY EXCEPT AS EXPRESSLY SET FORTH HEREIN. IT IS EXPRESSLY AGREED THAT THISLIMITED WARRANTY DOES NOT FAIL OF ITS ESSENTIAL PURPOSE. XERXES SHALL HAVE NO LIABILITY FOR COSTS OF INSTALLATION OR REMOVAL OFGOODS, ENVIRONMENTAL CONTAMINATION, FIRES, EXPLOSIONS, OR ANY OTHER CONSEQUENCES ALLEGEDLY ATTRIBUTABLE TO A BREACH OFWARRANTY, OR INCIDENTAL, CONSEQUENTIAL, PUNITIVE OR OTHER DAMAGES OF ANY DESCRIPTION, WHETHER ANY SUCH CLAIM OR DAMAGESBE BASED UPON WARRANTY, CONTRACT, NEGLIGENCE, STRICT LIABILITY OR OTHER TORT, OR OTHERWISE. IN NO EVENT SHALL XERXES' TOTAL LIA-BILITY HEREUNDER EXCEED THE ORIGINAL PURCHASE PRICE OF THE GOODS WHICH GAVE RISE TO SUCH LIABILITY.Consumer Notice: This limited warranty gives you (Owner) specific legal rights. You (Owner) may also have other rights which vary from state to state.1 TM Arco Chemical Co.2 ASTM® and ASTM INTERNATIONAL® are trademarks owned by the American Society for Testing and Materials, a non-profit corporation, and are usedhere for reference.Xerxes® Corporation Effective: : 2/15/097901 Xerxes Avenue South | Minneapolis | MN | 55431Ph: 952.887.1890 Fax: 952.887.1882 www.xerxes.comWaverley, NSDrummondville, QCDrummondville, QCEdmonton, ABa subsidiary of ZCL Composites Inc. xpb02/09pp© 2009 Xerxes Corporation Xerxes Manufacturing FacilitiesAnaheim, CAPhone 714.630.0012Fax 714.632.7133Hagerstown, MDPhone 301.223.6961Fax 301.223.6836Seguin, TXPhone 830.372.0090Fax 830.372.0321Tipton, IAPhone 563.886.6172Fax 563.886.2042ZCL Manufacturing FacilitiesEdmonton, ABPhone 800.661.8265Fax 780.466.6126Drummondville, QCPhone 800.661.8265Fax 780.466.6126Waverley, NSPhone 800.661.8265Fax 780.466.6126Hagerstown, MD
Most popular related searches
