KANE 940 Combustion Analyser Brochure
GAS ANALYSERS940• Big character display• High suction double headed pump• Te?on lined ?ue probe• Infra-red printer link... printed header can be customised• Memory to store 150 test results for easy transfer to PC• Long life battery recharged in situ FeaturesO2COCO2NONOxSO2• KMIRP infra-red thermal paper printer• KANE ImPrint infra-red plain paper printer Optional Extras• Oxygen to 21%• Carbon Monoxide (CO) to 10,000ppm with hydrogen compensated sensor (alternatively CO to 100,000ppm with high range sensor)• Nitric Oxide (NO) to 5000ppm with calculated NOx (alternatively NO to 100ppm with better low range accuracy)• Sulphur Dioxide (SO2) to 5000ppm• (Alternatively any toxic sensor can be replaced with a 1000ppm Nitrogen Dioxide (NO2) sensor)• Inlet Temperature• Flue Gas Temperature• Differential pressure Measures• High range CO sensor instead of standard CO sensor• Low range NO sensor in place of standard NO sensor• NO2 sensor in place of any other toxic gas sensor• SO2 sensor in place of any other toxic gas sensor OptionsHand Held Multi-Gas Emissions Analyser KANE940GAS ANALYSERSKane International LimitedKane House, Swallowfield, Welwyn Garden City, Hertfordshire, AL7 1JG, United KingdomTel: +44 (0) 1707 375550 Fax: +44 (0) 1707 393277Email: sales@kane.co.uk Web: www.kane.co.ukYour distributorWarrantyAll Kane International Limited products are warranted for 12 months from the date of purchase. This warranty covers any defects in materials or manufacturing.Kane International Limited specialise in the design, manufacture and marketing of electronic instruments for monitoring and optimising both energy usage and emissions from energy processes. Our Policy is to continuously develop and improve our products and so we reserve the right to change any part of our product specifications without prior notice. Ref: KA940LIT06Technical Speci?cations KANE940The KANE940 handheld analyser is ideal for industrial boiler flue gas measurement and analysis. It operates on all boiler types and can display 8 parameters simultaneously showing measurements and calculations of boiler efficiency and pollution.The KANE940 measures O2, flue and nett temperature and calculates CO2, boiler efficiency, excess air and losses. CO is measured with a hydrogen compensated sensor for increased accuracy. It also measures CO and calculates CO/CO2 ratio - ‘The Poison Index’ - to give complete readings for effective boiler analysis and safety.The KANE940 measures NO and calculates NOX. For more accurate pollution analysis an optional NO2 or SO2 sensor can be fitted at time of purchase. The high suction double headed pump allows the analyser to be used in flues with suction over 100 mbar without compromising measuring accuracy. The probe hose is lined with Teflon to reduce absorption of any sample gases.The differential pressure sensor can be used to measure flue draught or be used with a pilot tube (not supplied). The KANE940 has a memory to store up to 150 readings and can transfer data to a printer or PC. The printout displays the time and date of each measurement as well as personalised information such as company name and telephone number.The analyser is supplied with a flue gas probe, protective rubber sleeve, battery charger, operator’s manual and carry case.Parameter Resolution Accuracy RangeTemp MeasurmentFlue Temperaturewith Probe1.0ºC/F ±2.0ºC ±0.3%reading0-600ºC 32-1112ºFInlet Temperature 0.1ºC/F ±1ºC ±0.3%reading0-50ºC 32-122ºFPressure 0.1 mbar ±2% of full scale +150mbar to -150mbarGas Measurment *1Oxygen 0.1% ±0.2% 0-21%Carbon Monoxide(standard: H compensated)1ppm ±20ppm <400ppm±5%<5000ppm±10%<5000ppm0-10,000ppmCarbon Monoxide(high range)0.01% ±5% reading from 0.1% to 10%0-10%Nitric Oxide (standard)1ppm ±5ppm<100ppm±5%>100ppm0-5000ppmNitric Oxide (low range)1ppm ±2ppm<30ppm±5ppm>30ppm0-100ppmNitrogen Dioxide 1ppm ±5ppm<100ppm±10ppm<500ppm±5%>500ppm0-1000ppmSulphur Dioxide 1ppm ±5ppm<100ppm±5%>100ppm0-5000ppmCalculationsCarbon Dioxide *2 0.1% ±0.3% reading 0-99.9%Losses 0.1% ±1.0% reading 0-99.9%Efficiency 0.1% ±1.0% reading 0-99.9%Excess Air 0.1% ±0.2% 0-2885.0%Temp (Nett) 1.0ºC/F ±2ºC ±0.3% reading 0-600ºC / 32-1112ºFCO/CO2 Ratio 0.0001 ±0.0001 0-0.9999Poison Index 0.01% ±0.01 0-99.99Parameter DescriptionPre-programmed Fuels Natural Gas, Town Gas, Gascor, Light Oil, Heavy Oil, Propane, Butane, Anthracite, Coke, Coal, Kinsale GasDimensions: Weight 1KgHandset 220mm x 55mm x 120mmProbe L 420mm x Dia 8mm with stainless steel shaft, type K thermocouple and 3m hoseAmbient Operating Range 0ºC to 45ºC / 10% to 90% RH non condensingPower Supply (Battery Charger) Input: 110Vac / 220Vac nominal Output: 12Vac off loadBattery Life >6 hours from full charge*1 Using dry gases at STP *2 CalculatedThe KANE logo is a registered trademark of Kane International Ltd.
Most popular related searches