ZIND Verfahrenstechnik

Filtration for Vacuum Pumps Catalog

Filtration for Vacuum PumpsCatalogue PMF002GBI2 Parker Hannifin UK LtdHermitage Court, Hermitage Lane, Maidstone, Kent ME16 9NT, EnglandPhone: +44 (0)1622 723 300 Fax: +44 (0)1622 728 703 E-mail: balstonukinfo@parker.com Web site: www.parker.com/balstonHydraulic, Lubrication & Coolant FiltrationHigh-performance filtrationsystems for production machineryin industrial, mobile andmilitary/marine applications.Finite and Balston Compressed Air & Gas FiltrationComplete line of compressedair/gas filtration and separationproducts; coalescing, particulateand adsorption filters and gasgenerators in many applicationsin many industries.Process & Chemical FluidFiltrationLiquid filtration systems for foodand beverage, petrochemical/chemical processing, paint, inksand coating, electronics, oilfieldand water.Racor Fuel Conditioning & FiltrationParker air, fuel and oil filtrationsystems provide quality protectionfor engines operating in anyenvironment, anywhere in theworld.System ContaminationMonitoringOn-line dynamic particle analysis,off-line bottle sampling and fluidanalysis and measurement ofwater content polluting the oil inthe system.Consistent QualityTechnical InnovationPremier Customer ServiceParker’s technical resources provide the correct filtrationtechnologies that conform to your requirements.That’s why thousands of manufacturers and equipment usersaround the world rely on Parker Filtration and people.Worldwide Sales and ServiceParker Filtration’s global reputation as a reliable supplier ofsuperior filtration products is the result of a focused andintegrated development and manufacturing system.Parker Filtration consolidates quality filtration products intoone broad based range that covers many markets andapplications.Products are backed by Parker’s commitment to premiercustomer and technical service worldwide.Member of British Compressed Air SocietyWhere RequiredParker Filtration3Parker Hannifin UK LtdHermitage Court, Hermitage Lane, Maidstone, Kent ME16 9NT, EnglandPhone: +44 (0)1622 723 300 Fax: +44 (0)1622 728 703 E-mail: balstonukinfo@parker.com Web site: www.parker.com/balstonProtecting Vacuum Pumps and Protecting from Vacuum Pump ExhaustsParker Filtration ......................................................................2Vacuum Pump Inlet Filters for Vacuum Service to 10-6 Torr ....................................................4Vacuum Pump Inlet Filters for Vacuum Service to 2 Torr ........................................................5Vacuum Pump Exhaust Filters for Non-Hazardous/Non-Corrosive Applications ........................6Vacuum Pump Exhaust Filters for Hazardous/Corrosive Applications ........................................8Recommended ExhaustFilters for Vacuum PumpsAlcatel Pumps............................................................................9Balzers Pumps ..........................................................................9Beach-Russ Pumps ................................................................10Busch Pumps ..........................................................................10Central Scientific Pumps (Cenco, Boekel, HYVAC) ................11Edwards High Vacuum Pumps ..............................................11Gast Pumps ............................................................................12Hitachi ......................................................................................12Ingersoll-Rand Pumps ............................................................12ITT Pneumotive (Leiman Brothers) ........................................13Kinney Pumps..........................................................................13Lammert Pumps ....................................................................13Leybold Heraeus......................................................................14Marvac Pumps ........................................................................14Maxima Pumps (Fisher Scientific)..........................................14Precision Scientific Pumps ....................................................15Quincy Pumps..........................................................................15Rietschle Pumps......................................................................15RO-FLO Pumps (Allis-Chalmers) ..........................................16Sargent-Welch Pumps ............................................................16Stokes Pumps..........................................................................17Ulvac Pumps ............................................................................17Varian Pumps ..........................................................................17Pump to Filter Adaptors ........................................................18Filter and Dryers for OEM Solutions ....................................194 Parker Hannifin UK LtdHermitage Court, Hermitage Lane, Maidstone, Kent ME16 9NT, EnglandPhone: +44 (0)1622 723 300 Fax: +44 (0)1622 728 703 E-mail: balstonukinfo@parker.com Web site: www.parker.com/balstonProtect vacuum pumps from damage bysolids and liquidsPrevent loss of valuable or hazardousmaterialsPrevent oil backstreamingModel CF-0112 and CF-0118 for VacuumService to 10-6 TorrStainless steel housings with welded KF flange inlet andoutlet ports and no drain ports. They are designed to be usedprimarily with the Grade 102 adsorbent cartridges forprevention of oil backstreaming (see cartridge selection chartbelow). They may also be used with Grade 30 cartridges forremoval of high concentrations of solids, but the absence ofdrain ports precludes the use of CF housings for liquidremoval in vacuum applications.Vacuum Pump Inlet Filters for Vacuum Service to 10-6 TorrFilter Selection ChartGrade 30 Cartridges For removal of relatively high concentrations of solidsEfficiency: 90% at 0.1 micron Loss in Pumping Speed: 9% at maximum flow rateMaterials of Construction: Polypropylene cartridge, EPR seals Maximum Temperature: 82ºC (180ºF) Grade 102 Cartridges For prevention of oil backstreaming and filtration of relatively low concentrations of solidsEfficiency for Preventing 99.99%Oil Backstreaming:Life: Approximately 1,000 hours at 10 microns vacuum Efficiency for Solids Filtration: 99.99% at 0.1 micron Materials of Construction: Molecular Sieve Type 4A adsorbent, EPR seals Maximum Temperature: 38ºC (100ºF)Principal SpecificationsModel CF-0112 CF-0118Recommended Vacuum Service 10-6 Torr 10-6 TorrMax. Flow Rating of Vacuum Pump 5 m3/hr (3 CFM) 15 m3/hr (9 CFM)Inlet and Outlet Ports KF-25 KF-25Materials of Construction:Head 304 SS 304 SSBowl 304 SS 304 SSInternals 304 SS 304 SSSeals None NoneMaximum Temperature 82ºC (180ºF) (1) 82ºC (180ºF) (1)Shipping Weight 0·2 kg 0·4 kgDimensions 70 x 110 mm 100 x 150 mmNotes:1 Maximum temperature grade 102 Cartridge is 38ºC (100ºF). 