G200-00N N2O Analyzer For Medical Applications - Product Datasheet

850 South Via Lata, Suite 112, Colton, CA 92324 • Phone (909) 783-9472 • Fax (909) 825-0591 www.viasensor.comG200N2O, 0–1000PPM GAS ANALYZERMEDICAL STAFF SAFETYG200The G200 N2O analyzer is designed to safety check background and breathing zone levels of N2O (0–1000ppm) in medical applications.Applications• Operating theatres• Dental practices• Veterinary clinics • X-ray departments Features• 0 – 1000 ppm N2O• Storage for 1000 readings• TWA calculated• EH40 occupational exposure limits calculated • Leak detection• User settable alarms• Data download for graphing and reportingBenefits• Accurate verification of exposure limit breaches • Dual purpose background analyzer or personal analyzer. • Leak detection for N2O storage• Highly portableDiamond Systems LLC • Authorized Distributor • 55 East Broad St., Titusville, Florida 32796Phone (321) 223-7500 • Fax (321) 747-0316 • www.viasensor.info G200 Technical SpecificationsRelated ProductG210Used to audit check piped medical gases in hospitals, including N2O, 02, CO2 and CO. POWER SUPPLY Battery type Li Ion Battery life > 10 hours (8 hours with pump) Battery lifetime > 300 cycles Battery charger 5v DC external power supply and internal charging circuit Charge time < 3 hours Alternative power USB connectorDC power supply GAS RANGES Gases measured N2O By custom dual wavelength infra-red cell with reference channel Range N2O 0 - 1,000ppm0 - 10,000ppm (leak detection mode) Measurement accuracy GasN2O Resolution: 1ppmAccuracy: ± (1.5% of range + 2% of reading) at reference conditions1Temperature dependence: ± 2ppm /°C (typical at 100ppm N2O)Pressure dependence: ± 0.1% of reading/ hPa (typical at 100ppm N2O) Response time, T90 N2O = 40 seconds 1 Conditions during factory calibration, typically 20°C, 1000mbar FACILITIES Visual and audible alarm User selectable N2O and TWA alarms Communications USB type B mini-connector, HID device class Data Storage 1000 reading sets + 270 events50 site ID’s and 300 sample point ID’s PUMP Flow 100cc/ min typically (300cc/ min MAX) ENVIRONMENTAL CONDITIONS Operating temperature 41°F – 104°F (5°C – 40°C) Barometric pressure 500 to 1500mb Relative humidity 5% to 95% non condensing IP rating IP40 PHYSICAL Weight 18 oz. (500 grams) Size L 6½" x W 4" x D 2 3/16" (L 165mm, W 100mm, D 55mm)Diamond Systems LLC • Authorized Distributor 55 East Broad St., Titusville, Florida 32796Phone (321) 223-7500 • Fax (321) 747-0316 • www.viasensor.infoMasterTypewritten TextProduct designs and specifications are subject to change without notice. User is responsible for determining suitability of product.
Most popular related searches