Wilger Inc.

Flow Indicators

Seeing is KnowingFLOW VIEW™Ball FlowIndicators letyou see theliquid flow whenyou can’t see the nozzlesor outletsBetter Engineered Sprayer Components for over 35 YearsSee Your FlowA glance is all it takes to know that the correct amount of liquid is flowing to your spray nozzles or outletsMany ApplicationsCost Effective, modular, flexible configuration ball flow indicators• Sprayers and Fertilizer Applicators Use as a manifold and monitor flow to multiple nozzles or outlets.• Isolated Feed Applications With isolated feed applications, individual feed lines can be monitored. • Optional Metering Orifices Allow flows ranging from 0.004 to 8.0 USGPM to be metered. • Watering, Cooling and Air Systems Control and monitor flow in various branches of a liquid or air distribution system. Can be combined with WILGER COMBO-RATE® regulator and valve components.How They Work• Each Flow Indicator can supply liquid for up to three nozzles or outlets.• When the liquid is flowing equally the balls hover at the same level. • A ball that is lower than the others indicates the flow is too low due to a restriction or blockage. • A ball that is higher than the others indicates the flow is too high due to a leaking fitting or hose. Get Exactly What you NeedModular components ley you build a flow monitoringsystem that meets your specific requirementsCost Effective, modular, flexible configuration ball flow indicators• Modular design has individual columns and fittings which lets you build a system tailored specifically to meet your requirements.• Components are easy to assemble and service. • Wide flow range indicating capability: Low Flow model - 0.03 to 0.7 USGPM / Standard model - 0.05 to 2.7 USGPM • Molded from special UV and chemically resistant material, stays clear longer than PVC.• Components are interchangeable with other indicator brands.• Accommodates a wide range of liquid viscosities.Isolated Feed Flow Indicators• Allow individual feed lines to be monitored.• Individual Flow Indicators fit together, so fewer mounting fasteners are required.• Metering orifices can be utilized to control flow.• Ideal for squeeze pump applications.• Utilize O-ring seal & U-clip for outlet fitting.• Hose barb, NPTF and push-in outlet fittings available.• Radialock inlet fitting accepts wide range of Radialock cap fittings. Manifold Flow Indicators• Multiple Flow Indicators can be connected together so that one feed hose can supply multiple outlets.• Connect multiple bodies together with WILGER’s innovative O-ring seal and U-clip.• Up to 3 nozzles or openers can be monitored by a single flow indicator. • Metering orifices can be utilized to control flow.• Utilize O-ring seal and U-clip for inlet and outlet fittings.