Diamond Scientific - Authorized Distributor
- Home
- Companies & Suppliers
- Diamond Scientific - Authorized ...
- Downloads
- G150-00N CO2 Analyzer For Indoor Air ...
G150-00N CO2 Analyzer For Indoor Air Quality - Product Datasheet
850 South Via Lata, Suite 112, Colton, CA 92324 • Phone (909) 783-9472 • Fax (909) 825-0591 www.viasensor.comG150CO2 INDOOR AIR QUALITY ANALYZERAIR QUALITY CHECK ANALYZERG150New CO2 analyzer designed to monitor CO2 for all indoor air quality applications. This unit has been developed to incorporate the latest technology and specification requirerments, that provide the user with a fast, simple-to-use and accurate piece of environmental field kit.Applications• General IAQ• Environmental Site Audits • Laboratories • MedicalFeatures• CO2 0 – 10,000 ppm• Options for:– O2 0 – 100%– Dual temperature probes 32°F – 122°F (0 – 50°C)– Data storage and download– Humidity Sensor 0 – 100%Benefits• Improved accuracy on CO2 readings• Quick verification of CO2 levels for site audits• Time saving with dual temperature probes• Data logging for long-term application• Easy to read large well-lit display• Built in gas moisture removalDiamond Systems LLC • Authorized Distributor • 55 East Broad St., Titusville, Florida 32796Phone (321) 223-7500 • Fax (321) 747-0316 • www.viasensor.info G150 GAS RANGES Gases Measured CO2By custom dual wavelength infra-red with reference channelO2 (Optional) By internal electrochemical cell Oxygen cell lifetime Approximately 3 years in air Range CO2O20-20%0-100% Measurement Accurancy GasCO2Accuracy: ± (1% range + 2% of reading) at reference conditions1Temperature dependence: ± 0.2% reading /°C (typical at 5% CO2)Pressure dependence: ± 0.02% of reading / hPa (typical at 5% CO2)O2± 1.0% Full Scale @ constant temperature and pressure± 2.0% Full Scale over operating temperature range Response time T90 CO2 = 20 seconds= 60 seconds Temperature (Optional) x2 using optional probes 32°F to +122°F (0°C to +50°C) Temperature accuracy, typical ± 0.2°C from 32 to 44°C, ± 0.5°C over the rest of the range Barometric pressure 800 - 1200 mbar RH measurement (Optional) RH Probe 0 - 100% RH non condensing RH accuracy ±1.5% RH across the range Visual and audible alarm User selectable CO2 and O2 alarm levels Communications USB type B mini-connector, HID device class Data Storage 1000 reading sets + 270 events FACILITIES ENVIRONMENTAL CONDITIONS Operating temperature 41°F – 104°F (5°C – 40°C) Relative humidity 0 - 95% non condensing (RH Probe 0 - 100% non condensing Barometric pressure ± 500mbar from calibration pressure PHYSICAL Weight 18 oz. (495 grams) Size L 6½" x W 4" x D 2 3/16" (L 165mm, W 100mm, D 55mm) Technical Specifications 1Conditions during factory calibration, typically 20°C, 1000mbarDiamond Systems LLC • Authorized Distributor 55 East Broad St., Titusville, Florida 32796Phone (321) 223-7500 • Fax (321) 747-0316 • www.viasensor.infoMasterTypewritten TextProduct designs and specifications are subject to change without notice. User is responsible for determining suitability of product.
Most popular related searches