2 Filter Cartridge is permanently sealed into housing. The entire unit is disposable.Ordering InformationAssembly with Grade 30 Particulate Filter Assembly with Grade 102 Backstreaming FilterCF-0112-30 CF-0112-102CF-0118-30 CF-0118-1025Parker Hannifin UK LtdHermitage Court, Hermitage Lane, Maidstone, Kent ME16 9NT, EnglandPhone: +44 (0)1622 723 300 Fax: +44 (0)1622 728 703 E-mail: balstonukinfo@parker.com Web site: www.parker.com/balstonFilter Selection ChartGrade 30 Cartridges For removal of relatively high concentrations of solids and liquidsEfficiency: 90% at 0.1 micron Loss in Pumping Speed: 9% at maximum flow rateMaterials of Construction: Polypropylene cartridge, EPR seals Maximum Temperature: 82ºC (180ºF)Principal SpecificationsModel CV-0112-30 CV-0118-30 18/18-30Recommended Vacuum Service 2 Torr 2 Torr 2 TorrMax. Flow Rating of Vacuum Pump 5 m3/hr (3 CFM) 15 m3/hr (9 CFM) 15 m3/hr (9CFM) (1)Inlet and Outlet Ports 1/2” NPT 3/4” NPT 3/4” NPTDrain Port (2) 1/8” NPT 1/8” NPT 1/8” NPTMaterials of ConstructionHead 304 SS 304 SS SteelBowl 304 SS 304 SS SteelInternals 304 SS 304 SS SteelSeals None None NoneMaximum Temperature 82ºC (180ºF) 82ºC (180ºF) 82ºC (180ºF)Shipping Weight 0.2 kg 0.4 kg 1 kgDimensions 70 x 110 mm 100 x 150 mm 100 x 140 mmOrdering InformationAssembly with Grade 30 Particulate FilterCV-0112-30CV-0118-3018/18-30Notes:1 For higher flow capacity inlet filters, please consult factory.2 Drain port must be downward for liquid removal.3 Filter cartridge is permanently sealed into housing. The entire unit is disposable.Vacuum Pump Inlet Filters for Vacuum Service to 2 TorrProtect vacuum pumps from damage bysolids and liquidsPrevent loss of valuable or hazardousmaterialsPrevent oil backstreamingModels CV-0112-30 and CV-0118-30 forhazardous/corrosive applications and lowflow applicationsStainless steel housings with NPT inlet, outlet and drainports. Used only with Grade 30 filter cartridges.Model 18/18-30 for non-hazardous/non-corrosive applications and higher flowapplicationsSteel housing with NPT inlet, outlet and drain ports. Usedonly with Grade 30 filter cartridges.6 Parker Hannifin UK LtdHermitage Court, Hermitage Lane, Maidstone, Kent ME16 9NT, EnglandPhone: +44 (0)1622 723 300 Fax: +44 (0)1622 728 703 E-mail: balstonukinfo@parker.com Web site: www.parker.com/balstonFilter Selection Chart (for non-hazardous/non-corrosive applications)Max. Pump Recommended Filter Model Number Flow Rate (m3/hr)5 9955-12-371H, 9956-12-371H15 18/18-371H34 AR-0316-371H73 AR-0335-371H170 AR-0735-371H 340 AR-0780-371H510 AR-1280-371H 765 AR-1680-371H1,444 AR-3080-371HNote: The suffix “30” indicates the filter cartridge grade. For removal of high concentrations of solids and liquids use “30” suffix. For prevention of oil backstreaming andfiltration of low solids concentrations, use “102” suffix.Vacuum Pump Exhaust Filters for Non-Hazardous/Non-Corrosive ApplicationsEliminate 99.99% oil mist and smoke fromvacuum pump exhaustPrevent oil accumulation in ductworkRecover expensive lubricating oils, andautomatically return filtered oil to pumpEliminate potential health and safetyviolationsBalston Vacuum Pump Exhaust FiltersBalston Vacuum Pump Exhaust Filters remove all visible oilmist and smoke from vacuum pump exhaust, even when it issaturated with oil. The high efficiency filter cartridgecontinuously drains the collected liquid, allowing the user torecover expensive lubricating fluid. Filters are available forpumps with flow ratings to 1,444 m3/hr (850 CFM).How To Select The FilterFor most applications, simply select the filter assembly whichhas a flow capacity equal to or greater than the vacuum pumpexhaust flow output (see chart below). The filter assembliesare shipped with filter cartridges, pressure gauge (34 m3/hrand larger), and final filter pad. Optional adaptors areavailable for KF and NW connections (see Pg 18).7Parker Hannifin UK LtdHermitage Court, Hermitage Lane, Maidstone, Kent ME16 9NT, EnglandPhone: +44 (0)1622 723 300 Fax: +44 (0)1622 728 703 E-mail: balstonukinfo@parker.com Web site: www.parker.com/balstonOrdering InformationModel No. of Filter Replacement Filter Cartridges Cover (2) No. Pressure Relief Cartridges Box of 3 Box of 7 Box of 10 (Optional) Retainers #20222Required9955-12-371H (3) 3/9955-12-371H 9955-12-371H (4)9956-12-371H (3) 3/9956-12-371H 9956-12-371H (4)18/18-371H (3) (4)AR-0316-371H 3 3/200-16-371H 19158 1AR-0335-371H 3 3/200-35-371H 19158 1AR-0735-371H 7 7/200-35-371H 19206 2AR-0780-371H 7 7/200-80-371H 19206 2AR-1280-371H 12 200-80-371H Included 4AR-1680-371H 16 200-80-371H Included 4AR-3080-371H 30 200-80-371H Included 6Optional Accessories#20222 Pressure Relief Filter Cartridge Retainer, 4-7 psig.#20222 Pressure Relief Filter Cartridge Retainer, 2-5 psi.#20217 Pressure Relief Valve, 3-7 psig, 1/4” NPT male fitting.#11010 Pressure Gauge, 0-15 psig, 1/4” male fitting (incl. on Type AR Filter Assemblies)Vacuum pump-to-filter adaptors#19291 Stand for AR-1680-371H, #19290 Stand for AR-3080-371H.#19202 Weather Cap for AR-0735-371H, AR-0780-371H.Vacuum Pump Exhaust Filters for Non-Hazardous/Non-Corrosive ApplicationsPrincipal Specifications9955-12-371H 9956-12-371H 18/18-371H AR-0316-371H AR-0335-371HPort Size 1/2” NPT KF-16 3/4” NPT 1” NPT 1 1/2” NPTMax. Flow Rate 5 m3/hr (3 CFM) 5 m3/hr (3 CFM) 15 m3/hr (9 CFM) 34 m3/hr (43 CFM) 73 m3/hr (43 CFM)Materials ofConstruction:Head Steel SteelBowl Nylon Nylon Steel Steel SteelSeals None None Viton Buna/Neo Buna/NeoMax. Temp. 121ºC (250ºF) 121ºC (250ºF) 204ºC (400ºF) 204ºC (400ºF) 204ºC (400ºF) Max. Press. 