• Wide range of inlet and outlet fittings available.NEWFLOW VIEW™ Flow Indicator Assemblies, Fittings, Components, Metering Orifices and AccessoriesMakers of Better EngineeredSprayer Components for over 35 YearsSPECIFICATIONSMaterials:Indicator Body: UV & chemically resistantFittings: Polypropylene and Celcon®Indicator Balls: Polypropylene (orange & green); Celcon (red); Glass (maroon); Stainless Steel (7/16” & 1/2”) O-ring Seal: Buna-N or VitonU-Clip: Stainless steelMax operating pressure: 100 psi / 7 BarMax operating temperature: 185F / 85C Flow Indicator Body and Indicator Ball Selector GuidePART No.with BUNA-N-SEALwithVITONSEAL FLOW INDICATOR ASSEMBLY and PARTS20460-00 20460-V0 FLOW INDICATOR ASSY (Includes Body, Ball Retainer, O-Ring, 2 Lock U-Clips and Green, Red & 1/2” Stainless Steel Balls)20470-00 20470-00 FLOW INDICATOR ASSY - LOW FLOW (Includes Body, Ball Retainer, O-Ring, 2 Lock U-Clips; and Green, Red & 1/2” Stainless Steel Balls)20480-00* 20480-00* FLOW INDICATOR ASSY - ISOLATED FEED (Includes Body, Ball Retainer, 1 Lock U-Clip; and Green, Red & 20490-00* 20490-00* FLOW INDICATOR ASSY - ISOLATED FEED - LOW FLOW (Includes Body, Ball Retainer, 1 Lock U-Clip; and Green, 20460-01* 20460-01* FLOW INDICATOR BODY20470-01* 20470-01* FLOW INDICATOR BODY - LOW FLOW20480-01* 20480-01* FLOW INDICATOR BODY - ISOLATED FEED20490-01* 20490-01* FLOW INDICATOR BODY - ISOLATED FEED - LOW 20460-04* 20460-04* LOCK U-CLIP,302SS20460-02* 20460-02* BALL RETAINER20460-03 20460-15 O-RING - #212 (for Indicator Body and Fittings)*Seal Not ApplicableO-RING SEAL (ORS) FITTING ASSEMBLIES(includes required seals and/or U-clips)20501-00 20501-V0 ORS x HOSE BARB - STRAIGHT - 3/8”20502-00 20502-V0 ORS x HOSE BARB - STRAIGHT - 1/2”20503-00 20503-VO ORS x HOSE BARB - STRAIGHT - 3/4”20511-00 20511-V0 ORS x HOSE BARB - 90 DEGREE - 3/8”20512-00 20511-V0 ORS x HOSE BARB - 90 DEGREE - 1/2”20514-00 20514-V0 ORS x HOSE BARB - 90 DEGREE - 5/8”20513-00 20513-V0 ORS x HOSE BARB - 90 DEGREE - 3/4”20516-00 20516-V0 ORS MALE x 1/4” PUSH-IN TUBE - 90 DEGREE20517-00 20517-V0 ORS MALE x 3/8” PUSH-IN TUBE - 90 DEGREE20518-00 20518-V0 ORS MALE x 1/4” NPTF - 90 DEGREE20519-00 20519-V0 ORS MALE x 1/4” NPTFCONNECTOR TEES, STREET ELBOW and END CAP20520-00 20520-V0 ORS MALE x ORS FEMALE - 90 DEGREE20522-00 20522-V0 ORS MALE x ORS MALE x ORS FEMALE - TEE20523-00 20523-V0 ORS MALE x ORS FEMALE (BLIND) x 3/8” NPTF - 20524-00 20524-V0 ORS MALE x ORS FEMALE x 3/8” NPTF - TEE20525-00 20525-V0 ORS MALE x ORS MALE x 1” NPTF - TEE20526-00 20526-V0 ORS MALE x ORS MALE x ORS FEMALE - TEE w 1/4” 20521-00* 20521-00* ORS CAP20535-00* 20535-00* FITTING ASSEMBLY - ORS FEMALE x 1/4” NPTF20536-00* 20536-00* FITTING ASSEMBLY - ORS FEMALE x 3/8” NPTF20537-00* 20537-00* FITTING ASSEMBLY - ORS FEMALE x 1/2” NPTF*Seal Not ApplicableRADIALOCK INLET CAPS (ISOLATED FLOW MODELS)Requires 40261-00 Adapter when no pre-orifice is used40273-05* RADIALOCK CAP - 1/4” NPTF40274-05* RADIALOCK