Insulation Resistance Meters MIC-10k1- Brochure

OPERATING MANUAL INSULATION RESISTANCE METERS MIC-10k1 and MIC-5050 SONEL SA ul. Wokulskiego 11 58-100 Swidnica, Poland Version 1.03 29.08.2014 OPERATING MANUAL MIC-10k1 version 1.03 2 MIC-10k1 and MIC-5050 meters are modern, high-quality meters, easy and safe in operation. Please acquaint yourself with this manual in order to avoid measuring errors and prevent possible problems in operation of the meter. OPERATING MANUAL MIC-10k1 version 1.03 3 CONTENTS 1 SAFETY .................................................................................................................... 5 2 MENU ........................................................................................................................ 6 2.1 WIRELESS TRANSMISSION ........................................................................................ 6 2.2 MEASUREMENT SETTINGS ....................................................................................... 7 2.2.1 Mains frequency ............................................................................................ 7 2.2.2 Times t1, t2, t3 for calculating absorption coefficients .................................. 8 2.2.3 Type of absorption coefficients ...................................................................... 8 2.2.4 IISO test current............................................................................................... 8 2.2.5 Setting limit values ......................................................................................... 9 2.2.6 Temperature unit ........................................................................................... 9 2.2.7 Auto-incrementing of the memory cell number ............................................ 10 2.2.8 Filter ............................................................................................................ 10 2.2.9 Chart type selection ..................................................................................... 10 2.3 METER SETTINGS ................................................................................................. 11 2.3.1 LCD contrast ............................................................................................... 12 2.3.2 Automatic shut-off (Auto-OFF) ................................................................... 12 2.3.3 Date and time ............................................................................................... 12 2.3.4 Factory (default) settings ............................................................................. 13 2.3.5 Software update ........................................................................................... 13 2.3.6 Key sounds ................................................................................................... 14 2.3.7 Wireless communication .............................................................................. 14 2.4 LANGUAGE CHOICE .............................................................................................. 14 2.5 INFORMATION ABOUT MANUFACTURER ................................................................. 15 3 MEASUREMENTS ................................................................................................ 16 3.1 DIAGNOSTICS PERFORMED BY THE METER - LIMITS ................................................ 16 3.2 MEASUREMENT OF INSULATION RESISTANCE ......................................................... 16 3.2.1 Double-lead measurement ........................................................................... 17 3.2.2 Three-lead measurement ............................................................................. 22 3.2.3 Measurements with AutoISO-5000 .............................................................. 23 3.2.4 Measurements with increasing voltage - SV ................................................ 26 3.2.5 Dielectric Discharge Indicator - DD ........................................................... 28 3.2.6 Damage location (after-burning) ................................................................. 30 3.3 LOW-VOLTAGE MEASUREMENT OF RESISTANCE ...................................................... 32 3.3.1 Measurement of resistance of protective conductors and equipotential bonding with ±200 mA current .................................................................... 32 3.3.2 Calibration of test leads ............................................................................... 33 3.4 TEMPERATURE MEASUREMENT ............................................................................. 34 4 MEMORY OF MEASUREMENT RESULTS .................................................... 35 4.1 STRUCTURE OF THE MEMORY ............................................................................... 35 OPERATING MANUAL MIC-10k1 version 1.03 4 4.1.1 The appearance of main windows in the measurement recording mode ..... 35 4.2 STORING THE MEASUREMENT RESULTS IN THE MEMORY ......................................... 37 4.2.1 Entering the results without extending the memory structure ..................... 37 4.2.2 Extending the memory structure .................................................................. 39 4.3 VIEWING MEMORY DATA ....................................................................................... 44 4.4 DELETING MEMORY DATA ..................................................................................... 46 5 DATA TRANSMISSION ....................................................................................... 47 5.1 SET OF ACCESSORIES TO CONNECT THE METER TO A PC ........................................ 47 5.2 DATA TRANSMISSION THROUGH USB PORT ............................................................ 47 5.3 CONNECTING TO BLUETOOTH MINI-KEYBOARD. .................................................... 48 5.3.1 Manual connection ...................................................................................... 48 5.3.2 Automatic connection .................................................................................. 50 5.4 DATA TRANSMISSION USING BLUETOOTH MODULE ................................................. 50 5.5 READ-OUT AND CHANGE OF PIN CODE FOR BLUETOOTH CONNECTIONS ................ 51 6 POWER SUPPLY OF THE METER ................................................................... 52 6.1 MONITORING THE POWER SUPPLY VOLTAGE .......................................................... 52 6.2 BATTERY POWER .................................................................................................. 52 6.3 CHARGING RECHARGEABLE BATTERY .................................................................... 52 6.4 POWER SUPPLY FROM MAINS ................................................................................ 53 6.5 GENERAL PRINCIPLES FOR GEL USING (LEAD) RECHARGEABLE BATTERIES .............. 53 7 CLEANING AND MAINTENANCE ................................................................... 54 8 STORAGE .............................................................................................................. 54 9 DISMANTLING AND UTILISATION ................................................................ 54 10 TECHNICAL SPECIFICATIONS ....................................................................... 55 10.1 BASIC DATA .......................................................................................................... 55 10.2 ADDITIONAL DATA ................................................................................................ 57 10.2.1 Additional uncertainties according to EN 61557-2 (RISO) ........................... 58 10.2.2 Additional uncertainties according to EN 61557-4 (RCONT) ........................ 