Amiblu Holding GmbH
- Home
- Companies & Suppliers
- Amiblu Holding GmbH
- Downloads
- Hobas - Jacking Pipes - Data Sheets
Hobas - Jacking Pipes - Data Sheets
de [mm] SN SN SN SN SN SN SN SN SN SN SN SNCoupling 32000 40000 50000 64000 80000 100000 128000 160000 200000 320000 640000 1000000272 e [mm] 19 24m [kg/m] 33 41stainless steel F [kN]* 204 297324 e [mm] 20 23 28m [kg/m] 42 48 57stainless steel F [kN]* 273 341 452376 e [mm] 19 20 23 27 32m [kg/m] 47 49 56 65 76stainless steel F [kN]* 297 324 405 424 638401 e [mm] 19 20 21 24 28 34 39m [kg/m] 50 53 55 62 72 86 97stainless steel F [kN]* 315 344 373 459 572 736 868GRP F [kN]* 647 779427 e [mm] 19 20 21 24 28 34 43m [kg/m] 54 56 59 67 77 92 114stainless steel F [kN]* 342 373 405 497 618 795 1049GRP F [kN]* 696 950478 e [mm] 21 23 25 27 29 33 41 46m [kg/m] 66 72 78 84 90 101 124 137stainless steel F [kN]* 449 519 588 657 725 859 1120 1278GRP F [kN]* 1015 1173501 e [mm] 20 22 24 26 28 30 35 43 48m [kg/m] 66 73 79 85 91 98 113 136 150stainless steel F [kN]* 434 509 582 655 727 798 974 1247 1412GRP F [kN]* 864 1137 1302* The allowable jacking force (kN) corresponds to a safety factor of 3.5 times the ultimate force calculated. Project-relatedstatic calculations can result in differing allowable jacking forces.Wall thicknesses and pipe masses are minimum values or guidelines (plus tolerances).Jacking Pipes de 272 - 501Jacking pipes with flush coupling (GRP or stainless steel), including allowable jacking forces. The standard length of the pipeis 6 m. Lengths of 1 / 2 / 3 m are available on request.Pipes supplied with injection nozzles in coordination with the responsible HOBAS Application Engineering Department.A05GRAVITYPIPESAll values derive from calculations and may therefore slightly vary from the finished product due to manufacturing tolerances. The information and recommendations reflect the state of knowledge atthe time of publication and cannot be construed as an express or implied warranty. All information has to be checked and if necessary agreed upon in each individual case. HOBAS does not acceptany liability. This also applies to errors, omissions and changes to technical data without notice.12de [mm] SN SN SN SN SN SN SN SN SN SN SN SNCoupling 32000 40000 50000 64000 80000 100000 128000 160000 200000 320000 640000 1000000530 e [mm] 20 23 24 26 28 31 36 44 51m [kg/m] 70 81 84 90 97 107 123 148 169stainless steel F [kN]* 459 577 616 694 770 885 1071 1362 1608GRP F [kN]* 957 1247 1492550 e [mm] 20 21 22 24 26 28 30 33 38 47 53m [kg/m] 73 75 80 87 94 101 108 118 134 163 182stainless steel F [kN]* 484 505 566 648 728 808 888 1006 1199 1537 1755GRP F [kN]* 893 1086 1423 1640616 e [mm] 21 23 25 27 29 32 34 37 43 50 58m [kg/m] 86 94 102 110 118 129 137 148 170 196 224stainless steel F [kN]* 583 675 767 858 949 1083 1172 1304 1564 1860 2188GRP F [kN]* 1040 1172 1432 1727 2055650 e [mm] 21 24 25 26 28 30 33 35 38 44 54 62m [kg/m] 91 104 108 112 120 128 141 149 161 184 222 252stainless steel F [kN]* 613 760 809 857 953 1049 1191 1285 1425 1700 2146 2491GRP F [kN]* 1055 1148 1288 1563 2008 2352718 e [mm] 23 25 27 28 30 32 35 40 43 48 59 68m [kg/m] 110 120 129 134 143 152 165 187 201 222 269 305stainless steel F [kN]* 733 842 949 1003 1109 1215 1373 1633 1787 2040 2583 3012GRP F [kN]* 1121 1278 1538 1691 1944 2486 2915752 e [mm] 24 26 28 30 33 36 39 42 45 51 62 72m [kg/m] 121 130 140 150 164 178 192 206 220 247 296 338stainless steel F [kN]* 800 913 1026 