CAP - 1/4” NPTF, 45 DEGREE40277-05* RADIALOCK CAP - 1/8” NPTF40420-05* RADIALOCK CAP - 1/8” HOSE BARB40422-05* RADIALOCK CAP - 1/4” HOSE BARB40424-05* RADIALOCK CAP - 3/8” HOSE BARB40426-05* RADIALOCK CAP - 1/2” HOSE BARB40435-05* RADIALOCK CAP - 1/4” TUBE ADAPTER40436-05* RADIALOCK CAP - 3/8” TUBE ADAPTER40260-00 40260-V0 NOZZLE SEAL (VITON recommended for fertilizer)40261-00 SEAL / STRAINER ADAPTERFLOW INDICATOR BALLSSee Flow Indicator Body and Indicator Ball Selector Chart20460-13 BALL-FLOW INDICATOR - ORANGE POLYPROPYLENE20460-08 BALL-FLOW INDICATOR - GREEN POLYPROPYLENE20460-07 BALL-FLOW INDICATOR - RED CELCON20460-06 BALL-FLOW INDICATOR - MAROON GLASS20460-05 BALL-FLOW INDICATOR - 1/2” STAINLESS STEEL 30220460-10 BALL-FLOW INDICATOR - 7/16” STAINLESS STEEL 302FLOW VIEW CHECK VALVES andFLOW INDICATOR FLOW METERING ORIFICES21000-00 21000-V0 ORIFICE INSERT ASSEMBLY - BLANK21XXX-00 21XXX-V0 ORIFICE INSERT ASSEMBLY**40225-04 40225-05 O-RING - #015 (For Orifice Inserts)24000-00 24000-V0 CHECK VALVE ASSEMBLY24XXX-00 24XXX-V0 ORIFICE INSERT ASSEMBLY with CHECK VALVE****Please enquire for sizes and part numbersPART # BALL COLOR AND MATERIAL FLOW FLOW INDICATOR BODY FLOW RATE - USGPM20460-13 ORANGE POLYPROPYLENELOW 20470-00 and 20490-00 0.03 - 0.09STANDARD 20460-00 and 20480-00 0.05 - 0.1820460-08 GREEN POLYPROPYLENELOW 20470-00 and 20490-00 0.03 - 0.09STANDARD 20460-00 and 20480-00 0.05 - 0.1820460-07 RED CELCONLOW 20470-00 and 20490-00 0.05 - 0.14STANDARD 20460-00 and 20480-00 0.09 - 0.3020460-06 MAROON GLASSLOW 20470-00 and 20490-00 0.10 - 0.18STANDARD 20460-00 and 20480-00 0.31 - 0.7220460-05 1/2” STAINLESS STEEL 302LOW 20470-00 and 20490-00 0.15 - 0.70STANDARD 20460-00 and 20480-00 0.40 - 1.3320460-10 7/16” STAINLESS STEEL 302LOW 20470-00 and 20490-00 N/ASTANDARD 20460-00 and 20480-00 1.00 - 2.70Meter Your FlowMetering Orifices provide a simple, leak-free solution thateliminates the need for additional components.ball flow indicators• Orifice is placed into Flow Indicator outlet fitting.• Ribs on bottom of Metering Orifice prevent ball from restricting flow, eliminating need for Ball Retainer.• Orifices available to meter flows ranging from 0.004 to 8.0 USGPM.Orifice plate is also available as Check Valve (substitute 24xxx instead of 21xxx).To select a Metering Orifice from the chart below, follow these steps:Step 1/ Calculate the Flow Rate required per flow indicator with the following formula: Flow Rate = Application Rate (US gal/acre) x Speed (mph) x Outlet Spacing (inches) x # of Outlets per Flow Indicator x Conversion Factor* ÷ 5940 * The Metering Orifice selection chart is based on water. Fertilizer is more viscous than water, so a larger orifice is required for a given flow rate of fertilizer, compared to water. To determine the conversion factor for a given fertilizer, obtain the weight for one US