1 bar(g) 1 bar(g) 1 bar(g) 1 bar(g) 1 bar(g)Shipping Wt. 0.1 kg 0.1 kg 0.4 kg 4 kg 5 kgDimensions 50 x 94 mm 50 x 94 mm 89 x 137 mm 188 x 224 mm 188 x 381 mmAR-0735-371H AR-0780-371H AR-1280-371H AR-1680-371H AR-3080-371HPort Size 3” NPT 3” NPT 4” Flg. (1) 4” Flg. (1) 6” Flg. (1)Max. Flow Rate 170 m3/hr (100 CFM) 340 m3/hr (200 CFM) 510 m3/hr (300 CFM) 765 m3/hr (450 CFM) 1,444 m3/hr (850 CFM)Materials of Construction:Head Steel Steel Steel Steel SteelBowl Steel Steel Steel Steel SteelSeals Buna/Neo Buna/Neo Buna/Neo Buna/Neo Buna/NeoMax. Temp. 204ºC (400ºF) 204ºC (400ºF) 204ºC (400ºF) 204ºC (400ºF) 204ºC (400ºF) Max. Press. 1 bar(g) 1 bar(g) 1 bar(g) 1 bar(g) 1 bar(g)Shipping Wt. 8 kg 10 kg 41 kg 45 kg 68kgDimensions 254 x 457 mm 254 x 711 mm 483 x 1,092 mm(5) 483 x 1,092 mm(5) 584 x 1,092 mm(5)Notes:1 ANSI 150 lb. hole pattern.2 Cover does not provide leak tight seal.3 Filter cartridge is permanently sealed into housing. The entire unit is disposable.4 Pressure relief filter tube retainer not available in these models.5 Height dimension represents filter housing alone. When assembled with a stand, the height is adjustable from 1,170 to 1,420 mm.8 Parker Hannifin UK LtdHermitage Court, Hermitage Lane, Maidstone, Kent ME16 9NT, EnglandPhone: +44 (0)1622 723 300 Fax: +44 (0)1622 728 703 E-mail: balstonukinfo@parker.com Web site: www.parker.com/balstonPrincipal SpecificationsModel CV-0112-371H CV-0118-371H ACV-0135-371H ACV-0735-371H ACV-0780-371HPort Size 1/2” NPT 3/4” NPT 1” NPT 2” NPT 2” NPTMax. Flow Rate 5 m3/hr (3 CFM) 15 m3/hr (9 CFM) 34 m3/hr (20 CFM) 170 m3/hr (100 CFM) 340 m3/hr (200 CFM)Materials of ConstructionHead 304 SS 304 SS 304 SSBowl 304 SS 304 SS 304 SS 304 SS 304 SSInternals 304 SS 304 SS 304 SS 304 SS 304 SSSeals None None Viton Viton VitonMaximum Temperature 121ºC (250ºF) 121ºC (250ºF) 121ºC (250ºF) 121ºC (250ºF) 121ºC (250ºF)Maximum Pressure 1 bar(g) 1 bar(g) 1 bar(g) 1 bar(g) 1 bar(g)Shipping Weight 0.2 kg 0.4 kg 4.3 kg 25 kg 32 kgDimensions 70 x 110 mm 100 x 130 mm 100 x 580 mm 250 x 740 mm 250 x 960 mmVacuum Pump Exhaust Filters for Hazardous/Corrosive ApplicationsEliminate 99.9% oil mist and smoke fromvacuum pump exhaustPrevent oil accumulation in ductworkRecover expensive lubricating oils, andautomatically return filtered oil to pumpEliminate potential OSHA and EPA violationsParker Vacuum Pump Exhaust FiltersParker Vacuum Pump Exhaust Filters remove all visible oil mistand smoke from vacuum pump exhaust, even when it issaturated with oil. The high efficiency filter cartridgecontinuously drains the collected liquid, allowing the user torecover expensive lubricating fluid. Filters are available forpumps with flow ratings ranging from 5 to 340 m3/hr (200 CFM).How To Select The FilterFor most applications, simply select the filter assembly whichhas a flow capacity equal to or greater than the vacuum pumpexhaust flow output (see chart below). The filter assembliesare shipped with filter cartridges, pressure gauge (34 m3/hrand larger), and final filter pad. Optional adaptors areavailable for KF and NW connections (see page 18).Ordering InformationModel CV-0112-371H (1) CV-0118-371H (1) ACV-0135-371H ACV-0735-371H ACV-0780-371HNumber of Filter Cartridges Required 1 7 7Replacement Filter Cartridges:Box of 3 3/200-35-371HBox of 7 7/200-35-371H 7/200-80-371HBox of 10 200-35-371HNumber of Pressure Relief Retainers #20222 1 2 2Optional Accessories: #11015 Back Pressure Gauge, Stainless Steel, 0-15 psi rating, 1/4” NPT fitting.Vacuum Pump-to-Filter Adaptors: Please refer to Page 18.Notes:1 Filter cartridge is permanently sealed into housing. The entire unit is disposable. Pressure relief filter tube retainer not available in these models.Filter Selection Chart (for hazardous/corrosive applications)Max. Pump Recommended Flow Rate (m3/hr) Filter Model Number5 CV-0112-371H15 CV-0118-371H34 ACV-0135-371H170 ACV-0735-371H340 ACV-0780-371H9Parker Hannifin UK LtdHermitage Court, Hermitage Lane, Maidstone, Kent ME16 9NT, EnglandPhone: +44 (0)1622 723 300 Fax: +44 (0)1622 728 703 E-mail: balstonukinfo@parker.com Web site: www.parker.com/balstonRecommended Exhaust Filters for Vacuum PumpsRecommended Recommended BalstonPump Exhaust Parker Filter Balston Anodized Balston Filter StainlessPump Rating (NPT Female Non-Hazardous Aluminium Pump Hazardous Steel Pump(Free Air) Unless Otherwise Non-Corrosive -To- Filter and Corrosive -To- FilterPump Model No. m3/hr CFM Noted) Applications Adaptor (1) Applications Adaptor (1)Alcatel PumpsZM/ZT 1004A/AC 5 3 NW 25 18/18 14175 CV-0112 14182ZM/ZT 1012A 19 11 NW 25 AR-0316 14173 ACV-0135 14177ZM/ZT 1030 29 17 1” OD Tube AR-0316 ACV-0135ZM/ZT 1033 46 27 NW 40 AR-0335 14174ZT 1060 51 30 1.63” OD Tube AR-0335ZT 1063 85 50 NW 40 AR-0735 14174 (2) ACV-0735 14178 (3)ZT 1200A 255 150 1.63” OD Tube AR-0780 ACV-0780ZM/ZT 2004A 5 3 NW 25 18/18 14173 CV-0112 14182ZM/ZT 2007 12 7 NW 25 18/18 14173 CV-0118 14182ZM/ZT 2008A/AC 12 7 NW 25 18/18 14173 CV-0118 14182ZM/ZT 2012A/AC/H 19 11 NW 25 AR-0316 14173 ACV-0135 14177UM/UT 2020 27 16 NW 25 AR-0316 14173 ACV-0135 14177ZM/ZT 2030/H 29 17 1” OD Tube AR-0316 ACV-0135ZM/ZT 2033/C 46 27 NW 40 AR-0335 14174ZT 2060/H/HUS 51 30 1.63” OD Tube AR-0335ZT 2063/C 85 50 NW 40 AR-0735 14174 (2) ACV-0735 14178 (3)ZT 2100A/AC 153 90 NW 50 AR-0735 ACV-0735 14179 (3)Balzers PumpsUNO/DUO 1.5A 2 1.0 KF10 9955-12 CV-0112UNO/DUO 004A/B 5 3 KF25 9955-12 14175 CV-0112 14182UNO/DUO 008A/B 9 5 KF25 18/18 14173 CV-0118 14182UNO/DUO 012A 14 8 KF25 18/18 14173 CV-0118 14182UNO/DUO 016B 18 11 KF25 AR-0316 14173 ACV-0135 14177UNO/DUO 030A 34 20 KF40 AR-0316 14174 ACV-0135 14178 (5)UNO/DUO 060A 67 40 KF40 AR-0335 14174UNO/DUO 250A 267 157 ISO 100 AR-0780 ACV-0780UNO 100 95 56 32mm OD Tube (4) AR-0735 ACV-0735DUO 100 97 57 32mm OD Tube (4) AR-0735 ACV-0735UNO/DUO 120A 127 75 ISO 63 AR-0735 ACV-0735UNO 170 155 91 32mm OD Tube (4) AR-0735 ACV-0735DUO 170 170 100 32mm OD Tube (4) AR-0735 ACV-0735BA 251 270 159 ISO 63 AR-0780 ACV-0780BA 501 545 321 ISO 100 AR-1680 ACV-0780 (6)Notes:1 If no part number is listed, adaptor is not supplied by Parker. In