58 11 EQUIPMENT ......................................................................................................... 58 11.1 STANDARD EQUIPMENT ........................................................................................ 58 11.2 OPTIONAL ACCESSORIES ....................................................................................... 58 12 MANUFACTURER ............................................................................................... 60 OPERATING MANUAL MIC-10k1 version 1.03 5 1 Safety MIC-10k1 and MIC-5050 meters are designed for performing check tests of protection against electric shock in mains systems. The meters are used for making measurements and providing results to determine safety of electrical installations. Therefore, in order to provide conditions for correct oper-ation and accuracy of obtained results, the following recommendations must be observed: ? Before you proceed to operate the meter, acquaint yourself thoroughly with the present manual and observe the safety regulations and specifications provided by the producer. ? Any application that differs from those specified in the present manual may result in a damage to the device and constitute a source of danger for the user. ? MIC-10k1 and MIC-5050 meters must be operated only by appropriately qualified personnel with relevant certificates authorising the personnel to perform works on electric systems. Operating the meter by unauthorised personnel may result in damage to the device and constitute a source of danger for the user. ? During measurements of insulation resistance, dangerous voltage up to 10 kV (MIC-10k1) or 5 kV (MIC-5050) occurs at the ends of test leads of the meter. ? Before the measurement of insulation resistance you must be sure that tested object is discon-nected from the power supply. ? During the measurement of insulation resistance do not disconnect test leads from the tested ob-ject before the measurement is completed (see par. 0); otherwise the capacitance of the object will not be discharged, creating the risk of electric shock. ? Using this manual does not exclude the need to comply with occupational health and safety regu-lations and with other relevant fire regulations required during the performance of a particular type of work. Before starting the work with the device in special environments, e.g. potentially fire-risk/explosive environment, it is necessary to consult it with the person responsible for health and safety. ? It is unacceptable to operate: ? a damaged meter which is completely or partially out of order, ? a meter with damaged insulation, ? a meter stored for an excessive period of time in disadvantageous conditions (e.g. excessive humidity). If the meter has been transferred from a cool to a warm environment with a high level of relative humidity, do not start measurements until the meter is warmed up to the ambi-ent temperature (approximately 30 minutes). ? Remember that BAT message appearing on the display indicates insufficient voltage of power supply and the need to recharge the batteries. ? Before measurement, choose a correct measurement function and make sure that test leads are connected to respective measuring terminals. ? Do not power the meter from sources other than those listed in this manual. ? RISO meter inputs are electronically protected against overloads (caused by e.g. connecting the meter to a live circuit) up to 825 V for 60 seconds. ? Repairs may be performed only by an authorised service point. Note: Due to continuous development of the meter’s software, the actual appearance of the dis-play, in case of some of the functions, may slightly differ from the display presented in this operating manual. ATTENTION To display the correct battery discharge status, it is necessary to completely discharge and then fully charge the battery, before starting the regular use of the meter. OPERATING MANUAL MIC-10k1 version 1.03 6 Note: An attempt to install drivers in 64-bit Windows 8 may result in displaying "Installation failed" message. Cause: Windows 8 by default blocks drivers without a digital signature. Solution: Disable the driver signature enforcement in Windows. 2 Menu Press MENU button. The main menu contains the following items: ? Wireless transmission ? Measurement Settings ? Meter Settings ? Language selection ? Information about manufacturer Use , and , buttons to select desired posi-tion. Enter a selected option by pressing ENTER. 2.1 Wireless transmission See sections 5.3 to 5.5. OPERATING MANUAL MIC-10k1 version 1.03 7 2.2 Measurement Settings The option of Measurement settings consists of: ? Mains frequency ? Times t1, t2, t3 for calculating absorption coefficients ? Absorption coefficients Ab1, Ab2 or DAR PI ? IISO test current ? Setting limit values ? Temperature unit ? Cell autoincrementing ? Filter - restricting RISO display ? Chart type selection Use , and , buttons to select desired posi-tion. Enter a selected option by pressing ENTER. 2.2.1 Mains frequency Only the measurement with a properly selected mains frequency will ensure optimum filtration of interferences. The meter is designed for filtration of interferences generated by 50 Hz and 60 Hz net-works. Use , to select the mains frequency. Confirm your choice by pressing ENTER but-ton. OPERATING MANUAL MIC-10k1 version 1.03 8 2.2.2 Times t1, t2, t3 for calculating absorption coefficients Use , buttons to scroll between times and press , buttons to set time values. Confirm your choice by pressing ENTER but-ton. Selection range: (1 s...600 s), t2 (1 s ... 600 s, but >t1), t3 (1 s...600 s, but >t2). 2.2.3 Type of absorption coefficients Use , buttons to select the type of coef-ficients: Ab or DAR PI. Confirm your choice by pressing ENTER button. 2.2.4 IISO test current OPERATING MANUAL MIC-10k1 version 1.03 9 Use , buttons to select the current val-ue. Confirm your choice by pressing ENTER button. 2.2.5 Setting limit values Use , buttons to switch on/off limit val-ues. Confirm your choice by pressing ENTER button. 2.2.6 Temperature unit Use , to select the temperature unit. Confirm your choice by pressing ENTER but-ton. OPERATING MANUAL MIC-10k1 version 1.03 10 2.2.7 Auto-incrementing of the memory cell number Use , to switch on/off the function of Auto-incrementing of the memory cell number. Confirm your choice by pressing ENTER but-ton. 2.2.8 Filter The meter is equipped with an advanced digital filter for result stabilisation in difficult and unsta-ble measurement conditions. The meter displays a filtered value of measurements for a specified time period, which may be 10 s, 30 s or 60 s. Use , to select a time period or to switch off the filter. Confirm your choice by pressing ENTER button. 2.2.9 Chart type selection To illustrate the measurement results on the chart, you may select current and resistance (R, I) or voltage and resistance (R, U). OPERATING MANUAL MIC-10k1 version 1.03 11 Use , buttons to select the values to be displayed on the chart. Confirm your choice by pressing ENTER button. 2.3 Meter Settings The option of Meter Settings consists of: ? LCD contrast ? Automatic shut-off ? Date and time ? Factory (default) settings ? Program update ? Button tones ? Wireless communication Use , and , buttons to select desired posi-tion. Enter a selected option by pressing ENTER. OPERATING MANUAL MIC-10k1 version 1.03 12 2.3.1 LCD contrast Select contrast value using , and , buttons; confirm your choice by pressing ENTER. 2.3.2 Automatic shut-off (Auto-OFF) The setting defines the shut-off time of idle meter. Use , buttons to set Auto-OFF time; confirm your choice by pressing ENTER. 