1138 1305 1470 1634 1797 1958 2276 2843 3342GRP F [kN]* 1231 1396 1560 1722 1882 2199 2765 3263* The allowable jacking force (kN) corresponds to a safety factor of 3.5 times the ultimate force calculated. Project-relatedstatic calculations can result in differing allowable jacking forces.Wall thicknesses and pipe masses are minimum values or guidelines (plus tolerances).Jacking Pipes de 530 - 752Pipes supplied with injection nozzles in coordination with the responsible HOBAS Application Engineering Department.Jacking pipes with flush coupling (GRP or stainless steel), including allowable jacking forces. The standard length of the pipeis 6 m. Lengths of 1 / 2 / 3 m are available on request.A05GRAVITYPIPESAll values derive from calculations and may therefore slightly vary from the finished product due to manufacturing tolerances. The information and recommendations reflect the state of knowledge atthe time of publication and cannot be construed as an express or implied warranty. All information has to be checked and if necessary agreed upon in each individual case. HOBAS does not acceptany liability. This also applies to errors, omissions and changes to technical data without notice.13de [mm] SN SN SN SN SN SN SN SN SN SN SN SNCoupling 32000 40000 50000 64000 80000 100000 128000 160000 200000 320000 640000 1000000820 e [mm] 25 27 29 33 35 38 42 45 49 54 67 78m [kg/m] 137 148 158 179 190 205 226 241 261 286 349 400stainless steel F [kN]* 964 1088 1211 1456 1578 1758 1998 2175 2410 2699 3433 4033GRP F [kN]* 1229 1351 1531 1770 1947 2181 2471 3203 3802860 e [mm] 27 29 31 35 37 40 43 47 51 58 72m [kg/m] 155 166 178 199 210 227 243 264 285 321 392stainless steel F [kN]* 1140 1270 1399 1655 1783 1972 2160 2409 2655 3080 3905GRP F [kN]* 1407 1534 1724 1911 2160 2406 2830 3654924 e [mm] 29 32 34 37 40 42 46 50 54 62 77m [kg/m] 179 197 209 227 244 256 279 302 324 369 450stainless steel F [kN]* 1302 1511 1649 1856 2061 2197 2466 2734 2998 3520 4470GRP F [kN]* 1448 1654 1859 1995 2264 2531 2796 3316 4265960 e [mm] 31 34 36 39 42 44 48 52 56 64 80m [kg/m] 199 217 230 244 266 278 302 326 350 396 486stainless steel F [kN]* 1497 1714 1857 2072 2284 2425 2706 2983 3258 3801 4854GRP F [kN]* 1478 1621 1836 2048 2189 2469 2746 3021 3563 46151026 e [mm] 34 36 38 41 44 48 52 56 61 68m [kg/m] 233 246 259 279 298 324 350 375 407 450stainless steel F [kN]* 1830 1984 2138 2367 2595 2897 3196 3492 3859 4366GRP F [kN]* 1585 1739 1893 2122 2350 2651 2950 3246 3612 41181099 e [mm] 35 38 41 44 48 51 56 59 64 73m [kg/m] 257 278 300 321 348 369 403 424 457 517stainless steel F [kN]* 2040 2288 2535 2781 3106 3348 3748 3987 4380 5079GRP F [kN]* 1717 1965 2212 2457 2781 3023 3423 3661 4054 4752* The allowable jacking force (kN) corresponds to a safety factor of 3.5 times the ultimate force calculated. Project-relatedstatic calculations can result in differing allowable jacking forces.Wall thicknesses and pipe masses are minimum values or guidelines (plus tolerances).Jacking Pipes de 820 - 1099Pipes supplied with injection nozzles in coordination with the responsible HOBAS Application Engineering Department.Jacking pipes with flush coupling (GRP or stainless steel), including allowable jacking forces. The standard length of the pipeis 6 m. Lengths of 1 / 2 / 3 m are available on request.A05GRAVITYPIPESAll values derive from calculations and may therefore slightly vary from the finished product due to manufacturing tolerances. The