most cases, customer can assemble adaptor from standard pipe fittings. Refer to page 19.2 Requires 3” Male x 1 1/2” Female reducing bushing supplied by customer.3 Requires 2” Male x 1 1/2” Female reducing bushing supplied by customer.4 Exhaust port is horizontal. Customer should provide elbow so that filter is mounted vertically.5 Requires 1” Male x 1 1/2” Female bushing supplied by customer.6 Multiple filters piped in parallel are required.10 Parker Hannifin UK LtdHermitage Court, Hermitage Lane, Maidstone, Kent ME16 9NT, EnglandPhone: +44 (0)1622 723 300 Fax: +44 (0)1622 728 703 E-mail: balstonukinfo@parker.com Web site: www.parker.com/balstonRecommended Recommended BalstonPump Exhaust Parker Filter Balston Anodized Balston Filter StainlessPump Rating (NPT Female Non-Hazardous Aluminium Pump Hazardous Steel Pump(Free Air) Unless Otherwise Non-Corrosive -To- Filter and Corrosive -To- FilterPump Model No. m3/hr CFM Noted) Applications Adaptor (1) Applications Adaptor (1)Beach-Russ PumpsSS 1 10 6 3/4” 18/18 CV-0118SS 1 15 9 3/4” 18/18 CV-0118SS 2 25 15 3/4” AR-0316 ACV-0135SS 3 48 28 1” AR-0335SS 4 77 45 1 1/4” AR-0735 ACV-0735SS 5 102 60 1 1/2” AR-0735 ACV-0735RP/RV 6 14 8 1/2” 18/18 CV-0118SS 6 127 75 1 1/2” AR-0735 ACV-0735SS 7 187 110 2” AR-0780 ACV-0780SS 8 255 150 2 1/2” AR-0780 ACV-0780SS 9 382 225 4” AR-1280 ACV-0780 (2)SS 10 637 375 6” AR-1680 ACV-0780 (2)RP/RV 12 31 18 3/4” AR-0316 ACV-0135RP 15 51 30 1 1/2” AR-0335RP 15-6 51 30 1” AR-0335RP 30 85 50 1 1/2” AR-0735 ACV-0735RP 30-6 85 50 1” AR-0735 ACV-0735RP 50/50-6 136 80 2” AR-0735 ACV-0735RP 135/135-12 238 140 3” AR-0780 ACV-0780RP-150/150-12 297 175 3” AR-0780 ACV-0780RP 250 527 310 5” AR-1280 ACV-0780 (2)RP 250-12 527 310 4” AR-1280 ACV-0780 (2)RP 325 637 375 5” AR-1680 ACV-0780 (2)RP 325-12 637 375 4” AR-1680 ACV-0780 (2)RP 375 850 500 6” AR-3080 ACV-0780 (2)RP 375-50 850 500 4” AR-3080 ACV-0780 (2)RP 750 1,529 900 8” AR-1680 (2) ACV-0780 (2)RP 750-50 1,529 900 5” AR-1680 (2) ACV-0780 (2)RP 1000 1,869 1,100 8” AR-3080 (2) ACV-0780 (2)RP 1000-50 1,896 1,100 5” AR-3080 (2) ACV-0780 (2)Busch Pumps002-192 2 1 KF-16 9956-12 CV-0112 14181004-192 5 3 KF-16 9956-12 CV-0112 14181008-192 10 6 KF-16 18/18 14172 CV-0118 14181 (4)010-112/118 10 6 3/4” 18/18 CV-0118016-192 19 11 KF-16 AR-0316 14180 ACV-0135 14176016-112/118 14 8 3/4” (3) 18/18 CV-0118021-336/338 25 15 3/4” (3) AR-0316 ACV-0135025-132/138 34 20 1 1/4” (3) AR-0316 ACV-0135040-132/138 48 28 1 1/4” (3) AR-0335063-132/138 70 41 1 1/4” (3) AR-0335110-132/138 107 63 1 1/4” (3) AR-0735 ACV-0735160-112/118/132/138 199 117 2” (3) AR-0780 ACV-0780216-002 212 125 2” AR-0780 ACV-0780225-002 340 200 2” AR-0780 ACV-0780240-002 510 300 2” AR-1280 ACV-0780 (2)250-112/118/132/138 296 174 2” (3) AR-0780 ACV-0780263-002 850 500 2” AR-3080 ACV-0780 (2)400-212/218 510 300 2” AR-1280 ACV-0780 (2)630-212/218 731 430 3” (3) AR-1680 ACV-0780 (2)1000-212/228 1,104 650 6” (3) AR-3080 ACV-0780 (2)1600-212/228 1869 1,100 6” (3) AR-3080 (2) ACV-0780 (2)429 212 125 2” AR-0780 ACV-0780433 340 200 2” AR-0780 ACV-0780437 527 310 2” AR-1280 ACV-0780 (2)441 985 580 2” AR-3080 ACV-0780 (2)445 1,325 780 6” (3) AR-3080 ACV-0780 (2)Notes:1 If no part number is listed, adaptor is not supplied by Parker. In most cases, customer can assemble adaptor from standard pipe fittings. Refer to pages 18.2 Multiple filters piped in parallel are required.3 Requires flange to NPT adaptor from pump manufacturer.4 Requires 3/4” Male x 1/2” Female reducing bushing supplied by customer.Recommended Exhaust Filters for Vacuum Pumps11Parker Hannifin UK LtdHermitage Court, Hermitage Lane, Maidstone, Kent ME16 9NT, EnglandPhone: +44 (0)1622 723 300 Fax: +44 (0)1622 728 703 E-mail: balstonukinfo@parker.com Web site: www.parker.com/balstonRecommended Exhaust Filters for Vacuum PumpsRecommended Recommended BalstonPump Exhaust Parker Filter Balston Anodized Balston Filter StainlessPump Rating (NPT Female Non-Hazardous Aluminium Pump Hazardous Steel Pump(Free Air) Unless Otherwise Non-Corrosive -To- Filter and Corrosive -To- FilterPump Model No. m3/hr CFM Noted) Applications Adaptor (1) Applications Adaptor (1)Central Scientific Pumps (Cenco, Boekel, HYVAC)HYVAC 1 (91105) 0.6 0.35 3/8” 9955-12 CV-0112HYVAC 2 (91305/8) 1.5 0.88 1/2” 9955-12 CV-0112HYVAC 4 (91482) 3 2 1/2” 9955-12 CV-0112HYVAC 7(91506, 91502) 5 3 1/2” 9955-12 CV-0112HYVAC 7S (91138) 5 3 1/2” 9955-12 CV-0112HYVAC 14 (91705) 10 6 3/4” 18/18 CV-0118HYVAC 14S (91140) 10 6 3/4” 18/18 CV-0118HYVAC 28 (91905) 19 11 1 1/2” AR-0316 ACV-0135HYVAC 28S (91142) 19 11 1 1/2” AR-0316 ACV-0135HYVAC 45 (91955) 31 18 1 1/2” AR-0316 ACV-0135HYVAC 150 (91957) 90 53 3” AR-0735 ACV-0735HYVAC 300 (91960) 180 106 3” AR-0780 ACV-0780MEGAVAC (92003) 3 2 1/2” 9955-12 CV-0112PRESSOVAC (90510/15/16) 2 1 3.8” OD Tube 9955-12 CV-0112DIRECT DRIVE (90703) 4 2 3/8” 9955-12 CV-0112DIRECT DRIVE (90700) 2 1 3/8” 9955-12 CV-0112Edwards High Vacuum PumpsSPEEDIVAC 2 3 2 3/8 BSPT 9955-12 14157 CV-0112E2M1 2 1 3/8 BSPT 9955-12 14157 CV-0112E2M2 3 2 3/4 BSPT 9955-12 14158 CV-0112E1/E2M5 6 4 3/4 BSPT 18/18 14159 CV-0118EDM6 8 5 1/2” 18/18 CV-0118E1/E2M8 12 7 3/4 BSPT 18/18 14159 CV-0118EDM12 17 10 1/2” AR-0316 ACV-0135E1/E2M18 26 15 3/4” AR-0316 ACV-0135EDM20 26 15 1/2” AR-0316 ACV-0135E2M30 52 30 KF25 AR-0335 14183E1/E2M40 52 30 KF25 AR-0335 14183ED/ES 50 7 4 1/4” 18/18 CV-0118ED/ES65 3 2 1/4” (2) 9955-12 CV-0112E1/E2M80 97 57 KF25 AR-0735 14183 (2) ACV-0735 14177 (2)ED/ES100 6 4 1/4” (2) 18/18 CV-0118E1/E2M175 212 125 1 1/2” AR-0780 ACV-0780ED/ES200 12 7 3/8” (2) 18/18 CV-0118E1/E2M275 246 145 1 1/2” AR-0780 ACV-0780ES330 20 12 3/8” (2) AR-0316 ACV-0135ISC 450 34 20 1/2” AR-0316 ACV-0135ED 500 31 18 1/2” AR-0316 ACV-0135ED660 39 23 1/2” (2) AR-0335ISC 900 66 39 3/4” AR-0335ES2000 121 71 1 1/2” AR-0735 ACV-0735ES4000 246 145 1 1/2” AR-0780 ACV-0780ES7500 467 275 2 1/2” AR-1280 ACV-0780 (2)RV3 5 3 3/4” 9955-12 (2) CV-0112 (2)RV5 7 4 NW25 18/18 14173 CV-0118 14182RV8 12 7 NW25 18/18 14173 CV-0118 14182RV12 17 10 NW25 AR-0316 14173 ACV-0135 14177Notes:1 If no part number is listed, adaptor is not supplied by Parker. In most cases, customer can assemble adaptor from standard pipe fittings. Refer to pages 