2.3.3 Date and time OPERATING MANUAL MIC-10k1 version 1.03 13 Use , buttons to select the value to be changed (day, month, year, hour, minute). Set a required value using , buttons. When required settings are made, press ENTER . 2.3.4 Factory (default) settings In order to introduce factory (default) settings, highlight YES using , buttons and press ENTER . 2.3.5 Software update ATTENTION This function may be used only by the users who are fluent in operation of com-puter equipment. The guarantee does not cover defective operation of the device resulting from wrong use of this function. ATTENTION Before programming, charge the battery. During programming the meter must not be switched off as well as the transmis-sion cable must not be disconnected. Before updating software, download the firmware updating program from the manufacturer’s website (www.sonel.pl) and install it on your PC, then connect the meter to PC. Select Software upgrade in the MENU and follow the instructions displayed by the program. OPERATING MANUAL MIC-10k1 version 1.03 14 2.3.6 Key sounds Use , buttons to switch on/off key sounds. Confirm your choice by pressing ENTER button. 2.3.7 Wireless communication Use , buttons to switch on/off wireless communication. Confirm your choice by pressing ENTER button. 2.4 Language choice OPERATING MANUAL MIC-10k1 version 1.03 15 Use , buttons to select desired lan-guage and press ENTER. 2.5 Information about manufacturer OPERATING MANUAL MIC-10k1 version 1.03 16 3 Measurements Notes: The result of the latest measurement is remembered by the meter until the next measurement is started or the measuring function is changed by means of the rotary switch. The result of the latest measurement is displayed on the screen for 20 seconds. Then it may be recalled by pressing ENTER, also after the meter is turned off and turned back on again. WARNING: During a measurement, switching of the range switch is forbidden because it may damage the meter and pose a threat to the user. 3.1 Diagnostics performed by the meter - limits The meter is able to assess whether the measurement result is within acceptable limits. The us-er may set a limit, i.e. maximum or minimum value, which should not be exceeded by the result. For measurements of insulation resistance, the set limit is the minimum value, whereas for measurements of continuity of protective conductors and equipotential bonding- it is the maximum value. The limits are activated globally in the main menu (Section 2.1.5). When the function of setting limits is activated, the display, in its lower left corner, shows the symbols with the following meaning: - : the result is correct, it is within the set limits, - : the result is incorrect, it is outside the set limits, The method for setting limits is described in the chapters describing the measurement data. In DD, SV functions and in after-burning - it is not possible to set limits. 3.2 Measurement of insulation resistance WARNING: The tested object must not be live. Note: During measurement, especially of high resistances, make sure that test leads do not touch each other and probes (crocodile clips), because such a contact may cause the flow of sur-face currents resulting in additional error in measurement results. Inverter output current is limited at 1,2 mA, 3 mA or 5 mA level. Activation of the current limit is indicated by a continuous beep. The measurement result is correct, but on the test terminals the test voltage is lower than voltage selected before the measurement. The current limitation occurs in the first phase of the measurement due to charging the capacity of the tested object. OPERATING MANUAL MIC-10k1 version 1.03 17 The actual test voltage as a function of the measured insulation resistance RX (for maximum rated voltage) 3.2.1 Double-lead measurement Set the rotary switch of function selection at one of RISO positions, selecting simultaneously measuring voltage (for MIC-10k1 at 50...10000V voltage is adjusted as follows: 50 V...1 kV in 10V steps, 1 kV...10 kV in 25V steps; for MIC-5050 at 50...5000V voltage is adjusted as follows: 50 V...1 kV in 10V steps, 1 kV...5 kV in 25V steps). The meter is in the mode of measuring interference voltage of the tested object UN. OPERATING MANUAL MIC-10k1 version 1.03 18 To change the measuring voltage, press F1 . Use , buttons to set voltage value; confirm your choice by pressing ENTER. To set the measurement time, press F3 . To set the capacity of the tested object [nF/km] press F2 . Use , buttons to set capacity value; confirm your choice by pressing ENTER. The range of changes: from 10 nF to 990 nF. When setting --- (below 10 nF or above 990 nF) the function to calculate the length is switched off. In order to set the limit (minimum resistance), press F4 . OPERATING MANUAL MIC-10k1 version 1.03 19 Use , and ENTER buttons to enter the resistance value. Use , , , and ENTER buttons to select the unit. Confirm by pressing F5 . For RISO the limit is the minimum value. The range of setting the limit value is as follows: from 1 kO to 40 TO for MIC-10k1 or to 20 TO for MIC-5050. The meter is ready for measure-ment. Value of interference voltage can be read on the display. Connect test leads according to the drawing. OPERATING MANUAL MIC-10k1 version 1.03 20 Press and hold START button. The measurement is performed continuously until you release the button or the pre-set time is reached. In order to maintain (block) the measurement, press ENTER while holding START button pressed, then re-lease the buttons. In order to interrupt the measure-ment in this mode, press START again or press ESC. View of the screen during meas-urement. Press F4 to display a chart of the measured resistance and current as a function of time. When the graph is displayed, press F4 to re-turn to the tabular view of the results. OPERATING MANUAL MIC-10k1 version 1.03 21 After the measurement is completed, read the result. Result presented as a graph. Dashed horizontal line shows the value of set lim-it. Use , to move the cursor line (vertical dashed line) - the display will show data for the point the set RISO, IL and time. Note: During measurements of insulation resistance, dangerous voltage up to 10 kV (MIC-10k1) or 5 kV (MIC-5050) occurs at the ends of test leads of the meter. It is forbidden to disconnect test leads before the measurement is completed. Failure to obey the above instruction will lead to high voltage electric shock and make it impossible to discharge the tested object. - Disabling t2 will also disable t3. - Measuring time tn is independent of the t1, t2, t3 times set in MENU and overwrites them i.e. when tn < t3 then the measurement time will be equal to tn. - Timer measuring the measurement time is started when UISO voltage is stabilized. - LIMIT I message means operation with limited inverter power. If this condition persists for 20 sec-onds, the measurement is interrupted. - During the measurement yellow HV LED is lit. - After completion of measurement, the capacitance of the object tested is discharged by shorting RISO+ and RISO- terminals with resistance of 100 k? for MIC-5050 or 200 k? for MIC-10k1, simultane-ously the voltage of the tested object is displayed. - In case of power cables measure the insulation resistance between each conductor and other con-ductors shorted and grounded (figure below). - The length of the cable is calculated on the basis of its capacity on [km] written in before the meas-urement. OPERATING MANUAL MIC-10k1 version 1.03 22 Additional information displayed by the meter Test voltage is present on terminals of the meter. NOISE Interference voltage lower than 50 V DC or 500 V AC is present on the tested object. Measurement is possible but may be burdened with additional uncertainty. U>50V + two-tone beep The tested object is live. The measurement is blocked. LIMIT I Activation of current limit. The symbol displayed is accom-panied by a continuous beep. Current overflow Leakage current too high (breakdown of insulation during the measurement.) 