CIC Photonics
MIRAN SapphIRe - Portable Infrared Ambient Air Analyzer
Industrial Hygiene MonitoringEmergency Response AnalysisIndoor Air Quality StudiesHospital Gas MonitoringFume Hood / Tracer Gas TestingLeak DetectionMIRAN SapphIRe RPortable InfraredAmbient Air AnalyzerThe MIRAN SapphIRe Series of Ambient Air Analyzers is the most versatile gasdetection system on the market today.Use of infrared spectroscopy provides the MIRAN SapphIRe Analyzers with theunique ability to specifically and accurately measure many gases with a single unit.The Analyzer’s wavelength generator has a unique design that allows accurate andfast wavelength selection. This feature alone separates the MIRAN SapphIReAnalyzer from other gas analyzers.The MIRAN SapphIRe Analyzer is available in three models with gas calibrationsfrom one to over 100 gases. Any model can be easily upgraded to another modelin the series, allowing you to economically meet both current requirements andfuture increased needs.The MIRAN SapphIRe XL. Offers optimal measurement capabilities for high-endusers who need to measure a wide variety or mixed atmosphere of gases.Contains over 120 single gas applications with customization capability. Ideal forconsultants, industrial hygienists, regulatory agencies, research scientists andemergency response professionals.The MIRAN SapphIRe SL. Provides flexibility for users who perform similarmeasurements on a routine basis. Contains over 50 single gas applicationswith customization capability. Popular with indoor air quality specialists andanesthetic gas monitoring technicians.The MIRAN SapphIRe DL. Designed for users who regularly encounter a limitednumber of air monitoring applications. Features quick and easy operation forenforcement agencies and specified compound measurement projects.Note: A list of compounds contained in the SL and XL Fixed Library is available on a separateapplication sheet.Please contact us or visit our Web site for more information.Need technical assistance? Our experienced team of laboratory specialists isavailable to help you determine the right system for your application. And… weback it up with the technical support you need.Easy to useSelectiveSensitive for sub-ppm detectionVersatile and upgradableLightweight and portableThree Models to Fit Your NeedsTraining and SupportIndustrial HygieneReal-time detection of vapors in job environments promotes safe work habits.MIRAN SapphIRe analyzers monitor at typical government-regulated levels.Emergency Response AnalysisThe MIRAN SapphIRe assists emergency response personnel in qualifying hazardous spillsand emissions.Indoor Air Quality StudiesThe MIRAN SapphIRe makes precise spot measurements for compounds such as CO2,CO, formaldehyde, or organic vapors.Waste Anesthetic GasesService technicians can identify leaks on anesthetic delivery systems by using the MIRANSapphIRe Ambient Air Analyzer as a part of Preventative Maintenance (PM) work.Fume Hood / Tracer Gas AnalysisWhen the handling of toxic substances is performed in fume hoods, worker safety canbe jeopardized. The MIRAN SapphIRe serves as an effective monitor for evaluating fumecontainment of laboratory hoods.Leak Detection for process maintenanceUsing a leak detection probe you can set up the MIRAN SapphIRe to check for leaksaround many types of process equipment.Spectral Scanning upgrade permits collection ofspectral fingerprint of unknowns, allowing forfurther in-depth analysis and identification.ISO-9001 CertifiedMIRAN is a registered trademark of Thermo Environmental Instruments Inc. Doc# 0011 8 West Forge Parkway, Franklin, MA02038 USAtel: (508) 520-0430 fax: (508) 520-1460 thermo@thermoei.com www.thermoei.comMIRAN SapphIRe Summary SpecificationsDetector Type Single beam infrared spectrophotometerOptics Linear Variable Filter (LVF) from 7.7 to 14.1µseven Fixed Band Pass Filters 1.8, 3.3, 3.6, 4.0, 4.2, 4.5, and 4.7µPump Flow Rate 15l/minAnalysis Time After power up: 20 seconds minimum; three minutes maximumAlarms User DefinableReadout 8 line x 40 Character LCDResponse time 18 seconds to 90% of final readingPathlength 0.5m & 12.5mSample Cell Vol. 2.23 litersBattery Internal, Rechargeable NiCad. 7.2 V nominal; 5.7 Ah capacity.Discharge time 4 hrs; recharge time 4 to 6 hrs.Output 0-1VDC, Parallel, SerialDimensions Approximately 553mm (21.8in) wide x 365 mm (14.4 in) high x 193 mm (7.6 in) deepMass Approximately 10 kg (24 lbs.)Intrinsic Safety User specified models are certified for CENELEC, Groups IIC, Zone 1and 2;Certifications ETL (Class I, Div. 1. Groups B,C & D,Temp. Class T4) ETL-C (Class I, Div. 1. Groups B,C & D,Temp. Class T4) CENELEC (EEx ib d IIB + H2 T4) AccessoriesLeak Detection/Sampling Wand P/N CR014QC15 3/4” (40cm) long, and is composed of anodized aluminum tubing and chemicallystable plastic.Transportation / Carrying Case P/N CR013XMWheeled case with telescoping handle doubles as a sturdy shipping case which will hold a spare battery, battery charger, cables, sample wand, carrying strap and filters.Field Performance Check Kit P/N CR014LG Untitled
Most popular related searches