gallon or the specific gravity of the fertilizer and select the applicable conversion factor below. The Conversion Factor can also be calculated using the Conversion Factor Calculator which is included with the Flow Indicator Ball and Metering Disc Selector, which can be downloaded from the FLOW VIEW Ball Flow Indicators section of the Downloads page of www.wilger.net. Step 2/ Select a Metering Orifice and operating pressure. On the chart below, locate the flow rates closest to your requirement. Select a Metering Orifice with an operating pressure in the middle of its range. Part Number Code: The 3 numbers following 21 are the orifice size in 0.000”; Suffix (XX): -00 for Buna, -V0 for Viton.Some orifice sizes are not shown. Please consult factory for additional orifice sizes.Weight (lbs/US Gallon) 10.00 10.50 11.00 11.50 12.00 12.50 13.00 13.50 14.00Specific Gravity 1.20 1.26 1.32 1.38 1.44 1.50 1.56 1.62 1.68Conversion Factor 1.10 1.12 1.15 1.17 1.20 1.22 1.25 1.27 1.30PartNumberPressure (psi)5 10 15 20 30 4021009-XX 0.004 0.005 0.006 0.007 0.009 0.01021011-XX 0.006 0.008 0.010 0.011 0.014 0.01621013-XX 0.008 0.011 0.013 0.016 0.019 0.02221015-XX 0.010 0.014 0.018 0.020 0.025 0.02921018-XX 0.015 0.021 0.025 0.029 0.036 0.04221020-XX 0.018 0.026 0.032 0.037 0.045 0.05221022-XX 0.022 0.031 0.037 0.043 0.053 0.06121025-XX 0.028 0.039 0.048 0.056 0.068 0.07921026-XX 0.030 0.043 0.052 0.060 0.074 0.08521028-XX 0.035 0.049 0.060 0.069 0.085 0.09821029-XX 0.038 0.054 0.066 0.077 0.094 0.1121031-XX 0.043 0.061 0.075 0.087 0.11 0.1221033-XX 0.052 0.073 0.090 0.10 0.13 0.1521035-XX 0.056 0.079 0.096 0.11 0.14 0.1621037-XX 0.061 0.086 0.11 0.12 0.15 0.1721039-XX 0.067 0.095 0.12 0.13 0.17 0.1921040-XX 0.072 0.10 0.13 0.14 0.18 0.2021043-XX 0.082 0.12 0.14 0.16 0.20 0.2321047-XX 0.097 0.14 0.17 0.19 0.24 0.2721049-XX 0.10 0.15 0.18 0.21 0.26 0.2921052-XX 0.12 0.17 0.21 0.24 0.29 0.3321053-XX 0.12 0.17 0.21 0.24 0.30 0.3521055-XX 0.13 0.19 0.23 0.27 0.33 0.3821057-XX 0.14 0.20 0.24 00.28 0.35 0.40PartNumberPressure (psi)5 10 15 20 30 4021060-XX 0.16 0.22 0.27 0.32 0.39 0.4521061-XX 0.16 0.23 0.29 0.33 0.40 0.4721063-XX 0.17 0.25 0.30 0.35 0.43 0.4921064-XX 0.18 0.25 0.31 0.36 0.44 0.5121065-XX 0.18 0.26 0.32 0.37 0.45 0.5221067-XX 0.20 0.28 0.34 0.39 0.48 0.5621070-XX 0.22 0.31 0.37 0.43 0.53 0.6121073-XX 0.23 0.33 0.40 0.47 0.57 0.6621075-XX 0.25 0.35 0.42 0.49 0.60 0.6921078-XX 0.27 0.39 0.47 0.54 0.67 0.7721081-XX 0.29 0.41 0.50 0.58 0.71 0.8221086-XX 0.33 0.47 0.57 0.66 0.81 0.9421089-XX 0.35 0.49 0.60 0.69 0.85 0.9821091-XX 0.37 0.52 0.64 0.74 0.91 1.0521093-XX 0.39 0.55 0.67 0.77 0.95 1.0921096-XX 0.42 0.59 0.72 0.83 1.02 1.1821097-XX 0.43 0.61 0.74 0.86 1.05 1.2121098-XX 0.44 0.62 0.76 0.88 1.08 1.2521103-XX 0.46 0.65 0.80 0.92 1.13 1.3021104-XX 0.48 0.68 0.83 0.96 1.17 1.3521107-XX 0.52 0.73 0.90 1.04 1.27 1.4721110-XX 