3.2.2 Three-lead measurement In order to eliminate the influence of surface resistance in transformers, cables, etc. the three-lead measurement is used. For example: ? at the measurement of inter-winding resistance of a transformer, G socket of the meter should be connected to the transformer tank; OPERATING MANUAL MIC-10k1 version 1.03 23 ? when measuring insulation resistance between one of the cable conductors and the cable jack-et, the effect of surface resistances (important in difficult weather conditions) is eliminated by connecting a piece of metal foil insulating the tested conductor with G socket of the meter; The same shall apply when measuring the resistance between two conductors of the cable, at-taching to G terminal other conductors that do not take part in the measurement. 3.2.3 Measurements with AutoISO-5000 Connect AutoISO-5000 adapter. The meter detects this fact automatically and changes the appear-ance of the screen. Use F1 , F2 and F3 buttons to adjust de-sired test voltage, capacity of the object and measurement time, simi-larly as in section 3.2.2 Cable shield Cable sheath Metal foil wrapped around the conductor in-sulation Conductor OPERATING MANUAL MIC-10k1 version 1.03 24 Press F4 button to enter the selection of lead/ cable type (3-, 4- or 5-wire lead). Use , buttons to select an appropriate item and confirm it by ENTER. Use , buttons, to enter the second group of parameters. Press F4 to set the minimal resistance. It is the same for all conductor pairs of a cable. Use , and ENTER buttons to enter the resistance value. OPERATING MANUAL MIC-10k1 version 1.03 25 Use , , , and ENTER buttons to select the unit. Confirm by pressing F5 . The meter is ready for measure-ment. Value of interference voltage can be read on the display. Measurement Connect AutoISO-5000 adapter to the tested cable. Press START to start measurement. First, checking of voltages on particular pairs of wires is performed. If any of the voltages exceeds allowable voltage, symbol of this voltage is displayed with “” (e.g. UN-PE), and the measurement is in-terrupted. OPERATING MANUAL MIC-10k1 version 1.03 26 View of the screen during measurement. After the measurement is completed, read the re-sults. Use F1 and F2 buttons to change the group of displayed results. Note: - Remarks and messages are the same as in 3.2.3. 3.2.4 Measurements with increasing voltage - SV In this mode the meter performs a series of 5 measurements with increasing voltage; the voltage change depends on the set maximum voltage: - 1 kV: 200 V, 400 V, 600 V, 800 V and 1000 V, - 2.5 kV: 500 V, 1 kV, 1.5 kV, 2 kV and 2.5 kV, - 5 kV: 1 kV, 2 kV, 3 kV, 4 kV and 5 kV, - 10kV (for MIC-10k1): 2 kV, 4 kV, 6 kV, 8 kV, 10 kV. The end result for each of the 5 measurements is saved which is signalled by a beep and an appropriate icon. OPERATING MANUAL MIC-10k1 version 1.03 27 Set the rotary switch of function selection in the SV position. The meter is in the voltage measurement mode. Use F1 , F2 and F3 buttons to adjust de-sired test voltage, capacity of the object and measurement time, simi-larly as in section 3.2.2 Press and hold START button. The measurement is performed continuously as long as the button is held in pressed position or till the end of the measurement. In order to maintain (block) the measurement, press ENTER while holding START button pressed, then re-lease the buttons. In order to interrupt the measure-ment in this mode, press START again or press ESC. After the measurement is complet-ed, read the result. Use F4 , F5 buttons to switch between con-secutive measurements for a given sequence from 1 to 5. Press F1 to display a chart of the measured resistance and current as a function of time. Note: - Other comments and displayed symbols are the same as for standard RISO measurement. - In this function, it is also possible to perform the measurement with AutoISO-5000 adapter. The dis-play of results is similar to the measurement of RISO with AutoISO-5000. The screen will show the fol-lowing: OPERATING MANUAL MIC-10k1 version 1.03 28 3.2.5 Dielectric Discharge Indicator - DD In the dielectric discharge test the discharge current is measured after 60 seconds from the end of measurement (charging) of the insulation. The DD is a value characterising the insulation quality in-dependent from the test voltage. The measurement operates in the following way: first the insulation is charged with a current for a set period. If this voltage is not equal to the set voltage the object is not charged and the meter abandons the measurement procedure after 20 seconds. After the charging and polarisation is com-plete, the only current flowing through the insulation is the leakage current. Then the insulation is dis-charged and the total dielectric discharge current starts to flow through the insulation. Initially this cur-rent is the sum of the capacity discharge current, which fades quickly and the absorption current. The leakage current is negligible, because there is no test voltage. After 1 minute from closing the circuit the current is measured. The DD value is calculated using the formula: CUIDDpr ?? min1 where: I1min – current measured 1 minute after closing the circuit [nA], Upr – test voltage [V], C – capacitance [?F]. Set the rotary switch of function selection at DD. The meter is in the voltage measure-ment mode. OPERATING MANUAL MIC-10k1 version 1.03 29 Use F1 , F2 and F3 buttons to adjust de-sired test voltage, capacity of the object and measurement time (1 min ...60 min), similarly as in sec-tion 3.2.2 or Start the measurement, similarly as in sec-tion 3.2.4. Both during and after the measure-ment, the user may switch between the display of the results and the graph by pressing F4 . After the measurement is complet-ed, read the result. Press F4 to display a chart of the measured resistance and current as a function of time. The cursor (i.e. dashed vertical line) may be moved by using , buttons. Measured values are displayed for the point where the cursor is currently positioned. The measurement result indicates the sta-tus of the insulation, it may be compared with the following table: OPERATING MANUAL MIC-10k1 version 1.03 30 DD value Insulation condition >7 Bad 4-7 Weak 2-4 Not the best <2 OK Note: - in an environment with strong interferences the measurement may be affected by additional uncer-tainty. - In this function, it is also possible to perform the measurement with AutoISO-5000 adapter. The dis-play of results is similar to the measurement of RISO with AutoISO-5000. The screen will show the fol-lowing: 3.2.6 Damage location (after-burning) The meter carries out the measurement as for RISO, except that it is not interrupted at the break-down. In case of a breakdown, the measurement is continued, and the damage may be located as in-dicated by breakdown sound. Set the rotary switch of function selection at . The meter is in the voltage measure-ment mode. Use F1 , F2 and F3 buttons to adjust de-sired test voltage, capacity of the object and measurement time, simi-larly as in section 3.2.2 OPERATING MANUAL MIC-10k1 version 1.03 31 or Start the measurement, similarly as in sec-tion 3.2.2. View of the screen during meas-urement. Both during and after the measurement, the user may switch between the display of the results and the graph by pressing F4 . When the insulation breakdown occurs, the meter does not inter-rupt