Labocon Systems Limited

Labocon - Atomic Absorption Spectrophotometer - Catalogue

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.www.labocon.com2 www.labocon.com2 www.labocon.comATOMIC ABSORPTION SPECTROPHOTOMETERATOMIC ABSORPTION SPECTROPHOTOMETER LAAS-100 SERIESFeaturesLabocon Atomic Absorption Spectrophotometer LAAS-100 Series spectrophotometer, which offer superior base line stability of 0.002A/30min with advance optical system to ensure simple and reliable solution for trace elemental analysis.FLAME ? Gas Control • Software controlled quick gas conversion and safetyprotection device used to analyse air- acetylene flame and nitrous oxide-acetylene flame ? Spray Chamber Metal Glass Spray • Burner Corrosion resistant titanium burners available for both air/acetylene and nitrous-oxide acetylene ? Safety System • Safety interlock mechanism that monitors the burner type, burner fitted, gas pressures. Flame on/off sensors; Power failure automatic shutdown. Liquid trap system, pressure relief plug and flame shield to protect from UV radiation ? FOR MODEL LAAS-101: • Double beam • Automatic compensation of light source and wavelength drift caused by temperature variation and electronic circuit drift • Eliminates the need for pre-heating of cathode lamp to analyse the sample quickly • Gas path system equipped with precision pressure and current stabilizing devices to obtain stable flame at low noise • A very fine light beam passes through flame providing a precise analytical test with low characteristic concentration • Adopts total reflection system to eliminate color difference • Multi-functional analysis mode for flame absorption, flame emission, graphite furnace atomic absorption and hydride generation • Quick gas conversion and safety protection device used to analyse air-acetylene flame and nitrous oxide-acetylene flame3www.labocon.com 3www.labocon.comATOMIC ABSORPTION SPECTROPHOTOMETER ? Optional accessories: • RS232 software • Graphite tubes • Graphite furnace system • Hydride generator • Nitrous oxide generator • Nitrous oxide regulator • Acetylene regulator • Recirculating cooling water system • Printer ? FOR MODEL LAAS-102, LAAS-103: • Czerny-Turner grating monochromator • Grating density of 1800 lines • Anti-corrosive plastic sprayed chamber • Metal glass spray set • Photomultiplier tube as detector • Optimized 3D lights for maximum energy • Can distinguish between manganese light • 0-10mA and 400Hz four lamps and optional six lamps with auto switch • Air cooled pre-mixed 100mm single slit titanium burner • Less than 1% precision • Air-acetylene and oxygen enriched air-acetylene flame method • Hydride generation spectrometry • Automatic calibration, curve fitting and concentration calculation • Automatic calculation of average concentration, standard deviation, relative standard deviation • Acetylene gas leakage alarm • Rapid and convenient test results opened in office software • Software remote control to solve technical problems • Windows XP/Vista operating system • Model LAAS-103: Equipped with graphite furnace ? Optional accessories: • RS232 software • Graphite tubes • Graphite furnace system • Hydride generator4 www.labocon.com4 www.labocon.comATOMIC ABSORPTION SPECTROPHOTOMETER • Nitrous oxide generator • Nitrous oxide regulator • Acetylene regulator • Recirculating cooling water system • PrinterApplicationSpecificationLabocon Atomic Absorption Spectrophotometer LAAS 100 series is widely used in analytical chemistry protocols, applications such as food and drug safety, clinical diagnostics, petrochemical, agricultural, environmental monitoring.Model LAAS-101 LAAS-102 LAAS-103Wavelength Range 190-900nmWavelength Accuracy =±0.5nm ±0.25nmWavelength Repeatability=0.3nm (single direction)0.05nmSpectral