Transcat, Inc.
- Home
- Companies & Suppliers
- Transcat, Inc.
- Downloads
- Fluke - 725 - Multifunction Process ...
Fluke - 725 - Multifunction Process Calibrator Datasheet
Fluke 725 Multifunction CalibratorSimply PowerfulThe new Fluke 725 Multifunction ProcessCalibrator is a powerful yet easy-to-use fieldcalibrator. Use the measure and source functionsto test and calibrate almost any processparameter.• Small, streamlined shape makes it easyto carry• Rugged, reliable design stands up to field use• Easy to read measure/source screen lets youview input and output simultaneously• Measure volts, mA, RTDs, thermocouples,frequency, and ohms to test sensors andtransmitters• Source/simulate volts, mA, thermocouples, RTDs,frequency, and ohms to calibrate transmitters• Measure/source pressure using any of 28Fluke 700Pxx Pressure Modules• Source mA with simultaneous pressuremeasurement to conduct valve and I/P tests• Support flow meter testing with frequencyand CPM functions• Perform fast linearity tests with auto step andauto ramp features• Power transmitters during test using loopsupply with simultaneous mA measurement• Store frequently-used test setups for later use• Backlight lets you work in poor light• Remote interface allows benchtop automatedoperations• Large battery capacity of four AA cells• Battery door for easy changesOrdering informationFluke 725 Multifunction Process CalibratorEach calibrator includes: TL75 Test Leads, AC70A TestClips, one pair of stackable test leads, Users Manualsappropriate to country of destination (English, plus threeof: French, German, Spanish, Italian, Dutch, Norwegian,Danish, Swedish, Finnish, Portuguese, Korean, Chinese,and Japanese), Statement of Quality Assurance Practices;CE, CSA, UL, and TÜV markings.V mALOOP100%25%25%RECALLC / FMEASSOURCESTORESETUPTC RTDV mAPROCESS CALIBRATORMULTIFUNCTION7250%Simultaneous Function Capability Channel A Channel B24.000 mA DC M M or S24.000 mA DC with 24V loop supply M100.00 mV DC M or S30.000V DC Measure M20.000V DC Measure 10.000V DC Source M or S15 to 3200 Ohms M or SThermocouple J, K, T, E, R, S, B, L, U, N M or SRTD Ni120; Pt100 (392); Pt100 (JIS);Pt100, 200, 500, 1000 (385) M or SPressure (requires Fluke 700PXX Modules) M M used as SFrequency; Squarewave, 1 CPM to10 kHz;fixed amplitude 5V p-p M or SM = Measure S = Source/SimulateFluke. Keeping your worldup and running.SpecificationsGeneral specificationsMaximum voltage: 30VStorage temperature: -40°C to 71°COperating temperature: 10°C to 55°CRelative humidity: 95% (10°C to 35°C); 75% (30°C to 40°C);45% (40°C to 50°C); 35% (50°C to 55°C)Shock: 30g, 11ms, half-sine shock (or 1meter drop test)Vibration: Random, 2g, 5-500 HzSafety: CSA C22.2 No. 1010.1:1992EMC: EN50082-1:1992 and EN55022:1994 Class BSize/weight: 96 x 200 x 47 mm (3.8 x 7.9 x 1.9 inches)650g (23 oz)Battery: Four AA alkaline batteries. Battery life: 25 hours typicalWarranty: Three yearsThermocouple accuracy specificationsResolutionJ, K, T, E, L, N, U 0.1°C, 0.1°FB, R, S 1°C, 1°FNotesAccuracy specifications include 0.2°C coldjunction uncertainty.Thermocouple Measure or SourceJ -200 to 0°C 1.0°C0 to 1200°C 0.7°CK -200 to 0°C 1.2°C0 to 1370°C 0.8°CT -200 to 0°C 1.0°C0 to 400°C 0.8°CE -200 to 0°C 0.9°C0 to 950°C 0.7°CR -20 to 0°C 2.5°C0 to 500°C 1.8°C500 to 1750°C 1.4°CS -20 to 0°C 2.5°C0 to 500°C 1.8°C500 to 1750°C 1.5°CB 600 to 800°C 2.2°C800 to 1000°C 1.8°C1000 to 1800°C 1.4°CL -200 to 0°C 0.85°C0 to 900°C 0.7°CU -200 to 0°C 1.1°C0 to 400°C 0.75°CN -200 to 0°C 1.5°C0 to 400°C 0.9°CSummary specifications (18°C to 28°C for one year)Temperature coefficient, -10°C to 18°C, 28°C to 55°C, ± .005% of range per °C.Function Range Resolution Accuracy NotesMeasure or SourceVoltage 0 to 100 mV 0.01 mV .02% Rdg + 2 LSD Max load, 1 mA0 to 10V (source) 0.01V0 to 30V (measure) 0.01VmA 0 to 24 0.001 mA .02% Rdg + 2 LSD Max load, 1000?mV (TC terminals) -10.00 mV to +75.00 mV .01 mV .025% of range + 1 LSDResistance 15? to 3200? 0.01? to 0.1? 