18.2 Exhaust port is horizontal. Customer should provide elbow so that filter is mounted vertically.3 Multiple filters piped in parallel are required.4 Reducing bushing required. Customer to provide.12 Parker Hannifin UK LtdHermitage Court, Hermitage Lane, Maidstone, Kent ME16 9NT, EnglandPhone: +44 (0)1622 723 300 Fax: +44 (0)1622 728 703 E-mail: balstonukinfo@parker.com Web site: www.parker.com/balstonRecommended Recommended BalstonPump Exhaust Parker Filter Balston Anodized Balston Filter StainlessPump Rating (NPT Female Non-Hazardous Aluminium Pump Hazardous Steel Pump(Free Air) Unless Otherwise Non-Corrosive -To- Filter and Corrosive -To- FilterPump Model No. m3/hr CFM Noted) Applications Adaptor (1) Applications Adaptor (1)Gast Pumps0211 2 1 1/4” 9955-12 CV-01120240 3 2 1/4” 9955-12 CV-01120322 5 3 1/4” 9955-12 CV-01120440 6 4 1/4” 18/18 CV-01180465 6 4 3/8” 18/18 CV-01180522 6 4 1/4” 18/18 CV-01180740 10 6 3/8” 18/18 CV-01180765 10 6 3/8” 18/18 CV-01180822 12 7 3/8” 18/18 CV-01181022 17 10 3/8” AR-0316 ACV-01351065 14 8 1/2” 18/18 CV-01181550 20 12 1/2” AR-0316 ACV-01352065 29 17 3/4” AR-0316 ACV-01352067 29 17 3/4” AR-0316 ACV-01352565 36 21 3/4” AR-03353040 53 31 1” AR-03354565 82 48 3/4” AR-0735 ACV-07355565 93 55 1” AR-0735 ACV-07354BA-1-G482X 3 2 1/2” 9955-12 CV-01124AB-1-G482X 3 2 1/2” 9955-12 CV-01124BA-1-G492X 3 2 1/2” 9955-12 CV-01124BA-1-G499 3 2 1/2” 9955-12 CV-01124BA-1-G511X 3 2 1/2” 9955-12 CV-01124BA-1-G538X 3 2 1/2” 9955-12 CV-01125BA-1-G482X 6 4 1/2” 18/18 CV-01185AB-1-G482X 6 4 1/2” 18/18 CV-01185BB-1-G482X 6 4 1/2” 18/18 CV-01186BA-1-G535X 12 7 1” 18/18 ACV-01356AB-1-G504X 12 7 1” 18/18 ACV-01357BA-1-G506X 19 11 1” R-0316 ACV-01357AB-1-G506X 19 11 1” R-0316 ACV-01358BA-1-G506X 24 14 1 1/4” R-0316 ACV-01358AB-G506X 24 14 1 1/4” R-0316 ACV-0135Hitachi PumpsSVF 10F 6 4 M24 x 1 18/18 14168 CV-0118SVR 16F 10 6 M24 x 1 18/18 14168 CV-0118100 VPS 6 4 M24 x 1 18/18 14168 CV-0118160 VPD/VPS 10 6 M24 x 1 18/18 14168 CV-011816 VP 10 6 M24 x 1 18/18 14168 CV-01183 VPC 3 2 M14 x 1 9955-12 CV-01124 VPC 6 4 M14 x 1 18/18 CV-0118Ingersoll-Rand PumpsAV/AVX2 5 3 3/8” 9955-12 CV-0112BV/BVX2 8 5 3/8” 18/18 CV-0118V23A/V23AX7 15 9 3/4” 18/18 CV-0118V235/V235X1 31 18 1” AR-0316 ACV-0135V244/V244X2 54 32 1 1/4” AR-0335V255/V255X3 102 60 1 1/2” AR-0735 ACV-0735V255X5 102 60 1 1/2” AR-0735 ACV-07357V/7VX5 168 99 1 1/2” AR-0735 ACV-073515V/15VX7 226 133 2” AR-0780 ACV-078020VX10 364 214 2 1/2” AR-1280 ACV-0780 (2)20V/20VX15 500 294 2 1/2” AR-1280 ACV-0780 (2)Notes:1 If no part number is listed, adaptor is not supplied by Parker. In most cases, customer can assemble adaptor from standard pipe fittings. Refer to pages 18.2 Multiple filters piped in parallel are requiredRecommended Exhaust Filters for Vacuum Pumps13Parker Hannifin UK LtdHermitage Court, Hermitage Lane, Maidstone, Kent ME16 9NT, EnglandPhone: +44 (0)1622 723 300 Fax: +44 (0)1622 728 703 E-mail: balstonukinfo@parker.com Web site: www.parker.com/balstonRecommended Recommended BalstonPump Exhaust Parker Filter Balston Anodized Balston Filter StainlessPump Rating (NPT Female Non-Hazardous Aluminium Pump Hazardous Steel Pump(Free Air) Unless Otherwise Non-Corrosive -To- Filter and Corrosive -To- FilterPump Model No. m3/hr CFM Noted) Applications Adaptor (1) Applications Adaptor (1)ITT Pneumotive (Leiman Brothers)B 17 10 3/4” AR-0316 ACV-0135C 31 18 1” AR-0316 ACV-013529-3J 34 20 1” AR-0316 ACV-0135195-2 34 20 3/4” AR-0316 ACV-0135C-3 37 22 1” AR-033530-3 59 35 1” AR-0335C-6 63 37 1 1/2” AR-033529-6J 85 50 1 1/2” AR-0735 ACV-073530-6 102 60 1 1/2” AR-0735 ACV-0735100 190 112 1 1/2” AR-0780 ACV-0780100J 212 125 1 1/2” AR-0780 ACV-0780107/107J 340 200 3’ AR-0780 ACV-0780Kinney PumpsKC/KVS/KVC-2 3 2 3/4” 9955-12 CV-0112KC/KVC-3 5 3 3/4” 9955-12 CV-0112KC-5 8 5 3/4” 18/18 CV-0118KVC-6 10 6 3/4” 18/18 CV-0118KC-8 14 8 3/4” AR-0316 ACV-0135KS-13 22 13 1 1/4” AR-0316 ACV-0135TCS-14 24 14 3/4” AR-0316 ACV-0135KC-15 25 15 1 1/4 AR-0316 ACV-0135KS-15 25 15 1 1/4” AR-0316 ACV-0135KTC-21 36 21 1” AR-0335TCS-21 36 21 3/4” AR-0335KD-30 56 33 1 1/4” AR-0335TCS-35 51 30 1 1/4” AR-0335 14174KD-50 88 52 1 1/4” AR-0735 ACV-0735TCS-55 92 54 1 1/2” AR-0735 ACV-0735KTC-60 102 60 1 1/2” (2) AR-0735 ACV-0735KDH-65 117 69 1 1/2” AR-0735 ACV-0735TCS-70 121 71 1 1/2” AR-0735 ACV-0735KDH-80 141 83 1 1/2” AR-0735 ACV-0735TCS-90 150 88 2” AR-0735 ACV-0735KTC-112 182 107 2” (2) AR-0780 ACV-0780KDH-130 228 134 2” AR-0780 ACV-0780KDH-150 280 165 2” AR-0780 ACV-0780KT-150 244 144 2” (2) AR-0780 ACV-0780KTC-225 375 221 3” (2) AR-1280 ACV-0780 (3)KT-300 503 296 3” (2) AR-1280 ACV-0780 (3)KT-500 839 494 3” (2) AR-3080 ACV-0780 (3)KT-850 1,321 778 4” Flange AR-3080 ACV-0780 (3)Lammert Pumps10301 3 2 1/2” 9955-12 CV-011210302 3 2 1/2” 9955-12 CV-011210305/01131 8 5 3/4” 18/18 CV-011810307/01133 14 8 1” 18/18 CV-011810310/02131 17 10 1” AR-0316 ACV-013502133 25 15 3/4” AR-0316 ACV-013503131/03231 34 20 1 1/4” AR-0316 ACV-013504231/04131 51 30 1 1/4” AR-033503133/03233 51 30 1 1/4 AR-033504133/04233 85 50 1 1/4” AR-0735 ACV-073505131/05231 127 75 2” AR-0735 ACV-073506231/05133/05233 170 100 2” AR-0735 ACV-073507231 212 125 3” AR-0780 ACV-078006233/08231 255 150 3” AR-0780 ACV-078007233 340 200 3” AR-0780 ACV-078008233/09231 425 250 3” AR-1280 ACV-0780 (3)09233 595 350 3” AR-1680 ACV-0780 (3)Notes:1 If no part number is listed, adaptor is not supplied by Parker. In most cases, customer can assemble adaptor from standard pipe fittings. Refer to pages 18.2 Exhaust port is horizontal. Customer should provide elbow so that filter is mounted vertically.3 Multiple filters piped in parallel are required.Recommended Exhaust Filters for Vacuum Pumps14 Parker Hannifin UK LtdHermitage Court, Hermitage Lane, Maidstone, Kent ME16 9NT, EnglandPhone: +44 (0)1622 723 300 Fax: +44 (0)1622 728 703 E-mail: balstonukinfo@parker.com Web site: www.parker.com/balstonRecommended Exhaust Filters for Vacuum PumpsRecommended Recommended BalstonPump Exhaust Parker Filter Balston Anodized Balston Filter StainlessPump Rating (NPT Female Non-Hazardous Aluminium Pump Hazardous Steel Pump(Free Air) Unless Otherwise Non-Corrosive -To- Filter and Corrosive -To- FilterPump Model No. m3/hr