Bandwidth 0.2, 0.4, 0.7, 1.4, 2.4, 5.0nm0.2, 0.4, 1.0, 2.0nmTemperature Range None 10-35°Working Humidity None =80%Resolution <40% <20%Baseline Stability =0.004Abs/30min 0.002A/30minCharacteristic Concentration LimitCu: =0.04g/ml/1% Cu: 0.025g/ml/1%Detection Limit Cu: 0.008g/ml Cu: 0.006g/mlBackground Calibration Greater than 30 times -Overall Dimension 1220x770x730mm 1000x400x470mmWeight 160 kg 70 kgPower 660W 150WPower Supply 220V 50HzCatalog No. 9523126164 9523127164 95231281645www.labocon.com 5www.labocon.comATOMIC ABSORPTION SPECTROPHOTOMETERATOMIC ABSORPTION SPECTROPHOTOMETER LAAS-200 SERIESFeaturesLabocon Atomic Absorption Spectrophotometer LAAS-200 Series are single beam spectrophotometers designed for determining the concentration of different elements within a sample.These systems offer superior base line stability of 0.004A/30min with advance optical system to ensure simple and reliable solution for trace elemental analysis.FLAME ? Gas Control • Software controlled quick gas conversion and safety protection device used to analyse air- acetylene flame and nitrous oxide-acetylene flame ? Spray Chamber Metal Glass Spray • Burner Corrosion resistant titanium burners available for both air/acetylene and nitrous-oxide/ acetylene ? Safety System • Safety interlock mechanism that monitors the burner type, burner fitted, gas pressures. Flame on/off sensors; Power failure automatic shutdown. Liquid trap system, pressure relief plug and flame shield to protect from UV radiation • Czerny-Turner grating monochromator • Anti-corrosive plastic sprayed chamber • 10cm single slot all-titanium burner • Highly efficient metal sleeve glass nebulizer with sucking up rate:6-7ml/min • R928 Photomultiplier detector with high sensitivity and wide spectral range • Hydride analysis through Hydride vapor generator • Advance and reliable electronic design • Adopting large-scale programmable logic array and Inter I2C bus technology • European type sockets and AMP adapters with high reliability to ensure long term reliability of the whole electronic system • Sequential measurement for multi-element determination in one sample • Auto-correction of sensitivity • Easy to use AAS analysis software under Windows operating system ? For Model LAAS-201: • Microprocessor with auto-control and data processing function6 www.labocon.com6 www.labocon.comATOMIC ABSORPTION SPECTROPHOTOMETER • Less automated reasonable design provides economical usage • Digital LEC display • 2-lamp turret • Manual adjustment for wavelength and slit • Manual adjustment of vertical, horizontal positions and the rotation angle of the burner • Automatic adjustment of light source power • Auto-balance between light energy and negative high-voltage • Automatic calculation of mean, standard deviation and relative standard deviation in the range of 1-99 • Automatic curve fitting with 3-7 standards • Auto-correction of sensitivity • Self-check function to check the current status of the instrument • Simple and easy operationFOR MODEL LAAS-202, LAAS-203, LAAS-204: • Adopts oxygen rich air-acetylene flame analysis technique • Flame atomization system with flame emission burner • Accurate fully automated control system with wavelength scanning, spectral bandwidth change • Automatic adjustment of lamp current and optimization of light beam position • 4-lamp and 6-lamp turret • Automatic calculation of concentration and content • RS232 interfaceFOR MODEL LAAS-205, LAAS-206, LAAS-207: • Adopts oxygen rich air-acetylene flame analysis technique • Flame atomization system with flame emission burner • Accurate fully automated control system with wavelength scanning, spectral bandwidth change • Fully automatic graphite furnace analysis • FUZZY-PID and dual curve mode temperature