0.10? to 1.0?Frequency 2.0 to 1000.0 CPM 0.1 CPM ± .05% For frequency source,1 to 1100 Hz 1 Hz ± .05% waveform is 5V p-p1.0 to 10.0 kHz 0.1 kHz ± .25% squarewave, -0.1V offsetLoop Supply 24V dc N/A 10%RTD Types, Ranges and AccuraciesMeasure SourceNi 120 -80°C to 260°C 0.2°C 0.2°CPt 100 - 385 -200°C to 800°C 0.33°C 0.33°CPt 100 - 392 -200°C to 630°C 0.3°C 0.3°CPt 100 - JIS -200°C to 630°C 0.3°C 0.3°CPt 200 - 385 -200°C to 250°C 0.2°C 0.2°C250°C to 630°C 0.8°C 0.8°CPt 500 - 385 -200°C to 500°C 0.3°C 0.3°C500 to 630°C 0.6°C 0.4°CPt 1000 - 385 -200°C to 100°C 0.2°C 0.2°C100°C to 630°C 0.2°C 0.2°CResolutionRTD 0.1°C, 0.1°FRTD ranges and accuracy specifications©1999 Fluke Corporation. All rights reserved.Subject to change without notice.1/99 C0211UEN Rev AThe universal hanger attaches to the meterand can be used by itself on a nail, hook,with a piece of rope or stiff wire.ToolPakTM for Fluke 80 Series IVDigital MultimetersHang your meter anywhere.Ordering InformationModel TPAK80-4: Includes the ToolPakaccessories kit (universalhanger, hook-and-loopstraps, magnet)Need technical assistance? Call:1-800-44-FLUKEToll-free in the U.S.(905) 890-7600 in Canada(425) 356-5500 other countriesFor more information to be sent toyou by fax, call 1-800-FLUKE-FAXin the U.S. and Canada. Or, visit ourWebsite at http://www.fluke.comFluke. Keeping your worldup and running.ToolPak’s magnet is used with theuniversal hanger and is strong enough tosecurely hold you meter.Two hook-and-loop straps are used withthe universal hanger and can be wrappedaround a pipe or beam.Now you can hang your meter almost anywhere withthe new Fluke ToolPakTM accessories kit. Designed towork exclusively with the new Fluke 80 Series IV,ToolPak includes a universal hanger, a magnet, and9-inch (43 cm) and 17-inch (23 cm) “hook-and-loop”hanger straps.The universal hanger is designed to fit into thespecial module on the back of the new Fluke 87-IVand 89-IV meters. The universal hanger allows you tohang your meter on a nail, hook or other object. Youcan add a piece of rope, flexible wire or cable to hangthe meter in almost any position.The 9-inch (43 cm) and 17-inch (23 cm) hook-and-loop straps are used with Fluke’s universal hanger towrap around and connect to a pipe, beam or any otherconvenient support structure.And finally, the special magnet accessory is designedto connect to either of the straps. The strong magnetaccessory will attach to an electrical panel, a metaldoorjamb or any other ferrous-type metal.With the universal hanger, two hook-and-loop strapsand the magnet, ToolPak solves almost any hangingand positioning problem you may face with your new80 Series IV meter. Call your local Fluke distributor andask for the TookPak accessory kit.©1998 Fluke Corporation. All rights reserved. C0208UEN 12/98 Rev A1Hanger insertsinto slot with tabextension facingout, for proper use.2 3Hanger inserts into slottab extension facing out,for proper use.KyleRectangle12 3LockPakTM for Fluke 80 Series IVDigital MultimetersDon’t let your meter walk away.Ordering InformationModel LPAK80-4: Includes the LockPakaccessoryNeed technical assistance? Call:1-800-44-FLUKEToll-free in the U.S.(905) 890-7600 in Canada(425) 356-5500 other countriesFor more information to be sent toyou by fax, call 1-800-FLUKE-FAXin the U.S. and Canada. Or, visit ourWebsite at http://www.fluke.comFluke. Keeping your worldup and running.LockPak is a security accessory thatlets you lock a Fluke 80 Series IV meterin place.The LockPak accessory easily fits into the back of the meter, once the rubberprobe holder is removed.Now you can take long-term, unattended measurementswithout the fear of your meter being “borrowed.”LockPak is a new security accessory that fits into theback of a Fluke 87-IV or Fluke 89-IV. When combinedwith a cable and padlock, the meter is secured in placeto reduce the threat of theft or loss.Made of polycarbonate, LockPak is very durable andshould last for years.LockPak is designed for use similar to lockout, tagoutprocedures, and is especially useful for long term,unattended logging situations with the Fluke 89-IVdigital multimeter.So don’t let your new Fluke meter walk away. Be sureto purchase a Fluke LockPak accessory.
Most popular related searches
