ioPro - 8AI-I-ISO - Fully Isolated Current Input Modbus IO Module Brochure

ioSelectwww.ioselect.comRev: 2/23/2011ioPro™ 8AI-I-ISOFully Isolated Current Input Modbus IO Module877 3 GET IOS (877.343.8467)• Flexible Modbus-RTU IO Module• 8 Channels of Current Input 0 (4) to 20 mA• LED Status Indication on all Channels• Operating Temperature: -40° to 80°C• 1500V RMS Isolation• Fully Compatible with the ioPak WDL Radio• Works with the ioPro IOMAP for Simple Mirrored IOBaud Rates: 2400 to 115,200 bpsLED Status: General: Power, RS-485 TX and RX Channel: ON = 0, Flash = Over Range, Off = In-between 0 and Over RangeModBus Address: 1 to 127 via Front DIP SwitchIO Mix: 8 Current Inputs - 0 (4) to 20 mAField Supply V: NAField Supply I: NAResolution : 12 or 16 bits (Selectable)Accuracy: 0.2% of SpanDrift: 100ppm / °CIO Specifications General SpecificationsIsolation: 1500 Vrms (Field to Logic) 350 Vpp (Channel to Channel)Humidity: 95% non-condensingTemp (Operate): -40 to 80 °C (-40 to 176 °F)Temp (Storage): -40 to 85 °C (-40 to 185 °F)Power (V): 10 to 26 VDCPower (W): 800 mWDimensions: 22.6 x 109 x 97.5 mm (W x H x D) (0.89 x 4.29 x 3.84 in)Weight: 100 g ( 3.5 oz) Ordering Information: IOPRO-8AI-I-ISO 8 Channel Fully Isolated Current Input Modbus IO Module Accessories: IOPRO-WDL Wireless Data Link (900MHz FHSS, 0.1 Watt to 1.0 Watt) IOPRO-IOMAP Mirrored IO Mapping ModuleThe ioPro 8AI-I-ISO inputs are fully isolated from input to logic and between inputs. This module is ideal for moni-toring existing current signals which are isolated from each other and cannot be connected to a common point of reference. The standard setting for the 8AI-I-ISO module is 0 - 20mA input which represents an output value of 0 - 4095 (12 bits) in the corresponding Modbus register. In this range, a reading of 4 mA would give a Modbus value of 819 ±1LSB. To obtain an output value of 0 to 4095 for an input signal of 4 to 20mA the offset switch can be switched on. Also, this module can also be configured for a 0 - 20mA input range or ±20mA input (1µA resolution). For more detailed speci?cations and other usage information please refer to the ioProProduct Manual available on the ioSelect web site.ioSelect ioPro™ 8AI-I-ISOFully Isolated Current Input Modbus IO Module877 3 GET IOS (877.343.8467)Wiring (Field)DIP Switch DefinitionFor more detailed specifications and other usage information please refer to the ioProProduct Manual available on the ioSelect web site.Wiring (Power and Comms)1342- 12Vdc @ 30mAPin Connection+ 24Vdc @ 17mA+ Comms- RS48597.0 mm (3.82 in)22.6 mm(0.89 in) 86.5 mm (3.41 in)97.5 mm (3.84 in) 109.0 mm (4.29 in)Drawing Input 1 Common 1 Input 2 Common 2 Input 3 Common 3 Input 4 Common 4 0Vdc +24Vdc + Input 5 Common 5 Input 6 Common 6 Input 7 Common 7 Input 8 Common 8Two Wire Transmitter0(4)-20mA +24Vdc +Current Source0(4)-20mA -Sensor -SWITCH FUNCTION DESCRIPTION 1 NODE ID +1 Node ID’s from 0 to 127 are set up using switches 1 to 7 “ 2+ DI EDON 2 “ 4+ DI EDON 3 “ 8+ DI EDON 4 “ 61+ DI EDON 5 “ 23+ DI EDON 6 “ 46+ DI EDON 78 OFFSET When switched ON the inputs scaled to accept a 4mA offset . 9 BREAK Input break. When switched off the analog value will be loaded with -32767 when the input is faulty. When switched on the analog value will be loaded with 32768. 10 BAUD RATE Selects 9600 (OFF) or Programmed Baud Rate (ON) www.ioselect.comRev: 2/23/2011ioSelect, IncorporatedP: 858-537-2060, F: 800-303-5381, info@ioselect.com
Most popular related searches