control technique • Auto-correction of temperature ensure rapid heating with good temperature reproducibility and high sensitivity • Automatic adjustment of lamp current and optimization of light beam position • 4-lamp and 6-lamp turret • Auto-correction of sensitivity, automatic curve fitting and sample dilution • Automatic calculation of concentration and content • RS232 interface7www.labocon.com 7www.labocon.comATOMIC ABSORPTION SPECTROPHOTOMETERFOR MODEL LAAS-208: • Adopts oxygen rich air-acetylene flame analysis technique • Flame/graphite furnace atomization system with flame emission burner • Accurate fully automated control system with wavelength scanning, spectral bandwidth change • Fully automatic graphite furnace analysis • FUZZY-PID and dual curve mode temperature control technique • Auto-correction of temperature ensure rapid heating with good temperature reproducibility and high sensitivity • Automatic adjustment of lamp current and optimization of light beam position • Motorized 6-lamp turret • Auto-correction of sensitivity, automatic curve fitting and sample dilution • Automatic calculation of concentration and content • Sampling volume: 1µl • Accurate dual pump system, with 100µl and 1ml injectors • RS232 interfaceApplicationLabocon Atomic Absorption Spectrophotometer LAAS 200 series is widely used in analytical chemistry protocols, applications such as food and drug safety, clinical diagnostics, petrochemical, agricultural, environmental monitoring.LASS - 2088 www.labocon.com8 www.labocon.comATOMIC ABSORPTION SPECTROPHOTOMETERSpecificationModel LAAS-201 LAAS-202 LAAS-203 LAAS-204Wavelength Range 190-900nmWavelength Accuracy±0.5nm ±0.25nmSpectral Bandwidth0.1, 0.2, 0.4, 1.2nmResolution Less than 30%Baseline Stability 0.005A/30min 0.004A/30minFlame TemperatureNone 2300-2950°CGrating 1800 lines/mmFocal Length 277mmBlazed Wavelength250nmConcentration and Detection LimitCu: Characteristic concentration=0.025mg/LDetection limit=0.006mg/LCu: Characteristic concentration=0.025mg/LDetection limit=0.006mg/LBa: Characteristic concentration = 0.22mg/LAl: Characteristic concentration = 0.4mg/LOverall Dimension1020x490x540mmWeight (Net/Gross)80/- kgCatalog No. 9523129442 9523130442 9523131442 95231324429www.labocon.com 9www.labocon.comATOMIC ABSORPTION SPECTROPHOTOMETERModel LAAS-205 LAAS-206 LAAS-207 LAAS-208Wavelength Range 190-900nm 190-900nmWavelength Accuracy Better than ±0.25nm Better than ±0.25nmSpectral Bandwidth 0.1, 0.2, 0.4, 1.2nm 0.1, 0.2, 0.4, 1.2nmResolution Less than 30% Less than 30%Baseline Stability 0.004A/30min 0.004A/30minFlame Temperature 2300-2950°C 2300-2950°CGraphite FurnaceTemperature RangeRT-3000°C RT-3000°CHeating Rate 2000°C/s 2000°C/sGraphite Tube Dimensions28x8mm 28x8mmCharacter Mass Cd=0.5 ×10-12g, Cu=5 ×10-12g, Mo=1×10-11gCd=0.5 ×10-12g, Cu=5 ×10-12g, Mo=1×10-11gPrecision Cd=3%, Cu=3%, Mo=4% Cd=3%, Cu=3%, Mo=4%Grating 1800 lines/mm 1800 lines/mmFocal Length 277mm 277mmBlazed Wavelength 250nm 250nmConcentration and Detection LimitCu: Characteristic concentration=0.025mg/LDetection limit=0.006mg/LBa: Characteristic concentration = 0.22mg/LAl: Characteristic concentration = 0.4mg/LCu: Characteristic concentration =0.025mg/LDetection limit=0.006mg/LBa: Characteristic concentration = 0.22mg/LAl: Characteristic concentration = 0.4mg/LBlazed WavelengthMain Unit 1020x490x540mm 250nmGraphite Furnace420x420x460mm 420x420x460mmAuto samplerNone 400x290x290mmWeight (Net/Gross)Main Unit 80/- kg 400x290x290mmGraphite Furnace 50/- kg 140 kgAuto samplerNone 15 kgCatalog No. 9523133442 9523134442 9523135442 9523136442LABOCON SYSTEMS LIMITEDFowler Avenue, The Hub, Farnborough Business ParkFarnborough, GU14 7JF, United Kingdom+44 203 3724850 info@labocon.com www.labocon.com
Most popular related searches