the measurement (as in other functions) and the display shows (at the top) the corresponding mnemonic. After the measurement is com-pleted, read the result. The display shown after the measurement with insulation breakdown. Press F4 to display a chart of the measured resistance and current as a function of time. OPERATING MANUAL MIC-10k1 version 1.03 32 3.3 Low-voltage measurement of resistance 3.3.1 Measurement of resistance of protective conductors and equipoten-tial bonding with ±200 mA current Set the rotary switch at the RCONT position. The meter is ready for meas-urement. Press F4 to set the maximum resistance. The setting limit reflects the function: from 0.01 O to 999 O. The value of the limit set in the same way as for RISO. Connect the meter to the tested object. Trigger the measure-ment by pressing the START button. OPERATING MANUAL MIC-10k1 version 1.03 33 Read out the result. Additional information displayed by the meter NOISE Interference voltage occurs on the tested object. The measurement is possible however it will be burdened with additional uncertainty that is specified in the tech-nical data. Voltage on object Un>10 V + two-tone, continuous beep + and LED lit in red Interference voltage exceeds the allowable value, the measurement is blocked. 3.3.2 Calibration of test leads In order to eliminate the impact of the resistance of test leads on measurement result, the com-pensation (autozeroing) of resistance may be performed. Press F1 . OPERATING MANUAL MIC-10k1 version 1.03 34 Follow the instructions displayed on the screen. Press START. AUTOZERO message appears, con-firming that the test leads' calibration has been performed, and the meter en-ters the measurement mode. AUTOZERO message remains visible during measurements. The compensation is active even after the meter is switched off and on again. In order to remove the calibration made (return to default calibration), perform the above-mentioned activities with test leads open. 3.4 Temperature Measurement Temperature Measurement commences after connecting the temperature probe and it is per-formed for each function. The display indicates the measurement by displaying the measured temper-ature. When the temperature is disconnected, the display shows "T=---". Values are refreshed every second. OPERATING MANUAL MIC-10k1 version 1.03 35 4 Memory of measurement results 4.1 Structure of the Memory The memory for test results has a tree-like structure (see figure below). The user has the ability to record data for ten clients. Each client may create max. 999 objects, which may store up to three levels of sub-objects, 999 sub-objects for each level. Each subject, and sub-object may store up to 999 measurements. The whole structure is limited by the size of memory. The memory allows for simultaneous re-cording of 10 full descriptions of customers, and a minimum of: measurement sets for 10000 measur-ing points and 10000 names of these points, 999 names for objects, 999 descriptions of sub-objects and remember the layout created for these objects. Additionally the memory has a space for the list of names (selection lists) extended up to 99 entries. 4.1.1 The appearance of main windows in the measurement recording mode The main folder window Bar with a client name / bar for menu location Free memory available: all internal lines visible - 100%, no internal line visible - 0% Bold borders indicate location of the cursor Hint bar Object icon Sub-object icon Bar for the name of object and sub-object and (when the cursor is on the client) client address (if entered) Connectors indicating the ability to move between the icons Marking of function buttons Object without any sub-object Successive number / total number of objects Object symbol Symbol of the measuring point and the number of such points (for this object) An object containing at least one sub-object Object symbol on a grey background Connector Sub-object without further sub-objects OPERATING MANUAL MIC-10k1 version 1.03 36 Successive number / total number of sub-objects in one level Sub-object symbol Symbol of the measuring point and the number of such points (for this sub-object) Sub-object containing more sub-objects Sub-object symbol on a grey back-ground Connector (appears when the cursor is over the icon.) Client edit window Active field Data fields Window for entering a name Information on the name entering mode Entry field On-screen keyboard To obtain larger fonts set the cursor on Shift and press ENTER. To obtain special (Polish) fonts set the cursor on ALT and press ENTER. OPERATING MANUAL MIC-10k1 version 1.03 37 Window for entering the measurement result Successive number / total number of saved cells Note: - Results of measurements performed for all measuring functions can be stored in one memory cell. - Only the results of the measurements started by pressing START key button can be stored in the memory (except autozeroing in low-voltage measurement of resistance). - Complete set of results (main result and supplementary results) for a given measuring function, pre-set measurement settings, date and time of the measurement are stored in the memory. - Cells unsaved are not available. - It is recommended to delete the memory after reading the data or before performing a new series of measurements that may be stored into the same memory cells as the previous ones. - A single cell may contain either a RISO 2(3)p measurement result, a RISO SV, or DD. - After entering the measurement result, the ID number of the cell is automatically increased. 4.2 Storing the measurement results in the memory Press ENTER after finishing the measurement. 4.2.1 Entering the results without extending the memory structure Press ENTER again. The cell is free for a given type of measurement. OPERATING MANUAL MIC-10k1 version 1.03 38 The cell is occupied for a given type of measurement. Use F4 , F5 buttons to scroll the components of the result. In order to select a measurement point (cell), use , . or press ENTER, to save the result in the memory or ESC, to return to displaying the memory structure. If you try to store data in an occupied memory cell, the following warning message will appear: or After selecting YES press ENTER to overwrite the re-sult or ESC, to cancel. Note: - Complete set of results (main result and supplementary results) for a given measuring function and preset measurement settings are stored in the memory. OPERATING MANUAL MIC-10k1 version 1.03 39 4.2.2 Extending the memory structure Press ESC to start creating the objects. Press button to set the cursor on Client 1. Use , buttons to select other clients (1 - 10). Press F1 to edit client data. OPERATING MANUAL MIC-10k1 version 1.03 40 Use , buttons to set the cursor on each item and press ENTER to start the editing. Use , and , buttons to select a character to be typed, and press ENTER to enter it. Press F4 to delete typed letters. Press F5 to confirm data and return to the screen of step . In this way, you may enter all client data. Press F5 to confirm data and return to the screen of step . Use button to set the cursor on the object icon. Press F1 to start edit-ing the object name. OPERATING MANUAL MIC-10k1 version 1.03 41 Enter the name of the object in the same way as for the customer data. You may use the list of proposed names that is available after pressing F1 . First the list should be created. After pressing F1 you may add further names to the list (up to 99 items), and pressing F2 deletes the items. Press F5 to approve the name that appears on the screen. Press ENTER, go to the measurement point. OPERATING MANUAL MIC-10k1 version 1.03 42 Press F1 to enter the editing of the measuring point