information and recommendations reflect the state of knowledge atthe time of publication and cannot be construed as an express or implied warranty. All information has to be checked and if necessary agreed upon in each individual case. HOBAS does not acceptany liability. This also applies to errors, omissions and changes to technical data without notice.14de [mm] SN SN SN SN SN SN SN SN SN SN SN SNCoupling 32000 40000 50000 64000 80000 100000 128000 160000 200000 320000 640000 10000001229 e [mm] 40 43 46 49 53 56 61 66 71 81m [kg/m] 328 352 376 399 430 454 492 530 568 642stainless steel F [kN]* 2748 3026 3302 3576 3940 4212 4660 5105 5546 6415GRP F [kN]* 2289 2566 2842 3116 3479 3750 4198 4643 5083 59511280 e [mm] 41 45 47 52 55 59 64 68m [kg/m] 351 384 400 441 465 497 537 569stainless steel F [kN]* 2968 3353 3545 4022 4306 4682 5149 5520GRP F [kN]* 2434 2819 3011 3487 3770 4146 4612 49831348 e [mm] 44 47 50 54 58 62 67 72m [kg/m] 396 422 448 483 517 551 593 635stainless steel F [kN]* 3467 3771 4074 4476 4875 5272 5764 6252GRP F [kN]* 2825 3129 3432 3833 4232 4628 5120 56081434 e [mm] 46 49 52 57 61 65 71 76m [kg/m] 441 469 496 542 578 615 668 713stainless steel F [kN]* 3890 4215 4537 5072 5497 5919 6548 7067GRP F [kN]* 3150 3474 3796 4330 4755 5176 5804 63231499 e [mm] 48 52 56 60 64 68 74 79m [kg/m] 481 520 558 596 634 672 728 775stainless steel F [kN]* 4236 4688 5137 5583 6027 6469 7126 7669GRP F [kN]* 3476 3927 4376 4822 5265 5705 6361 69041535 e [mm] 49 53 57 62 66 70 76 81m [kg/m] 504 544 583 632 671 710 767 815stainless steel F [kN]* 3925 4389 4850 5423 5878 6331 7005 7562GRP F [kN]* 3664 4127 4587 5159 5614 6066 6739 7296* The allowable jacking force (kN) corresponds to a safety factor of 3.5 times the ultimate force calculated. Project-relatedstatic calculations can result in differing allowable jacking forces.Wall thicknesses and pipe masses are minimum values or guidelines (plus tolerances).Jacking Pipes de 1229 - 1535Pipes supplied with injection nozzles in coordination with the responsible HOBAS Application Engineering Department.Jacking pipes with flush coupling (GRP or stainless steel), including allowable jacking forces. The standard length of the pipeis 6 m. Lengths of 1 / 2 / 3 m are available on request.A05GRAVITYPIPESAll values derive from calculations and may therefore slightly vary from the finished product due to manufacturing tolerances. The information and recommendations reflect the state of knowledge atthe time of publication and cannot be construed as an express or implied warranty. All information has to be checked and if necessary agreed upon in each individual case. HOBAS does not acceptany liability. This also applies to errors, omissions and changes to technical data without notice.15de [mm] SN SN SN SN SN SN SN SN SN SN SN SNCoupling 32000 40000 50000 64000 80000 100000 128000 160000 200000 320000 640000 10000001638 e [mm] 52 56 60 65 70 75 81m [kg/m] 569 611 653 706 757 809 870stainless steel F [kN]* 4585 5079 5570 6180 6786 7388 8106GRP F [kN]* 4218 4711 5202 5811 6417 7018 77341720 e [mm] 55 59 64 68 73 78 84m [kg/m] 632 676 731 775 830 884 948stainless steel F [kN]* 5133 5651 6295 6807 7444 8077 8831GRP F [kN]* 4381 4899 5542 6054 6690 7322 80751842 e [mm] 59 63 68 73 78 83m [kg/m] 726 774 833 892 950 1008stainless steel F [kN]* 6074 6630 7320 8007 8689 9368GRP F [kN]* 5224 5779 6469 7154 7836 85131937 e [mm] 62 67 72 77 81 86m [kg/m] 803 866 928 990 1039 1100stainless