CFM Noted) Applications Adaptor (1) Applications Adaptor (1)Leybold Heraeus PumpsD/S 2A 3 2 KF 16 9956-12 CV-0112 14181D/S 4A 8 5 KF 16 18/18 14172 CV-0118 14181 (3)D/S 8A 12 7 KF 25 18/18 14173 CV-0118 14182D 4B 5 3 KF 16 18/18 14172 CV-0118 14181 (3)D 8B 12 7 KF 16 18/18 14172 CV-0118 14181 (3)D/S 16A 24 14 KF 25 AR-0316 14173 ACV-0135 14177D25 34 20 KF 25 AR-0316 14173 ACV-0135 14177D/S 30A 46 27 KF 40 AR-0335 14178SV 40 51 30 1 1/4” AR-0335DK 50 54 32 KF 50 AR-0335D/S 60A 63 37 KF 40 AR-0335 14178D 65 90 53 KF 40 AR-0735 14174 (4) ACV-0735 14178 (2)SV 65 76 45 1 1/4” AR-0335 ACV-0335E 75 83 49 KF 50 AR-0735 ACV-0735 14179 (2)D/S 90A 93 55 KF 40 AR-0735 14174 (4) ACV-0735 14178 (2)DK 100 110 65 KF 50 AR-0735 ACV-0735 14179 (2)SV 100 119 70 2” AR-0735 ACV-0735E 150 160 94 KF 50 AR-0735 ACV-0735 14179 (2)SV 180 212 125 2” AR-0780 ACV-0780DK 200 130 221 3” ASA Flange AR-0780 ACV-0780E 250 162 275 3” ASA Flange AR-0780 ACV-0780SV 280 340 200 2” AR-0780 ACV-0780SV 500 318 540 3” AR-1280 ACV-0780 (5)SV 580 339 576 3” AR-1680 ACV-0780 (5)Marvac PumpsA-1 2 1 3/8” 9955-12 CV-0112A-2 2 1 3/8” 9955-12 CV-0112A-10 3 2 3/8” 9955-12 CV-0112A-20 3 2 3/8” 9955-12 CV-0112A-222 7 4 1/2” 18/18 CV-0118B-2 5 3 1/2” 9955-12 CV-0112B-3 10 6 3/4” 18/18 CV-0118B-6 34 20 1 1/4” AR-0316 ACV-0135B-20 7 4 1/2” 18/18 CV-0118B-30 15 9 1” 18/18 CV-0118B-222 12 7 3/4” 18/18 CV-0118R-10 3 2 3/8” 9955-12 CV-0112R-20 3 2 3/8” 9955-12 CV-0112R-22 5 3 3/8” 9955-12 CV-0112R-55 10 6 3/8” 18/18 CV-0118Maxima Pumps (Fisher Scientific)D2A (01-057-2A) 3 2 KF 16 9956-12 CV-0112 14181D4A (01-057-4A) 9 5 KF 16 18/18 14172 CV-0118 14181 (3)D8A (01-057-8A) 12 7 KF 25 18/18 14173 CV-0118 14182D16A (01-057-16A) 24 14 KF 25 AR-0316 14173 ACV-0135 14177D30A (01-057-30A) 46 27 KF 40 AR-0335 14174D60A (01-057-60A) 63 37 KF 40 AR-0335 14174 (4)D90A (01-057-90A) 93 55 KF 40 AR-0735 ACV-0735 14178 (2)Notes:1 If no part number is listed, adaptor is not supplied by Parker. In most cases, customer can assemble adaptor from standard pipe fittings. Refer to page 18.2 Requires 2” Male x 1 1/2” Female reducing bushing supplied by customer.3 Requires 3/4” Male x 1/2” Female reducing bushing supplied by customer.4 Requires 3” Male x 1 1/2” Female reducing bushing supplied by customer.5 Requires Multiple Filters piped in parallel.15Parker Hannifin UK LtdHermitage Court, Hermitage Lane, Maidstone, Kent ME16 9NT, EnglandPhone: +44 (0)1622 723 300 Fax: +44 (0)1622 728 703 E-mail: balstonukinfo@parker.com Web site: www.parker.com/balstonRecommended Exhaust Filters for Vacuum PumpsRecommended Recommended BalstonPump Exhaust Parker Filter Balston Anodized Balston Filter StainlessPump Rating (NPT Female Non-Hazardous Aluminium Pump Hazardous Steel Pump(Free Air) Unless Otherwise Non-Corrosive -To- Filter and Corrosive -To- FilterPump Model No. m3/hr CFM Noted) Applications Adaptor (1) Applications Adaptor (1)Precision Scientific PumpsDD-20 2 1 3/4” 9955-12 CV-0112D-25 2 1 3/4” 9955-12 CV-0112S/PV-35 2 1 3/4” 9955-12 CV-0112DD-50 3 2 3/4” 9955-12 CV-0112D-75 5 3 3/4” 9955-12 CV-0112DD-90 5 3 3/4” 18/18 CV-0118DD-100 6 4 3/4” 18/18 CV-0118D-150 8 5 3/4” 18/18 CV-0118DD/DDC-195 12 7 3/4” 18/18 CV-0118S/D-300 19 11 1” AR-0316 ACV-0135DD/DDC 310 19 11 3/4” AR-0316 ACV-0135DD/DDC 475 29 17 3/4” AR-0316 ACV-0135S/D-500 31 18 1 1/4” AR-0316 ACV-0135S/D-1000 59 35 1 1/2” AR-0335S/D-1500 90 53 1 1/2” AR-0735 ACV-0735Quincy PumpsQSVB-10 134 79 1 1/4” AR-0735 ACV-0735QSVB-20 227 134 1 1/4” AR-0780 ACV-0780QSVI-20 270 159 2 1/2” AR-0780 ACV-0780QSVI-40 535 315 2 1/2” AR-1280 ACV-0780 (2)Rietschle PumpsVAL/VL/VE 10 12 7 NW 25 18/18 14173 CV-0118 14182VF/VFE/CLFG 11 12 7 1/2” 18/18 CV-0118VF/VFE 16 17 10 1/2” AR-0316 ACV-0135CLFG/CLF/CLFE 16 17 10 1/2” AR-0316 ACV-0135VAL/VL/VLV 25 29 17 NW 25 AR-0316 14173 ACV-0135 14177VF/VFE 26 29 17 3/4” AR-0316 ACV-0135CLFG/CLF/CLFE 26 29 17 3/4” AR-0316 ACV-0135VL/VLV 40 51 30 NW 25 AR-0335 14183VF/VFE 41 46 27 3/4” AR-0335CLFG/CLF/CLFE 41 46 27 3/4” AR-0335VL/VLV 60 68 40 3/4” AR-0335VF/VFE 61 68 40 3/4” AR-0335CLFG/CLF/CLFE 61 68 40 3/4” AR-0335VL/VLV 80 92 54 NW 40 AR-0735 14174 (4) ACV-0735 14178 (5)VF/VFE 81 92 54 1 AR-0735 ACV-0735CLFG/CLF/CLFE 81 92 54 1 AR-0735 ACV-0735VL/VLV 100 114 67 NW 40 AR-0735 14174 (4) ACV-0735 14178 (5)VF/VFE 101 114 67 1 1/4” AR-0735 ACV-0735CLFG/CLF/CLFE 101 114 67 1 1/4” AR-0735 ACV-0735VWZ 102 114 67 NW 65 AR-0735 ACV-0735CLF/CLFE 141 160 94 1 1/2” AR-0735 ACV-0735VFH/VFEH 161 183 108 2 AR-0780 ACV-0780VWZ 162 183 108 NW 65 AR-0780 ACV-0780CLF/CLFE 181 183 108 2” AR-0780 ACV-0780VWZ 252 287 169 NW 65 AR-0780 ACV-0780CLFH/CLFEH 341 391 230 3” AR-1280 ACV-0780*VWZ 402 459 270 NW 65 AR-1280 ACV-0780*CLFH/CLFEH 501 574 338 3” AR-1680 ACV-0780*CLFH/CLFEH 631 724 426 3” AR-1680 ACV-0780*CLFH/CLFEH 1001 1,150 677 3” AR-3080 ACV-0780*Notes:1 If no part number is listed, adaptor is not supplied by Parker. In most cases, customer can assemble adaptor from standard pipe fittings. Refer to page 18.2 Multiple filters piped in parallel are required.3 Requires 1 1/2” Male x 1” Female reducing bushing supplied by customer.4 Requires 3” Male x 1 1/2” Female reducing bushing supplied by customer.5 Requires 2” Male x 1 1/2” Female reducing bushing supplied by customer.16 Parker Hannifin UK LtdHermitage Court, Hermitage Lane, Maidstone, Kent ME16 9NT, EnglandPhone: +44 (0)1622 723 300 Fax: +44 (0)1622 728 703 E-mail: balstonukinfo@parker.com Web site: www.parker.com/balstonRecommended Exhaust Filters for Vacuum PumpsRecommended Recommended BalstonPump Exhaust Parker Filter Balston Anodized Balston Filter StainlessPump Rating (NPT Female Non-Hazardous Aluminium Pump Hazardous Steel Pump(Free Air) Unless Otherwise Non-Corrosive -To- Filter and Corrosive -To- FilterPump Model No. m3/hr CFM Noted) Applications Adaptor (1) Applications Adaptor (1)RO-FLO Pumps (Allis-Chalmers)5CCA 93 55 1 1/2” AR-0735 ACV-07355CCB 146 86 1 1/2” AR-0735 ACV-07357DB 257 151 3” AR-0780 ACV-07807DC 399 235 3” AR-1280 ACV-0780 (2)8DB 467 275 3” AR-1280 ACV-0780 (2)8DE 586 345 3” AR-1680 ACV-0780 (2)10GB 698 411 4” AR-1680 ACV-0780 (2)10GC 1,008 593 4” AR-3080 ACV-0780 (2)11S 1,254 738 5” AR-308011L 1,424 838 5” AR-308012S 