name. Enter the name of the measuring point in the same way as the object name. press ENTER, to save the measurement result. After entering the memory, the user may extend its structure by adding new objects and sub-objects as needed. To add a new object, press F5 . OPERATING MANUAL MIC-10k1 version 1.03 43 To add a new sub-object, set the cursor on the chosen object and press F4 . Using F4 and F5 you may add new objects and sub-objects (up to 5 levels). Note: - New objects (sub-objects in a level) are added on the right side of the object marked with the cursor (sub-object). - The screen displays only sub-objects belonging to the object (sub-object) indicated by the cursor. - Deleting objects and sub-objects is possible only in memory browse mode. - The name of an object, sub-object or measurement is possible in memory browse mode or after en-tering entry into the memory after a measurement. OPERATING MANUAL MIC-10k1 version 1.03 44 4.3 Viewing memory data Set the rotary switch of function selection at MEM position. Use , buttons to select "MEMORY BROWSE AND EDIT”. Press ENTER button. Last saved measurement in sub-object 3, Level 1 Use , and , buttons to move between objects and sub-objects us-ing the existing connectors. Press F1 to enter the option for editing the name of object (sub-object) and change it. Press F2 to delete a chosen object (sub-object) with all its results. OPERATING MANUAL MIC-10k1 version 1.03 45 When the cursor is set on "Client", use , buttons to move to next clients. After selecting desired object (sub-object ) press ENTER. The number of measuring point / number of all measuring points. The number of measurement type / number of all measurements types at that point. Use , buttons to change the measurement point. Press F1 to enter the editing of the measuring point name and to change it. Press F4 or F5 to display all individual types of results for a given point. Press F2 to delete a chosen measurement or measuring point with all its results: OPERATING MANUAL MIC-10k1 version 1.03 46 4.4 Deleting memory data Set the rotary switch of function selection at MEM position. Use , buttons to select "MEMORY ERASING". Press ENTER button. Use , buttons to select YES or NO. Press ENTER button. OPERATING MANUAL MIC-10k1 version 1.03 47 5 Data transmission Note: - Data transmission is not possible while charging the battery. 5.1 Set of accessories to connect the meter to a PC In order to ensure the communication of the meter with a PC, a USB cable is required or Blue-tooth module and appropriate software supplied with the meter. The software may be used for many devices manufactured by SONEL S.A. which are equipped with the USB interface. Detailed information is available from the manufacturer and distributors. 5.2 Data transmission through USB port Set the rotary switch of function selection at MEM position. Use , buttons to select "TRANSFERING DATA TO EXTERNAL MEMORY". Press ENTER button. Connect the meter with PC or a USB flash drive using USB cable. Start the programme. OPERATING MANUAL MIC-10k1 version 1.03 48 5.3 Connecting to Bluetooth mini-keyboard. 5.3.1 Manual connection In order to connect to Bluetooth keyboard (paired keyboard), go to MENU ? Wireless transmis-sion ? Wireless transmission. Turn the keyboard on and set it in pairing mode (special button on the keyboard - please refer to the manual of the keyboard). Select "F1 - Search" on the meter. The meter will search for available Blue-tooth device, the operation time depends on the number of available devices within its range. After completing the search process, the meter will display a list of available keyboards (other devices: phones, palmtops, computers, etc. are not shown). From the list of available devices, select one keyboard and press "ENTER -Connect" - the meter will display the progress bar, counting on 30 seconds. During this time use the keyboard to enter PIN code and confirm it by pressing "ENTER" key on the keyboard. OPERATING MANUAL MIC-10k1 version 1.03 49 Note: The PIN code may be read or changed in MENU ? Wireless transmission ? Change PIN code. The pairing operation may end in one of three following ways: - Wireless connection enabled - pairing was successful, the keyboard has been saved in the memory and will not require re-entering the PIN, even if you change the PIN of the meter. Connection activity is indicated by symbol, displayed near the clock and it may be seen on the list of available devices*. From this moment automatic connection is available. - Wireless connection error Wrong PIN number entered - connection failure, entered PIN code is not compliant with the one set in the meter. - Wireless connection error Device not found - the keyboard is no longer available for connection. OPERATING MANUAL MIC-10k1 version 1.03 50 The meter may store up to 16 keyboards in its memory (each of them requires the full path of manual connection). * The list of available devices, has also another function: the active keyboard is displayed on the list of available devices always as the first device and it is additionally marked with "V" symbol. There is an additional option available: "F2 - Disconnect". Disconnection removes the pairing with a given device, and thus automatic connection is no longer available. 5.3.2 Automatic connection If the meter is paired with at least one keyboard, it will attempt to establish a connection to this keyboard always when the keyboard is enabled in "connect" mode. This process is automatic and al-ways takes place, regardless of the measurement function (excluding the case of active connection to a PC via Bluetooth and charger). Automatic connection is indicated by symbol, located near the clock. When more than one keyboard is paired with the device and at the moment, more than one keyboard is available in the connection mode, the connection will be made with the keyboard that first responds to the connection call of the meter. 5.4 Data transmission using Bluetooth module 1. Activate Bluetooth on your PC (if it is an external module, it must be connected to the computer be-fore). Follow the instructions of the module. 2. Turn on the meter and set the function switch in MEM. 3. On a PC enter Bluetooth connectivity mode, select MIC-10k1 (MIC-5050) device and establish the connection. 4. If the connection was successful, then the meter will display the following screen: 5. Start the software to read /save data (e.g., Sonel Reader, Sonel PE) and proceed in accordance with its instructions. OPERATING MANUAL MIC-10k1 version 1.03 51 5.5 Read-out and change of PIN code for Bluetooth connections Select Wireless transmission in the main MENU of the meter , press ENTER. Select CHANGE PIN CODE position, press ENTER. Read the current PIN, and change it if necessary, confirming introduced change by pressing ENTER. Note: Standard PIN code for Bluetooth transmission is "123". OPERATING MANUAL MIC-10k1 version 1.03 52 6 Power supply of the meter 6.1 Monitoring the power supply voltage ATTENTION To display the correct battery discharge status, it is necessary to completely discharge and then fully charge the battery, before starting the regular use of the meter. The charge level of the rechargeable battery is indicated by the symbol in the right upper corner of the display on a current basis: Battery charged. Battery discharged. Battery completely discharged. Battery extremely discharged, all measurements are blocked. 6.2 Battery power MIC-10k1 and MIC-5050 meters are powered with a gel battery which may be replaced only in a servicing point. The charger is installed inside the meter and works only with the manufacturer’s rechargeable battery pack. The charger is powered from the 230 V grid. It is also possible to power the unit from a car lighter using an optional 12 V / 230 VAC converter. ATTENTION Do not power the meter from sources other than those listed in this manual. 