Conservation Solutions Corporation

Flowmeter - 1800 Series - Condensate Meter Brochure

FLOWMETERENGINEERING MANUAL1800 SERIESFLOW MEASUREMENT & CONTROL SOLUTIONS415 Hope Avenue, PO Box 618, Roselle, NJ 07203Phone: (908) 241-8880 Fax: (908) 241-7288 www.istec-corp.com1PRODUCT OVERVIEWISTEC’s “Super-Jet” 1800 Series are industrial grade water meters available in ½” through 12” sizes.All sizes incorporate a variety of standard features such as U.S. gallon register, hermetically sealed non-resettable counter, trickle flow indicator and pulse output. ISTEC “Super-Jet” design leaves only theturbine immersed, resulting in reliable and long lasting performance.For easy installation, all ISTEC flow meters up to 1½’’ are available with union connections; 2’’ andlarger sizes are designed with standard flanges. The smooth running turbine, together with a self-aligning suspension bearing system and other innovative features provides superior reliability andaccuracy that meets or exceeds AWWA standards.In addition, a high temperature version (350ºF) of the 2”, 3” and 4” meters is available.COMPONENT DESCRIPTIONBODYPipe Size ½” (15mm) To 1½” (40mm) BrassPipes Size 2” (50mm) To 12” (300mm) Cast IronFLOW INSERTTurbine FiberglassTurbine Axle Chrome/Nickel/SteelBearing Material Stainless Steel/SapphireMagnetic Transfer Cobalt/SamariumGears, Axles, Screws Stainless SteelCOUNTERCalibration U.S. Gallons (Metric Available)Housing Plastic, Hermetically SealedGears PlasticAxles Chrome/Nickel/SteelENVIRONMENTALMaximum Temperature 248ºF (120ºC)Maximum Pressure 232 PSI (16 BAR)2TECHNICAL SPECIFICATIONSTYPICAL FLOWMETER ACCURACY CHART1800 1805 1810 1811 1815 1816 18200.13 gpm 0.22 gpm 0.4 gpm 0.4 gpm 0.7 gpm 0.7 gpm 0.88 gpm30 lph 50 lph 90 lph 90 lph 160 lph 160 lph 200 lph6.6 gpm 11 gpm 26.32 gpm 26.32 gpm 43.86 gpm 43.86 gpm 65.8 gpm1.5 m 3ph 2.5 m3ph 6 m3ph 6 m3ph 10 m3ph 10 m3ph 15 m3ph13.2 gpm 22 gpm 52.6 gpm 52.6 gpm 87.22 gpm 87.22 gpm 131.6 gpm3 m3ph 5 m3ph 12 m3ph 12 m3ph 20 m3ph 20 m3ph 30 m3phgal/pulse 1 1 1 1 1 1 10liters/pulse 1 1 1 1 1 1 10pounds 2.3 2.5 6.4 6.8 11.3 12.1 27.5kilograms 1 1.1 2.9 3.1 5.1 5.5 12.51825 1830 1835 1840 1845 1850 18552.64 gpm 14.09 gpm 5.26 gpm 26.32 gpm 43.86 gpm 53 gpm 66 gpm0.6 m3ph 3.2 m3ph 1.2 m3ph 6 m3ph 10 m3ph 12 m3ph 15 m3ph66.04 gpm 140.89 gpm 263.2 gpm 657.9 gpm 1096.5 gpm 1761 gpm 2642 gpm15 m3ph 32 m3ph 60 m3ph 150 m3ph 250 m3ph 400 m3ph 600 m3ph264.2 gpm 396.26 gpm 790 gpm 1535 gpm 2631 gpm 4400 gpm 5284 gpm60 m3ph 90 m3ph 180 m3ph 350 m3ph 600 m3ph 1000 m3ph 1200 m3phgal/pulse 10 10 10 100 100 100 100liters/pulse 10 10 10 100 100 100 100pounds 24.4 27.5 43.7 71.6 99.2 260.0 300.0kilograms 11.1 12.5 19.8 32.5 45 118 136P/NMAXFLOWRANGEMINCONTMINCONTMAXPULSEWEIGHTP/NPULSEWEIGHTFLOWRANGE3DIMENSIONSFlowmeter ½” to 1-1/2” Flowmeter 2” to 12”P/N 1800 1805 1810 1811 1815 1816 1820Size½’’(H)15mm¾” (A)20mm1" (H)25mm1" (D)25mm1½’’ (H)40mm1½’’ (D)40mm2"(H)50mmh3/4"20mm3/4"20mm1-3/4"45mm1-1/4"31mm2"50mm7/8"21mm3-1/4"83mmH3-3/4"95mm3-3/4"95mm5-1/2"140mm7-1/2"191mm6-1/4"155mm8-3/4"221mm7-1/8"180mmL4-1/2"114mm5"127mm10-1/4"260mm5-7/8"150mm11-7/8"300mm7-7/8"200mm10-1/2"270mmP/N 1825 1830 1835 1840 1845 1850 1855Size2"(A)50mm3"(A)80mm4"(A)100mm6"(A)150mm8"(A)200mm10"(A)250mm12"(A)300mmh3"75mm3-3/4"94mm4-3/8"110mm5-3/4"145mm6-3/4"172mm8"203mm9-1/2"241mmH5-1/2"141mm5-1/2"141mm7-7/8"200mm8-1/2"217mm8-1/2"217mm9-1/4"240mm10-1/4"260mmL7-7/8"200mm8-7/8"225mm9-7/8"250mm11-7/8"300mm13-3/4"350mm17-3/4"450mm19-3/4"502mmFlowmeter 1” & 1-1/2” Downflow4FLOWMETER SPECIFICATION: 1800 SERIESAS MANUFACTURED BY ISTEC CORPORATION415 HOPE AVENUE, ROSELLE, NJ 07203The contractor shall furnish and install as shown on the plans a multi-wing turbine type Flowmeter. TheFlowmeter shall be factory assembled, calibrated and tested, incorporating the following features:BODYThe Flowmeter shall have a line size of ______ inch(s)/________mm(s). The body shall be constructedof brass (from ½” (15mm) to 1-1/2” (40mm) sizes) or cast iron (from 2” (50mm) to 12” (300mm)).FLOW INSERTThe Flow Insert shall be the “single-jet” type on the ½” (15mm) and ¾” (20mm) sizes. It shall be the“multi-jet” style on the 1” (25mm) through 12” (300mm) sizes. The insert assembly shall be capable ofbeing replaced without removing the meter body.COUNTERThe unit shall have a hermetically sealed “dry-type” mechanical counter. The counter will read in U.S.gallons (cubic meters available) and shall be non-resettable.ACCURACYThe Flowmeter shall have an accuracy of + 1.5%.FLOW RANGEThe Flowmeter shall have a minimum flow rating of ______ gpm (_________ lph/or m3ph). It shallhave a continuous flow rating of________ gpm (________ m3ph). The peak flow, which the meter cannot be subjected to for more than one hour per day, shall be________ gpm (_________ m3ph).PULSERThe Flowmeter shall provide a “pulse” type output of 1 contact closure for every 1/10/100 gallon(s) offlow (metric counters provide 1 pulse for every 1/10/100 liters of flow).
Most popular related searches