KELMA NV
- Home
- Companies & Suppliers
- KELMA NV
- Downloads
- Gravimat - Model SHC500 - Gravimetric ...
Gravimat - Model SHC500 - Gravimetric Dust Concentration Measuring Device Brochure
SHC500GRAVIMATMobile measurement system for gravimetric dust concentration measurementP R o d u C T I n f o R M AT I o n2 G R AV I M AT S H C 5 0 0 | S I C k SHC500 Gravimat –Simple construction, precise measurement, fast resultsVersion 1: • LC collectors for low (0.1 ... 200 mg/m3) Version 2: • HC collectors for high (50 ... 50,000 mg/m3) dust concentrationsThe dust collectors are fitted with • suitable round filters before mea-surements and form a sealed unit during the complete measuring process including weighing proce-dures.Probe head with integrated support • for the dust collector, pressure measuring openings for isokinetic control of the extraction process, and a PT100 sensor for precise measurement of the exhaust gas temperature Stainless steel probe shaft• Multi-channel hose with integrated • impulse lines for transmission of the pressure signals to the pres-sure sensors in the electronic unitFlight case with:Electronic unit• 6 Pressure sensors• Power supply• Suction pump• Control valve, stop valve• Condensate separator• d u S T C o l l e C T o R f I lT e R H e A d P R o b e G S 5 A u T o M AT I C u n I TA R e A S o f A P P l I C AT I o nCalibration of continuous dust measurement systems• Performance measurements at filter plants• Compliance measurements• Flow and temperature profile measurements, determi-• nation of the flow direction (swirl)P e R f o R M A n C e f e AT u R e SNo dust losses during filter handling, patented sampling • systemHighest measuring accuracy especially at low level dust • concentrations Automatic data recording and system control• Isokinetic control in real time• Automatic storage and evaluation of the measuring val-• uesMeasurement results immediately available after sam-• plingAutomatic measurement of spin angles• Compact design, low number of components• Only one person for transport and handling• 3S I C k | G R AV I M AT S H C 5 0 0M e A S u R I n G P R I n C I P l eG R AV I M AT S Y S T e M o V e R V I e WA partial volume fl ow, regulated with a control valve by adding false air isokinetically based on the re-corded differential pressure, is ex-tracted from the duct by using a dust collector with fi lter, a fi lter head probe and a condensate se-perator. Gas velocity as well as gas fl ow angle to the probe can be cal-culated from these values. Tempe-rature is recorded by an integrated PT100 sensor within the probe head.A cut-off valve prevents a back fl ow to the dust collector before and af-ter sampling. The extracted partial volume fl ow is measured using fl ow measurement with restriction.Simple connection of fi lter head probe and automatic unit by screw lock gasket mechanismSpecial bracketTemperature sensorHC dust collectorLC dust collectorAutomatic unitFilter head probe GS5SICK MAIHAK GmbH | GermanyNimburger Str. 11 | 79276 Reute | www.sick.comPhone +49 7641 469-0 | Fax +49 7641 469-1149 | info.pa@sick.de 8007741/2009-06 · DIV03/KE · Printed in Germany (2009-08) · Subject to change without prior noticeTechnical data SHC500 GRAVIMATMeasuring parametersMeasuring components Dust concentration with gravimetrical comparison measurementMeasuring ranges 0.1 ... 200 mg/m• 3 with dust collector LC50 ... 50,000 g/m• 3 with dust collector HCAccuracy ± 1 % of maximum throughputMeasuring conditionsMedium temperature Standard: 0 ... 250 °C (32 … 480 °F) • With air cooling: 0 ... 400 °C (32 … 700 °F) • Special version: 0 ... 600 °C (32 … 1,110 °F) • Internal duct pressure –70 ... +70 hPa (–1.0 … 1.0 psi)Gas velocity 2 ... 48 m/s (6.6 … 157.5 ft/sec)Ambient conditionsUmgebungstemperatur –10 ... +50 °C InterfacesInterface RS232: 9600, N, 8, 1General informationSystem components Automatic unit SHC-AE501/502• Filter head probe GS5• Dust collector LC oder• Dust collector HC• Operation Via LC-Display and Function key pad; Version SHC502 with operational software• ApprovalsCompliances EN 13284-1• US-EPA Method 17•
Most popular related searches