6.3 Charging rechargeable battery Charging commences once the power supply has been connected to the meter regardless of the fact whether the meter is on or off. Charging is indicated by battery symbol being filled and flashing green LED. The rechargeable battery is charged in accordance with the "quick charge” algorithm – this process reduces the charging time to approx. 7 hours. The completion of the charging cycle is indicat-ed by a full battery symbol and the lighting of green LED. In order to turn the device off, unplug the power charger. OPERATING MANUAL MIC-10k1 version 1.03 53 Note: - Due to interferences in the mains, the process of battery charging may finish prematurely. When charging time is too short, turn off the meter and start charging again. Additional information displayed by the meter Signalling Condition Green LED is flashing (once per second), dis-play shows the battery symbol being filled. Charging in progress. Green LED is lit continuously, display shows the full battery symbol. Charging finished. Green LED is flashing (twice per second) Charging error. Green LED is flashing along with the battery symbol (twice per second), simultaneously is displayed. Battery temperature is too high, the measurements are blocked. 6.4 Power supply from mains It is possible to carry out measurements during the charging process. To activate it, press ESC - the meter enters the measurement mode, while remaining in charging mode. Similarly, the process takes place when AC power supply is connected to the meter. When the meter is turned off by button or by Auto-OFF, the charging process is not inter-rupted. Additional information displayed by the meter Signalling Condition All segments of the battery are flashing once per second. Charging finished. Green LED is flashing along with the battery symbol (twice per second), simultaneously and are displayed. Battery temperature is too high. 6.5 General principles for gel using (lead) rechargeable batteries - Store the rechargeable batteries in a dry, cool and well ventilated place and protect them from direct sunlight. Do not install them in a tightly closed container. While charging the batteries may produce flammable gases, which may be the cause of explosion if proper ventilation is not available. The best temperature for battery storage and operation is between 15°C and 25°C. - Do not place batteries near equipment generating sparks, or store them in dusty areas. - Do not connect the battery to any plastic elements or housing elements containing solvents. This may cause the battery body to unseal or crack. - During storage of lead batteries they are self-discharged. The storage time without charging is de-pendent on ambient temperature: from 6 months at 20 °C to 2 months at 40 °C. In order to prevent ex-cessive battery discharge, resulting in a significant reduction of their capacity and durability it is re-quired to recharge them in specified intervals. OPERATING MANUAL MIC-10k1 version 1.03 54 - Do not discharge the battery to a voltage below that, specified by its manufacturer. An attempt to re-charge an over-discharged battery may cause a thermal hazard, which results in battery deformation or in change of the structure and distribution of the electrolyte in the battery as some of the water evaporates. This worsens the battery parameters similar to prolonged overcharging. Always recharge the battery immediately after discharging, even if it was not discharged to the recommended cut off voltage. Leaving a discharged battery for a couple of hours (sometimes even less than that if the dis-charge was very deep) will cause sulphating. - Charging may only be performed using a charger with specific parameters and under the conditions set by their manufacturers. Failure to meet these conditions can lead to leakage, overheating or even an explosion. 7 Cleaning and maintenance ATTENTION Use only the maintenance methods specified by the manufacturer in this manual. The casing of the meter may be cleaned with a soft, damp cloth using all-purpose detergents. Do not use any solvents or cleaning agents which might scratch the casing (powders, pastes, etc.). Clean the probe with water and dry it. Before the probe is stored for a prolonged period of time it is recommended to grease it with any machine lubricant. The reels and test leads should be cleaned with water and detergents, and then dried. The electronic system of the meter does not require maintenance. 8 Storage In the case of storage of the device, the following recommendations must be observed: ? Disconnect all the test leads from the meter. ? Clean the meter and all its accessories thoroughly. ? Wind the long test leads onto the reels. ? If meter is to be stored for a prolonged period of time, the batteries must be removed from the de-vice. ? In order to prevent a total discharge of the accumulators in the case of a prolonged storage, charge them from time to time. 9 Dismantling and utilisation Worn-out electric and electronic equipment should be gathered selectively, i.e. it must not be placed with waste of another kind. Worn-out electronic equipment should be sent to a collection point in accordance with the law of waste electrical and electronic equipment. Before the equipment is sent to a collection point, do not dismantle any elements. Observe local regulations concerning disposal of packages, waste batteries and accumulators. OPERATING MANUAL MIC-10k1 version 1.03 55 10 Technical specifications 10.1 Basic data ? The abbreviation "m.v." used in the specification of basic uncertainty denotes a standard meas-ured value AC/DC voltage measurement Display range Resolution Basic uncertainty 0.0 V...29.9 V 0.1 V ?(2 % m.v. + 20 digits) 30.0 V...299.9 V 0.1 V ?(2 % m.v. + 6 digits) 300 V…750 V 1 V ?(2 % m.v. + 2 digits) ? Frequency range: 45...65Hz Measurement of insulation resistance Measurement range acc. to IEC 61557-2 for MIC-5050 UN = 5000V: 5.00M?…20.0T?, for MIC-10k1 UN = 10000V: 10.0M?…40.0T? Measurement with DC and increasing voltage (SV) for UISO = 5 kV Display range Resolution Basic uncertainty 000 k?...999 k? 1 k? ? (3 % m.v. + 10 digits) 1.00 M?...9.99 M? 0.01 M? 10.0 M?...99.9 M? 0.1 M? 100 M?..999 M? 1 M? 1.00 G?..9.99 G? 0.01 G? 10.0 G?...99.9 G? 0.1 G? 100 G?...999 G? 1 G? ? (3.5 % m.v. + 10 digits) 1.00 T?…9.99 T? 0.01 T? ? (7.5 % m.v. + 10 digits) 10.0...20.0 T? for MIC-5050 10.0…40.0 T? for MIC-10k1 at UN = 10 kV 0.1 T? ? (12.5 % m.v. + 10 digits) For other voltages the measurement uncertainty can be calculated from the following formula: dR= ±(3 %+(UISO/( UISO-Rzm·21·10-12)-1) ·100 %) ± 10 digits where: UISO – voltage at which the measurement is conducted [V] Rzm – measured resistance [O] Approximate maximum values of the measured resistance, depending on the test voltage, are presented in the table below. Voltage Test range Measuring range for AutoISO-5000 MIC-10k1 and MIC-5050 50 V 200 G? 20.0 G? 100 V 400 G? 40.0 G? 250 V 1.00 T? 100 G? 500 V 2.00 T? 200 G? 1000 V 4.00 T? 400 G? 2500 V 10.0 T? 400 G? 5000 V 20.0 T? 400 G? OPERATING MANUAL MIC-10k1 version 1.03 56 MIC-10k1 10000 V 40.0 T? ? Note: For insulation resistance below RISOmin there is no accuracy specified because the meter works with the adjustable current limit in accordance with the following formula: ISOnomnomISOISOIUR ?min where: RISOmin - minimum insulation resistance measured without limiting the converter current UISOnom - nominal test voltage IISOnom – nominal converter current (1 mA, 3 mA or 5 mA) Measurement with AutoISO-5000 Display range Resolution Basic uncertainty 000 k?