LEAP Technologies by Trajan Scientific and Medical
- Home
- Companies & Suppliers
- LEAP Technologies by Trajan Scientific ...
- Downloads
- LEAP - NMR Prep Work Station - Brochure
LEAP - NMR Prep Work Station - Brochure
NMR Prep Stations offered by LEAP. Currently there are four main systems for NMR Prep and/or delivery of sample and solvent to a NMR tube using a PAL system and either LEAP Shell or Peak Harvester applications. These fall into the categories and descriptions of the systems as shown below. 1) Sample Handling/Agitation/3- or 5-mm NMR Tube fill Sample Tray NMR Tube Tray (3- or 5-mm) 6 Solvents Available Fast Wash Station All standard accessories are shown. Sample Tray and Tray Holder Inkwell Reservoirs (100-mL each) for deuterated solvents.NMR tray holder Fast Wash Station NMR Prep and Transfer. Includes: Agitation and mixing for reconstituting samples with deuterated solvents. Either Ambient Temperature with standard configuration or can integrate CoolStacks or Trays. The system uses LEAP Shell Software to optimize sample preparation. Up to 6 deuterated solvents can be selected. (Base ~ $30,000 – 33,000) 2.5-mL Syringe 6-position Agitator. Scheduling to optimize sample prep HTS-xt Version 6-position Agitator LEAP SHELL NMR SYSTEMS AND APPLICATIONS LEAP TECHNOLOGIES FALL 2011 (DH) 2) Sample Delivery into 1-mm NMR Tubes ORIGINAL CUSTOMER – BMS ISSUES – TIME, SAMPLE HANDLING, NUMBER OF SAMPLES TO PROCESS, MANUAL HANDLING OF THE SMALL TUBES AND SAMPLE SIMULTANEOUSLY, VARIATIONS TUBE TO TUBE AND SAMPLE TO SAMPLE. SPECIAL – modified FWS SPECIAL – locking NMR Tray SPECIAL – extended needle and needle guide. 6-position CoolStack HTC-xt Version LEAP SHELLSamples in 96-DW or 2-mL vials. Can be capped.CoolStack to protect samples samples from dust and other potential contaminants. Maintains a constant temperature during the sample preparation and transfer process. Extended Needle to reach the bottom of the 1-mm NMR microtube and eliminate the introduction of air bubbles Microvolume syringe and needle wash station. Minimizes solvent usage (especially for deuterated solvents). a) Locking NMR tray holder to keep the NMR microtubes in place. 1mm target area. MICROTUBE NMR Fill. Includes: Specialty Syringe with an extended needle for bottom-to-top filling in stepwise process to eliminate air bubbles in these fine 1-mm NMR Microtubes. Use a Stack or CoolStack to protect samples. The compact system can handle a rack of 96-microtubes. Specifically designed tray holder and needle guide allow for accurate and tight tolerance for the 1-mm target. (Base ~ $29,500 – 31,000) NMR SYSTEMS AND APPLICATIONS LEAP TECHNOLOGIES FALL 2011 (DH) 3) 3-mm NMR Tubes and 5-mm NMR Tubes LEAP SHELL Extended Needle to reach the bottom of the 3- or 5-mm NMR tube and eliminate the introduction of air bubbles NMR Tube Tray (3- or 5-mm) 6 Solvents Available Fast Wash Station SPECIAL – extended needle and needle guide. HTS-xt Version 6-position CoolStack Samples in 96-DW or 2-mL vials. Can be capped.CoolStack to protect samples from dust and other potential contaminants. Maintains a constant temperature during the sample preparation and transfer process. Syringe and needle wash station. Minimizes solvent usage (especially for deuterated solvents). 3 x Inkwell Reservoirs (100-mL each) for deuterated solvents. NMR Tray (Can hang or sit on the bench in its holder). Basic NMR Sample Prep and Transfer. Includes: Basic package and procedure run by LEAP SHELL to allow a researcher to reconstitute a pre-dried sample with a deuterated solvent and transfer the sample into a standard 3- or 5-mm NMR tube. The wash station is modified to minimize solvent usage and time. The fill procedure is optimized using a bottom-to-top filling process. Additional NMR tray holders can be added to increase capacity. (Base - $30,000 – 32,000) NMR SYSTEMS AND APPLICATIONS LEAP TECHNOLOGIES FALL 2011 (DH) NMR SYSTEMS AND APPLICATIONS LEAP TECHNOLOGIES FALL 2011 (DH) 4) Peak Purification/SPE Trap and Release/3- or 5-mm NMR Tube fill PEAK HARVESTER (Requires Pumps and Detector – can be either LEAP or Varian) Twin Peak Harvester Prep NMR Version SPE Stack – 96-well format NMR Tube Tray (3- or 5-mm) 3 Solvents Available FC Tray and Sample Tray Injector with FWS Dedicated Collection Head Dedicated Injection and Sample Processing Head NMR Tray and Holder Waste Station/Home FC Tray Sample Tray Injection Valve and FWS SPE Drawer and Eluate Collection Tray 3 x Inkwell Reservoirs (100-mL) for SPE and Deuterated Reagents Sample Isolation, SPE, and NMR. Includes: Peak Harvester operated system with post-fractionating scripts for sample handling after purification. This system integrates HPLC purification with SPE functionality and other transfer and sample handling processes using the PAL. The ability of Peak Harvester to use standard sample processing scripts – either as standalone methods or batch operation following purification – turns this system into a full impure to NMR Tube sample instrument. (Base ~ $60,000 – 65,000)
Most popular related searches
