Anderson Instrument Co. LLC
HTST - Model AV-9900 - Recorder Controller- Brochure
The AV-9900 HTST recorder controller is specifically designed for use in continuous pasteurization applications. The unit combines failsafe protection for the pasteurization process with the broadest range of configuration options ever available in an HTST control package. This is accomplished via a unique, four color printing technology which prints on plain paper, 12", 100 division charts. Each unit is programmable for up to 4 independent recording ranges and input types. Each scale is color coded to its' trend pen to provide a chart that is simple to read, even with multiple variables.AV-9900 HTST Recorder ControllerThe standard unit provides legal Safety Thermal Limit Recorder (STLR) functionality with up to 5 selectable diversion setpoints. Remote selection of these setpoints is available as an option. Product temperature is monitored via our time proven dual element, 1,000 ohm RTD sensor. The STLR monitors sensor balance between the two elements to insure failsafe operation. The hot product scale, temperature, and flow diversion valve frequency trend are printed in red. When configured for multiple divert, the activated setpoint temperature is continuously printed in green.The unit can be optionally specified to include hot water control (HWC). This variable is normally displayed and controlled, but not recorded. For multiple divert applications, separate hot water setpoints can be programmed to be selected automatically when the diversion setpoint is changed.Cold product can be optionally specified for Recording (CPR), or Recording/Controlling (CPRC). The range for this function is programmable to • New four color recording technology prints all trends, scales, events and customer specific messages on a plain paper, 12" chart.• Hot product, cold product, hot water, and flow-rate all recorded and/or controlled in a single unit.• Meets all PMO requirements for HTST, HHST, and UHT applications.provide maximum readability in the product range while including CIP temperature. The standard color for this variable is blue.Now available with a Safety Flow Limit function for systems with meter based timing. This option can include Recording (SFLR) or Recording and Control (SFLRC). Range can be configured in percent flow or engineering units (GPM etc.). The standard color for this function is black.F L O WL E V E LP R E S S U R EA N A L Y T I C A LT E M P E R A T U R EI N S T R U M E N T A T I O N P A S T E U R I Z A T I O N C O N T R O L SFAMILYSTLR HOT WATER CONTROL0 None2 PID - Onboard PID Controller * COLD PRODUCT0 None 1 Recorder2 Recorder with Controller *FLOW RATE** 0 None2 Safety Flow Limit - Record Only††3 Safety Flow Limit - Record & Control *††RELAYS (Other Than STLR Relay)0 None 2 Two 4 Four SETPOINT SELECTION†0 None (five internally selected setpoints)1 Two (2) remotely selected setpoints2 Four (4) remotely selected setpoints4-20 mA OUTPUTS0 None 1 One (internally powered) 2 Two (internally powered)3 Three (internally powered)4 Four (internally powered)5 Two (externally powered)6 Four (externally powered)7 Four (2-int. pwr., 2-ext. pwr.)PRODUCT CODECASE MOUNT3 Wall/PanelFIXED CHARACTER VOLTAGE 1 1102 220FIXED CHARACTER TRANS. POWER SUPPLIES 0 None1 One2 Two3 Three AV- 9 A AV-9900 Recording Controller SpecificationsPERFORMANCERecording Accuracy:±0.3% of chart span reference accuracyOperating Temperature:0 to 50°C (32 to 122°F)Humidity:10 to 90% RH, non-condensingWarranty:2 yearsAgency Approvals:UL approved in the USA, UL certified for CanadaINPUTSSTLR Input:Dual Element, 1,000 ohm, 3-wireHot Water & Cold Product:Single Element, 100 ohm, 3-wire or 4-20mA, 2-wireFlow Rate:4-20mA, 2-wireOUTPUTSA total of four on/off relay outputs and up to four 4 to 20mA analog outputs are available.STLR Relay:DPDT, 5 amps at 115 VAC, 2.5 amps at 230 VACRelay Outputs:SPDT, contacts rated 5 amps resistive at 115 VAC, 2.5 amps resistive at 230 VAC.POWERAC Power:115 or 230 VAC, ±15%, 50/60 Hz, auto-switching.PHYSICALOverall Dimensions:14.12 inches wide x 17.04 inches high x 7.75 inches deep : (358.65mm wide x 425.96mm high x 196.85mm deep)Panel Depth:5.25 inches (133.35mm)Panel Cutout:12.7 inches wide x 12.7 inches high (322.58mm X 322.58mm)Front Panel Protrusion:2.5 inches (63.5mm)Weight:25 lbs. maximum (55 kg)Vibration:3 to 100 Hz @ 0.2gEnclosure:Gasketed cover, case and windows. Structural foam case, cover material with plastic window areas, NEMA 4X.Mounting:Universal, Panel or wall.Chart:12" diameter, 100 linear divisionsDISPLAY AND KEYPADPrimary Display:2 line, 40 character vacuum fluorescent display with characters .21 inches (5 mm) high.MATRIXCharts: Order #002154013 0 ** Consult factory for compliance status.Note: Request worksheet 1029 for additional information required prior to order acceptance.† If option (1) or (2) is selected, local setpoint select is disabled.†† This option requires at least 2 relays, High and Low flow cutout.ANDERSON INSTRUMENT CO., INC • 156 AURIESVILLE RD. • FULTONVILLE, NY 12072 • USA • 800-833-0081 • FAX 518-922-8997ANDERSON INSTRUMENT CO. LP • 400 BRITANNIA RD. EAST, UNIT 1 • MISSISSAUGA, ONTARIO L4Z 1X9 • CANADA • 905-603-4358 • FAX 905-568-1652NEGELE MESSTECHNIK GmbH • RAIFFEISENWEG 7 • D-87743 EGG A. D. GüNZ • GERMANY • +49 (0) 8333/9204-0 • FAX +49 (0) 8333/9204-49www.andinst.com FORM AIC5002 Revised: November 2012Supersedes: August 20079 3 H * Must specify one mA output for each of the following additional functions specified. Hot Water Control - Option 2 Cold Product - Option 2 Flow Rate - Option 3 FITTING 004 1-1/2” Tri-Clamp 005 2” Tri-Clamp 006 2-1/2” Tri-Clamp 007 3” Tri-Clamp 008 4" Tri-Clamp 061 Split Ferrule (button) 119 3/4” Swagelok 1 HOUSING 1 Straight2 Bent (for clearance 22-1/2° - split ferrule only)SB- CABLE LENGTH00 No Cable 05 125’ 01 25’ 06 150’ 02 50’ 07 175’ 03 75’ 08 200’ 04 100’ PROBE LENGTH 025 2” (std. for 119 fitting)081 5-1/2” (standard)109 7-1/4”Sensor1 Not 3-A compliant
Most popular related searches
