Southern Scientific Ltd. - a LabLogic Company

identiFINDER 2 Datasheet

NEW THREATS. NEW THINKING.® PR O D U C T O V ER V IE W FEATURES • TFT LCD 64k color display • LED stabilized • 12 channel, Sirf III GPS • Reachback via Bluetooth© connected to DUN capable cell phone • ANSI N42.42 output format • Web interface for monitoring and configuring instrument • Original three button operation • 1 GB event data storage • Visible, audible and tactile alarm annunciators • Embedded Windows CE operating system • Meets ANSI N42.34 shock conditions NEXT GENERATION HANDHELD RADIONUCLIDE IDENTIFICATION DEVICE identiFINDER® 2 The identiFINDER® 2 is a logical enhancement of the original identiFINDER series of handheld instruments for the detection and identification of radionuclides. The owners and operators of the 10,000+ identiFINDERs currently deployed worldwide have provided ICx with a tremendous resource for suggestions and comments on how to improve the already exceptional identiFINDER. The identiFINDER 2 is the result of these comments and suggestions. The monochrome LCD display has been replaced with a TFT LCD, 64k color, 320 by 240 pixel display that is readable in virtually all light conditions. The spectrum is continuously source peak or LED peak stabilized to handle a wide range of count rates and conditions. The advantage of the LED stabilization technique is that there is no peak interference in the identification spectrum. Wired communication uses a micro USB connector, USB 2.0, and wireless communication is via a Class 2.0 Bluetooth© interface, with a 33 ft (10m) range. Both communication methods support the reach-back capability provided with the identiFINDER 2. A Web interface is provided via USB emulated TCPIP (LAN) for monitoring and configuring the identiFINDER 2. A twelve channel, Sirf III GPS is included for incident location. Data storage has been enlarged to 1 GB to save more spectra and event information. Features of the original identiFINDER that are unchanged are the size, shape and weight; the three button (fourth for power) operation; the scintillation, neutron and GM detector types, sizes and sensitivities; the screens and menus, when operated in the original identiFINDER mode; the types of alarms; the radionuclide identification accuracy; and the reliability, support and service. Annunciators and Displays All components clearly marked: 1 12 channel GPS, SIRF III antennae 2 Display: Alarm visualization 3 Red LED (doserate alarm) 4 Blue LED (neutron alarm) 5 Tacticle alarm vibrator (inside housing) 6 powerPACK Ultra (inside removable base) MEASURING FINDING ANALYZING IDENTIFYING identiFINDER® 2 Series 1 2 3 4 5 6 1 Green LED (external power) 2 Orange LED (charging) 3 Audible alarm speaker (inside housing) 4 USB 2.0, micro-B connector 5 Bluetooth© (inside housing) identiFINDER® 2-ULCS-NG • Internal 3 nCi Cs137 source included for start-up energy calibration verification • LED peak stabilized with NaI gamma detector • GM detector for high doserate situations identiFINDER® 2-ULCS-NGH • Internal 3 nCi Cs137 source included for start-up energy calibration verification • LED peak stabilized with NaI gamma detector • GM detector for high doserate situations • Moderated He3 neutron detector identiFINDER® 2-NG • Internal 15 nCi CS137 source included for start-up energy calibration verification • Spectral stabilization with NaI gamma detector • GM detector for high doserate situations identiFINDER® 2-ULK-NG • External K40 (250 ± 10 grams of KCl) included for start-up energy calibration verification • LED peak stabilized with NaI gamma detector • GM detector for high doserate situations identiFINDER® 2-NGH • Internal 15 nCi CS137 source included for start-up energy calibration verification • Spectral stabilization with NaI gamma detector • GM detector for high doserate situations • Moderated He3 neutron detector identiFINDER® 2-ULK-NGH • External K40 (250 ± 10 grams of KCl) included for start-up energy calibration verification • LED peak stabilized with NaI gamma detector • GM detector for high doserate situations • Moderated He3 neutron detector Six Available Models DETECTOR TYPES Gamma NaI, 1.4 in x 2 in (35 mm x 51 mm) High Dose Gamma GM detector Neutron Moderated He3 proportional detector 0.6 in x 2.1 in (15 mm x 54 mm) @ 8 atm PERFORMANCE Gamma Energy Range 20 keV to 3 MeV Gamma Resolution = 8% @ 662 keV (typically) Gamma Sensitivity > 900 cps/µSv/h (>9 cps/µR/h) for Cs137, 662 keV Doserate Range 0.01 µSv/h to 1 Sv/h (1 µR/h to 100 R/h) Dose Range 0.01 µSv to 1 Sv (1 µR to 100 R) Neutron Sensitivity 2.6 CPS/nv ± 20% Stabilization Cs137 source peak or LED peak; ± 1% for temperature change rate of <0.5°C/min Nuclide Identification Per ANSI N42.34 OPERATING CONDITIONS Temperature -4°F to +131°F (-20°C to +55°C) Humidity 10% to 80%, non-condensing Shock According to ANSI N42.34 Protection Rating IP53 according to IEC 60529 INPUTS / OUTPUTS DC Power / Charger + 9V DC / 2A Bluetooth© Class 2.0, max range 33 ft (10 m) Activated on demand USB USB 2.0, micro-B connector GPS Built-in, 12 channel SIRF III receiver Web Interface Via USB emulated TCPIP (LAN) Data Format ANSI N42.42 2006; standard for DHS PHYSICAL Size 9.75 in x 3.67 in x 2.95 in (248 mm x 93 mm x 75 mm) Weight 2.65 lbs (1.2 kg) with neutron detector 2.6 lbs (1.18 kg) w/o neutron detector Display TFT, True Color LCD, 64k colors Display Size 2.7 in (68.4 mm) diagonal, 320 * 240 pixel R A _I D EN TI FI N D ER 2_ 10 25 10 SPECIFICATIONS The Americas 2100 Crystal Drive Suite 650 Arlington, VA 22202 T +1. 877.692.2120 sales@icxt.com Middle East Suite 1-11 Building 6E-A Dubai Airport Freezone PO Box 371363 Dubai, UAE T +971 4 701 7195 F +971 4 701 7194 mesales@icxt.com Europe Piepersberg 12 42653 Solingen Germany T +49 212 222090 F +49 212 201045 europesales@icxt.com Asia Level 28 Gateway East 152 Beach Road Singapore T +65.6827.9789 F +65.6295.2567 asiasales@icxt.com POWER Power Operating Time Charging Time MEMORY Memory Data Storage Capacity Data Logging Screen Shots Alarms SOFTWARE Embedded Software Web Interface Reachback Stride Data Protocol One powerPACK Ultra with 4 ea NiMH AA @ 2200 mAh @ 1.2 V, One powerPACK 2 > 8 hours, full charge (doserate mode) 4 hours, full charge (fast charge) 1.8 GB 600,000 radionuclide identifications including spectrum Every 5 secs for 5 years w/o neutron data Every 5 secs for 2.5 years w/ neutron data = 2,500 = 2,500 Windows CE operating system TCP/IP emulated via USB ANSI N42.42 data via Bluetooth© to DUN compatible cell phone Stride Data Protocol for network integration
Most popular related searches