…999 k? 1 k? ±(3 % m.v. + 10 digits ) of the meter ± 1 % additional uncertainty of AutoISO-5000 1.00 M?…9.99 M? 0.01 M? 10.0 M?…99.9 M? 0.1 M? 100 M?…999 M? 1 M? 1.00 G?…9.99 G? 0.01 G? 10.0 G?…99.9 G? 0.1 G? 100 G…up to the value at which the additional uncertainty of AutoISO-5000 is 5% 1 G? ±(3 % m.v. + 10 digits ) of the meter ± 5 % additional uncertainty of AutoISO-5000 Measurement of leakage current Display range Resolution Basic uncertainty 0…1.2 mA * ** 0...3 mA 0...5mA * - resolution and units result from the measurement range of individual insulation resistance. ** - calculated basing on resistance measurements Measurement of capacitance Display range Resolution Basic uncertainty 0 nF…999 nF 1 nF ? (5% m.v. + 5 digits) 1.00 µF…49.99 µF 0.01 µF ? Measurement of capacitance is available only during RISO measurement (when discharging the object). ? Base uncertainty of measurement is met for the tested capacitance connected in parallel with a resistance greater than 10 M?. ? For measurement voltages below 100 V the measurement error is not specified. ? The cable lenght L is calculated as C/Cx, measurement uncertainty depends on measurement range. ? Time Constant TC is calculated as Riso x C, measurement uncertainty depends on meas-urement range. OPERATING MANUAL MIC-10k1 version 1.03 57 Measurement of continuity of protective conductors and equipotential bonding with ?200 mA current Measuring range according to IEC 61557-4: 0.12 ?…999 ?? Display range Resolution Basic uncertainty 0.00 ?…19.99 ? 0.01 ? ±(2 % m.v. + 3 digits) 20.0 ?...199.9 ? 0.1 ? 200 ?…999 ? 1 ? ±(4 % m.v. + 3 digits) ? Voltage at open terminals: 4 V…24 V ? Output current at R<15 ?: min. 200 mA (ISC: 200 mA...250 mA) ? Current flowing bidirectionally, average resistance is displayed on the screen, ? Compensation of test leads resistance, autozeroing. Temperature Measurement Display range Resolution Basic uncertainty -40.0…99.9 °C 0.1 °C ±(3% m.v. + 8 digits) -40.0…211.8 °F 0.1 °F ±(3% m.v. + 16 digits) Other technical data a) type of insulation .......................................................double, EN 61010-1 and IEC 61557 compliant b) measurement category .............................................IV 600 V (III 1000 V) according to EN 61010-1 c) degree of housing protection acc. to EN 60529.............................. IP40 (IP67 for closed enclosure) d) power supply of the meter............ 12 V gel battery, 90 V ÷ 260 V 50 Hz/60 Hz from the electric grid e) dimensions ......................................................................................... 390 mm x 310 mm x 180 mm f) meter weight ................................................................................................................. approx. 7 kg g) storage temperature ................................................................................................. –25?C...+70?C h) working temperature .................................................................................................. -20?C...+50?C i) humidity .......................................................................................................................... 20%...80% j) altitude (above sea level) ................................................................................................... =3000 m k) reference temperature ................................................................................................. +23?C ± 2?C l) reference humidity .......................................................................................................... 40%...60% m) display ............................................................................................................... LCD, segment-type n) number of RISO measurements, acc. to EN 61557-2 with battery power supply ................. min. 1000 o) quality standard .... design, construction and manufacturing are ISO 9001, ISO 14001, PN-N-18001 compliant p) the device meets the requirements of the EN 61010-1 and IEC 61557 standards q) the product meets EMC requirements (immunity for industrial environment) according to the fol-lowing standards ............................................................ EN 61326-1:2006 and EN 61326-2-2:2006 ATTENTION MIC-10k1 and MIC-5050 meters are classified in terms of Electromagnetic Compatibility (EMC) as instruments of Class A (for use in industrial environ-ments - according to EN 50011). Interferences, impacting the operation of other devices must be taken into account when the meters are used in other environments (e.g. domestic). 10.2 Additional data Data on additional uncertainties are useful mainly when the meter is used in non-standard condi-tions and for metrological laboratories for the purpose of calibration. OPERATING MANUAL MIC-10k1 version 1.03 58 10.2.1 Additional uncertainties according to EN 61557-2 (RISO) Significant parameter Designation Additional uncertainty Position E1 0 % Supply voltage E2 1 % ( BAT is not lit) Temperature 0?C...35°C E3 6 % 10.2.2 Additional uncertainties according to EN 61557-4 (RCONT) Significant parameter Designation Additional uncertainty Position E1 0 % Supply voltage E2 0.2% (BAT is not lit) Temperature 0...35°C E3 1 % 11 Equipment 11.1 Standard equipment The standard set of equipment supplied by the manufacturer includes: ? MIC-10k1 meter – WMGBMIC10k1 or MIC-5050 – WMGBMIC5050 ? set of test leads: ? 10 kV cable, 3 m, (cat. IV 1000 V), terminated with banana plugs, red – WAPRZ003REBB10K ? 10 kV cable, 3 m, shielded, (cat. IV 1000 V), terminated with banana plugs, black – WAPRZ003BLBBE10K ? "E" cable 10 kV, 3 m, (cat. IV 1000 V), terminated with banana plugs, blue - WAPRZ003BUBB10K ? crocodile clip 5,5 kV (cat. IV 1000 V) – 3 pcs. (black - WAKROBL32K07, red – WAKRORE32K07 and blue – WAKROBU32K07) ? blade probe 5,5 kV with banana socket – 2 pcs. (red – WASONREOGB5X5 and black – WASONBLOGB5X5) ? temperature probe ST-1 – WASONT1 ? USB cable – WAPRZUSB ? power supply 230V cable – WAPRZ1X8BLIEC ? case L-4 for accessories – WAFUTL4 ? operating manual ? calibration certificate 11.2 Optional accessories Additionally, the following items that are not included in the scope of standard equipment can be purchased from the manufacturer or the distributors: WAPRZ005BLBBE10K ? 5 m shielded cable, 10 kV, black, (cat. IV 1000V) WAPRZ020BLBBE10K ? 20 m shielded cable 10 kV, black, (cat. IV 1000V) OPERATING MANUAL MIC-10k1 version 1.03 59 WAPRZ005REBB10K ? 5 m cable, red 10 kV, (cat. IV 1000V), with banana plugs WAPRZ005BUBB10K ? 5 m cable, blue, 10 kV, (cat. IV 1000V), terminated with banana plugs WAPRZ010BLBBE10K ? 10 m shielded cable, black, 10 kV, cat. (IV 1000V) WAPRZ010REBB10K ? 10 m cable, 10 kV, red, (cat. IV 1000V), with banana plugs WAPRZ010BUBB10K ? 10 m cable, blue, 10 kV, (cat. IV 1000V), terminated with banana plugs WAPRZ020REBB10K ? 20 m cable, 10 kV, red, (cat. IV 1000V) with banana plugs WAPRZ020BUBB10K ? 20 m cable, blue, 10 kV, (cat. IV 1000V), terminated with banana plugs WAPROSONPE5 ? "SONEL Pomiary Elektryczne" (SONEL Electrical Measurements) - software for generating measurement reports LSWPLMIC5050 LSWPLMIC10k1 ? calibration certificate WAFUTL7 ? Carrying case L-7 OPERATING MANUAL MIC-10k1 version 1.03 60 WAADAAISO50 ? AutoISO-5000 adapter 12 Manufacturer The manufacturer of the device and provider of guarantee and post-guarantee service: SONEL S.A. ul. Wokulskiego 11 58-100 Swidnica Poland tel. +48 74 858 38 60 fax +48 74 858 38 09 E-mail: export@sonel.pl Web page: www.sonel.pl OPERATING MANUAL MIC-10k1 version 1.03 61 OPERATING MANUAL MIC-10k1 version 1.03 62 NOTES
Most popular related searches