Hioki E.E. Corporation

FT3700-20/FT3701-20 - Infrared Thermometer Datasheet

FT3700-20/ FT3701-20Non-contact infrared thermometer featuring simple, one-touch measurementMeasure the average temperature inside a circle whose diameter is defined by the two indicated points.Example of a circuit-breaker(At a distance of approx. 1 m)f 52f 52f 83f 83FT3700-20 FT3701-20BrightINFRARED THERMOMETEREnvironmental Measuring InstrumentsChoose according to your measurement location. Two ModelsTwo ModelsSimulated measurementFT3701-20Long-focus, Precise-fieldFor measuring temperatureat a single point30 : 1Distance : SpotFT3700-20Long-focusFor measuring temperatureover a wide areaDistance : Spot12 : 1Identify the measurement location reliably.Identify the measurement location reliably. Two-pointTwo-pointlasermarkerlasermarkerHeadquarters : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 FAX +81-268-28-0568 http://www.hioki.co.jp / E-mail: os-com@hioki.co.jpHIOKI USA CORPORATION : TEL +1-609-409-9109 FAX +1-609-409-9108 http://www.hiokiusa.com / E-mail: hioki@hiokiusa.comAll information correct as of Jun. 8, 2012. All specifications are subject to change without notice. FT3700-20E1-26B Printed in JapanDISTRIBUTED BYHIOKI (Shanghai) Sales & Trading Co., Ltd. : TEL +86-21-63910090 FAX +86-21-63910360 http://www.hioki.cn / E-mail: info@hioki.com.cnBeijing Office : TEL +86-10-84418761 FAX +86-10-84418763 / E-mail: info-bj@hioki.com.cnGuangzhou Office : TEL +86-20-38392673 FAX +86-20-38392679 / E-mail: info-gz@hioki.com.cnShenzhen Office : TEL +86-755-83038357 FAX +86-755-83039160 / E-mail: info-sz@hioki.com.cnHIOKI INDIA PRIVATE LIMITED : TEL +91-731-6548081 FAX +91-731-4020083 E-mail: info@hioki.inHIOKI SINGAPORE PTE. LTD. : TEL +65-6634-7677 FAX +65-6634-7477 E-mail: info@hioki.com.sgNote: Company names and Product names appearing in this catalog are trademarks or registered trademarks of various companies.Laser Product Caution NoticeA caution label is attached to the thermometer.Be sure to observe the operating precautions on the label.Measurement focus D : Distance (mm) S : Spot (mm)Measurement temperature range -60.0 to 550.0 °C (-76 to 1022 °F)Guaranteed accuracy range is -35 to 500°C. (-31.0 to 932.0 °F)-60.0 to 760.0 °C (-76 to 1400 °F)Guaranteed accuracy range is -35 to 500°C. (-31.0 to 932.0 °F)Accuracy-60.0 to -35.1 °C (-76.0 to -31.1 °F) : Accuracy not specified-35.0 to -0.1 °C (-31.0 to 31.9 °F) : ±10%rdg.±2 °C0.0 to 100.0 °C (-32.0 to 212.0 °F) : ±2 °C100.1 to 500.0 °C (212.1 to 932.0 °F) : ±2%rdg.500.1 to 550.0 °C (932.0 to 1022 °F) (FT3700-20)500.1 to 760.0 °C (932.0 to 1400 °F) (FT3701-20) : Accuracy not specifiedAccuracy guarantee for temperature and humidity23 °C ±3 °C (73 °F ±5 °F)80% RH or less (non-condensating)Temperature coefficient Measurement accurary × 0.1/ °CResponse time 1 second (90%)Diameter of field of measurement83 mm at 1000 mm (Distance : Spot = 12 : 1)100 mm at 3000 mm (Distance : Spot = 30 : 1)Detection element ThermopileSighting Two-point laser marker Max 1mW (class 2), RedMeasurementwavelength8 to 14 µm[Thermal emissivity compensation]0.10 to 1.00 by steps of 0.01Additional FunctionsMAX/ MIN/ DIF (MAX-MIN)/ AVG measurement, Alarm function, Backlight functionOperating temperature and humidity0 to 50°C (32°F to 122°F), 80%RH or less (non-condensating)Storage temperature and humidity-10 to 50°C (14°F to 122°F), 80%RH or less (non-condensating)50 to 60°C (122°F to 140°F), 70%RH or less (non-condensating)Applicable standardsEMC : EN61326Laser : IEC60825-1 CLASS 2 LASER Power supplyLR03 alkaline battery × 2 [Continuous operating time: Approx. 140 hours](When laser marker and backlight are OFF)DimensionsApprox.48 W × 172 H × 119 D mm(1.89" W × 6.77" H × 4.69" D)(excluding projections)Mass Approx. 256 g (9.0 oz.) (including LR03 alkaline battery × 2)Accessories Instruction manual, LR03 alkaline battery × 2(supplied with this product for initial use only), Carrying case × 1FT3700-20 FT3701-20SpecificationsINFRARED THERMOMETER FT3700-20Long-focusEasily measure temperature in hazardous or unreachable locationsUsefulFunctionsl MAX, MIN, DIF (MAX-MIN), AVG measurementl Alarm function l Emissivity (e) can be set based on the measurement targetl Continuous measurement l BacklightTEMPERATURE HiTESTER 3444(With real-time output, narrow field measurement type)TEMPERATURE HiTESTER 3445(With real-time output, fine surface measurement)Use a Temperature HiTester with output for continuous temperature measurement applications.l Measure a broad range of temperatures quickly and accurately at a resolution of 0.1°C.l Use the optional INTERFACE PACK 3909 to output measurement data in real time for use by a recorder or computer.Related ProductsSD(Long-focus)D : S=12 : 1FT3700-20 f 167 f 83 f 5550010002000(Long-focus, Precise-field)D : S=30:1FT3701-20f 52100030006000f 200f 100SDBLACK BODY TAPE(50mm×10m, 1 roll) Withstands 180? e=0.95*Optional use of black body tape allows increased emissivity in order to obtain accurate temperature measurements on low-emissivity materials such as metals.OptionINFRARED THERMOMETER FT3701-20Long-focus, Precise-field(Accuracy guaranteed for 1 year)Locations that pose the risk of electric shockLocations that pose the risk of electric shockUnreachable locationsUnreachable locationsLocations that cannot be touched due to moving partsLocations that cannot be touched due to moving parts
Most popular related searches