steel F [kN]* 6824 7554 8281 9003 9578 10293GRP F [kN]* 5325 6055 6781 7503 8078 87932047 e [mm] 65 70 75 81 85m [kg/m] 889 955 1021 1099 1151stainless steel F [kN]* 7682 8453 9221 10136 10743GRP F [kN]* 6549 7319 8086 9000 96062160 e [mm] 69 74 79 85 90m [kg/m] 995 1065 1134 1217 1285stainless steel F [kN]* 8828 9641 10450 11416 12216GRP F [kN]* 7185 8003 8808 9773 10573* The allowable jacking force (kN) corresponds to a safety factor of 3.5 times the ultimate force calculated. Project-relatedstatic calculations can result in differing allowable jacking forces.Wall thicknesses and pipe masses are minimum values or guidelines (plus tolerances).Jacking Pipes de 1638 - 2160Jacking pipes with flush coupling (GRP or stainless steel), including allowable jacking forces. The standard length ofthe pipe is 6 m. Lengths of 1 / 2 / 3 m are available on request.Pipes supplied with injection nozzles in coordination with the responsible HOBAS Application Engineering Department.A05GRAVITYPIPESAll values derive from calculations and may therefore slightly vary from the finished product due to manufacturing tolerances. The information and recommendations reflect the state of knowledge atthe time of publication and cannot be construed as an express or implied warranty. All information has to be checked and if necessary agreed upon in each individual case. HOBAS does not acceptany liability. This also applies to errors, omissions and changes to technical data without notice.16de [mm] SN SN SN SN SN SN SN SN SN SN SN SNCoupling 32000 40000 50000 64000 80000 100000 128000 160000 200000 320000 640000 10000002250 e [mm] 71 76 82 87 94m [kg/m] 1068 1141 1227 1299 1399stainless steel F [kN]* 9512 10360 11373 12212 13381GRP F [kN]* 7987 8835 9846 10685 118522400 e [mm] 76 81 86 93 100m [kg/m] 1218 1295 1372 1480 1586GRP F [kN]* 9251 10154 11053 12304 135482453 e [mm] 80 82 88 95 102m [kg/m] 1312 1344 1438 1548 1657GRP F [kN]* 10127 10497 11602 12884 141572555 e [mm] 82 85 92 99 106m [kg/m] 1400 1450 1565 1679 1792GRP F [kN]* 10846 11423 12765 14099 154252999 e [mm] 94 100 108 117 127m [kg/m] 1887 2003 2157 2330 2520GRP F [kN]* 13068 14425 16226 18240 204623270 e [mm] 102 109 117 127m [kg/m] 2204 2357 2519 2712GRP F [kN]* 16054 17784 19751 219513600 e [mm] 112 120 128 139m [kg/m] 2700 2910 3090 3310GRP F [kN]* 20033 22478 24641 27598Jacking Pipes de 2250 - 3600Jacking pipes with flush coupling (GRP or stainless steel), including allowable jacking forces. The standard length ofthe pipe is 6 m. Lengths of 1 / 2 / 3 m are available on request.* The allowable jacking force (kN) corresponds to a safety factor of 3.5 times the ultimate force calculated. Project-relatedstatic calculations can result in differing allowable jacking forces.Wall thicknesses and pipe masses are minimum values or guidelines (plus tolerances).Pipes supplied with injection nozzles in coordination with the responsible HOBAS Application Engineering Department.A05GRAVITYPIPESAll values derive from calculations and may therefore slightly vary from the finished product due to manufacturing tolerances. The information and recommendations reflect the state of knowledge atthe time of publication and cannot be construed as an express or implied warranty. All information has to be checked and if necessary agreed upon in each individual case. HOBAS does not acceptany liability. This also applies to errors, omissions and changes to technical data without notice.17