1,648 970 6” AR-3080 (2)12L 1,835 1,080 6” AR-3080 (2)17S 2,086 1,228 6” AR-3080 (2)17L 2,413 1,420 6” AR-3080 (2)19S 2,876 1,693 8” AR-3080 (2)19L 3,262 1,920 8” AR-3080 (2)23C 3,857 2,270 8” AR-3080 (2)23D 4,655 2,740 8” AR-3080 (2)27D 5,607 3,300 10” AR-3080 (2)33D 10,109 5,950 14” AR-3080 (2)Sargent-Welch Pumps1373 19 11 1-20 AR-0316 14163 ACV-01351374 39 23 1-3/4-20 AR-0335 141641375 59 35 Square Flange AR-03351376 19 11 1-20 AR-0316 (3) 14163 ACV-0135 (3)1380 10 6 1-20 18/18 14162 CV-01181392 2 1 3/4-20 9955-12 14165 CV-01121395 121 71 Square Flange AR-0735 ACV-07351396 170 100 Square Flange AR-0735 ACV-07351397 31 18 1-3/4-20 AR-0316 14160 ACV-01351398 90 53 Square Flange AR-0735 ACV-07351399 2 1 3/4-20 9955-12 14165 CV-01121400 2 1 3/4-20 9955-12 14165 CV-01121402 10 6 1-20 18/18 14162 CV-01181403 7 4 1-20 18/18 14162 CV-01181405 3 2 3/4-20 9955-12 14165 CV-01121410 2 1 1/2” Hose 9955-12 CV-01128802 2 1 3/4-20 9955-12 14165 CV-01128803B/8804B 2 1 3/4-20 9955-12 14165 CV-01128803K/8804K 2 1 3/4-20 9955-12 14165 CV-01128805 3 2 1-20 9955-12 14166 CV-01128806B/K 3 2 NW 25 9955-12 14175 CV-0112 141828810 7 4 1-20 9955-12 14166 CV-01188811B 7 4 NW 25 18/18 14173 CV-0118 141828811K 5 3 NW 25 9955-12 14175 CV-0112 141828814 10 6 NW 25 18/18 14173 CV-0112 141828815 8 5 1-20 18/18 14162 CV-01188816B/K 8 5 NW 25 18/18 14173 CV-0118 141828821 12 7 NW 25 18/18 14173 CV-0118 141828830 17 10 1-3/4-20 AR-0316 14160 ACV-01358834 20 12 NW 40 AR-0316 14174 ACV-0135 141848851 31 18 NW 40 AR-0316 14174 ACV-0135 141848861 59 35 NW 50 AR-0335 141798871 90 53 NW 50 AR-0735 14179 ACV-07358890 14 8 3/4-20 18/18 14173 CV-0118 141828905 3 2 NW 16 9956-12 CV-0112 141818910 7 4 NW 16 18/18 14172 CV-0118 14181 (4)8910A 5 3 NW 16 18/18 14172 CV-0118 14181 (4)8915 10 6 1-20 18/18 14162 CV-01188920 14 8 NW 25 18/18 14173 CV-0118 14182Notes:1 If no part number is listed, adaptor is not supplied by Parker. In most cases, customer can assemble adaptor from standard pipe fittings. Refer to page 18.2 Multiple filters piped in parallel are required.3 Consult factory for piping considerations.4 Requires 3/4” male x 1/2” female reducing bushing supplied by customer.17Parker Hannifin UK LtdHermitage Court, Hermitage Lane, Maidstone, Kent ME16 9NT, EnglandPhone: +44 (0)1622 723 300 Fax: +44 (0)1622 728 703 E-mail: balstonukinfo@parker.com Web site: www.parker.com/balstonRecommended Exhaust Filters for Vacuum PumpsRecommended Recommended BalstonPump Exhaust Parker Filter Balston Anodized Balston Filter StainlessPump Rating (NPT Female Non-Hazardous Aluminium Pump Hazardous Steel Pump(Free Air) Unless Otherwise Non-Corrosive -To- Filter and Corrosive -To- FilterPump Model No. m3/hr CFM Noted) Applications Adaptor (1) Applications Adaptor (1)Stokes PumpsV-005 12 7 NW 25 18/18 14173 CV-0118 14182V-009 19 11 NW 25 AR-0316 14173 ACV-0135 14177V-013-2 34 20 NW 40 AR-0316 14174V-017-2 63 37 NW 40 AR-0335 14174V-23 93 55 NW 40 AR-0735 14174 (3) ACV-0735 14178 (4)146H 51 30 1 1/4” AR-0335 ACV-0335148H 85 50 1 1/2” AR-0735 ACV-0735149H 136 80 1 1/2” AR-0735 ACV-0735149HS 170 100 1 1/2” AR-0735 ACV-0735212HS 255 150 2” AR-0780 ACV-0780412H 510 300 3” AR-1280 ACV-0780 (2)612H 1,020 600 3” AR-3080 ACV-0780 (2)912H 1,237 728 5” AR-3080 ACV-0780 (2)Ulvac PumpsG-5 0.3 0.2 M17 x 1 9955-12 CV-0112G-15 1.0 0.6 3/4” 9955-12 CV-0112G/GC-25S 1.3 0.8 3/4” 9955-12 CV-0112G/GC-20D 1.3 0.8 3/4” 9955-12 CV-0112G-50S/D 3 2 3/4” 9955-12 CV-0112GC-50D 3 2 3/4” 9955-12 CV-0112G-100S/D 6 4 1” 18/18 CV-0118GC-100D 6 4 1” 18/18 CV-0118GVD-050 3 2 3/4” 9955-12 CV-0112GVD-100 9 6 1” 18/18 CV-0118GVD-165 12 7 3/4” 18/18 CV-0118DA-30S 2 1 3/4” 9955-12 CV-0112DA-60S 5 3 3/4” 9955-12 CV-0112D-330D 15 9 1 1/2” 18/18 CV-0118D-650D 31 18 1 1/2” AR-0316 ACV-0135D-950D 46 27 2” AR-0335PKS-016 97 57 2” AR-0735 ACV-0735PKS-030 182 107 3” AR-0780 ACV-0780PKS-070 425 250 4” AR-1280 ACV-0780 (2)PVD-180 10 6 3/4” 18/18 CV-0118PDV-360 22 13 1” AR-0316 ACV-0135Varian PumpsCS/SS/SD-90 5 3 NW 25 18/18 14173 CV-0118 14182EVAC 200 12 7 3/4” 18/18 CV-0118EVAC 300 19 11 3/4” AR-0316 ACV-0135CD/SD-200 12 7 NW 25 18/18 14173 CV-0118 14182CD/SS/SD-300 19 11 NW 25 AR-0316 14173 ACV-0135 14177CD/SS/SD-700 46 27 NW 40 AR-0335 14174CD/SS/SD-1400 85 50 NW 40 AR-0735 14173 (3) ACV-0735 14178 (4)CD/SD-2500 153 90 NW 50 AR-0735 14179 (3) ACV-0735Notes:1 If no part number is listed, adaptor is not supplied by Parker. In most cases, customer can assemble adaptor from standard pipe fittings. Refer to page 18.2 Multiple filters piped in parallel are required.3 Requires 3” Male x 1 1/2” Female reducing bushing supplied by customer.4 Requires 2” Male x 1 1/2” Female reducing bushing supplied by customer.18 Parker Hannifin UK LtdHermitage Court, Hermitage Lane, Maidstone, Kent ME16 9NT, EnglandPhone: +44 (0)1622 723 300 Fax: +44 (0)1622 728 703 E-mail: balstonukinfo@parker.com Web site: www.parker.com/balstonPump to FilterAdaptorsPump to Filter Adaptors - Straight Thread to NPT ThreadPrincipal Specifications Type Adaptor Materials of Construction Dimensions (Inches)Style Adaptor Seals (A) Height (B) Hex Size (C) NPT Thread (D) Thread14168 1 Alum. Buna-N 3.0 1.25 3/4 M24 x 1 14166 2 Alum. Buna-N 2.6 1.25 1/2 F (1) 1-20 14165 2 Alum. Buna-N 2.44 1.25 1/2 F (1) 3/4-20 14164 3 Alum. Buna-N 2.88 2.0 1 1/2 1 3/4-20 14163 3 Alum. Buna-N 2.19 1.38 1 1-20 14162 1 Alum. Buna-N 3.0 1.25 3/4 1-20 14160 3 Alum. Buna-N 2.3 2.0 1 1 3/4-20 14159 1 Alum. 3.15 1.25 3/4 3/4 BSPT 14158 2 Alum. 2.80 1.25 1/2 F (1) 3/4BSPT 14157 2 Alum. 2.56 1.25 1/2 F (1) 3/8 BSPT Notes:1 Female NPT - all others Male Pump to Filter Adaptors - Flange to NPT ThreadPrincipal SpecificationsType Adaptor Materials of Construction Dimensions (inches) Other Fittings Included Style Adaptor Clamp Seals (A) (B) (C) Height NPT Thread KF Flange (2)14184 6 Stain. St. Alum. Viton 2.0 1 KF-40 14183 6 Alum. 2.38 1 1/2 KF-25 14182 4 Stain. St. 2.06 1/2 KF-25 3/4” x 1/2” Reducing Bushing 14181 4 Stain. St. 2.12 1/2 KF-16 14180 6 Alum. 2.0 1 KF-16 14179 6 Stain. St. 2.62 1 1/2 KF-50 14178 6 Stain. St. 2.38 1 1/2 KF-4014177 6 Stain. St. 2.0 1 KF-25 14176 6 Stain. St. 2.0 1 KF-16 14175 5 Alum. 2.0 1/2 F (1) KF-25 14174 6 2.0 1 KF-40 1 1/2” x 