0.55 0.77 0.95 1.09 1.34 1.5521113-XX 0.58 0.82 1.01 1.16 1.42 1.6421116-XX 0.61 0.86 1.05 1.22 1.49 1.72PartNumberPressure (psi)5 10 15 20 30 4021120-XX 0.63 0.89 1.09 1.26 1.54 1.7821125-XX 0.69 0.98 1.20 1.39 1.70 1.9621128-XX 0.72 1.02 1.25 1.45 1.77 2.0421130-XX 0.75 1.06 1.30 1.50 1.84 2.1221132-XX 0.78 1.10 1.34 1.55 1.90 2.1921136-XX 0.84 1.19 1.46 1.68 2.06 2.3821140-XX 0.89 1.26 1.55 1.79 2.19 2.5321144-XX 0.93 1.31 1.61 1.85 2.27 2.6221147-XX 0.95 1.35 1.65 1.90 2.33 2.6921150-XX 1.02 1.44 1.77 2.04 2.50 2.8921152-XX 1.05 1.49 1.82 2.10 2.58 2.9821156-XX 1.10 1.55 1.90 2.20 2.69 3.1121161-XX 1.16 1.63 2.00 2.31 2.83 3.2721166-XX 1.21 1.71 2.10 2.42 2.97 3.4321171-XX 1.33 1.88 2.30 2.66 3.26 3.7621177-XX 1.41 2.00 2.45 2.83 3.46 4.0021182-XX 1.47 2.08 2.55 2.95 3.61 4.1721187-XX 1.56 2.21 2.70 3.12 3.82 4.4121196-XX 1.73 2.45 3.00 3.46 4.24 4.9021205-XX 1.87 2.65 3.25 3.75 4.59 5.3021213-XX 2.02 2.85 3.49 4.03 4.94 5.7021218-XX 2.11 2.98 3.65 4.21 5.16 5.9621234-XX 2.45 3.47 4.25 4.91 6.01 6.9421250-XX 2.83 4.00 4.90 5.66 6.93 8.00Intended Use and Limits of UseWilger Ball Flow Indicators are designed to accommodate agricultural liquids, including water, fertilizers and pesticides. Wilger Flow Indicators are not designed to be used with flammable or combustible products. The maximum operating pressure (100 p.s.i.) and maximum operating temperature (185°F / 85°C) should not be exceeded. Use of Wilger Flow Indicators with liquids for which they are not designed to accommodate or pressures / temperatures in excess of maximum indicated limitations will void Wilger’s warranty and liability. If you are unsure of a specific application, please contact Wilger.Isolated Feed ModelsEach Flow Indicator is fed separately and locksto the adjacent Indicator at two locations.Manifold ModelsMultiple Flow Indicators are fed by a single line and lock to the adjacent Indicator with a U-clip.UNITED STATES255 Seahorse Drive Lexington, TN, USA 38351-6538Phone:(877)968-7695 / (731)968-7695Fax: (877)968-7613 / (731)968-7613E-Mail:wilgeresc@bellsouth.net www.wilger.netCANADASite 412, Box 280 RR#471st. St. Rd. & Highway 16WSaskatoon, SK, Canada S7K 3J7Phone: (306)242-4121 Fax: (306)242-4122E-Mail: info@wilger.net COMBO-JET®Tip-Caps andNozzle BodiesCOMBO-RATE®Bodies and TurretsCOMBO-RATE IIMulti-Nozzle ApplicationQUICK-NUT SSTFluid Supply SystemTIP WIZARDDigital Spray Tip SelectorBOOM END FLUSH VALVEQN-SST and TWS Styles*When mounting multiple units, measure the actual hole spacing to ensure correct hole placements.LockTabLockFitBoltU-clips lock Flow Indicators togetherBoltMakers of Better EngineeredSprayer Components for over 35 YearsNEWNominal distance between holesHole size to drillBolt size to use (+ mount thickness)1-9/16”9/32”1/4” x 2”+Authorized DealerPublication #10209-02Printed in Canada
Most popular related searches