1” Reducing Bushing 14173 4 2.06 3/4 KF-25 1” x 3/4” Reducing Bushing 14172 4 2.12 1/2 KF-16 1/2” coupling and 3/4” x 1/2” Reducing Bushing Notes:1 Female NPT - all others are Male 2 The designation “KF” and “NW” are interchangeable ACBCO-RING1/4” N.P.T. PLUGACBDO-RING1/4” N.P.T. PLUG ACBDO-RINGABCCLAMPSEAL1/4” N.P.T. PLUGABCCLAMPSEALABCCLAMPSEAL1/4” N.P.T. PLUGA AStyle 4 Style 5 Style 619Parker Hannifin UK LtdHermitage Court, Hermitage Lane, Maidstone, Kent ME16 9NT, EnglandPhone: +44 (0)1622 723 300 Fax: +44 (0)1622 728 703 E-mail: balstonukinfo@parker.com Web site: www.parker.com/balstonFilters and Dryers for OEMSolutionsLet Parker join your OEM teamParker has a long experience of custom designing filters and dryers to suit the needs of original equipment manufacturers.Filter housings and configurations have been sized for a largenumber of requirements and the versatile range of Parkerfilter media means that virtually any filtration problem can besolved.Typical projects have included designing filter combinationsand mountings for compressor and dryer manufacturers, foodpackaging equipment manufacturers and pneumaticequipment suppliers.The Parker design team also specifies membrane air dryersto suit many dewpoint, pressure and flow requirements.Typical applications have included equipment for pressurisedcables, instrument quality air and any equipment where lowdewpoint air is critical. Call +44 (0)1622 723 300 for Technical Adviceon OEM applicationsTyreSaver is an example of the integrated approachParker follows in providing systems for OEMapplications - contact us to learn more.Membrane air dryers configured for OEMs offer a reliable and efficient alternative to pressure swing and refrigerantdryer technologies. Parker provides the compressed air treatment for your OEM application.Every effort has been made to ensure the accuracy of this document at the time of printing. In accordance with company’s policy of continued productimprovement Parker Hannifin UK Ltd reserves the right to make product changes without notice. No liability is accepted for any consequential losses,injury or damage resulting from the use of this document or from any omissions or errors herein. The data is given for guidance only. It does not constitutea specification or an offer for sale. The products are always subject to a programme of improvement and testing which may result in some changes in thecharacteristics quoted. As the products may be used by the client in circumstances beyond the knowledge and control of Parker Hannifin UK Ltd, wecannot give any warranty as to the relevance of these particulars to an application. It is the client’s responsibility to carry out the necessary tests todetermine the usefulness of the products and to ensure their safety of operation in a particular application. About the Parker Hannifin CorporationAerospace GroupA leader in the development,design, manufacture and service of control systems and components for aerospace and related high technology markets, achieving profitablegrowth through premier customer service. Automation GroupA leading supplier of pneumatic and electro mechanical components and systems to automation customers worldwide.Climate &Industrial Controls GroupDesigns, manufactures and markets system control and fluidhandling components and systems to refrigeration, air conditioning and industrial customers worldwide. Filtration GroupDesigns, manufactures and markets quality filtration andclarification products, providing customers with the best value,quality, technical support andglobal availability.Fluid ConnectorsGroupDesigns, manufactures and markets rigid and flexible connectors and associated products used in pneumatic andfluid systems. Hydraulics GroupDesigns, produces and markets a full spectrum of hydraulic components and systems tobuilders and users of industrial and mobile machinery and equipment.Instrumentation GroupA global leader in the design,manufacture and distribution of high quality critical flow components for worldwideprocess instrumentation, ultrahigh purity, medical and analytical applications.Seal GroupDesigns, manufactures and distributes industrial and commercial sealing devices and related products by providing superior quality andtotal customer satisfaction.Parker Hannifin CorporationFiltration and Separation Division100 Ames Pond Drive, PO Box 1262Tewksbury, MA 01876-0962 USAPhone: +1 800 343 4048Fax: +1 978 858 0625Parker Hannifin CorporationProcess Filter Division6640 Intech BlvdIndianapolis, IN 46278Phone: +1 317 275 8300Fax: +1 317 275 8410Parker Hannifin CorporationRacor Division3400 Finch RoadPO Box 3208Modesto, CA 95353 USAPhone: +1 800 344-3286Phone: +1 209 521-7860Fax: +1 209 529-3278Parker Hannifin CorporationHydraulic Filter Division16810 Fulton County Rd 2Metamora, OH 43540-9714 USAPhone: +1 419 644-4311Fax: +1 419 644-6205Parker Hannifin UK Ltd.Filter Division Europe HQ,Shaw Cross Business Park,Dewsbury, West YorkshireWF12 7RD UKPhone: +44 (0)1924 487 000Fax: +44 (0)1924 487 038Parker Hannifin Ind.eCom.Ltda.Filter DivisionVia Anhanguera, Km. 25,305276-977-Sao Paulo–SP, BrazilPhone: +55 (11) 3917 1407Fax: +55 (11) 3917 1623Parker Hannifin Asia Pacific Company, LTD902 Dae Heung Bldg.648-23 Yeoksam-dongKangnam-ku, Seoul,Korea 135-080Phone: +82 2 561 0414Fax; +82 2 556 8187Parker European Sales OfficesAustria +43 2622 235010Belgium +32 67 280900Czech Republic +420 2 83085221Denmark +45 43 560400Finland +358 3 54100France +33 254 740304Germany +49 2131 513350Hungary 36 1 2528137Italy +39 02 451921Netherlands +31 541 585000Norway +47 64911000Poland +48 22 8634942Spain + 34 91 6757300Sweden + 46 8 59795000Switzerland +41 22 3077111For information on any Parker product 00800 27 27 534DistributorCatalogue PMF002GBIRev 11Parker Hannifin UK Ltd Filter Division EuropeHermitage Court, Hermitage Lane, Maidstone, Kent ME16 9NT, UKPhone: +44 (0)1622 723 300 Fax: +44 (0)1622 728 703E-mail: balstonukinfo@parker.com Web site: www.parker.com/balstonFiltration Group TechnicalSales & Service LocationsEuropean ProductInformationCentreMember of British Compressed Air SocietyWhere RequiredMember of
Most popular related searches